_ ~...
)
y l
l December 20, 1996 i
Dr. Bruce Kaiser Vice President i
Fuel Operations ABB Combustion Engineering 3300 State Road P l
Hematite, MO 63047 l
SUBJECT:
ROUTINE AND AUGMENTED INSPECTION TEAM FOLLOW UP SAFETY INSPECTION OF ABB COMBUSTION ENGINEERING, HEMATITE, M0 (NRC INSPECTION REPORT NO. 070-00036/96005(DNMS))
Dear Dr. Kaiser:
This refers to the routine safety inspection conducted by Messrs. J. Jacobson, R. Krsek, and C. Blanchard of this office from November 18 through November 22, 1996, at your Hematite facility. The purpose of the inspection was to determine whether activities authorized by the license were conducted safely and in accordance with NRC requirements.
In addition to routine inspection activities, the inspection included a verification of the task actions accomplished for the re-start of evaporation operations, as outlined in the letter from Mr. Sharkey to the NRC dated November 21, 1996. At the conclusion of the inspection, the findings were discussed with Mr. Sharkey and other members of your staff.
Areas examined during the inspection are identified in the report. Within these areas, the inspection consisted of a selective examination of procedures and representative records, interviews with personnel, and observations of activities in progress.
Based on the results of the inspection, no violations of NRC requirements were identified. A weakness in your procedures program, which resulted in some i
procedures being available for use which were beyond the two-year technical adequacy review date, was identified by your staff, but not fully resolved, even though approximately six months had elapsed since the issue surfaced.
The inspector noted, however, that the content, detail, and format of those procedures which had been reviewed were improved.
In accordance with 10 CFR 2.790 of the NRC's " Rules of Practice," a copy of this letter and its enclosure will be placed in the NRC Public Document Room
)
(PDR).
I
)
I i
9612260293 961220 PDR ADOCK 07000036 C
l B. Kaiser We will gladly discuss any questions you have concerning this inspection.
Sincerely, Original Signed by R. Caniano for Cynthia D. Pederson, Director Division of Nuclear Materials Safety License No. SNM-33 Docket No. 070-00036
Enclosure:
Inspection Report No. 070-00036\\96005(DNMS) cc w/ encl:
R. W. Sharkey, Director of Regulatory Affairs R. A. Kucera, Missouri Department of Natural Resources bcc w/ enc 1: R. Pierson, NMSS P. Ting, NMSS S. Soong, NMSS E. McAlpine, RII F. Wenslawski, RIV PUBLIC (IE07)
DOCUMENT NAME:
R:\\INSPRPTS\\FUELFAC\\COM96005.DNM To receive a copy of this document, indicate in the box *C* = Copy without attach /enci *E" = Copy with attach /enci 'N" = No copy 0FFICE RIII 6
RIII A/
RIII h
,s n NAME Jacobson:bh Shear M Pederson h Y b
DATE 12/t?/96 12/d/96 12/ @ /96 0FFICIAL RECORD COPY