e SAFETY EVALUATION REPORT FOR GENERIC LETTER 83-28, ITEM 1.1 - POST-TRIP REVIEW (PROGRAM DESCRIPTION AND PROCEDURE)

BRAIDWOOD STATION, UNITS-1 AND 2 DOCKET N05.: 50-456/457

. I.

INTRODUCTION 4

On February 25, 1983, both of the scram circuit breakers at Unit 1 of the Salem Nuclear Power. Plant failed to open upon an automatic reactor trip

. signal from the reactor protection system. This incident occurred during the

. plant start-up and the reactor was tripped manually by the operator about 30 seconds after the initiation of the automatic trip signal. The failure of the circuit breakers has been determined to be related to the sticking of the under voltage trip attachment. Prior to this-incident, on February 22,- 1983, at Unit 1 of the Salem Nuclear Power Plant, an automatic trip signal was generated based on steam generator low-low level-during plant start-up.

Ir this case, the reactor was tripped manually by the operator almost coincidentally with the automatic trip. Following these incidents, on February 28, 1983, the NRC Executive Director for Operations (ED0), directed the. staff to investigate and report on the generic implications of these occurrences at Unit 1 of the Salem Nuclear Power Plant. The results of the staff's inquiry into the generic implications of the Salem unit incidents are reported in NUREG-1000, " Generic Implications of ATWS Events at the Salem Nuclear Power Plant." As a result of this investigation, the Commission

- (NRC) requested (by Generic Letter 83-28 dated July 8, 1983) all licensees of operating reactors, applicants for an operating license, and holders of construction permits to respond to certain generic concerns.

These concerns are categorized into four areas:

(1) Post-Trip Review, (2) Equipment Classification and Vendor Interface, (3) Post-Maintenance Testing, and (4) Reactor Trip System Reliability Improvements.

The first action item, Post-Trip Review, consists of Action Item 1.1,

" Program Description and Procedure" and Action Item 1.2. " Data and Information Capability." This safety evaluation report (SER) addresses Action Item 1.1 only.

C506030122 850517 PDR ADOCK 05000456 A

PDR

  • wy t

'rww-vy y- - t w w

ym=-y rww-ww hrw-i w

ymy--11 y*---ev e

-y*w wyWww--

-y,,-9-w++y y-r y-9 m g w g 9+y-rw-9y y vg'-

yw w v* w -y y, y w,iew--rw5eg--ge-'E-1V-=*"f

'F=-

-"ed w'

.' II.

REVIEW GUIDELINES The following review guidelines were developed after initial evaluation of

,e various utility responses to item 1.1 of Generic Letter 83-28 and incorporate the best features of these submittals. As such, these review guidelines in effect represent a " good practices" approach to post-trip review.

We have reviewed the applicant's response to Item 1.1 against these guidelines:

A.

The licensee or applicant should have systematic safety assessment procedures established that will ensure that the following restart criteria are met before restart-is authorized.

The post-trip review team has determined the root cause and sequence of events resulting in the plant trip.

Near term corrective actions have been taken to remedy the cause of the trip.

The post-trip review team has performed en analysis and determined that the major safety systems responded to the event within specified limits of the primary system parameters.

The post-trip review has not resulted in the discovery of a potential safety concern (e.g., the roo't cause of the event occurs with a frequency significantly larger than expected).

If any of the above restart criteria-are not met, then an independent assessment of the event' is performed by the Plant Operations Review Committee (FORC), or another designated group with similar authority and experience.

B.

The responsibilities and authorities of the personnel who will perform the review and analysis should be well defined.

The post-trip review team leader should be a member of plant management.at the shift supervisor level or above and should hold or should have held an SR0 license on the plant. The team leader

-should be charged with overall responsibility for directing the post-trip review, including data gathering and data assessment and he/she should have the necessary authority to obtain all personnel and data needed for the post-trip review.

A second person on the review team should be an STA or should hold a relevant engineering degree with special transient analysis training.

4

~The team leader and the STA (Engineer) should be responsible to concur on a decision / recommendation to restart the-plant. A nonconcurrence from either of these persons should be sufficient to prevent restart until the trip has been reviewed by the PORC or equivalent organization.

C.

The licensee or applicant should indicate that the plant response to the trip event will be evaluated and a determination made as to whether the plant response was within acceptable limits ~. The evaluation should include:

A verification of the proper operation of plant systems and equipment by comparison of the pertinent data obtained during the post-trip review to the applicable data provided in the FSAR.

