ML20128K356

From kanterella
Jump to navigation Jump to search
Change Notice 1 to Primary Reactor Containment Integrated Leak Rate Test,Final Rept
ML20128K356
Person / Time
Site: Arkansas Nuclear Entergy icon.png
Issue date: 12/17/1984
From:
ARKANSAS POWER & LIGHT CO.
To:
Shared Package
ML20128K336 List:
References
NUDOCS 8507240106
Download: ML20128K356 (63)


Text

-.

I l

s' l

e l

Arkansas Nuclear One, Unit 1 j

Primary Reactor Containment ILRT Final Report Change Notice No.1 l

j December 17,198Y NOTE: To all recipients of Arkansas Nuclear One, Unit 1 Primary Reactor l

Containment Integrated Leakage Rate Test Final Report. Remove following pages from the final report and insert the attached pages into the report.

Pase No.

Description 11 Table of Contents B-2 thru B-17 ILRT Stabilization Summary Data C-5 thru C-34 ILRT Summary Data G-2 thru G-18 Verification Flow Test Summary Data After making the above insertions, place this change notice in the report as page iv.

8507240106 85071ti PDR ADOCK 05000313 P

PDR SU-077 iv


A

s' e

.)

TABLE OF CONTENTS Section g

I.

INTRODUCTION 1

i II.

TEST SYNOPSIS 2

III. TEST DATA

SUMMARY

4 IV.

ANALYSIS AND INTERPRETATION 9

V.

COMPUTER REPORT / DATA PRINTOUT DEFINITIONS 10 VI.

REFERENCES 12 Appendix A.

Bechtel ILRT Computer Program Summary B.

ILRT Stabilization Summary Data C.-

ILRT Summary Data O

D.

ILRT Calculations Trend Report Mass Point Analysis Total Time Analysis E.

ILRT Plots Temperature vs Time Pressure vs Time Vapor Pressure vs Time Air Mass vs Time Mass Point Leakage Rate vs Time r

Total Time Leakage vs Time F.

Verification Flow Test Stabilization Data G.-

Verification Flow Test Summary Data H.

Verification Flow Test Calculations Total Time Analysis Mass Point Analysis Plot: Air Mass vs Time I

I.

Results of Local Leakage Rate Test i O SU-077 11 1

b I

3'

SUMMARY

OF MEASURED DATA AT 1230 1216 TEMP 1 = 532.8800

(

73.210 )

TEMP 2 = 531.7100

(

72.040 )

TEMP 3 = 529.0500

(

69.380 )

TEMP 4 = 533.3600

(

73.690 )

TEMP 5 = 533.4800

(

73.810 )

TEMP 6 = 534.5400

(

74.870 )

TEMP 7 = 536.4000

(

76.730 )

TEMP 8 = 532.9000

(

73.230 )

TEMP 3 = 533.0500

(

73.380 )

TEMP 10 = 533.0800

(

73.410 )

TEMP 11 = 533.7500

(

74.080 )

TEMP 12 = 533.1100

(

73.440 )

1 TEMP 13 = 533.3900

(

73.720 )

TEMP 14 = 533.2200

(

73.550 )

TEMP 15 = 533.1800

(

73.510 )

TEMP 16 = 532.8700

(

73.200 )

TEMP 17 = 533.0700

(

73.400 )

TEMP 18 = 533.0800

(

73.410 )

PRES 1 =

73.7867

( 74255.0 )

PRES 2=

73.7734

( 72557.0 )

VPRS 1 =

.3148

(

65.870 )

VPRS 2=

.3144

(

65.830 )

VPHS 3=

.3121

(

65.620 )

VPRS 4 =

.3081

(

65.250 )

VPRS 5=

.3192

(

66.270 )

VPRS 6=

.3114

(

65.550 )

SUMMARY

OF CORRECTED DATA TIME = 1230 DATE = 1216 TEMPERATURE (DEGREES R.)

=

533.0273 CORRECTED PRESSURE (PSIA) 73.4736

=

VAPOR PRESSURE (PSIA) =

.3132 VOLUME (CU.FT.) = 1910000.0 AIR MASS (LBM) 710630.2

=

f3 V

B-2 L

i

s'

SUMMARY

OF MEASURED DATA AT 1245 1216 TEMP 1 = 532.6000

(

72.930 )

TEMP 2 = 531.5800

(

71.910 )

TEMP 3 = 528.9200

(

69.250 )

TEMP 4 = 533.2100

(

73.540 )

TEMP 5 = 533.3900

(

73.720 )

TEMP 6 = 534.3400

(

74.670 )

TEMP 7 = 536.2300

(

76.560 )

TEMP 0 = 532.8400

(

73.170 )

TEMP-9 = 532.9100

(

73.240 )

TEMP 10 = 532.8400

(

73.170 )

TEMP 11 = 533.6500

(

73.980 )

TEMP 12 = 532.9800

(

73.310 )

1 TEMP 13 = 533.1000

(

73.430 )

TEMP 14 = 532.8900

(

73.220 )

TEMP 15 = 532.9600

(

73.290 )

TEMP 16 = 532.7100

(

73.040 )

TEMP 17 = 532.8100

(

73.140 )

TEMP 18 = 532.8500

(

73.180 )

PRES 1

73.7619

( 74230.0 )

=

PRES 2=

73.7490

( 72533.0 )

VPRS 1

.3031

(

64.780 )

=

VPRS 2=

.3139

(

65.780 )

VPRS 3=

.3168

(

66.050 )

VPRS 4=

.3070

(

65.150 )

VPRS 5=

.3200

(

66.340 )

VPRS 6=

.3062

(

65.070 )

SUMMARY

OF CORRECTED DATA TIME = 1245 DATE = 1216 TEMPERATURE (DEGREES R.)

532.8250

=

73.4490 CORRECTED PRESSURE (PSIA)

=

.3129 VAPOR PRESSURE (PSIA)

=

VOLUME (CU.FT.)

