.h g.(

UNITED STATES RNO gg3

(' ;',g NUCLEAR REGULATORY COMMISSION !-

Aggl L

/~f WASHINGTON, D. C. 20555 DeCKETED USNRC June 4, 1985 35 m 4 m g c:

n-

~

Robert M. Lazo, Esq., Chairman Dr. Richard F. Cole Administrative Judge Administrative Judge Atomic Safety and Licensing Board Atomic Safety and Licensing Board U.S. Nuclear Regulatory Commission U.S. Nuclear Regulatory Commission Washington, DC 20555 Washington, DC 20555 Dr. Dixon Callihan James H. Carpenter Administrative Judge Administrative Judge Union Carbide Corporation Atomic Safety and Licensing Board P.O. Box Y U.S. Nuclear Regulatory Commission Oak Ridge, TN 37830 Washington, DC 20555 In the Matter of ARIZONA PUBLIC SERVICE COMPANY, ET AL.

(Palo Verde Nuclear Generating Station, Uniti 2 and 3)

Docket Nos. STN 50-529 and STN 50-530 c4

Dear Administrative Judges:

Pursuant to your request during our telephone conference call on June 3,1985, enclosed is Revision 4 of Applicants' Salt Deposition Monitoring Program which has been incorporated by reference in the Environmental Protection Plan for the full power license of Palo Verde Unit 1 that was issued on June 1, 1985.

Revision 4 will also be incorporated in the full power licenses for Units 2 and 3 when they are issued.

Sincerely, b

Lee S. Dewey Counsel for NRC Staff

Enclosure:

As Stated cc: w/ enclosure Service List 8506070626 850604 A

PDR ADOCK 05000529 D(

G PDR

o Arizona Nuclear Power Project P O. box 52034

  • PHOENIX, ARIZONA 85072-2034 Director of Nuclear Reactor Regulation ANPP-32660-EEVB/WFQ Mr. George W. Knighton, Chief May 17, 1985 Licensing Branch No. 3 Division of Licensing U.S. Nuclear Regulatory Commission Washington, D. C.

20555

Subject:

Palo Verde Nuclear Generating Station (PVNGS)

Units 1, 2, and 3 Docket Nos. STN 50-528(License No. NPF-34)/529/530 Salt Drift Monitoring Plan File: 85-004-419.06: 85-056-026

Reference:

(1) Letter from E. E. Van Brunt, Jr., ANPP, to G. W. Knighton, NRC, (ANPP-32275) dated March 29, 1985,

Subject:

Salt Drift Monitoring.

(2) Letter from E. E. Van Brunt, JR., ANPP, to G. W. Knighton, NRC, (ANPP-32547) dated May 3, 1985,

Subject:

Salt Drift Monitoring.

(3) Letter from E. E. Van Brunt, Jr., ANPP, to G. W. Knighton, NRC, (ANPP-32651) dated May 16, 1985,

Subject:

Salt Drift Monitoring.

Dear Mr. Knighton:

Enclosed for your information is a copy of Revision 4 of the Salt Deposition and Impact Monitoring Plan for the Palo Verde Nuclear Generating Station Units 1, 2, and 3.

This Revision 4 incorporates revisions to the monitoring plan previously provided in our letters, References (1), (2), and (3).

We request that the Evironmental Protection Plan (section 4.2.2) for the full power operating license reflect this Revision 4.

If you have any-questions, please contact W. F. Quinn of my staff.

Very truly yours, b

e E. E. Van Brunt, Jr.

Executive Vice President Project Director EEVB/WFQ/sih Enclosure cc:

~R. P. Zimmerman E. A. Licitra A. C. Gehr n

STATE OF ARIZONA )

) ss.

COUNTY OF MARICOPA)

I, Donald B. Karner, represent that I am Assistant Vice President, Nuclear Production of Arizona Nuclear Power Project, that the foregoing document has been signed by me on behalf of Arizona Public Service Company with full authority to do so, that I have read such document and know its contents, and that to the best of my knowledge and belief, the statements made therein are true.

D

\\.

- ~ D % ;:.. ~

\\

8 Donald B. Karner Sworn to before me this /7 day of '7Nd4!

, 1985.

