ML20132C465

From kanterella
Jump to navigation Jump to search
Forwards Objectives & Extent of Play for 1985 Annual Emergency Plan Exercise Scheduled for 851002,per Rh Engelken ,For Review & Comment.Offsite Elements Coordinated W/State & Local Agencies
ML20132C465
Person / Time
Site: Palo Verde  
Issue date: 07/19/1985
From: Van Brunt E
ARIZONA PUBLIC SERVICE CO. (FORMERLY ARIZONA NUCLEAR
To: Martin J
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION V)
References
ANPP-33077-EEVB, NUDOCS 8507300294
Download: ML20132C465 (8)


Text

(

.E$c l

Arizona Nuclear Power Project f333 JI!! 2 h h gl P.O. BOX 52034 e PHOENIX. arf 2ONA 85072-2034 Mr. John B. Martin, Regional Administrator July 19, 1985 ON yrpf Office of Inspection and Enforcement ANPP-33077-EEVB/GEC U. S. Nuclear Regulatory Commission Region V 1450 Maria Lane, Suite 210 Walnut Creek, CA 94596-5368

Subject:

Palo Verde Nuclear Generating Station (PVNGS)

Units 1, 2, and 3 1985 Annual Emergency Plan Exercise Docket Nos. STN 50-528 (License No. NPF-41) 529/530 File: 85-002-493; 85-056-026; G.1.01.10

Reference:

Letter from R. H. Engelken (NRC Region V) to G. C. Andognini (APS) dated December 14, 1982 regarding Emergency Preparedness Exercises.

Dear Mr. Martin:

Attached for your review and comment are the Objectives and Extent of Play for the 1985 PVNGS Annual Emergency Plan Exercise scheduled for October 2, 1985.

These Objectives and Extent of Play are submitted pursuant to the above referenced letter.

The offsite elements of the Objectives and Extent of Play have been coordinated among the cognizant state and local emergency response agencies.

If you are in need of clarification or additional information, please contact Dennis Yows at (602) 932-5300, extension 6280.

Very truly yours,

/

Gw E. E. Van Brunt, Jr.

Executive Vice President Project Director EEVB/GEC/sih Attachments cc:

R. F. Fish, Jr.

(all w/a)

R. P. Zimmerman E. A. Licitra G. M. Temple A. C. Gehr 8507300294 850719 PDR ADOCK 05000528 p

PDR

}

(5 %

\\

\\

ANPP-33077 1985 Annual Emergency Plan Exercise EXERCISE OBJECTIVES AND EXTENT OF PLAY Obiectives Onsite (Arizona Nuclear Power Project)

Demonstrate the ability to assess plant conditions, classify the event, and identify projected trends and potential consequences.

Demonstrate the ability to alert, notify, and mobilize PVNGS emergency response personnel within the time frames specified in the Emergency Plan.

Demonstrate the ability of ANPP to notify agencies in a timely manner.

Demonstrate the adequacy of the Emergency Plan and Emergency Plan Implementing Procedures both in terms of management control of an emergency situation and workability of the procedures at all levels.

Demonstrate the adequacy of security access control to PVNGS emergency response facilities.

Demonstrate the ability to effectively respond to a security event.

Demonstrate the effectiveness and availability of appropriate emergency equipment.

r-ANPP-33077 1985 Annual Emergency Plan Exercise Demonstrate the ability to determine actual or potential offsite radiological hazards and make timely Protective Action Recommendations to offsite agencies.

Demonstrate the ability to track plume passage and monitor contamination.

Demonstrate the ability to gather samples and analyze them in a radiological laboratory setting.

Offsite (State of Arizona. County of Maricoca)

Demonstrate that emergency response organizations can alert and mobilize emergency response personnel.

Demonstrate the ability to deploy appropriate equipment / personnel in a timely manner.

Demonstrate that timely and accurate decisions can be made regarding Protective Actions for the Plume Exposure P'athway Emergency Planning Zone (EPZ).

i Demonstrate that the Radiological Technical Organization can provide assessment and analysis and make appropriate recommendations for Protective Actions of a simulated release of radiciodine and noble gases.

4 ANPP-33077 1985 Annual Emergency Plan Exercise Demonstrate that the Monitoring Pool has the capability to perform terrestrial monitoring tasks.

Demonstrate the capability to establish and operate a Reception and Care Center.

Demonstrate access control and traffic regulation in the Plume Exposure Pathway EPZ.

Demonstrate the capability to control access to emergency facilities in order to maintain security during an emergency.

Joint (Arizona Nuclear Power Project. State of Arizona. and County of Maricopa)

Demonstrate timely coordination and release of information to the media through coordinated ' action by state, county, and utility elements.

Demonstrate that emergency response organizations can activate and staff direction and control facilities in a timely fashion.

Demonstrate the functiona1 adequacy of emergency facilities. -

r i

ANPP-33077 1985 Annual Emergency Plan Exercise Demonstrate the ability to coordinate Protective Actions in the Plume Exposure Pathway EPZ.

Demonstrate the adequacy of communication links between government emergency facilities, field teams, and the utility's emergency facilities.

Demonstrate the adequacy of communications with public via news media and through other public information channels; i.e., EBS, Rumor Control, etc.

Demonstrate the ability to implement personnel dosimetry for both utility and government emergency response personnel.

Demonstrate the capability to transport injured personnel and provide emergency medical service onsite and offsite.

Demonstrate the ability to perform onsite and offsite dose assessment in a timely manner.

r ANPP-33077 1985 Annual Emergency Plan Exercise Extent of Play Activation of all Emergency Response Facilities in accordance with plans and procedures.

PVNGS STSC, TSC, OSC, EOF, CHIC and CEC.

State EOC/ TOC including:

- Public Inquiry Center

- Joint Emergency News Center Maricopa County EOC REAT Center REAT Forward Center MCSO On Scene Command Post Reception and Care Center (1)

- Demonstrate capability to establish ' sleeping arrangements for evacuees.

- Demonstrate capability to monitor evacuees..

ANPP-33077 1985 Annual Emergency Plan Exercise

Response

Use of Notification System - demonstrate ability to alert government response organization.

Mobilize state and county response agencies.

Deploy state and county response organization.

Evacuation of representative resident group (25 to 30 people).

Evacuation of representative resident group with special problems (approximately 2-3 people).

Road block / control points (2) - demonstrate ability, then secure.

Radiation Monitoring Teams (3 utility, 3 government).

Use of primary communications and backup use as developed in the scenario.

Use of the Offsite Siren Activation System.

Sounding of Emergency Planning Zone sirans and two-tone alert devices will be simulated.

Warning will be disseminated to player population through the supplemental warning team. l

r-ANPP-33077 1985 Anhual Emergency Plan Exercise Simulated contaminated injury transported to Maryvale Samaritan Hospital (1 person).

Simulate' Assembly and Accountability.

9 ]