1910000.0

=

AIR MASS (LBM) =

710662.6 s-

SUMMARY

OF MEASURED DATA AT 1300 1216 TEMP 1 = 532.7100

(

73.040 )

TEMP 2 = 531.6200

(

71.950 )

TEMP 3 = 528.9400

(

69.270 )

TEMP 4 = 533.1000

(

73.430 )

TEMP 5 = 533.3600

(

73.690 )

TEMP 6 = 534.1800

(

74.510 )

TEMP 7 = 536.0400

(

76.370 )

TEMP 8 = 532.6000

(

73.130 )

TEMP 9 = 532.8800

(

73.210 )

TEMP 10 = 532.6900

(

73.020 )

TEMP 11 = 533.5300

(

73.860 )

TEMP 12 = 532.7900

(

73.120 )

1 TEMP 13 = 532.9000

(

73.230 )

TEMP 14 = 532.7300

(

73.060 )

TEMP 15 = 532.8200

(

73.150 )

TEMP 16 = 532.5200

(

72.850 )

TEMP 17 = 532.7100

(

73.040 )

TEMP 18 = 532.7000

(

73.030 )

PRES 1

73.7460

( 74214.0 )

=

PRES 2=

73.7327

( 72517.0 )

VPRS 1 =

.3066

(

65.110 )

VPRS 2=

.3136

(

65.760 )

VPRS 3=

.3163

(

66.000 )

VPRS 4=

.3066

(

65.110 )

VPRS 5=

.3185

(

66.200 )

VPRS 6=

.3080

(

65.240 )

SUMMARY

OF CORRECTED DATA TIME = 1300 i

DATE = 1216 l

TEMPERATURE (DEGREES R.)

532.713d

=

CORRECTED PRESSURE (PSIA) 73.4333

=

VAPOR PREESURE (PSIA)

.3127

=

VOLUME (CU.FT.) = 1910000.0 AIR MASS (LBM) 710659.8

=

5

\\

)

v B-4 l

,a

SUMMARY

OF MEASURED DATA AT 1315 1216 e

TEMP 1 = 532.5900

(

72.920 )

TEMP 2 = 531.6000

(

71.930 )

TEMP 3 = 529.0300

(

69.360 )

TEMP 4 = 533.0300

(

73.360 )

TEMP 5 = 533.2300

(

73.560 )

TEMP 6 = 534.0600

(

74.390 )

TEMP 7 = 536.0600

(

76.390 )

TEMP 8 = 532.8200

(

73.150 )

TEMP 9 = 532.7900

(

73.120 )

TEMP 10 = 532.6000

(

72.930 )

TEMP 11 = 533.4800

(

73.810 )

TEMP 12 = 532.7100

(

73.040 >

1 TEMP 13 = 532.7600

(

73.090 )

TEMP 14 = 532.6300

(

72.960 )

TEMP 15 = 532.7800

(

73.110 )

TEMP 16 = 532.3800

(

72.710 )

TEMP 17 = 532.6100

(

72.940 )

TEMP 18 = 532.6100

(

72.940 )

PRES 1

73.7331

( 74201.0 )

=

PRES 2=

73.7195

( 72504.0 )

VPRS 1

.2940

(

63.910 )

=

VPRS 2=

.3136

(

65.760 )

VPRS 3=

.3143

(

65.820 )

VPRS 4=

.3068

(

65.130 )

VPRS 5=

.3160

(

65.980 )

VPRS 6=

.3077

(

65.210 )

SUMMARY

OF CORRECTED DATA TIME = 1315 DATE = 1216 TEMPERATURE (DEGREES R.)

532.6271

=

CORRECTED PRESSURE (PSIA) 73.4212

=

VAPOR PRESSURE (PSIA)

.3119

=

VOLUME (CU.FT.)

1910000.0

=

AIR MASS (LBM) 710657.7

=

1 o%

L._)

1 B-5

SUMMARY

OF MEASURED DATA AT 1330 1216

.3 TEMP 1 = 532.5000

(

72.830 )

TEMP 2 = 531.5700

(

71.900 )

TEMP 3 = 528.7700

(

69.100 )

TEMP 4 = 532.9100

(

73.240 )

TEMP 5 = 533.2500

(

73.580 )

TEMP 6 = 533.9600

(

74.290 )

TEMP 7 = 536.0000

(

76.330 )

TEMP 8 = 532.5900

(

72.920 )

TEMP 9 = 532.6600

(

72.990 )

TEMP 10 = 532.5100

(

72.840 )

TEMP 11 = 533.4000

(

73.730 )

TEMP 12 = 532.5900

(

72.920 )

1 TEMP 13 = 532.6500

(

72.980 )

TEMP 14 = 532.5600

(

72.890 )

TEMP 15 = 532.7000

(

73.030 )

TEMP 16 = 532.3300

(

72.660 )

TEMP 17 = 532.5200

(

72.850 )

TEMP 18 = 532.5600

(

72.890 )

PRES 1 =

73.7222

( 74190.0 )

PRES 2=

73.7093

( 72494.0 )

VPRS 1 =

.2958

(

64.080 )

VPRS 2=

.3117

(

65.580 )

VPRS 3=

.3119

(

65.600 )

VPRS 4 =

.3046

(

64.920 )

VPRS 5=

.3144

(

65.830 )

VPRS 6=

.3047

(

64.930 )

SUMMARY

OF CORRECTED DATA TIME = 1330 DATE = 1216 TEMPERATURE (DEGREES R.) =

532.5450 CORRECTED PRESSURE (PSIA) 73.4125

=

VAPOR PRESSURE (PSIA) =

.3097 VOLUME (CU.FT.) = 1910000.0 AIR MASS (LBM) =

710682.9

)

\\._./

B-6

SUMMARY

OF MEASURED DATA AT 1345 1216 TEMP 1 = 532.5800

(

72.910 )

TEMP 2 = 531.5500

(

71.880 )

TEMP 3 = 529.0200

(

69.350 )

TEMP 4 = 532.8600

(

73.190 )

TEMP 5 = 533.1400

(

73.470 )

TEMP 6 = 533.9100

(

74.240 )

TEMP 7 = 535.9500

(

76.280 )

TEMP 8 = 532.5800

(

72.910 )

TEMP 9 = 532.6400

(

72.970 )

TEMP 10 = 532.4600

(

72.790 )

TEMP 11 = 533.3500

(

73.680 )

TEMP 12 = 532.5100

(

72.840 )

1 TEMP 13 = 532.6000

(

72.930 )

TEMP 14 = 532.4800

(

72.810 )

TEMP 15 = 532.6300

(

72.960 )

TEMP 16 = 532.2800

(

72.610 )

TEMP 17 = 532.4400

(

72.770 )

TEMP 18 = 532.4600

(

72.790 )

PRES 1 =

73.7143

( 74182.0 )

PRES 2=

73.7002

( 72485.0 )

VPRS 1

.2977

(

64.260 )

=

VPRS 2=

.3130

(

65.700 )

6 VPRS 3=

.3140

(

65.790 )

VPRS 4 =

.3068

(

65.130 )

VPRS 5=

.3124

(

65.650 )

VPRS 6=

.3064

(

65.090 )

SUMMARY

OF CORRECTED DATA TIME = 1345 DATE = 1216 TEMPERATURE (DEGREES R.)

