ML20128P991

From kanterella
Jump to navigation Jump to search
Part 21 Rept Re Colt Industries Emergency Diesel Generator Set Failure During Overspeed Tests Following Diesel Engine Overhaul.Initially Reported on 850517.Louis Allis Representative Sent to Site to Evaluate Failure
ML20128P991
Person / Time
Site: Calvert Cliffs  
Issue date: 05/21/1985
From: Leusink H
LOUIS ALLIS CORP. (DIV. OF MAGNETEK, INC.)
To: Murley T
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
REF-PT21-85, REF-PT21-85-255-000 PT21-85-255, PT21-85-255-000, NUDOCS 8506040035
Download: ML20128P991 (1)


Text

-

ALouisAllis A Wd Magrwie Fc 427 E. Stewart St., P.O. Box 2020, Milwaukee, WI 53201-2020 414-481-6000 TWX 910-262-3115 May 21, 1985 Dr. Thomas E. Murley U. S. Nuclear Regulatory Commission Region I 631 Park Avenue King of Prussia, Pennsylvania 19406

Subject:

10CFR 21 - BG&E - Calvert Cliffs

Dear Dr. Murley:

This letter is a follow-up of my telephone notification to your department on May 17, 1985 concerning the subject installation.

On May 15,-1985 Louis Allis was informed by Baltimore Gas and Electric personnel at Calvert Cliffs Nuclear Power Generation Plant that a failure had occurred to one of the emergency diesel generator sets manufactured by Colt Industries in 1970. The Electrical Division of Colt was sold in 1973 to a private investor and renamed Beloit Power Systems.

In 1979 Louis Allis purchased Beloit Power Systems and that is the reason Lo is Allis was notified of the failure.

The failure occurred during overspeed tests on the set following a diesel engine overhaul. The circumstances of the test are not known at this time so an evaluation of the cause is not possible. The diesel engine manufacturer is Colt Industries of Beloit, Wisconsin.

Louis Allis has sent a representative to the site to evaluate the failure and a follow-up report will be filed when the information has been received and analyzed.

Sincerely, Ag;21 u H. H. Leusink Vice President, Engineering HHL:sd cc: Louis Allis:

Colt Industries:

Mr. E. Klessig Mr. Chuck Ankrum Mr. J. Borman Mr. Richard Keyser Mr. A. Giesecke Mr. H. Shcreiber 8506040035 850521 PDR ADOCK 05000317 S

PDR Il0 0

&