Yhckt (f 17LeOABC-

/ Notary Public My Commission Expires:

My Comm;isica Expiras April 6,1987

Salt Deposition and Impact Monitoring Plan for The Palo Verde Nuclear Generation Stations Units 1, 2, and 3

- (Rev. 4)

Prepared For Arizona Public Service Company Prepared By NUS Corporation 910 Clopper Road Gaithersburg, Maryland-May 1985

^

e 4

s-ge 4-,,.e-y e

,y A.

Table of Contents Page 1.0 Introduction 1-1 2.0 Monitoring Program Design 1 2.1' Selection of Monitoring Locations 2-1 2.2 Sampling Methods 2-7 2.2.1 Soil Sampling 2-7

^

2.2.2 Indigenous and Agricultural Vegetation Sampling 2-8 2.2.3 Salt Deposition Sampling 2-9 2.?.4-irborne Salt Sampling 2-10 2.2.5 Sampling Schedule.

2-10 2.3 Sample Analysis 2-10 2.4 - Data Review 2-12 2.5 Quality ~ Assurance Program 2-12 Note: Changes to this document are noted in the margins on each page with

, identifying numbers representing the revision. The original issue was in February 1983; a Revision 1 was prepared but never issued, being' superseded by Revision 2, dated April 1983.

<-w

m-

'; i-List of Tables Table Page 1-1 Salt Monitoring Program for PVNGS 1-1 2-1 Summary of the Types of Sampling to be Performed for Each Sampling Location 2-4 2-2 Program Sampling Schedule 2-11 List of Figures

~ Figure Page 1 Distribution of Soil and Dustfall Sampling Locations 2-3 2-2 Distribution of Vegetation Sampling Locations 2-6 O

9

-r

--w.-,

1.0 INTRODUCTION

This document presents the design of an environmental monitoring program to determine the environmental impact, if any, due to salt drift from operation of the'PVNGS inechanical draft cooling towers.

It'is designed to meet the com-mitment for a monitoring program contained in the Environmental Report, Con-

.struction Phase. Table 1-1 is a summary of this commitment.

Table 1-1.

Salt Monitoring Program for PVNGSa Duration and Periodicity of Study Plant System Predicted Physical Biotic Preoperation Operation

~

Inducing Physical Parameter Indicator Period Period Change Change to be to be

' Monitored Monitored Drift from Foliar Airborne Salt Baseline Seasonal cooling deposition salt sensitive seasonal data until tower salt of salt plant data one level of species year prior impact to opera-determined tion aEnvironmental Report - Construction Permit Stage, Section 6.2.5.

4 The monitoring program (1) determines levels

~ airborne salt deposition, (2) defines physical and chemical propertier surficial soils, (3) estimates species richness and cover and measures salt.

.iing of the indigenous natural plant communities, and (4). measures salt loading and yield of cotton.

Comparisons of these parameters are made at sampling locations between the period prior to operation and the period during operation of one, two, and three units. There are also several control sites, which are used as back-ground locations not affected by operation of the cooling towers, that give an indication of any long term changes.

1-1

2.0 MONITORING PROGRAM DESIGN

.This section presents a description of the program design and includes a dis-cussion of the selection of monitoring locations, sampling methods and equip-3 ment, laboratory sample analyses, data review and report preparation, and quality assurance.

2.1 Selection of Monitoring Locations The. monitoring program.is conducted both onsite and offsite out to approxi-mately 20 miles from the cooling towers. Most of the sampling locations are

'4 at distances of five miles or less from the cooling towers. This 5-mile dis-tance corresponds to that beyond which salt deposition is not predicted to

~

exceed about one pound per acre per year.

Five control sites are included in the monitoring program to measure background levels of salt deposition at dis-tances unlikely to be significantly affected by PVNGS emissions.

Factors considered for the selection of these control site areas included an

'2 examination of the potential influences from any of the surrounding topography and their proximity to significant sources of fugitive dust or particulate emissions such as industry. Two control sites are located approximately 20 miles to the northwest of the cooling towers and two other control sites approximately 15 miles to the southest of the cooling towers. One control site will be an agricultural area and the other will be in native desert 4

environment for each of these quadrants. A fifth native vegetation control site is located approximately 7 miles to the northwest of the cooling towers.