532.4950

=

CORRECTED PRESSURE (PSIA) 73.4035

=

VAPOR PRESSURE (PSIA)

.3108

=

VOLUME (CU.FT.)

1910000.0

=

AIR MASS.(LBM) 710662.1

=

IT

(_)

B-7

e

SUMMARY

OF MEASURED DATA AT 1400 1216 6

TEMP 1 = 532.5300

(

72.860 )

TEMP 2 = 531.5500

(

71.880 )

TEMP 3 = 528.9100

(

69.240 )

TEMP 4 = 532.8200

(

73.150 )

TEMP 5 = 533.1000

(

73.430 )

TEMP 6 = 533.9100

(

74.240 )

TEMP 7 = 535.8900

(

76.220 )

TEMP 8 = 532.4800

(

72.810 )

TEMP 3 = 532.6300

(

72.960 )

TEMP 10 = 532.4100

(

72.740 )

TEMP 11 = 533.3200

(

73.650 )

TEMP 12 = 532.5300

(

72.860 )

1 TEMP 13 = 532.5800

(

72.910 )

TEMP 14 = 532.4200

(

72.750 )

TEMP 15 = 532.5700

(

72.900 )

TEMP 16 = 532.1700

(

72.500 )

TEMP 17 = 532.3800

(

72.710 )

TEMP 18 = 532.4000

(

72.730 )

PRES 1 =

73.7073

( 74175.0 )

PRES 2=

73.6930

( 72478.0 )

VPRS 1 =

.3097

(

65.400 )

VPRS 2=

.3119

(

65.600 )

VPRS 3=

.3121

(

65.620 )

VPRS 4=

.3032

(

64.790 )

VPRS 5=

.3158

(

65.960 )

VPRS 6=

.3064

(

65.090 )

SUMMARY

OF CORRECTED DATA TIME = 1400 DATE = 1216 TEMPERATURE (DEGREES R.)

=

532.4492 CORRECTED PRESSURE (PSIA) 73.3972

=

VAPOR PRESSURE (PSIA)

.3101

=

VOLUME (CU.FT.)

1910000.0

=

AIR MASS (LBM)

=

710662.5 l

'\\ /

r I

B-8

a

SUMMARY

OF MEASURED DATA AT 1415 1216 TEMP 1 = 532.3800

(

72.710 )

TEMP 2 = 531.5500

(

71.880 )

TEMP 3 = 528.8400

(

69.170 )

TEMP 4 = 532.8000

(

73.130 )

TEMP 5 = 533.0700

(

73.400 )

TEMP 6 = 533.9000

(

74.230 )

TEMP 7 = 535.8100

(

76.140 )

TEMP 8 = 532.5300

(

72.860 )

TEMP 9 = 532.5800

(

72.910 )

TEMP 10 = 532.3500

(

72.680 )

TEMP 11 = 533.2800

(

73.610 )

TEMP 12 = 532.4400

(

72.770 )

1 TEMP 13 = 532.5100

(

72.840 )

TEMP 14 = 532.3800

(

72.710 )

TEMP 15 = 532.4900

(

72.820 )

TEMP 16 = 532.1400

(

72.470 )

TEMP 17 = 532.3300

(

72.660 )

TEMP 18 = 532.3400

(

72.670 )

PRES 1 =

73.7013

( 74169.0 )

PRES 2=

73.6869

( 72472.0 )

VPRS 1

.2938

(

63.890 )

=

VPRS 2=

.3114

(

65.550 )

VPRS 3=

.3094

(

65.370 )

VPRS 4 =

.3049

(

64.950 )

VPRS 5=

.3133

(

65.730 )

VPRS 6=

.3060

(

65.050 )

SUMMARY

OF CORRECTED DATA TIME = 1415 DATE = 1216 TEMPERATURE (DEGREES R.)

532.3954

=

CORRECTED PRESSURE (PSIA) 73.3921

=

VAPOR PRESSURE (PSIA) =

.3092 VOLUME (CU.FT.)

1910000.0

=

AIR MASS (LBM) =

710685.0

("%

L)

B-9 i

SUMMARY

OF MEASURED DOTA AT 1430 1216 TEMP 1 = 532.4400

(

72.770 )

TEMP 2 = 531.5400

(

71.870 )

TEMP 3 = 528.6800

(

69.010 )

TEMP 4 = 532.7700

(

73.100 )

TEMP 5 = 533.0900

(

73.420 )

TEMP 6 = 533.8000

(

74.130 )

TEMP 7 = 535.8000

(

76.130 )

TEMP O = 532.6300

(

72.960 )

TEMP 9 = 532.5700

(

72.900 )

TEMP 10 = 532.3100

(

72.640 )

TEMP 11 = 533.2600

(

73.590 )

TEMP 12 = 532.3900

(

72.720 )

1 TEMP 13 = 532.4700

(

72.800 )

TEMP 14 = 532.3600

(

72.690 )

TEMP 15 = 532.4500

(

72.780 )

TEMP 16 = 532.1000

(

72.430 )

TEMP 17 = 532.3300

(

72.660 )

TEMP 18 = 532.3200

(

72.650 )

PRES 1 =

73.6964

( 74164.0 )

PRES 2=

73.6819

( 72467.0 )

VPRS 1 =

.2894

(

63.460 )

VPRS 2=

.3112

(

65.540 )

VPRS 3=

.3084

(

65.280 )

VPRS 4=

.3051

(

64.970 )

VPRS 5=

.3148

(

65.870 )

VPRS 6=

.3030

(

64.770 )

SUMMARY

OF CORRECTED DATA TIME = 1430 DATE = 1216 TEMPERATURE (DEGREES R.) =

532.3730 CORRECTED PRESSURE (PSIA) 73.3876

=

VAPOR PRESSURE (PSIA)

.3088

=

VOLUME (CU.FT.)

