Text

_.

1 October 11, 1996 5

Mr. Donald Schnell Senior Vice President - Nuclear Union Electric Company Post Office Box 149.

}

.St. Louis, Missouri 63166 4

SUBJECT:

CALLAWAY PLANT, UNIT 1 - INSERVICE INSPECTION PROGRAM, REQUEST TO i

USE CODE CASE N-533 AS AN ALTERNATIVE TO CODE REQUIREMENTS

{

(TAC NO. M96544) l l

Dear Mr. Schnell:

By letter dated September 18, 1996, as supplemented by letter dated September 30, 1996, Union Electric Company (the licensee) requested approval for the implementation of the alternative rules of ASME Section XI Code Case N-533, entitled " Alternative Requirements for VT-2 Visual Examination of Class i

1 Insulated Pressure-Retaining Bolted Connections,Section XI, Division 1,"

pursuant to 10 CFR 50.55a(a)(3) to be applied to the Inservice Inspection (ISI) program for the Callaway Plant.

The staff concludes that the licensee's proposed alternative to use Code Case N-533 following a 4-hour hold time at normal operating pressure will i

continue to provide an acceptable level of quality and safety for the Callaway Plant. Therefore, the licensee's proposed alternative is authorized pursuant to 10 CFR 50.55a(a)(3)(1), provided that all requirements of Code Case N-533 are satisfied.

Use of Code Case N-533 is authorized for the second ten-year ISI interval or until such time as this code case is published in a future revision of Regulatory Guide 1.147. At that time, if the licensee intends to j

continue to implement this code case, the licensee is to follow all provisions

~

in Code Case N-533 with limitations issued in Regulatory Guide 1.147, if any.

l The staff's evaluaticn and conclusions are contained in the enclosed safety i

evaluation.

Sincerely, i

Original Signed by J. W. Clifford for William H. Bateman, Project Director Project Directorate IV-2 1

Division of Reactor Projects III/IV j

Office of Nuclear Reactor Regulation 1

Docket No. 50-483 DISTRIBUTION:

Docket:Filea KThomas

Enclosure:

Safety Evaluation PUBLIC ACRS, TWFN JRoe JMitchell cc w/ enc 1:

See next page JDyer, RIV EPeyton 0GC, 015B18 GHill (2), T5C3 EAdensam PDIV-2/RF WBateman GBagchi, ECGB 1

]

hhl 9610170048 961011 lJohnson' RIV hDR ADOCK 0500 3

DOCUMENT NAME:

CAL 96544.ISI

  • See Previous Sheet for Concurrence OFC PDIV-2/PM PDIV-2/LA BC/ECGB*

OGC PDIV-2fD k

NAME KThomY:ye-EPeyNn GBagchi MYoung*

WdtNn DATE 10/ tl /96 10/1@ /96 9/19/96 10/3/96 10/ 0 /96 160034 0FFICIAL RECORD COPY

Mr. D. F. Schnell October 11, 1996 cc w/ encl:

Professional Nuclear Mr. Neil S. Carns Consulting, Inc.

President and Chief Executive Officer 19041 Raines Drive Wolf Creek Nuclear >perating Corporation Derwood, Maryland 20855 P.O. Box 411 Burlington, Kansas 66839 Gerald Charnoff, Esq.

Thomas A. Baxter, Esq.

Mr. Dan I. Bolef, President Shaw, Pittman, Potts & Trowbridge Kay Drey, Representative 2300 N. Street, N.W.

Board of Directors Coalition Washington, D.C.

20037 for the Environment 6267 Delmar Boulevard Mr. H. D. Bono University City, Missouri 63130 Supervising Engineer, Site Licensing Mr. Lee Fritz Union Electric Company Presiding Commissioner Post Office Box 620 Callaway County Court House Fulton, Missouri 65251 10 East Fifth Street Fulton, Missouri 65151 U.S. Nuclear Regulatory Commission Resident Inspector Office Mr. Alan C. Passwater, Manager 1

8201 NRC Road Licensing and Fuels Steedman, Missouri 65077-1302 Union Electric Company Post Office Box 149 i

l Mr. G. L. Randolph, Vice President St. Louis, Missouri 63166 Nuclear Operations Union Electric company Mr. J. V. Laux, Manager i

P.O. Box 620 Quality Assurance Fulton, Missouri 65251 Union Electric Company i

Post Office Box 620 Manager - Electric Department Fulton, Missouri 65251 Missouri Public Service Commission 301 W. High Post Office Box 360 Jefferson City, Missouri 65102 Regional Administrator, Region IV U.S. Nuclear Regulatory Commission Harris Tower & Pavilion 611 Ryan Plaza Drive, Suite 400 Arlington,-Texas 76011-8064 Mr. Ronald A. Kucera, Deputy Director Department of Natural Resources P.O. Box 176 Jefferson City, Missouri 65102

.