A total of 44 sampling locations were selected to meet the following objec-tives:

o.

Measure site-originated deposition via dustfall collection, and any changes in vegetation and/or soil chemistry at all nearby agricul-tural fields f

o Establish background data on salt ons 2-1

o Provide salt deposition data that could possibly be correlated with 3

ongoing radiological and natural vegetation studies Demonstrate that the monitoring program can detect site-originated o

sal't deposition and determine the geographical limit of detection 3

o Provide long-term control plots (at 15 to 20-mile distances and in gl

. directions that are _least frequently downwind of the cooling towers).

for detennining background variations in salt levels in the vicinity of PVNGS.

4 Figure 2-1 shows the approximate locations of the 44 sites for the monitoring of salt deposition and soil sampling, including the 5 control locations used 3

to determine background changes, if any, in salt levels. Table 2-1 presents a summary of the types of sampling to be performed at each sampling location. At the 6 locations footnoted on Figure 2-1, the existing low-volume samplers used for the station radiological monitoring program are used to determine airborne salt concentrations. At 11 other locations near the site (see Figure 2-2),

sampling of the agricultural crops actually under cultivation are conducted.

At five onsite locations (1, 2, 3, 4 and 6), representative indigenous plant 4

communities of the site, which have been identified and monitored since 1976, are sampled semiannually (spring and fall).

During June 1983, the native vege-tation communities at site number 5 were destroyed by fire. Site number 5 was then and is currently maintained as a sampling site for dustfall and soils only. The locations of these five communities, shown in Figure 2-2, provide 3

continuity with an ongoing baseline study of native vegetation (see Section 2.2.2.1).

Soil and dustfall monitoring are also conducted at these locations.

'1 The monitoring program has 33 sampling locations within approximately 5 miles of the cooling towers. These locations were selected so that any measurable changes in deposition due to operation of the cooling towers woult Se detected by the monitoring program. Additionally, those sampling locations oriented

'toward the northeast of the towers correspond to the predicted direction for maximum deposition of salt.

2-2

/

- J. !. l. ;. l

  • s$ g;.

- Vhg-i,;

hll*

,.r i. F hl,.'1l3

    • (,. t

. kp. g l

r t

i i

e

/

p

- l. glQI.,

.l -

s f

l

,.,,7 g

f

- \\.

,..l ig mi e

.i

-i.

.,.I*j

... i t '. __%. {.i.J.p. A i.

. l.,,.l

_ y-

.g c

. b,.,

_,_ :. i 1.. J.

. i,.

.e....

a-

. ; X',

44.. p..t 1

m m

i,. K... /i.

s N '.-T

,.. l ',.. g,. f.:-,y %:l:

!/

  • g Q_

2q-..

n

=~

M:

i

.S m (I..!.4.i. gi Ap b, b,.-

b,.,o b' %

-r s

.s.:..,.-

eo h /

M\\

'l i

r

. 11 aE m'P..'.'i@nW.

j...l.3 I'

./A

.-4

.,/1:...f.

n h1.ff.

v.g:.--

m.e.y.

af,.

... f..

.81. g t.

7 1.

J. i.

/

1..

f.

.t L M C L ;'.;. L ' :- : C. } g : :n y..

/...

..r s.-e.

s...).

.: 4,

- '4

.y.1 r 2d

.4 4,o.c. 7 er7\\\\ i. h.'.:. is

- 1. 'wg>yg/s^ ;B s

3:

g mcn:. n,u -

n.

l V. n.,2 w

.ik VWAkta4.s'.,/.lQ;-

f n

< a

.W

./ '

y. I 4,;

T., '

\\ Qgg k. l/I&.

I h

{

.Yl.;. W j

j

'~

(Q '. i..,

1.,;

'..: ) ~M--% f6

.(f

=

l

.- 1

. l/,'.

Q.'

5k

_-ll a,W. G-lii h r -

?-

I

A kl t

[ '. W\\ '

I'~ /

',, 1j y

~

ry.-

  • \\ >

.g).g

.Ek E! L 1

5 i

.gA.

.)].., w

. I gf.!- f

. kw;

.y L_,

l.