1910000.0

=

AIR MASS (LBM) =

710670.9 (V

O B-10

1

SUMMARY

OF MEASURED DATA AT 1445 1216 TEMP 1 = 532.6300

(

72.960 )

TEMP 2 = 531.5500

(

71.880 )

TEMP 3 = 529.0200

(

69.350 )

TEMP 4 = 532.7600

(

73.090 )

TEMP 5 = 533.1200

(

73.450 )

TEMP 6 = 533.8300

(

74.160 )

TEMP 7 = 535.7900

(

76.120 )

TEMP 8 = 532.5900

(

72.920 )

TEMP 9 = 532.5300

(

72.860 )

TEMP 10 = 532.2800

(

72.610 )

TEMP 11 = 533.2300

(

73.560 )

TEMP 12 = 532.3800

(

72.710 )

1 TEMP 13 = 532.4500

(

72.780 )

TEMP 14 = 532.3500

(

72.680 )

TEMP 15 = 532.4200

(

72.750 )

TEMP 16 = 532.0700

(

72.400 )

TEMP 17 = 532.2600

(

72.590 )

TEMP 18 = 532.2600

(

72.590 )

PRES 1 =

73.6924

( 74160.0 )

PRES 2=

73.6778

( 72463.0 )

VPRS 1

.2894

(

63.460 )

=

VPRS 2=

.3105

(

65.470')

VPRS 3=

.3140

(

65.790 )

VPRS 4 =

.3047

(

64.930 )

VPRS 5=

.3109

(

65.510 )

VPRS 6=

.3043

(

64.890 )

SUMMARY

OF CORRECTED DATA TIME = 1445 DATE = 1216 TEMPERATURE (DEGREES R.)

532.3718

=

CORRECTED PRESSURE (PSIA) 73.3834

=

VAPOR PRESSURE (PSIA)

.3090

=

VOLUME (CU.FT.)

1910000.0

=

AIR MASS (LBM) =

710631.9 l' ^h

'O B-11

6'

SUMMARY

OF MEASURED DATA AT 1500 1216 TEMP 1 = 532.5800

(

72.910 )

TEMP 2 = 531.5400

(

71.870 )

TEMP 3 = 528.9700

(

69.300 )

TEMP 4 = 532.7300

(

73.060 )

TEMP 5 = 533.0000

(

73.330 )

TEMP 6 = 533.8600

(

74.190 )

TEMP 7 = 535.8000

(

76.130 )

TEMP 8 = 532.6100

(

72.940 )

TEMP 9 = 532.5000

(

72.830 )

TEMP 10 = 532.2500

(

72.580 )

TEMP 11 = 533.2200

(

73.550 )

1 TEMP 12 = 532.3400

(

72.670 )

TEMP 13 = 532.4200

(

72.750 )

TEMP 14 = 532.3100

(

72.640 )

TEMP 15 = 532.4200

(

72.750 )

TEMP 16 = 532.0600

(

72.390 )

TEMP 17 = 532.2100

(

72.540 )

TEMP 18 = 532.2700

(

72.600 )

73.6884

( 74156.0 )

PRES 1

=

PRES 2=

73.6737

( 72459.0 )

.3030

(

64.770 )

VPRS 1 =

6 VPRS 2=

.3096

(

65.390 )

VPRS 3=

.3102

(

65.440 )

.3012

(

64.600 )

VPRS 4 =

VPRS 5=

.3142

(

65.810 )

VPRS 6=

.3046

(

64.920 )

SUMMARY

OP CORRECTED DATA TIME = 1500 DATE = 1216 TEMPERATURE (DEGREES R. ) =

532.343d CORRECTED PRESSURE (PSIA)

=

73.3803

.3081 VAPOR PRESSURE (PSIA)

=

VOLUME (CU.FT.)

1910000.0

=

AIR MASS-(LBM) 710640.4

=

r}

v B-12 J

SUMMARY

OF MEASURED DATA AT 1515 1216

\\.)

TEMP 1 = 532.4600

(

72.790 )

TEMP 2 = 531.5600

(

71.890 )

TEMP 3 = 529.1600

(

69.490 )

TEMP 4 = 532.6700

(

73.000')

TEMP 5 = 533.0500

(

73.380 )

TEMP 6 = 533.7300

(

74.060 )

TEMP 7 = 535.7800

(

76.110 )

TEMP 8 = 532.6000

(

72.930 )

TEMP 9 = 532.4800

(

72.810 )

TEMP 10 = 532.2100

(

72.540 )

TEMP 11 = 533.2000

(

73.530 )

1 TEMP 12 = 532.3300

(

72.660 )

TEMP 13 = 532.4100

(

72.740 )

TEMP 14 = 532.2800

(

72.610 )

TEMP 15 = 532.4000

(

72.730 )

TEMP 16 = 532.0600

(

72.390 )

TEMP 17 = 532.2000

(

72.530 )

TEMP 18 = 532.2200

(

72.550 )

PRES 1 =

73.6855

( 74153.0 )

PRES 2=

73.6717

( 72457.0 )

VPRS 1 =

.2987

(

64.360 )

['

VPRS 2=

.3107

(

65.490 )

\\

VPRS 3=

.3074

(

65.180 )

VPRS 4=

.3045

(

64.910 )

VPRS 5=

.3124

(

65.650 )

VPRS 6=

.3065

(

65.100 )

SUMMARY

OF CORRECTED DATA TIME = 1515 DATE = 1216 TEMPERATURE (DEGREES R.)

532.3274

=

CORRECTED PRESSURE (PSIA) 73.3769

=

VAPOR PRESSURE (PSIA)

.3085

=

VOLUME (CU.FT.)

1910000.0

=

AIR MASS (LBM) =

710628.6 O

B-13

SUMMARY

OF MEASURED DATA AT'1530 1216 TEMP 1 = 532.3600

(

72.690 )

TEMP 2 = 531.5400

(

71.870 )

TEMP 3 = 529.1300

(

69.460 )

TEMP 4 = 532.6700

(

73.000 )

TEMP

$ = 532.9800

(

73.310 )

TEMP 6 = 533.7900

(

74.120 )

TEMP 7 = 535.7300

(

76.060 )

TEMP 8 = 532.5800

(

72.910 )

TEMP 9 = 532.4800

(

72.810 )

TEMP 10 = 532.2000

(

72.530 )

TEMP 11 = 533.2000

(

73.530 )

TEMP 12 = 532.2800

(

72.610 )

1 TEMP 13 = 532.3800

(

72.710 )

TEMP 14 = 532.2900

(

72.620 )

TEMP 15 = 532.3900

(

72.720 )

TEMP 16 = 532.0400

(

72.370 )

TEMP 17 = 532.2300

(

72.560 )

TEMP 16 = 522.2400

(

72.570 )

PRES 3

73.6835

( 74151.0 )

=

PRES E=

73.6696

( 72455.0 )

VPRS 1

.3081

(

65.250 )

=

VPRS 2=

.3105

(

65.470 )

VPRS 3=

.3107

(

65.490 )

VPRS 4=

.3060

(

65.050 )

VPRS 5=

.3114

(

65.550 )

VPRS 6=

.3028

(

64.750 )

SUMMARY

OF CORRECTED DATA TIME = 1530 DATE = 1216 TEMPERATURE (DEGREES R.)

