Forwards Insp Rept 50-382/85-16 on 850401-0531 & Notice of Violation
ML20133B969
Person / Time
Site: Waterford 
Issue date: 08/02/1985
From: Johnson E
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
To: Leddick R
LOUISIANA POWER & LIGHT CO.
Shared Package
ML20133B972 List:
References
NUDOCS 8508060304
Download: ML20133B969 (3)


See also: IR 05000382/1985016

Text

T

.,

AUG 0 21985

In Reply Refer To:

Docket:

50-382/85-16

1

.

Louisiana Power & Light Company

ATTN:

R. S. Leddick, Sr. Vice President

Nuclear Operations

142 Delaronde Street

New Orleans, Louisiana 70174

Gentlemen:

This refers to the inspection conducted by Messrs. G. L. Constable,T. A.

Flippo, A. R. Johnson, and W. B. Jones of this office during the period April

1 through May 31, 1985, of activities authorized by NRC Operating Licenses

NPF-26 and NPF-38 for Waterford Steam Electric Station Unit 3, and to the

discussion of our findings with you and other members of your staff at the

conclusion of the inspection.

Areas examined during the inspection included control of design changes,

radioactive contamination of secondary system, startup test procedure review,

Phase III test witnessing, test results evaluation, and survey of

licensee responses to selected safety issues. Within these areas, the

inspection consisted of selective examination of procedures and

representative records, interviews with personnel, and observations by the

inspectors. These findings are documented in the enclosed report.

During this inspection, it was found that certain of your activities were in

violation of NRC requirements.

Consequently, you are required to respond to

these violations, in writing, in accordance with the provisions of Section

2.201 of the NRC's " Rules of Practice," Part 2,' Title 10, Code of Federal

Regulations.

Your response should be based on the specifics contained in

the Notice of Violation enclosed with this letter.

The response directed by this letter and the accompanying Notice is not

subject to the clearance procedures of the Office of Management and Budget as

required by the Paperwork Reduction Act of 1980, PL-96-511.

l

RIV:RRI

RPB1f8)

RP

/p T[Uppo/rl

L(onstable

Johnson

l 7/A. /85

7/ M/85

'pl/85

I

M8EMA*Mjh2

geet

a

  • lo

,

i

,

Louisiana Power & Light Company

-2-

Should you have any questions concerning this inspection, we will be pleased

to discuss them with you.

Sincerely,

Cricinal Siened By.

J. P. Jawlon

E. H. Johnson, Chief

Reactor Project Branch 1

Enclosures:

1.

Appendix A - Notice of Violation

2.

Appendix B - NRC Inspection Report

50-382/85-16

cc w/ enclosures:

Louisiana Power & Light Company

ATTN:

F. J. Drummond, Manager,

Nuclear Services

142 Delaronde Street

New Orleans, Louisiana 70174

.

.

Louisiana Power & Light Company

ATTN:

R. P. Barkhurst, Plant Manager

P. O. Box B

Killona, Louisiana 70066

Middle South Services

ATTN:

Mr. R. T. Lally

P. O. Box 61000

New Orleans, Louisiana 70161

Louisiana Power & Light Company

ATTN:

T. F. Gerrets, QA Manager

142 Delaronde Street

New Orleans, Louisiana 70174

Louisiana Power & Light Company

ATTN:

G. E. Wuller, Onsite Licensing

Coordinator

P. O. Box B

Killona, Louisiana 70066

Louisiana Div. of Rad. Control

._

$

..

Louisiana Power & Light Company

-3-

~bec to DM8 (1E01)

bec distrib. by RIV:

  • RPB1
  • Resident Inspector

R. D. Martin, RA

  • EP&RPB
  • G. Constable, RPB1/B
  • MIS System
  • RIV File
  • R.

Denise, DRS&P

C. Wisner, PA0

  • RSTS Opr.

D. Powers, E0

  • w/766

{

1

i