. \\._

j i t....g. i. y v., irar Sy i.uy 1 A

.fm ~. R. i.

4 r-

.n

/1. :. w ;

i

/ p-

..jp

,. M. q,'....

.c 9

. !- x !, '. >. /.;

, j..:.

g.. ;

N e

v. ;.../. p.,.al.i.i.i. e. ; j

/yt:,.,:i @ g.

F.I.cs. !.m

!. !.j.p y..

-l

, 7 5. i.}n./.

.R.,

. / u., p hi s,< :

g i.. r..f

. g.y/.s v

%.s%

g, j

,<; o

. n

~. ~

2 s

n,..

j

~

h

. g.

g.,e. c i

.f..i....,.

a~~i. !

~%

,.=.

t l&

/. T

-0. R. \\ /,Ir E..s.

s. yI /

':i e

t.. !.g. y N.t,,,;

. lfg

.i. g.,.

.y < n,-

i a.

v h

?

o.) y.,

3.s

.c -

-.ig 1p r

....i-p.

./

.l.j Il;L, s

.l.

=

f.

5

'5 f

.-(.

., / -

8 l

5 12

,l.

.f'

.n 7

.i.q

,,. l

/-

o 41 4

.i.i.t..

c.

I

Table 2-1 Summary of the Types of Sampling to be Performed at Each Sampling Location Airborne Airborne Sampling Salts Via Salts Via Location Dustfall Native Low Volume No.

. Collection Soils Vegetation Agricultural Samplers

.. ~. -.

2 1

X X

X 2'

X X

X 3

X X

X 4

X X

X f

Sa X

X 6

X X

X 2

7 X

X X

'8 X

X X

9 X

X X

10 X

X X

11 X-X X

12 X

X X

13 X

X X

14 X

X 15 X

X 16 X

X 17 X

X 18 X

X 19 X

X 20 X

X X

21 X

X X

22 X

X 23 X

X X

24 X

X X

25 X

X X

26 X

X 27 X

X X

28 X

X X

29 b

'30 X

X X

31 X

X X

32 X

X X

33 X

X 34 X

X 35 X

X 36 X

X a

e 2-4

Table 2-1 (Continued)

Summary of the Types of Sampling to be Performed at Each Sampling Location Airborne Airborne Sampling Salts Via Salts Via Location Dustfall Native Low Volume No.

Collection Soils Vegetation Agricultural Samplers 37 X

X 2

38-X X

39 X

X 40 X

X X

41 X

X 42 X

X X

43 X

X X

44c X

X X

4 45d X

X X

Total 44 44 8

13 6

aNative vegetation communities destroyed by fire in June 1983.

b ecommissioned during June 1984 Monitoring equipment was destroyed by D

agricultural activity.

cEstablished as.a native vegetation control site for salt bush.

In May 1984, the saltbush plant community at site Number 42 was tilled and the land was converted to agricultural use sometime prior to May 1984.

d egan operation in July 1984 to replace site Number 29.

B Y

B 2-5

\\

$n Nhl$f lf',.\\hh

- ' 'f.W

.l: W

\\

h e g. fj bri.;_.3.; g.,.fi.

l.l h. j *.j, yy

,.j. f. ;,/[p

' +t:

_.! _.!.t, L,

r

,,. 4 l. g. ;'.x (l,

.l.l.

. 7.,. l:

es

.n

~

==

y.

ii.n.w w mlt

! I 1.

. \\.,1-pn. l.

., N i iW. '/. f.

I- @A

..,,gogp$

i.

.i./,

i r

t. g.

i..,,,'

..y.sm7.y q. g m%.4

$*.(. w.i.i.

q- _

e li *f*l.

.d f/

_ f,.

.b.-P.

3(*

>-l.

' ' ',! ' ' "j

,i,

  • j-ge% 4Iy.

s /.

' 51. %. _ a.

1 :

i,. F

-tr--W d.:.

4.' 9 g&. i. I.%. w.f,.. w -r;.

l y.

m -

!.g 2'-

. 'x!

n.

Mf.

m i,....p-.

e

m.,. a...x

.i.

y,,_, ;..t r

j.;.,(

1 3MFA QO:.i /. AMH.i 5, 3,

a. vme.>.g.