532.3110

=

CORRECTED PRESSURE (PSIA) 73.3750

=

VAPOR PRESSURE (PSIA)

.3085

=

VOLUME (CU.FT.)

1910000.0

=

AIR MASS (LBM) 710631.8

=

f}

B-14

)

SUMMARY

OF MEASURED DATA AT 1545 1216 TEMP 1 = 532.6000

(

72.930 )

TEMP 2 = 531.5700

(

71.900 )

TEMP 3 = 529.1000

(

69.430 )

TEMP 4 = 532.6600

(

72.990 )

TEMP 5 = 533.0300

(

73.360 )

TEMP 6 = 533.7800

(

74.110 )

TEMP 7 = 535.7500

(

76.080 )

TEMP 8 = 532.5900

(

72.920 )

TEMP 9 = 532.4600

(

72.790 )

TEMP 10 = 532.2000

(

72.530 )

TEMP 11 = 533.1700

(

73.500 )

TEMP 12 = 532.2900

(

72.620 )

1 TEMP 13 = 532.3800

(

72.710 )

TEMP 14 = 532.2400

(

72.570 )

TEMP 15 = 532.3800

(

72.710 )

TEMP 16 = 531.9800

(

72.310 )

TEMP 17 = 532.2000

(

72.530 )

TEMP 18 = 532.2400

(

72.570 )

PRES 1

73.6815

( 74149.0 )

=

PRES 2=

73.6666

( 72452.0 )

VPRS 1 =

.3032

(

64.790 )

VPRS 2=

.3098

(

65.410 )

VPRS 3=

.3107

(

65.490 )

VPRS 4 =

.3045

(

64.910 )

VPRS 5=

.3123

(

65.640 )

VPRS 6=

.3031

(

64.780 )

SUMMARY

OF CORRECTED DATA TIME = 1545 DATE = 1216 TEMPERATURE (DEGREES R.)

532.3147

=

CORRECTED PRESSURE (PSIA) 73.3732

=

VAPOR PRESSURE (PSIA)

.3083

=

VOLUME (CU.FT.)

= 1910000.0 AIR MASS (LBM) 710609.8

=

v B-15

SUMMARY

OF MEASURED DATA AT 1600 1216 TEMP 1 = 532.5600

(

72.890 )

TEMP 2 = 531.5700

(

71.900 )

TEMP 3 = 529.0500

(

69.380 )

TEMP 4 = 532.6600

(

72.990 )

TEMP 5 = 533.0400

(

73.370 )

TEMP 6 = 533.7700

(

74.100 )

TEMP 7 = 535.7500

(

76.080 )

TEMP 8 = 532.5900

(

72.920 )

TEMP 3 = 532.4500

(

72.760 )

TEMP 10 = 532.2000

(

72.530 )

TEMP 11 = 533.1500

(

73.480 )

TEMP 12 = 532.2600

(

72.590 )

1 TEMP 13 = 532.3600

(

72.690 )

TEMP 14 = 532.2100

(

72.540 )

TEMP 15 = 532.3800

(

72.710 )

TEMP 16 = 532.0000

(

72.330 )

TEMP 17 = 532.1900

(

72.520 )

TEMP 18 = 532.1600

(

72.490 )

PRES 1

73.6795

( 74147.0 )

=

PRES 2=

73.6656

( 72451.0 )

VPRS 1 =

.3041

(

64.870 )

VPRS 2=

.3105

(

65.470 )

VPRS 3=

.3060

(

65.050 )

VPRS 4 =

.3044

(

64.900 )

VPRS 5=

.3154

(

65.920 )

VPRS 6=

.3013

(

64.610 )

SUMMARY

OF CORRECTED DATA TIME = 1600 DATE = 1816 TEMPERATURE (DEGREES R.)

532.2975

=

CORRECTED PRESSURE (PSIA) 73.3717

=

VAPOR PRESSURE (PSIA) =

.3078, VOLUME (CU.FT.)

1910000.0

=

AIR MASS (LBM) 710617.9

=

,%N)

B-18

SUMMARY

OF MEASURED DATA AT 1615 1216 TEMP 1 = 532.4600

(

72.790 )

TEMP 2 = 531.5900

(

71.920 )

TEMP 3 = 529.2200

(

69.550 )

TEMP 4 = 532.6200

(

72.950 )

TEMP 5 = 533.0600

(

73.390 )

TEMP 6 = 533.7900

(

74.120 )

TEMP 7 = 535.7500

(

76.080 )

TEMP 8 = 532.5600

(

72.890 )

TEMP 9 = 532.4500

(

72.780 )

TEMP 10 = 532.2100

(

72.540 )

TEMP 11 = 533.1900

(

73.520 )

1 TEMP 12 = 532.2800

(

72.610 )

TEMP 13 = 532.3600

(

72.690 )

TEMP 14 = 532.2200

(

72.550 )

TEMP 15 = 532.3800

(

72.710 )

TEMP 16 = 532.0000

(

72.350 )

TEMP 17 = 532.1700

(

72.500 )

TEMP 18 = 532.2100

(

72.540 )

73.6785

( 74146.0 )

PRES 1 =

PRES 2=

73.6646

( 72450.0 )

.3005

(

64.530 )

6 VPRS 1

=

VPRS 2=

.3098

(

65.410 )

VPRS 3=

.3103

(

65.450 )

VPRS 4=

.3066

(

65.110 )

VPRS 5=

.3147

(

65.860 )

VPRS 6=

.3005

(

64.530 )

SUMMARY

OF CORRECTED DATA TIME = 1615 DATE = 1216 532.3048 TEMPERATURE (DEGREES R.)

