GPU Nuclear. Inc.
(
U.S. Route #9 South NUCLEAR Post Off ce Box 388 i
Forked River, NJ 08731-0388 Tel 609-971-4000 October 31, 1996 6730-96-2323 U. S. Nuclear Regulatory Commission Attention: Document Control Desk Washington, DC 20555 l
Dear Sir:
l
Subject:
Oyster Creek Nuclear Generating Station (OCNGS) l l
Operating License No. DPR-16 Docket No. 50-219
Reference:
Generic Letter No. 96-06, dated September 30,1996 l
Pursuant to your request GPU Nuclear (GPUN) Inc., operator of the Oyster Creek Nuclear i
Generating Station (OCNGS), Operating License No. DPR-16, makes the following response to your Generic Letter 96-06, referenced above.
e l
l (1)
GPUN will complete the actions requested by the Generic Letter.
f 6
(2)
In response to the Requested Actions GPUN will determine: (a.)ifcontainment air cooler cooling water systems are susceptible to either water hammer or two-phase flow i
conditions during any postulated DBA conditions; and, (b.) if piping systems that l
penetrate the containment are susceptible to thermal expansion of fluids so that i
overpressurization of the piping could occur.
(3)
GPUN will submit a written summary report containing the requested information within l
the time period requested (i.e., by January 28,1997) or will advise the NRC of an i
alternative date for submittal if the results of the industry meeting held on October 29, 1996 indicate that more extensive analysis and/or testing may be required.
l i
1 ON 0C0191 9611060292 961031 DR ADOCK 050002 9
6730-96-2323 GL 96-% Response l
Page 2 i
If modifications are required to ameliorate conditions causing systems to be susceptible to the l
phenomena described in the Generic Letter, a description of the corrective actions will be submitted to the NRC on a date which will be determined and provided at that time.
Very truly yours, i
Michael B. Roche Vice President and Director Oyster Creek i
MBR\\gmg cc:
OCNGS NRC Project Manager i
Administrator, Region I OCNGS NRC Sr. Resident inspector I