. xp 1 p-3.----1. tq.

.:n

,. m. -

v

t r

.u W.wiix

+ \\.t,n1 Y.=

.'f.,--

W.-

w

.w 3 ', t

...a.._m v 9:.'.ci.

N

,i g

rt kl.

. v.. w A

wt % eo, yen. q.W.
w. :. n

.vi.

ec p

7,

/-

.a.

/

g?.J. a gg_-

<.d,, w s

.s w,

z Q;,; __

r

i. O.

.r

- /

-v y

3 7

t.

-g w

\\:

. c=y

{, (t... w. w.g. a,, y.

a.i-

. 3 t,.r. a..k..

yu m,.

O

,v. >.

-t m.g.

-+

>y.

y.-

. r. x rr,. >.,..

. m.

a p i

n.

.y.y s.

x,.

1

,t 3

..x !...,1.m

<. ! i m 4

l

-v. ; : p

l. a.\\.c n

.,.p--./yp

. f. u..

,of 1

. m.i.

. L w.;

..w.

g n.,

w. / gt 2

i g 4

>I

.f

,3

7..,,..c 7y.

,..i k:

a fr. i. f.rWf.

c

., r 5

. 3.g H.c. m.

f,u- %

t pw,,

.t

..,.n. v m, q,

,x P.

.fr!

i.

}

u. a.

-y

,. y a

w-fz

}/-

i r-I

^

\\ r N

?

Jd gl.

g 3

. i; r.

c.

ff g

)

.v t'

f:

/

2 5

a

.u

.,ip y.

i E.

.g

..j i

f.

if g.

_ q.

f,;

.s

...g

.l.

., qi.y w g=o p

E

.n.3

.y.

T.l-

ll g.\\

..y p:-ti.

.-.y. m.y b

/ t..w

.p.N t

l Q'y yj}y

.!. /.

.H 4

.. r.

't =h i Y.h.

ll9. I kJ

.h O'

I

. i.. V

./

i lf' i^

A

)

LA r

b Il-lM N.

\\.

\\. L *'.u.

k k..:_;I l --,

A.,

l-1-l.

--lll l

-.. l l

...;llit... ps

.}

/..

l

r Additional criteria used as a basis for selection of the monitoring sites included the specification of their location at a distance from roads adequate to minimize the collection of traffic-generated dust.

2.2 Samplino Methods The sampling methodologies presented below and described in further detail in the applicable work instructions are designed to assure valid data acquisition.

Five separate sampling methodologies are described; one for soils, twc for vegetation (indigenous and agricultural), and 'two for airborne salt.

2.2.1 Soil Sampling At each of the 44' monitoring locations, composite soil samples (based on 5 cores from each of 2 transects) are collected at the end of the dry season (July-August), and at the end of the wet season (normally February-March); an additional sampling is conducted e' all 13 agricultural sites after cotton defoliation. The sanpling procedure (Reference Work Instruction GO 5.2.16.1) follows the DOE Environmental Measurements Laboratory's HASL-300 Method for soil sampling,(1) and uses a soil auger to collect 3-inch diameter core samples in depth increments to 30 cm, which are divided into upper and lower segments. The depth to the break between upper and lower segments is determined in the field for uncultivated soils based on the depth to a textural change.

Cores in cultivated areas are divided into equal upper and lower segments. All upper segments and all lower segments for each transect are separately combined to form 4 composites (2 depth increments for each of 2 transects) from each of which 2 samples are taken and labelled. One sample of each composite is shipped to the analytical laboratory for analysis and the other retained in storage.

2 (1) Department of Energy, Environmental Measurements Laboratory, EML Proce-i dures Manual, HASL-300, New York, NY, undated.

l a

2-7

\\

Q 1

2.2.2 Indigenous and Agricultural Vegetation Sampling 2.2.2.1 Native Vegetation Representative native plant communities, which have been identified and moni-tored since 1976 to determine baseline conditions, are sampled semi-annually 4

(March /Apri!andAugust/ September). Eight vegetative study areas are sampled as depicted in Figure 2-2.