=

73.3700 CORRECTED PRESSURE (PSIA)

=

.3085 VAPOR PRESSURE (PSIA) =

VOLUME (CU.FT.) = 1910000.0 710591.5 AIR MASS (LBM) =

)

v B-17

SUMMARY

OF MEASURED DATA AT 1715 1216 i

m,-

TEMP 1 = 532.4600

(

72.790 )

TEMP 2 = 531.6300

(

71.960 )

TEMP 3 = 529.1400

(

69.470 )

TEMP 4 = 532.6700

(

73.000 )

TEMP 5 = 533.0000

(

73.330 )

TEMP 6 = 533.7800

(

74.110 )

TEMP 7 = 535.7400

(

76.070 )

TEMP 8 = 532.5700

(

72.900 )

TEMP 9 = 532.4600

(

72.790 )

TEMP 10 = 532.1800

(

72.510 )

TEMP 11 = 533.1500

(

73.480 )

TEMP 12 = 532.2700

(

72.600 >

1 TEMP 13 = 532.3100

(

72.640 )

TEMP 14 = 532.1800

(

72.510 )

TEMP 15 = 532.3800

(

72.710 )

TEMP 16 = 531.9700

(

72.300 )

TEMP 17 = 532.1600

(

72.490 )

TEMP 18 = 532.2000

(

72.530 )

PRES 1 =

73.6755

( 74143.0 )

PRES 2=

73.6615

( 72447.0 )

VPRS 1 =

.3154

(

65.920 )

6 VPRS 2=

.3084

(

65.280 )

VPRS 3=

.3105

(

65.470 )

VPRS 4 =

.3029

(

64.760 )

VPRS 5=

.3129

(

65.690 )

VPRS 6=

.3018

(

64.660 )

SUMMARY

OF CORRECTED DATA TIME = 1715 DATE = 1216 TEMPERATURE (DEGREES R.)

532.2873

=

CORRECTED PRESSURE (PSIA) =

73.3681 VAPOR PRESSURE (PSIA)

.3074

=

VOLUME (CU.FT.)

1910000.0

=

AIR MASS (LBM) =

710596.8 U

C-6

SUMMARY

OF MEASURED DATA AT 1730 1216 j

TEMP 1 = 532.5600

(

72.890 )

TEMP 2 = 531.6400

(

71.970 )

TEMP 3 = 529.2500

(

69.580 )

TEMP 4 = 532.6400

(

72.970 )

TEMP 5 = 533.0600

(

73.390 )

TEMP 6 = 533.7300

(

74.060 )

TEMP 7 = 535.7300

(

76.060 )

TEMP 8 = 532.5100

(

72.840 )

TEMP 9 = 532.4400

(

72.770 )

TEMP 10 = 532.2100

(

72.540 )

TEMP 11 = 533.1900

(

73.520 )

TEMP 12 = 532.2700

(

72.600 )

1 TEMP 13 = 532.3200

(

72.650 )

TEMP 14 = 532.1900

(

72.520 )

TEMP 15 = 532.3800

(

72.710 )

TEMP 16 = 532.0000

(

72.330 )

TEMP 17 = 532.1300

(

72.460 )

TEMP 18 = 532.1900

(

72.520 )

PRES 1 =

73.6755

( 74143.0 )

PRES 2=

73.6615

( 72447.0 )

.3021

(

64.680 )

VPRS 1

=

VPRS 2=

.3097

(

65.400 )

VPRS 3=

.3099

(

65.420 )

.3014

(

64.620 )

VPRS 4 =

VPRS 5=

.3109

(

65.510 )

VPRS 6=

.3011

(

64.590 )

SUMMARY

OF CORRECTED DATA TIME = 1730 DATE = 1216 532.2993 TEMPERATURE (DEGREES R.)

=

73.3686 CORRECTED PRESSURE (PSIA)

=

.3069 VAPOR PRESSURE (PSIA)

=

VOLUME (CU.FT.) = 1910000.0 710585.6 AIR MASS (LBM)

=

g L,

c-a

)

F

SUMMARY

OF MEASURED DATA AT 1745 1216 TEMP 1 = 532.6500

(

72.980 )

TEMP 2 = 531.6400

(

71.970 )

TEMP 3 = 529.2500

(

69.580 )

TEMP 4 = 532.6200

(

72.950 )

TEMP 5 = 533.1100

(

73.440 )

TEMP 6 = 533.7700

(

74.100 )

TEMP 7 = 535.7600

(

76.090 )

TEMP 8 = 532.5100

(

72.840 )

TEMP 9 = 532.4300

(

72.760 )

TEMP 10 = 532.2200

(

72.550 )

TEMP 11 = 533.1800

(

73.510 )

TEMP 12 = 532.2700

(

72.600 )

1 TEMP 13 = 532.3300

(

72.660 )

TEMP 14 = 532.1600

(

72.490 )

TEMP 15 = 532.3800

(

72.710 )

TEMP 16 = 532.0000

(

72.330 )

TEMP 17 = 532.1300

(

72.460 )

TEMP 18 = 532.1600

(

72.490 )

PRES 1 =

73.6755

( 74143.0 )

PRES 2=

73.6615

( 72447.0 )

VPRS 1 =

.3109

(

65.510 )

VPRS 2=

.3087

(

65.300 )

VPRS 3=

.3095

(

65.380 )

VPRS 4=

.3013

(

64.610 )

VPRS 5=

.3110

(

65.520 )

VPRS 6=

.3032

(

64.790 )

SUMMARY

OF CORRECTED DATA TIME = 1745 DATE = 1216 TEMPERATURE (DEGREES R.) =

532.3038 CORRECTED PRESSURE (PSIA) 73.3686

=

VAPOR PRESSURE (PSIA) =

.3069 VOLUME (CU.FT.)

1910000.0

=

AIR MASS (LBM) =

710579.6

(~h LJ C-7

i

~

(]

SUMMARY

OF MEASURED DATA AT 1800 1216 l

s TEMP 1 = 532.6300

(

72.960 )

TEMP 2 = 531.6500

(

71.980 )

TEMP 3 = 529.1300

(

69.460 )

TEMP 4 = 532.6500

(

72.980 )

TEMP 5 = 533.0500

(

73.380 )

TEMP 6 = 533.8000

(

74.130 )

TEMP 7 = 535.7300

(

76.060 )

TEMP 8 = 532.5400

(

72.870 )

TEMP 9 = 532.4500

(

72.780 )

TEMP 10 = 532.2200

(

72.550 )

TEMP 11 = 533.1800

(

73.510 )

TEMP 12 = 532.2900

(

72.620 )

1 TEMP 13 = 532.3200

(

72.650 )

TEMP 14 = 532.1800

(

72.510 )

TEMP 15 = 532.3800

(

72.710 )

TEMP 16 = 531.9300

(

72.260 )

TEMP 17 = 532.1400

(

72.470 )

TEMP 18 = 532.1900

(

72.520 )

PRES 1 =

73.6755

( 74143.0 )

PRES 2=

73.6615

( 72447.0 )

.3018

(

64.660 )

VPRS 1

=

6 VPRS 2=

.3090

(

65.330 )

VPRS 3=

.3094

(

65.370 )

VPRS 4=

.3017

(

64.650 )

VPRS 5=

.3084

(

65.280 )

VPRS 6=

.3067

(

65.120 )

SUMMARY

OF CORRECTED DATA TIME = 1800 DATE = 1216 TEMPERATURE (DEGREES R.) =

532.2983 CORRECTED PRESSURE (PSIA) 73.3683

=

VAPOR PRESSURE (PSIA)

.3073

=

VOLUME (CU.FT.)

