ML20129F047

From kanterella
Jump to navigation Jump to search
Discusses Integrated Insp Repts 50-454/96-06 & 50-455/96-06 on 960817 & Forwards Nov.Nrc Identified Open Watertight Door During Insp Period
Date released: 05/22/2020 Download: ML20129F047


Insp Repts 50-454/96-06 & 50-455/96-06 on 960703-0817. Violations Noted.Major Areas Inspected:Operation, Maintenance,Engineering,Plant Support & Plant Status
ML20129F130
Person / Time
Site: Byron Constellation icon.png
Issue date: 09/24/1996
From:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To:
References
Download: ML20129F130 (24)
Notice of Violation from Insp on 960703-0817.Violation Noted:Corrective Actions Resulting from Discovery of Open Auxiliary Bldg Floor Drain Sump Room Door on 960222,event Ineffective in Preventing Recurrence of Condition
ML20129F109
Person / Time
Site: Byron Constellation icon.png
Issue date: 09/24/1996
From:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To:
References
Download: ML20129F109 (1)
Discusses Integrated Insp Repts 50-454/96-06 & 50-455/96-06 on 960817 & Forwards Nov.Nrc Identified Open Watertight Door During Insp Period
ML20129F040
Person / Time
Site: Byron Constellation icon.png
Issue date: 09/24/1996
From: Caldwell J
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To: GRAESSER K
COMMONWEALTH EDISON CO.
References
Download: ML20129F040 (4)