The indigenous plant communities of the PVNGS are dominated by creosote and salt bush. Associated with these are mesquite and several species of cacti.

The vegetative monitoring program conducted within the eight vegetative commun-ities (Reference Work Instruction SRO 5.2.32.2) includes:

o The measurement of species richness and relative cover.

4 o

The measurement of salt loading in tissues of the dominant or co-dominant flora (other than cacti).

2.2.2.2 Crop Sampling At each of the 13 agricultural monitoring locations (Figure 2-2), agricultural 2 crops are sampled (Reference Work Instruction SR0 5.2.32.1) twice each growing season (e.g., June and September for cotton) prior to defoliation (or harvest) to determine the amount of plant tissue salt loading. Additionally, cotton L

yield is obtained by collecting the seed and fiber (boll) from selected cotton plots (ReferenceWorkInstructionSR05.2.32.1) as well as from the Agricul-tural Stabilization Conservation Service.

2.2.2.3 Infrared Photography In addition to the quantitative vegetative analyses, both native vegetation and agricultural crops are monitored using infrared photography (Reference Work Instruction SRO 5.2.32.3). Aerial photography (false color infrared) is 4

performed to coincide with peak vegetative crop productivity for the principal crops grown in a 5-mile radius of PVNGS (e.g., August / September for cotton).

2-8

3 This methodology permits the detection of vegetative stress, confirmed by field inspection, whether due to natural or artificially induced (e.g., salt drift) conditions and provides a documented photographic record of existing environmental conditions.

2.2.3 Salt Deposition Sampling 3

The rate of salt deposition is measured by the collection of dustff.1 samples which are analyzed for salt content. The dustf all sampling (described in ASTM method 01739(2))

is accomplished by placing pairs of open jars at the selec-ted monitoring locations. Two jars are placed at each sampling location to provide an estimate of sample precision.

The jars are elevated approximately three feet above the ground on stands, with a bird ring placed around the edge of the jar to prevent birds from. perch-ing and contaminating the sample. This height differs from the recommended minimum height of eight feet presented in the ASTM method to permit the collec-tion of dustfall at the approximate plant crown height. A chemically inert 1 to 2 mm conical screen is hung above the maximum water level in the jars to keep out any potential contaminants such as insects.

The monthly sampling (Reference Work Instruction EMD 5.2.17.27) follows the ASTM method for collection of destfall. At the end of each month the jars are collected and replaced by a clean set of jars. The collected jars are rinsed to transfer the samples to shipping bottles which are labeled and sent to a laboratory for analysis. At least one inch of water is maintained in the jars to prevent collected dust from being blown out. The distilled water added to the jars contains 15 mg/ liter of copper sulfate as an algicide. An 18-inch deep ASTM jar used for dustfall collection is the most suitable collection jar for sampling in a desert environment; it requires less frequent checking and replenishment of the water level than other, shallower jars.

(2) American Society of Testing and Materials (ASTM), Standard Method for s

Collection and Analysis of Dustfall (Settleable Particulates) 01739-70, Annual Book of ASTM Standards < Part 26, Philadelphia, PA.,1970.

2-9 L

r-e 2.2.4 Airborne Salt Sampling Airborne salt concentrations,are measured by collecting particles on a low-3 volume particulate sampler. Measurements are taken from the six existing low volume samplers (Figure 2-1) being used as part of the radiological monitoring program. The samplers are made by Schmidt, Inc., and draw air through a 50 mm 4

diameter filter. The filters are collected weekly for radiological analysis and are composited for the additional chemical analyses on a monthly basis.

2.2.5 Sampling Schedule The monitoring program frequency for salt deposition is generally on a monthly basis. Although the low-volume particulate filters are collected weekly, the

~

filters collected during any one month are combined and processed as one collet-tive sample for each site. Other exceptions include: native vegetation, sampled twice each year, in March / April and in September / October; agricultural sampling in June / July and again with aerial photography in August / September; and soils sampled at the end of the rainy (normally February / March), and the 4

dry seasons (July / August) and post-defoliation (November). The dustfall samples l

and low-volume sampler filters are analyzed on a regular monthly schedule.