1910000.0

=

710583.8 AIR MASS (LBM)

=

t' 3

\\vl C-8 1

9 e

SUMMARY

OF MEASURED DATA AT 1815 1216 TEMP 1 = 532.6200

(

72.950 )

TEMP 2 = 531.6900

(

72.020 )

TEMP 3 = 529.0800

(

69.410 )

TEMP 4 = 532.6400

(

72.970 )

TEMP 5 = 533.0100

(

73.340 )

TEMP 6 = 533.7100

(

74.040 )

TEMP 7 = 535.7600

(

76.090 )

TEMP 8 = 532.5800

(

72.910 )

TEMP 9 = 532.4500

(

72.780 )

TEMP 10 = 532.2200

(

72.550 )

TEMP 11 = 533.2200

(

73.550 )

TEMP 12 = 532.3000

(

72.630 )

1 TEMP 13 = 532.3500

(

72.680 )

TEMP 14 = 532.2100

(

72.540 )

TEMP 15 = 532.4000

(

72.730 )

TEMP 16 = 531.9400

(

72.270 )

TEMP 17 = 532.1900

(

72.520 )

TEMP 18 = 532.1800

(

}2.510 )

PRES 1 =

73.6755

( 74143.0 )

PRES 2=

73.6615

( 72447.0 )

VPRS 1

.3213

(

66.460 )

=

VPRS 2=

.3084

(

65.280 )

VPRS 3=

.3105

(

65.470 )

VPRS 4 =

.3027

(

64.740 )

VPRS 5=

.3102

(

65.440 )

VPRS 6=

.3026

(

64.730 )

SUMMARY

OF CORRECTED DATA TIME = 1815 DATE = 1216 532.3082 TEMPERATURE (DEGREES R.)

=

73.3685 CORRECTED PRESSURE (PSIA)

=

.3070 VAPOR PRESSURE (PSIA)

=

VOLUME (CU.FT.) = 1910000.0 710572.8 AIR MASS (LBM)

=

(

h e-I C-9

SUMMARY

OF MEASURED DATA AT 1830 1216 6

TEMP 1 = 532.7400

(

73.070 )

TEMP 2 = 531.6900

(

72.020 )

TEMP 3 = 529.2100

(

69.540 )

TEMP 4 = 532.6300

(

72.960 )

TEMP 5 = 532.9600

(

73.290 )

TEMP 6 = 533.8600

(

74.190 )

TEMP 7 = 535.7800

(

76.110 )

TEMP 8 = 532.5400

(

72.870 )

TEMP 9 = 532.4400

(

72.770 )

TEMP 10 = 532.1800

(

72.510 )

TEMP 11 = 533.2200

(

73.550 )

TEMP 12 = 532.3400

(

72.670 )

1 TEMP 13 = 532.3400

(

72.670 )

TEMP 14 = 532.1800

(

72.510 )

TEMP 15 = 532.3700

(

72.700 )

TEMP 16 = 532.0100

(

72.340 )

TEMP 17 = 532.1400

(

72.470 )

TEMP 18 = 532.2000

(

72.530 )

73.6765

( 74144.0 )

PRES 1

=

PRES 2=

73.6625

( 72448.0 )

.3063

(

65.080 )

VPRS 1 =

6 VPRS 2=

.3072

(

65.160 )

VPRS 3=

.3114

(

65.550 )

VPRS 4=

.3051

(

64.970 )

VPRS 5=

.3118

(

65.590 )

VPRS 6=

.2986

(

64.350 )

SUMMARY

OF CORRECTED DATA TIME = 1830 DATE = 1216 TEMPERATURE (DEGREES R.) =

532.3173 73.3697 CORRECTED PRESSURE (PSIA)

=

=

.3068 VAPOR PRESSURE (PSIA)

VOLUME (CU.FT.) = 1910000.0 710572.0 AIR MASS (LBM)

=

0 C-10

SUMMARY

OF MEASURED DATA AT 1845 1216 TEMP 1 = 532.7600

(

73.090 )

TEMP 2 = 531.7300

(

72.060 )

TEMP 3 = 529.2700

(

69.600 )

TEMP 4 = 532.6700

(

73.000 )

TEMP 5 = 532.9600

(

73.290 )

TEMP 6 = 533.9000

(

74.230 )

TEMP 7 = 535.7900

(

76.120 )

TEMP 8 = 532.5000

(

72.850 )

TEMP 9 = 532.4600

(

72.790 )

TEMP 10 = 532.2100

(

72.540 )

TEMP 11 = 533.2300

(

73.560 )

TEMP 12 = 532.3000

(

72.630 )

1 TEMP 13 = 532.3400

(

72.670 )

TEMP 14 = 532.1800

(

72.510 )

TEMP 15 = 532.4100

(

72.740 )

TEMP 16 = 531.9900

(

72.320 )

TEMP 17 = 532.1500

(

72.480 )

TEMP 18 = 532.2100

(

72.540 )

PRES 1 =

73.6775

( 74145.0 )

PRES 2=

73.6646

( 72450.0 )

VPRS 1 =

.3165

(

66.020 )

VPRS 2=

.3083

(

65.270 )

VPRS 3=

.3051

(

64.970 )

VPRS 4=

.3043

(

64.890 )

VPRS 5=

.3130

(

65.700 )

VPRS 6=

.3032

(

64.790 )

SUMMARY

OF CORRECTED DATA TIME = 1845 DATE = 1216 532.3256 TEMPERATURE (DEGREES R.)

=

CORRECTED PRESSURE (PSIA) 73.3706

=

VAPOR PRESSURE (PSIA) =

.3069 VOLUME (CU.FT.)

