ML20129C646

From kanterella
Jump to navigation Jump to search
Amend 112 to License DPR-62,changing Tech Specs to Revise Primary Containment Air Max Average Temp from 135 to 140 F for 30 Days
ML20129C646
Person / Time
Site: Brunswick Duke Energy icon.png
Issue date: 07/12/1985
From: Vassallo D
Office of Nuclear Reactor Regulation
To:
Carolina Power & Light Co
Shared Package
ML20129C650 List:
References
DPR-62-A-112 NUDOCS 8507290506
Download: ML20129C646 (4)


Text

.

/

?

8"

'n NUCLEAR REGULATORY COMMISSION UNITED STATES g

WASHINGTON, D. C. 20555 CAROLINA p0WER & LIGHT COMPANY DOCKET NO. 50-324 BRUNSWICK STEAM ELECTRIC PLANT, UNIT 2 AMENDMENT TO FACILITY OPERATING LICENSE Amendment No.112 License No. DPR-62 1.

The Nuclear Regulatory Comission (the Comission) has found that:

A.

The application for amendment by Carolina Power & Light Company (thelicensee)datedJuly 12, 1985, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act) and the Comission's rules and regulations set forth in 10 CFR Chapter I; B.

The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Comission; C.

There is reasonable assurance (1) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Comission's regulations; D.

The issuance of this amendment will not be inimical to the comon defense and security or to the health and safety of the public; and E.

The issuance of this amendment is in accordance with 10 CFR Part 51 of the Comission's regulations and all applicable requirements have been satisfied.

2.

Accordingly, the license is amended by changes to the Technical Specifications as indicated in the attachment to this license amendment.

l and paragraph 2.C.(2) of Facility Operating License No. DPR-62 is hereby amended to read as follows:

i 8507290506 850712 f

ADOCK 05000324 PDH L-

. ~

(2) Technical Specifications The Technical Specifications contained in Appendices A and B, as revised through Amendment No. 112, are hereby incorporat'd in the e

license. The licensee shall operate the facility in accordance with the Technical Specifications.

3.

This license amendment is effective as of the date of its issuance.

FOR THE NUCLEAR REGULATORY COMMISSION Domenic B. Vassallo, Chief Operating Reactors Branch #2 Division of Licensing

Attachment:

Changes to the Technical Specifications Date of Issuance: July 12, 1985 1

1 I

I ATTACHMENT TO LICENSE AMENDMENT NO. 112 FACILITY OPERATING LICENSE NO. DPR-62 l

DOCKET NO. 50-324 Revise the Appendix A Technical Specifications by replacing the current page 3/4 6-8 with the enclosed page 3/4 6-8.

The revised areas are indicated by marginal lines.

l t

l l

l l

l L

( B S F.P-2-67 )

CONTAINHENT SYSTEMS PRIMARY CONTAINHENT AVERACE AIR TEMPERATURE LIMIT!HC CONDITION FOR OPERATION Primary containment average ' ir temperature shall not exceed 135 F.*

l 0

3.6.1.6 a

APPLICABILITYt OPERATIONAL CONDTTIONS 1, 2, and 3.

l ACTIOHf With the primary containment average air temperature > 135 F*, reduce the l

0 averare air temeerature to within the limit within 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br />, or be in at least HOI 54UIDOWN within the next 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> and in COLD SHUIDOWH within the following 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />.

SURVEILLANCE REQUIREMENTS 4.6.1.6 The primary containment average air temparature shall be the volumetric average of the temperatures at the following locations and shall be determined at least once per 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />st Location a.

Below 5' elevation, b.

Between 10' and 23' elevation, t.

Between 28' and 45' elevation, d.

Between 70' and 80' elevation, and e.

Above 90' elevation.

The primary containment average air tcaporature limit may be increased to 140*F until August 15, 1985, at which time the limit will be returned to 135*F.

URUNSWICK - UNIT 2 3/4 6-8 Amendment No. II2 m