ML20129A284

From kanterella
Jump to navigation Jump to search
Fourth Partial Response to FOIA Request for Documents. Records in App E Available in PDR & Encl
Date released: 05/22/2020 Download: ML20129A284


Discusses Review to Estimate Production of Hydrogen by Radiolysis in Sf Storage Cask,Concluding That Radiolysis Not Significant Contributor to Hydrogen Gas Production at Point Beach & Not Expected to Be Source for Other Sf Storage Sys
ML20129B341
Person / Time
Site: Point Beach 
Issue date: 08/05/1996
From: Howe A
NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS)
To: STURZ F
NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS)
References
FOIA-96-322
Download: ML20129B341 (6)
Submits Response to Inquiries Re Temps Experienced Prior to Reflood of Msb & Whether Temps Could Possibly Exceed Qualified Temp of Carbonzinc 11 Coating on Interior Msb Surfaces
ML20129B325
Person / Time
Issue date: 07/26/1996
From: Castell C
WISCONSIN ELECTRIC POWER CO.
To: HOWELL A G
NRC
References
FOIA-96-322
Download: ML20129B325 (1)
Requests That C Interrante Respond Directly Re Whether or Not C Interrante Inspected Burn Temp.If Burn Temp Not Inspected,Inform NRR as Part of Response That Objectives of Sierra Insp Were to Review Design Process as Implemented
ML20129A557
Person / Time
Issue date: 07/24/1996
From: Jankovich J
NRC
To: STURZ F C
NRC
References
FOIA-96-322
Download: ML20129A557 (1)
Informs That C Interrante Inspected Coating & That Question Re Burn Temp Not Addressed During Visit to Sierra,However, C Interrante Must Provide Confirmation.Request to Be Forwarded to F Sturz for Instruction on How to Respond
ML20129A525
Person / Time
Issue date: 07/24/1996
From: Jankovich J
NRC
To: RECKLEY W
NRC
References
FOIA-96-322
Download: ML20129A525 (1)
Forwards Draft Response to Shillinglaw Ltr to Chairman for Comments/Corrections & Inquires If NMSS Discussed W/Vendor Whether 1300F Value in SAR Verified by Carboline During Sierra Insp or What Value Was in Purchase Specification
ML20129A489
Person / Time
Issue date: 07/24/1996
From: William Reckley
NRC
To: ENG P, JANKOVICH J P, STURZ F
NRC
References
FOIA-96-322
Download: ML20129A489 (1)
Discusses Estimate of over-pressure for Both Deflagration & Detonation.Pressures for Detonation Deemed to Be Higher than for Deflagration,But Not High in Terms of Matls Designed to Create High Pressures & Shock Waves
ML20129A447
Person / Time
Issue date: 07/02/1996
From: Stokley J
SCIENCE APPLICATIONS INTERNATIONAL CORP. (FORMERLY
To: LEEDS E
NRC
References
FOIA-96-322
Download: ML20129A447 (1)
Discusses Max over-pressure Achievable on Burning of hydrogen-air Mixtures,In Response to Burning of Hydrogen Gas That Occurred During Weld Closure of Sf Storage Casks
ML20129A359
Person / Time
Issue date: 07/01/1996
From: Stokley J
SCIENCE APPLICATIONS INTERNATIONAL CORP. (FORMERLY
To: LEEDS E J
NRC
References
FOIA-96-322
Download: ML20129A359 (6)
Informs of ANO Expectation to Meet Terms of CAL by Next Week & Start Moving Fuel by 960708
ML20129A316
Person / Time
Issue date: 06/14/1996
From: Beckner W
NRC
To: MARCUS G H
NRC
References
FOIA-96-322
Download: ML20129A316 (43)
Fourth Partial Response to FOIA Request for Documents. Records in App E Available in PDR & Encl
ML20129A278
Person / Time
Site: Point Beach 
Issue date: 10/09/1996
From: Racquel Powell
NRC OFFICE OF ADMINISTRATION (ADM)
To: DUMS D
AFFILIATION NOT ASSIGNED
References
FOIA-96-322
Download: ML20129A278 (3)