,_

[

UNITED STATES 8-g NUCLEAR REGULATORY COMMISSION 5

.j WASHINGTON, D. C. 20555

/

JUN 2 61985 Docket No. 50-450 Mr. William J. Cahill, Jr.

Senior Vice President River Bend Nuclear Group Gulf States Utilities Company Post Office Box 2951 Beaumont, Texas 77704 ATTN: Mr. J. E. Bcoker

Dear fir. Cahill:

SUbdECT: FEMA INTERIM FINDING'S Of: 0FFSITE RADIOLOGICAL EMERGENCY RESF0 HSE FLAf,5 FOR RIVER BEND STATION TFe erclosed memorandun fron Richard W. Krimm, FEMA, dated May 10, 1985 forwards FEMA's third interirn finding on offsite radiological ereergency response plans for the River Bend Luclear Generating Station.

FFMA indicates that although several elements in the plans remain inadequate, the offsite emergency plens arid preparedness are adequate to provide reasonable assurance that appropriete rusures can be taken to protect the health and safety of the pubiic in the event of an accident at River Bend. The FEMA Region will reaintain close liaison with the State of Louisiana to resolve the remaining inacequacies.

FEMA has advised NPC that a finding addressing the retaining inacequacies will be provided by Jure 30, 1985.

We request that you continue to coordinate planning efforts with those of the state to ensure that the remaining inadequacies in the offsite emergency plans identifieo by FEMA are corrected.

8507110427 850626 PDR ADOCK 05000458 F

PDR

Please contact the NRC Project Mariger, Stephen Stern for claritication or futther discussion on this topic.

Sir.cerely, Mninni stened by t Walter R. Butler, Chief Licensing Branch lio. 2 Division of Licer.sira

Enclosure:

As stated cc: David B.1:atthews, IE D. Perotti, IE DISTRIBUTION

? Docket File NRC PCR Local PDR PRC Systen NSIC LC/ 2. Reac'ing EHylton SStern Du.ey OELD ACRS (,16)

JPartlow BGrimes EJordan

)I LB#

L/PM LB#2/DL/BC4 55 ei alb t.'Bu tl er 06/Lf/85 064Y85

s 2_

Please contoct the hhl hyect l'.enager, Stephen Stern for clarification or furtht.r ciscussion on this topic.

Sincerely, 1; alter R. Butler, Chief Licensing Branch f;o. 2 Division of Licensir.g Encicsure:

As stateo cc; Davic E. I;/ttFcvs, IE D. Perotti, IE

s l.r. llillitn J. Cehill, Jr.

River Bend f,'uclear Plant Gulf States Utilities Company cc: Troy B. Conner, Jr., Esq.

Ms. Linda 6. Watkins/Mr. Steven Irving Conner and Wetterhahn Attorney at Law 1747 Pennsylvania Avenue,fi. W.

355 Napoleon Street Washington, D.C.

20006 Batcr. houge, Louisiana 70802 Nr. William J. Reed, Jr.

Director - fiuclear Licensing Gulf States Utilities Cortpany Post Office Box 2951 L'ccur:.cnt, Texas 77704 Nr. David 7alcudek Nuclear Energy Division E. Anne Piettinger Louisiana Departr.ient of 3456 Villa Rose Dr.

Environnental (uolity Baton Rouge, Louisiena 70EC6 Post Office Box 14690 Baton Rouge, Louisiana 70898 Richarc H. Troy, Jr., Esq.

Assistant Attorney General in Charge State of Leviticrr. Ocpartnent of Justice 234 Loyola Avenue liew Orleans, Louisiana, 7011'i l'r. J. David McNeill, III Dwight D. Chamberlain William G. Davis, Esq.

Resider.t Ir.spector Department of Justice Post Office Box 105*.

Attorney General's Office St. Francisville, Louisiar.a 70775 7434 Perkins Roao Baton Rouge, Louisiara 7CL00 Gretchen I;. 1:othschild Louisianians for Saft. Er.orCy, Inc.

