l SEP 2 31985 Docket Nos: 50-498 and 50-499 Mr. J. H. Goldberg Group,Vice President - Nuclear Houston Lighting and Power Company Post Office Box 1700 Houston, Texas 77001

Dear Mr. Goldberg:

SUBJECT:

USE OF ASME CODE N-413 FOR SOUTH TEXAS PROJECT UNITS 1 AND 2 The NRC staff has completed review of your request 'for authorization to use ASME Code Case N-413 for application at the South Texas Project Units 1 and 2 as discussed in the letter ST-HL-AE-1310 dated Augus~t 29,,1985.

Code Case N-413 " Minimum Size of Fillet Welds for Linear Type Supports,Section III, Division 1, Subsection NF" is an acceptable Code Case which is approved as written with no additional requirements other than those specified in the Code Case. The Code Case is expected to be endorsed by the NRC in a future revision of Regulatory Guide 1.84, " Design and Fabrication Code Case Acceptability ASME Section III, Division 1.

Code Case N-413 may, therefore, be used at the South Texas Project Units 1 and 2 for linear type supports within the limitations stated in the " Inquiry" and

" Reply" section of the Code Case.

You have stated that necessary changes will be implemented in an upcoming amendment to the FSAR. The staff finds this commitment acceptable.

Sincerely, George W. Knighton, Chief Licensing Branch No. 3 Division of Licensing cc: See next page Distribution Docket > m e JLee NRC PDR OELD, At.torney PRC System JPartlow LPDR BGrimes LB3 Reading EJordan NPKadambi ACRS (16)

D :LB#3 D

NPKadambi/es if@ ton 9/lg/85 9fi /85 t

8510010145 85092 9,

PDR ADOCn O PDR A

~

a South Texas Mr. J. H. Goldberg William S. Jordan, III, Esq.

Group Vice President, Nuclear Harmon, Weiss & Jordan Houston Lighting and Power Company 2001 S Street, N.W.

P. O. Box 1700 Suite 430 Houston, Texas 77001 Washington, D. C.

20009

-Brian Berwick, Eso.

Mr. J. T. Westermeir Assistant Attorney General Manager, South Texas Project Environmental Protection Division Houston Lighting and Power Company P. O. Box 12548 P. O. Box 1700 Capitol Station Houston, Texas 77001 Austin, Texas 78711 Mr. E. R. Brooks Mr. Claude E. Johnson, Resident Mr. R. L. Range Inspector / South Texas Project Central Power and Light Company c/o U. S. NRC P. O. Box 2121 P. O. Box 910

. Corpus Christi, Texas 78403 Bay City, Texas 77414 Mr. H. L. Peterson Mr. Jonathan Davis Mr. G. Pokorny Assistant City Attorney City of Austin City of Austin P. O. Box 1088 P. O. Box 1088 Austin, Texas 78767 Austin, Texas 78767 Mr. J. B. Poston Mr. A. Von Rosenberg Ms. Pat Coy City Public Service Board Citizens Concerned About Nuclear P. O. Box 1771 Power San Antonio, Texas 78296 5106 Casa Oro San Antonio, Texas 78233 Jack R. Newman, Esq.

Newman & Holtzinger, P.C.

Mr. Mark R. Wisenberg 1615 L Street, NW Manager, Nuclear Licensing Washington, DC 20036 Houston Lighting and Power Company P. O. Box 1700 Melbert Schwartz,Jr., Esq.

Houston, Texas 77001 Baker & Botts One Shell Plaza Mr. Charles Halligan Houston, Texas 77002 Mr. Rurton L. Lex Bechtel Corporation Mrs. Peggy Buchorn P. O. Box 2166 Executive Director Houston, Texas 77001 Citizens for Equitable Utilities, Inc.

Route 1, Box 1684 Brazoria, Texas 77422 i

. Regional Administrator - Region IV U. S. Nuclear Regulatory Commission 611 Ryan Plaza Drive Suite 1000 Arlington, Texas 76011 Mr. Lanny Sinkin Citizens Concerned About Nuclear Power 3022 Porter St. N. W. #304 Washington, D. C.

20008 Mr. S. Head HL&P Representative Suite 1309 7910 Woodmont Avenue Bethesda, Maryland 20814 e

(