- An analysis of the sequence of events to verify the proper functioning of safety related and other important equipment. Where 4

pessible, comparisons with previous similar events should be made.

D.

The licensee or applicant should have procedures to ensure that all physical evidence necessary for an independent assessment is preserved.

4 E.

-Each licenseelor applicant should provide in its submittal, copies of the plant procedures which contain the information required in Items A

.through D. -As a minimum, these should include the following:

The criteria 'for determining' the acceptability of restart The~ qualifications, responsibilities and authorities of k.ey

' personnel involved in the post-trip review process The methods and criteria for determining whether the plant variables.and system responses were within the limits as described in the FSAR The-criteria for determining the need for an independent review.

~

III.

EVALUATION AND CONCLUSION By letter. dated November 5, 1983, the appl'icant of Braidwood Station, Units 1 and 2, provided information regarding its Post-Trip Review Program and Procedures. We.have evaluated the applicant's program and. procedures against the review guidelines developed as described in Section II. A brief description of,the epplicant's response and the staff's evaluation of the response against each of the review guidelines is provided below:

1 1

A.

With regard to the criteria for determining the acceptability of restart, the applicant referred to a Corporate Directive " Plant Startup Af'ter Trip," which provides guidance for post-trip analysis, determination of root cause and approval for startup. The applicant-indicated that prior to the authorization of restart, the Corporate Directive-requires: -a determination of the: root cause of the event; a satisfactory evaluation of equipment performance; and the cause of any degraded, abnormal, or unexpected performance of safety-related equipment to be understood. We find that the applicant's criteria for

=

c v4-g

-3,w.

.m e+,---.y.%.,,,

-n,.--

,.. -,ee,

.w

,-.,w

-.y-

.g

-e-


,-e-

,,,-,,-,,-m--,---we-----~


+,,.--,w.-.y-

. determining the acceptability of restart conform with the guidelines as described in the above Section II.A and, therefore, are acceptable.

B.

The applicant indicated that a Shift Supervisor han the responsibility and authority to obtain all necessary personnel ano any special assistance considered necessary to ensure a thorouga post-trip review..

The personnel performing the review and analysis wi'l be shift management personnel (i.e., Shift Engineer, Shift Fcreman and Station Control Room Engineer). These are all SR0 licensed thift positions. We find that the qualifications, responsibilities and authorities of the personnel who will authorize the restart and/or perform the post-trip review and analysis have been clearly defined and are.teceptable.

C.

The a'pplicant has not addressed the methods and criteri,3 for comparing the event information with known or expected plant behavior. We recomend that the pertinent data obtained during the pcst-trip review

~

be compared to the applicable data provided in the FSAR.

Where possible, comparisons with previous similar events shoultf be made.

D.

The applicant has not. addressed the criteria for the need of independent assessment of an event. We recomend that, if any of the above criteria for determining the acceptability of restart are not met, an independent assessment of the event be performed by the PORC or a group with similar authority and experience. However, the applicant has established procedures to ensure that all physical evidence necessary for an

-independent assessment is preserved.

E.

The applicant has not provided for our review a systematic safety assessment program to assess unscheduled reactor trips. We reconnend that the applicant develop a systematic safety assessment program to handle unscheduled reactor trips.

i

=

4 Acceptable responses to the above noted deficiencies are required before we can complete our review of the applicant's Post-Trip Review Program and

- Procedures for.Braidwood Station, llnits'I and 2.

We will review these responses when received and report our finding in a supplement to this SER.

4 i

J m

O 4

I J

+r=

e-e e4<-

e,_,, - - -- -

--m, r-----

--+r

<- - - < + - -+~<---- - -

+-+v-3

--e y

-- er w --,, rye--

e D '

SALP EVALUATION BRAIDWOOD STATION, UNITS 1 AND 2 DOCKET N05. 456/457 GENERIC LETTER 83-28 ITEM 1.I POST TRIP REVIEW A.

-Functional Areas: Licensing Activities - Generic Letter 83-28, Item 1.1, Post Trip Review 1.

Management involvement in assuring quality Based on our review of the applicant's response to Generic Letter 83-28 and providing that the applicant will resolve our concerns as described in the SER, the licensee will have an effective systematic assessment procedure to assess unscheduled i

reactor trips.

Rating: Category 2 1

2.

Approach to resolution of technical issues from a safety standpoint Rating: N/A 3.

Responsive to NRC initiatives Based on our review, we find that the applicant was not completely responsive to NRC initiatives.

Rating: Category 2