1659 Glenmore Avenue Baton houge, Louisiana 70775 James W. Pierce, Jr., Esq.

P. O. Box 23571 Baton Rouge, Louis 1 aria 70093 fir. Robert D. Martin U.S. NRC, Region IV Parkwy Central Plaza Building 611 Ryan Plaza Drive, Sutic 1000 Arlington, Texas 76011 l

3 jR f

g Federal Emergency Management Agency Washington, D.C. 20472 MAY I 01985 MEMORANDUM FOR:

Edward L. Jordan Director, Division of Emergency Pre aredness and Engineering Response

~

FROM:

Ri ard r

' ~ ~ ~

Assistant Associate Director Natural and Technological Hazards Programs

SUBJECT:

Third Interim Finding on Offsite Radiological Emergency Response Plans for the River Bend Nuclear Generating Station

^

Attached is a copy of the third interim finding on the adequacy of the Louisiana Peacetime Radiological Response Plan (Revision V) site-specific to the River Bend Nuclear Generating Station.

This report was prepared by the Region VI staff of the Federal Emergency Management Agency.

This third interim finding indicates a great improvement in the radiological emergency preparedness plans since the supplemental finding submitted to you on February 12, 1985.

The NUREG-0654/ FEMA REP-1, Rev.1, elements remaining inadequate for the State of Louisiana are G.3.a., J.10.e., L.3., and P.10., and for the Parishes, J.10.e.

The Region will maintain close liaison with the State of Louisiana to ensure that the remaining inadequacies are completed to FEMA's satisfac-tion.

Based on the final report of the initial qualifying exercise on offsite radiological emergency preparedness conducted on January 16,1985, which was transmitted to you by memorandum dated May 7, 1985, and the review of the plans, the offsite radiological emergency plans and preparedness are adequate to provide reasonable assurance that appropriate measures can be taken to protect the health and safety of the public in the event of an accident at the River Bend Nuclear Generating Station.

Should you have any questions, please contact Mr. Robert S. Wilkerson, Chief, Technological Hazards Division, at 646-2861.

b

~

Attachment o

as stated

LOUISI AN A PEACETIME - RADIOLOGIC Al. RESPONSE PLAN (Revision 5, December,1983)

Third Interim Finding April 1,1965 State Plan-River Bend Station The following is a list of those NUREG-0654 elements which were previously evaluated as inadequate as a result of the second interim finding dated December 14, 1984. This third interirn finding illustrates the progress made towards resolv-ing those NUREG-0654 elements.

E.2.

FEMA Evaluation Comment Internal procedures for alerting, notifying, and mobilizing emergency response personnel were not available for review (page 17). Implementing procedures not available for review.

Action Taken by the State of Louisiana State implementing procedures were submitted to FEMA Region Vi for review.

Present Status - RESOLVED - Implementing procedures have been reviewed by FEMA Region VI and are considered adequate.

E.5.

FEMA Evaluation Comment implementing procedures were not available for review (pages 44-48) pertaining to the alert and notification system.

Action Taken by the State of Louisiana State implementing procedures were submitted to FEMA Region VI for review. Also, refer to parish implementing procedures.

Present Status - RESOLVED - Both State and parish implement-ing procedures have been reviewed by FEMA Region VI and are now considered adequate.

l E.7.

FEMA Evaluation Comment Plan does not provide for draft written messages for public.

Action Taken bv the State of Louisiana l

Parish implementing procedures were submitted to FEMA l

Region Vi for review. The "public alert" section included all draft messages as required.

Present Status - RESOLVED - Implementing procedures have been reviewed by FEMA Region VI and are now considered adequate.

G.3.a.

FEMA Evaluation Comment No physical location was identified for the news media center.

l

3 Action Taken by the State of Loulslana State of Louisiana has not submitted to FEMA Region VI the proper description of where the news media center is located.

This additional clarification is to be written in the public in-formation portion of the state plan.

Present Status - INADEQUATE - FEMA Region Vi has not received in written description of where the news media center is located.

H.4.

FEMA Evaluation Comment No implementing procedures available for review.

Action Taken by the State of Louisiana State implementing procedures were submitted to FEMA Region VI for review.

Present Status - RESOLVED - The implementing procedures have been reviewed by FEMA, Region VI and are considered adequate.

l.8.

FEMA Evaluation Comment No implementing procedures available for review. No depicy-ment times given (pp. 55-61).

Action Taken bv the State of thuisiana State implementing procedures were submitted to FEMA Region VI for review.

Present Status - RESOLVED - The implementing procedures have been reviewed by FEMA, Region V!/RAC and are considered adequate.

1.10.

FEMA Evaluation Comment No implementing procedures available for review.

Action Taken by the State of Louisiana State implementing procedures were submitted to FEMA Region VI for review.

Present Status - RESOLVED - The implementing procedures have been reviewed by FEMA Region Vl/RAC and are considered adequate.

J.10.e.

