' U.S. NUCl. EAR REGULATORY COMMISSION
- I1 CERTIFICATE OF COMPLIANCE O CFR 71 gg.,
For Radioactive Materials Packages v-r-
9 1.(al Certificate Number 1 ast Asuision No.
1.(c) USA /3e Identification No.1es No.1.(a) Tot $
- o. Pages Pack 1.(d) P iN 9013 0
013/B( )
- 2. PREAMBLE 2.(a)
This certificate is issued tomisfy Secticas 173.393a,173.394,173.395, and 173.396 of the Department of Transportation Hazardous Materials Regulations (49 CHI TNISS and 14 CFR 103) and Sections 146-19-10a and 146-19-100 of the Department of 9
Transportation Dangaroom Cagass Angulations (46 CFR 146-149), as amended.
I 2.(b)
The packaging and contanes demated in item 5 below, meets the safety standards set forth in Subpart C of Title 10. Code of l
Federal Regulations, Part 71. Padamgung of Radioactive Materials for Transport and Transportation of Radioactive Material Under Certain Conditions."
2.fc)
This artificate does not runsie the consignor from compliana with any requirement of the regulations of the U.S. Department of Transportation or other masslissado regulatory agencies, including the government of any country through or into which the package will be transported.
- 3. This certificate is issued on the basis of assfuer mislysis report of the package design or application-3.(a)
Prepared by (Name and addsumm#
3.(b)
Tide and identification of report or application:
Isomedix Incorporated Isomedix Incorporated application Post 1ffice Box 177 dated January 14, 1974.
, Parsippany, New Jersey 07054
~
3.(c). Docket No.
- 4. CONDITIONS This certificate is conditional upon the tidWeig of the requirements of Subpart D of 10 CFR 71, as applicable, and the conditions specified in item 5 below.
- 5. Description of Packaging and Authoriand Casamuts, Model Nurnber, Fissile Class, other Conditions, and
References:
(a) Packaging (1) Model No.:
521 (2) Description The package is a cylindrical, steel-encased, lead filled, weldment consisting of twa main units, the biological shield and a movable rotor. The main biological shield has a 5/8-inch outer carbon steel wall and a 3/8-inch thick inner stainless steel wall. A stationary center core is part of the main shield and is constructed of 3/8-inch thick stainless steel material.
The movable rotor unit contains three specimen chambers spaced 120' apart.
It consists of a 3/8-inch thick stainless steel housing filled with lead and rotates around the center core.
Within the main shield are three line sources, located 120* apart about the center of the irradiation position. The paciage is 36-1/2 inches in diameter by 40 inches long. The entirre package is surrounded by a metal heat shield which bolted to the shipping pallet.
The packaging maximum gross weight is 18,500 lbs.
8507200044 050510 PDR FDIA GLOWACK85-111 PDR q--
=
s. 4,.
- ..x,.....--.
g; _
hg.
O
).1,,W -
- Yl Page 2 - Certificate No. 9013 - Revision No. 0 - Docket No. 71-9013 i
f (3) Drawings 1
The packaging is constructed in accordance with Radiation
{
International, Inc., Drawings Nos.:
1 80017, Rev. 8 Irradiator 400229, Rev. C Cover Assembly, Rotor Housing 400220, Jter. B Housing, Rotor 400231, Rev. A Rotor Assembly 400232,1ter. A Base Assembly 400261 Rev. A Irradiator Shipping Assembly 400265, Aer. 0 Heat Shield (b) Contents (1) Type and form of material, Doubly encapsulated, stainless steel, cylindrical, Cs-137 sources, as shown on Radiation International, Inc. Drawing No.100591 (ORNL SX342).
(2) Maximum quantity of material per package 46,800 curies 6.
The package authorized by this certificate is hereby approved for use under the general ifcense provisions of Paragraph 71.12(b) of 10 CFR Part 71.
7.
Expiration date: April 30,1979
' REFERENCE Isomedix Incorporated application dated January 14, 1974.
FOR THE U. S. NUCLEAR REGULATORY COMMISSION M[
Charles E. MacDonald, Chief Transportation Branch i
Division of Fuel Cycle and Material Safety JUN 3 1977