Cooling tower basin water is sampled at least quarterly to provide the chemical composition data used as a basis for comparison with the analyses of deposited and airborne material samples. Table 2-2 summarizes the sampling schedule for components of the program.

2.3 Samole Analysis Samples collected during thi program are sent to selected laboratories for the indicated analyses. The laboratory procedures adopted for analysis of soi's, vegetation, water, and dustfall are documented. The procedures include the documentation of quality control checks on the instrumentation and the analyses.

2-10

=

t Table 2-2.

Program Sampling Schedele COMPONENT MONTH J.

F M

A M

J J

A S

0 N

D Particulate Dustfall X

X X

X X

X X

X X

X X

X Airborne Sant Concentration X

X X

X X

X X

X X

X X

X

~(Mo. Avg.)

4

. Soils X/X X/X X

l Native Vegetation X/X X/X Crops X/X X/X 4

Aerial Infrared Photography X/X l

Cooling Tower Basin Water X

~

X X

X Soil samples are analyzed for the following: pH; soluble Na, Ca, K, Mg; B; exchangeable Na, Ca, K, Mg; electrical conductivity; SO ", NO, Cl,

F, 4

3 3, HCO, NH + and P0 ". Textural analysis is performed once as part of a C0 3

4 4

baseline characterization for each monitoring site. Native vegetation and crop samples are analyzed for Na, Ca, K, Mg and for as SO ", NO, Cl, F and 4

3 4

PO4 l

The collected dustfall samples are analyzed for total suspended solids and the most significant components of the cooling tower blowdown (and drift) as iden-tified in Table 3.6-1 of the PVNGS ER-OL, Units 1-3.

Since copper sulfate is used as an algicide, the analysis also includes copper.

Finally, cooling tower basin water is sampled and analyzed at least quarterly for the same major constituents as the dustfall samples and identified in Table 3.6-1 at the PVNGS ER-OL, Units 1-3, to confirm the composition of the drift (and blowdown). As a minimum, these include: Ca, Mg, Na, K, Cl, NO3' SO ", and Si. Additionally, minor constituents are quantitatively assessed to 4

the extent possible.

2-11

'^

Interpretation of the aerial photography is conducted by qualified personnel.

3-Areas of apparent vegetative stress are delineated, and a field inspection l

conducted to identify causal effects for all areas of apparent stress.

If there are any environmental charyges, a map is prepared which indcates those areas.

2.4 Data Review 3

The reported data is examined by NUS for consistency. Suspicious data may prompt & request for a repeat analysis of the sample (s). Meteorological data are used.to ascertain that the pattern of salt deposition is consistent with the prevailing winds, stability classes, and precipitation over the period of sampling. Patterns of inconsistent data, or locations with large differences in the paired samples may indicate that the locations are subject to interfer-ences or tampering. Additional sampling or an alternate,. sampling location may-be. required for these locations. Once the individual data have been examined, timely summaries are prepared. Data are compared for discernible differences between the control samples.

Seasonal and annual summaries are prepared and the data examined for cor-relations with meteorological conditions over the period. Methods for demon-strating differences in the annual data include changes in the chloride to sodium ratios, and isopleths of annual concentrations. The evaluation of the control and plant vicinity differences includes analyses for correlation between salt deposition, airborne concentration, and changes in soll and/or plant chemistry. Detailed evaluation of changes in any of the three media (air, soil, plants) at one or more sampling locations are evaluated by ap-propriate statistical analyses.

2.5 Quality Assurance Proaram A comprehensive quality assurance program is essential for the successful con-duct of a good monitoring program. The quality control measures designed into the program include:

2-12

o' Colocated samples at each sampling location to determine sample pre-cision; t

o An observation and da.ta record for each sample; o

The checking of the algicide concentration as an indication of_ sample integrity for dustfall samples; o

Sampling at a range of distances from the cooling towers to show the

-procedures are capable of detecting salt deposition and also for determining the limit of detection; o

led written procedures for all aspects of the program 3

Written quality assurance procedures have been developed in accordance with the quality assurance requirements of APS. The laboratory quality assurance programs provide the required quality assurance checks on the sample analyses at the laboratory. An independent audit and inspection will be conducted to review the sampling methods and the techniques and records of the analytical laboratory.

2-13