October 2, 1996 Dr. Susan Butts The Dow Chemical Company Chair, Reactor Operations Committee 1602 Building Midland, Michigan 48667
SUBJECT:
REQUEST FOR ADDITIONAL INFORMATION (TAC NO. M96111)
Dear Dr. Butts:
We are continuing our review of your request to make changes to the Dow TRIGA Research Reactor Emergency Plan which you submitted on July 8, 1996. During our review of your request, questions have arisen for which we require additional information and clarification.
Please provide responses to the enclosed request for additional information within 30 days of the date of this letter.
In accordance with 10 CFR 50.30(b), your response must be executed in a signed original under oath or affirmation.
Following receipt of the additional information, we will continue our evaluation of your request.
This requirement affects nine or fewer respondents and, therefore, is not subject to Office of Management and Budget review under P. L.96-511.
If you have any questions regarding this review, please contact me at (301) 415-1127.
Sincerely, i
Original signed by:
Alexander Adams, Jr., Senior Project Manager Non-Power Reactors and Decommissioning Project Directorate Division of Reactor Program Management Office of Nuclear Reactor Regulation Docket No. 50-264
Enclosure:
As stated cc w/ enclosure:
4 See next page DISTRIBUTION:
Docket File 50-264 BGrimes Region III PUBLIC SWeiss TReidinger, RIII i
i PDND r/f EHylton TMartin AAdams
/
p f L,,,/
PDND:
P (A
ND:D AAd ton SWeiss 10/
10/ L/96 10/V/96 0FFICIAL RECORD COPY DOCUMENT NAME: A:\\RAI96111
(
hh 9610080018 961002 i
PDR ADOCK 05000264 P
T 1
,f""%
1 UNITED STATES l
p s
j NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20666 4001
'+4 *... + 4 October 2, 1996 l
l Dr. Susan Butts l
The Dow Chemical Company 1
Chair, Reactor Operations Committee l
1602 Building Midland, Michigan 48667 l
SUBJECT:
REQUEST FOR ADDITIONAL INFORMATION (TAC NO. M96111)
Dear Dr. Butts:
We are continuing our review of your request to make changes to the Dow TRIGA Research Reactor Emergency Plan which you submitted on July 8,1996. During our review of your request, questions have arisen for which we require i
additional information and clarification.
Please provide responses to i.ne enclosed request for additional information within 30 days of the date of this letter.
In accordance with 10 CFR 50.30(b), your response must be executed in i
a signed original under oath or affirmation.
Following receipt of the l
additional information, we will continue our evaluation of your request.
This requirer.ent affects nine or fewer respondents and, therefore, is not subject to Office of Management and Budget review under P. L.96-511.
If you have any questions regarding this review, please contact me at (301) 415-1127.
Sincerely, h$dNT0"
&m Alexander Adams, Jr., Sen ofect Manager Non-Power Reactors and D co issioning Project Directorate Division of Reactor Program Management Office of Nuclear Reactor Regulation Docket No. 50-264
Enclosure:
As stated cc w/ enclosure:
See next page i
l r
T Dow Chemical Compary Docket No. 50-264 cc:
Office of the Mayor 333 West Ellsworth Midland, Michigan 48640 Office of the Governor Room 1 - Capitol Building Lansing, Michigan 48913 Stan Dombrowski Chair, Radiation Safety Committee Dow North America 1803 Building Midland, Michigan 48667 r
I 4
N
ao ENCLOSURE REQUEST FOR ADDITIONAL INFORMATION DOW TRIGA RESEARCH REACTOR EMERGENCY PLAN DOCKET NO. 50-264 1.
It was noted during the review that the proposed emergency plan did not include some certain basic information. This information includes, a map showing the location of the facility, the EPZ, a floor plan showing the facility layout, and a diagram showing the overall emergency organization.
Please either amend the emergency plan to address the above mentioned items or explain why these items were not included. Additional guidance and information on the content of emergency plans for non-power reactors can be found in NUREG-0849, " Standard Review Plan for the Review and Evaluation of Emergency Plans for Research and Test Reactors."
- 2. ' Siren switche< are discussed in the plan but are not defined.
Please provide a definition of siren switches and discuss the effect of an increased number of switches on emergency preparedness.
3.
In your submittal, the phrase, "and will have portable equipment. for taking air samples" was removed _because the. Mic.higan Division Industrial Hygiene Gro'up' does not have equipment for taking air samples.
Please provide information regarding how this function will be handled.
If this capability is removed, please explain why its removal does not reduce the effectiveness _of the plan.
4.
The EALs for a NOUE were changed to eliminate events such as tornados, fires, saturity events, etc.
Please provide the basis for removing these EALs and explain why removing the wording does not reduce the effectiveness of the plan.
5.
Letters of Agreement with the offsite support organizations did not appear i
to be included in the emergency plan.
Please provide the section(s) of l
the emergency plan which includes the current Letters of Agreement.
Alternatively, if such letters exist, but are not part of the plan, please i
l provide copies of them and explain why they are not part of the plan.
k