ML20132D278

From kanterella
Jump to navigation Jump to search

Forwards Request for Addl Info Re License Triga Research Reactor
ML20132D278
Person / Time
Site: Dow Chemical Company
Issue date: 12/17/1996
From: Alexander Adams
NRC (Affiliation Not Assigned)
To: Butts S
DOW CHEMICAL CO.
References
TAC-M89940, NUDOCS 9612190292
Download: ML20132D278 (4)


Text

.,

December 17, 1996 Dr. Susan Butts The Dow Chemical Company Chair. Reactor Operations Committee 1602 Building Midland, Michigan 48667

Dear Dr. Butts:

1

SUBJECT:

REQUEST FOR ADDITIONAL INFORMATION (TAC NO. M89940)

We are continuing our review of your amendment request for Facility 0)erating i

license No. R-108 for the Dow Chemical Company TRIGA Mark I Research Reactor which you submitted on May 5, 1994, as supplemented.

During our review of i

your amendment request, questions have arisen for which we require additional information and clarification.

Please provide responses to the enclosed 3

Request for Additional Information within 30 days of the date of this letter.

Following receipt of the additional information, we will continue our l

evaluation of your amendment request.

If you have any questions regarding this review, please contact me at (301) 415-1127.

In accordance with 10 CFR 50.30(b). your response must be executed in a signed original under oath or affirmation.

This requirement affects nine or fewer respondents and, therefore, is not subject to Office of Management and Budget review under P. L.96-511.

Sincerely.

Original signed by Alexander Adams, Jr., Sr. Project Manager Non-Power Reactors and Decommissioning Project Directorate Division of Reactor Program Management Office of Nuclear Reactor Regulation 1

Docket 50-264

Enclosure:

As stated l

cc: w/ enclosures:

i See next page

)istrib Jtion:.

)ocket-rile-50-264 SWeiss TBurdick, R-III NRC PDR EHylton Region III PDND R/F AAdams TRe1dinger, R-III DOCUMENT NAME: S:\\264RAI7.5 To re elve a copy of this document. Indicate in the box: "C" = Copy without enclosures "E" = Copy with enclosures "N" = No copy J

j 3

l0FFICE PDND:PM ff PDNO W l PDND:D f 31)

C C, 1 l

lNAME AAdams

///

EH#%n SWeis.s 01 j

lDATE 12/l7/96 "

12/P)/96 12/l'l/96' OFFICIAL RECORD COPY ff?k$ ?S$Y64 p

PDR

["%g

[

t UNITED STATES g

j NUCLEAR REGULATORY COMMISSION f

WASHHJGTON D.C. 20666-0001 O

December 17, 1996 Dr. Susan Butts The Dow Chemical Company Chair. Reactor Operations Committee 1602 Building Midland. Michigan 48667

Dear Dr. Butts:

SUBJECT:

REQUEST FOR ADDITIONAL INFORMATION (TAC N0. M89940)

We are continuing our review of your amendment request for Facility 0)erating License No. R-108 for the Dow Chemical Company TRIGA Mark I Research Reactor which you submitted on May 5. 1994, as supplemented.

During our review of your amendment request, questions have arisen for which we require additional information and clarification.

Please provide responses to the enclosed Request for Additional Information within 30 days of the date of this letter.

Following receipt of the additional information, we will continue our evaluation of your amendment request.

If you have any questions regarding this review, please contact me at (301) 415-1127.

In accordance with 10 CFR 50.30(b). your response must be executed in a signed original under oath or affirmation.

This requirement affects nine or fewer respondents and, therefore, is not subject to Office of Management and Budget review under P. L.96-511.

Sincerely, hVc?.'z0-[f Alexander Adams, Jr.. Sento'r Project Manager Non-Power Reactors % nd' Decommissioning Project Directorate Division of Reactor Program Management Office of Nuclear Reactor Regulation Docket 50-264

Enclosure:

As stated cc: w/ enclosure:

See next page i

4 1

Dow Chemical Company Docket No. 50-264 CC:

Office of the Mayor 333 West Ellsworth Midland, Michigan 48640 Office of the Governor Room 1 - Capitol Building i

Lansing, Michigan 48913 Stan Dombrowski i.

Chair, Radiation Safety Committee i

Dow North America 1803 Building j

Midland, Michigan 48667 i

't i

I l

'I i

J

REQUEST FOR ADDITIONAL INFORMATION DOW CHEMICAL COMPANY TRIGA RESEARCH REACTOR DOCKET NO. 50-264 i

1.

On figure 6.1 of your proposed technical specifications (TSs) please indicate who is the individual responsible for the reactor facility's licenses or charter (i.e.. unit or organizational head equivalent to level 1 in ANSI /ANS 15.1-1990). the individual responsible for reactor facility operation (i.e.

equivalent to level 2 in ANSI /ANS 15.1) and the individual responsible for day-to-day operation of the reactor (i.e..

i equivalent to level 3 in ANSI /ANS 15.1).

2.

Please show on figure 6.1 of your proposed TSs the reporting line for the Reactor Operations Committee (ROC). This type of committee normally reports to level 1 management and the members of the committee are normally appointed by level 1 management.

Please justify the reporting line of the ROC.

3.

In your proposed TSs is the radiation safety function for the reactor provided by the Radiation Safety Officer? If not, please state who in the organization provides this function.

The organizational chart should show a communication line between the radiation safety function and level 3 management and a reporting line between the radiation safety function and level 1 management.

I