Enclosure EVALUATION OF THE USE OF LYNX 1 & 2 WITH B&W-2 CORRELATION INTRODUCTION In Reference 1, B&W requested that the LYNX 1/2 computer codes be approved for use with the NRC approved B&W-2 CHF correlation to evaluate DNBR margins in licensing submittals.
EVALUATION Reference 2 provides a comparative analysis which demonstrates that the use of B&W-2 is appropriate for DNBR evaluations using the LYNXT code. Reference 3 and 4 provide comparative analyses which demonstrate that LYNX 2 and LYNXT are equivalent when used for DNBR calculators.
In addition, in Reference 5 B&W provided justification for the use of the B&W-2 CHF correlation, with a 95/95 correlation limit of 1.30, in analyses perfonned with the LYNX 2 code. The staff has reviewed these documents and has found that the B&W-2, LYNX 1/2 combination is acceptable for evaluating DNBR margins in licensing submittals. Should B&W in the future wish to use LYNX 1/2 with CHF correlations other than B&W-2 or BWC, justification similar to that provided for B&W-2 must be reviewed and approved by the staff. The approval of a CHF correlation alone is not sufficient to allow the use of that correlation with any approved T-H analysis code.
0507110699 850701
{DR TOPRP ENVBW PDR
References:
1.
Letter,J.H. Taylor (B&W) toc.O. Thomas (NRC)datedSeptember 26, 1984.
2.
Letter, J. H. Taylor (B&W) to C. O. Thomas (NRC) dated August 27, 1984.
3.
R. L. Harne & J. H. Jones, " Thermal-Hydraulic Crossflow Applications,"
BAW-1892, Babcock & Wilcox, April 1984.
4.
Letter, J. H. Taylor to C. O. Thomas, " Request Number One for Additional Information - BAW-10156, May 4, 1984," July 2, 1984.
5.
Letter, J. H. Taylor to C. O. Thomas, "Use of B&W 2 Correlation in LYNX 2,"
May 9, 1985.
,