FEMA Evaluation Comment Plan does not contain outline of where K1 is to be stored; dis-tribution to be made by LNED.

Action Taken by the State of Louisiana Policy concerning potassium iodide (KI) is presently being re-evaluated. This criterion will be addressed and included in the next revision of the Attachment which is to be submitted to the RAC as part of the "350" process, after the exercise.

2

4 Present

  • Status - INADEdUATE - FEMA. Region Vi has not received any update on KI policy.

J.10.k.

FEMA Evaluation Con ment Potential impediments along main evacuation routes will be implemented according to Parish enclosures.

Implementing procedures were not available for review (Basic Plan, pg 66).

Action Taken by the State of Louisiana State implementing procedures were submitted to FEMA Region Vi for review.

Present Status - RESOLVED - Implementing procedures for the Department of Transportation and Development have been reviewed by FEMA Region VI and are considered adequate.

K. 3.b.

FEMA Evaluation Comment Implementing procedures were not available for review con-cerning monitoring of emergency worker doses.

Action Taken by the State of Louisiana State implementing procedures were submitted to FEMA Region Vi for review.

Present Status - RESOLVED - The implementing procedures have been reviewed by FEMA Region Vl/RAC and are considered adequate.

i K.5.b.

FEMA Evaluation Comment Means for decontamination specified in implementing procedures not available for review. Means for waste disposal not ad-dressed.

Action Taken by the State of Louisiana State implementing procedures were submitted to FEMA Region i

VI for review.

l Present Status - RESOLVED - The implementing procedures l

have been reviewed by FEMA Region Vl/RAC and are considered adequate.

L 3.

FEMA Evaluation Comment The hospital list does not include the type of facility, capacity and any special radiological capabilities.

Action Taken by the State of Louisiana Information to address this element is being accumulated at.

this time.

Present Status - INADEQUATE - FEMA Region Vi has not received the required hospital information.

P.10 FEMA Evaluation Comment No implementing procedures available for review for compli-ance.

3

Action Taken bv the State of Louisiana State implementing procedures were submitted to FEMA Region VI for review.

Present Status - INADEOUATE - Nothing stated in implement-ing procedures about insuring that telephone numbers are up-dated at least quarterly.

.g(

t

=

9 4

e f

f J- '1 x

't f

  • i 3

a

'a

?.

t f

4' 4

.1 I

t l

l l

s i

I l

l

LOUISIANA GENERAL' AND PARISH RADIOLOGICAL EMERGENCY RESPONSE PLANS (Attachment 3, December 1983)

Third Interim Findina April 1,1985 Parish Plans - River Bend Station The following is e !!st of those NUREG-0654 elements which were previously evaluated as inadeauate as'a result of the second interim finding dated December 14, 1984. This third interim finding illustrates the progress made towards resolv-ing those NUREG-0654 elements. Note that only J.10.e. remains inadequate.

E.2 FEMA Evaluation Comment Parish plans do describe the notification and activation, but specific internal procedures for each organization were not available for review. A listing of implementing procedures was given in Appendix 1-3.

Implementing procedures not in-cluded for review.

Action Taken By the State of Louisiana Parish implementing procedures were submitted to FEMA Region VI February 2.5, 1985.

Present Status - RESOLVED - Implementing procedures have been received and reviewed by FEMA and are considered ade-quate.

E.7.

FEMA Evaluation Comment Parish plans did not include written messages intended for the public consistent with the licensee's classification scheme.

There is only a listing of those EBS messages on page 12 of General Plan.

Action Taken by State of Louisiana Written EBS messages for the public were submitted to FEMA Region VI for review.

Present Status - RESOLVED H.4.

FEMA Evaluation Comment Parish plans do address activation and staffing according to established procedures.

However, no Parish implementing procedures are available for review.

Action Taken by State of Louisiana Parish implementing procedures were submitted to FEMA Region VI February 25,1985.

m, Presen't Status - RESOLVED - Parish implementing procedures have been reviewed by FEMA and are considered adequate.

].10.e.

FEMA Evaluation Comment No reference as to where potassium iodide (KI) is stored; dis-tribution to be made by LNED, Action Taken by State of Loulslana Policy concerning potassium iodide (KI) is presently being re-evaluated. This criterion will be addressed and included in the next revision of the Attachment which is to be submitted to the RAC as part of the "350" process, after the exercise.

Present Status - INADEQUATE - FEMA Region Vi has not received any update on KI policy.

e 0

8 l

[

t I

2