1910000.0

=

AIR MASS (LBM) 710563.5

=

P v

C-11

.s

SUMMARY

OF MEASURED DATA AT 1900 1216 TEMP 1 = 532.6800

(

73.010 )

TEMP 2 = 531.7100

(

72.040 )

TEMP 3 = 529.2100

(

69.540 )

TEMP 4 = 532.6600

(

72.990 )

TEMP 5 = 532.9400

(

73.270 )

TEMP 6 = 533.9600

(

74.290 )

TEMP 7 = 535.7800

(

76.110 )

TEMP 8 = 532.4300

(

72.760 )

TEMP 9 = 532.4900

(

72.820 )

TEMP 10 = 532.2400

(

72.570 )

TEMP 11 = 533.2300

(

73.560 )

TEMP 12 = 532.3100

(

72.640 )

1 TEMP 13 = 532.3700

(

72.700 )

TEMP 14 = 532.2000

(

72.530 )

TEMP 15 = 532.3900

(

72.720 )

TEMP 16 = 532.0700

(

72.400 )

TEMP 17 = 532.1700

(

72.500 )

TEMP 18 = 532.2100

(

72.540 )

PRES 1 =

73.6785

( 74146.0 >-

PRES 2=

73.6656

( 72451.0 )

VPRS 1

.2957

(

64.070 )

=

VPRS 2=

.3080

(

65.240 )

VPRS 3=

.3080

(

65.240 )

VPRS 4=

.3011

(

64.590 )

VPRS 5=

.3096

(

65.390 )

VPRS 6=

.3047

(

64.930 )

SUMMARY

OF CORRECTED DATA TIME = 1900 DATE = 1216 TEMPERATURE (DEGREES R.)

532.3307

=

CORRECTED PRESSURE (PSIA) =

73.3730 VAPOR PRESSURE (PSIA)

.3065

=

VOLUME (CU.FT.) = 1910000.0 AIR MA6S (LBM) =

710577.0

(.,

s

)

\\_/

C-12

SUMMARY

OF MEASURED DATA AT 1915 1216 TEMP 1 = 532.5700

(

72.900 )

TEMP 2 = 531.7200

(

72.050 )

TEMP 3 = 529.1000

(

69.430 )

TEMP 4 = 532.6900

(

73.020 )

TEMP 5 = 532.9800

(

73.310 )

TEMP 6 = 533.9200

(

74.250 )

TEMP 7 = 535.7900

(

76.120 )

TEMP 8 = 532.3900

(

72.720 )

TEMP 9 = 532.5200

(

72.850 )

TEMP 10 = 532.2400

(

72.570 )

TEMP 11 = 533.2300

(

73.560 )

TEMP 12 = 532.3100

(

72.640 )

1 TEMP 13 = 532.3700

(

72.700 )

TEMP 14 = 532.2200

(

72.550 )

TEMP 15 = 532.4200

(

72.750 )

TEMP 16 = 532.0200

(

72.350 )

TEMP 17 = 532.1700

(

72.500 )

TEMP 18 = 532.2200

(

72.550 )

PRES 1

73.6795

( 74147.0 )

=

PRES 2=

73.6666

( 724b2.0 )

VPRS 1 =

.3036

(

64.830 )

VPRS 2=

.3084

(

65.280 )

VPRS 3=

.3106

(

65.480 )

VPRS 4=

.3001

(

64.490 )

VPRS 5=

.3117

(

65.580 )

VPRS 6=

.3026

(

64.730 )

SUMMARY

OF CORRECTED DATA TIME = 1915 DATE = 1216 TEMPERATURE (DEGREES R.)

532.3257

=

CORRECTED PRESSURE (PSIA) 73.3727

=

.3069 VAPOR PRESSURE (PSI 4)

=

1910000.0 VOLUME (CU.FT.) =

AIR MASS (LBM) =

710569.5 s

)

x_/

C-13 i

.i

SUMMARY

OF MEASURED DATA AT 1930 1216 TEMP 1 = 532.4900

(

72.820 )

TEMP 2 = 531.7800

(

72.110 )

TEMP 3 = 529.2100

(

69.540 )

TEMP 4 = 532.6800

(

73.010 )

TEMP 5 = 532.9400

(

73.270 )

TEMP 6 = 533.9500

(

74.280 )

TEMP 7 = 535.8200

(

76.150 )

TEMP 8 = 532.4100

(

72.740 )

TEMP 9 = 532.4800

(

72.810 )

TEMP 10 = 532.2600

(

72.590 )

TEMP 11 = 533.2500

(

73.580 )

TEMP 12 = 532.3300

(

72.660 )

1 TEMP 13 = 532.3800

(

72.710 )

TEMP 14 = 532.2200

(

72.550 )

TEMP 15 = 532.4400

(

72.770 )

TEMP 16 = 532.0100

(

72.340 )

TEMP 17 = 532.1700

(

72.500 )

TEMP 18 = 532.2600

(

72.590 )

PRES 1 =

73.6805

( 74148.0 )

PRES 2=

73.6676

( 72453.0 )

VPRS 1 =

.3066

(

65.110 )

VPRS 2=

.3077

(

65.210 )

VPRS 3=

.3083

(

65.270 )

VPRS 4=

.3031

(

64.780 )

VPRS 5=

.3137

(

65.770 )

VPRS 6=

.3012

(

64.600 )

SUMMARY

OF CORRECTED DATA TIME = 1930 DATE = 1216 TEMPERATURE (DEGREES R.)

532.3340

=

CORRECTED PRESSURE (PSIA) 73.3736

=

VAPOR PRESSURE (PSIA) =

.3069 1910000.0 VOLUME (CU.FT.)

=

AIR MASS (LBM) =

710587.6 v

C-14

,e

SUMMARY

OF MEASURED DATA AT 1945 1216 TEMP 1 = 532.6500

(

72.980 )

TEMP 2 = 531.7900

(

72.120 )

TEMP 3 = 529.1500

(

69.480 )

TEMP 4 = 532.6800

(

73.010 )

TEMP 5 = 532.9700

(

73.300 )

TEMP 6 = 534.0000

(

74.330 )

TEMP 7 = 535.8100

(

76.140 )

TEMP 8 = 532.4200

(

72.750 )

TEMP 9 = 532.5400

(

72.870 )

TEMP 10 = 532.2500

(

72.580 )

TEMP 11 = 533.2700

(

73.600 )

TEMP 12 = 532.3600

(

72.690 )

1 TEMP 13 = 532.3800

(

72.710 )

TEMP 14 = 532.2500

(

72.580 )

TEMP 15 = 532.4400

(

72.770 )

TEMP 16 = 532.0400

(

72.370 )

TEMP 17 = 532.2000

(

72.530 )

TEMP 18 = 532.2500

(

72.580 )

PRES 1 =

73.6815

( 74149.0 )

PRES 2=

73.6686

( 72454.0 )

VPRS 1 =

.3011

(

64.590 )

6 VPRS 2=

.3075

(

65.190 )

VPRS 3=

.3099

(

65.420 )

VPRS 4=

.3030

(

64.770 )

VPRS 5=

.3106

(

65.480 )

VPRS 6=

.3061

(

65.060 )

SUMMARY

OF CORRECTED DATA TIME = 1945 DATE = 1216 TEMPERATURE (DEGREES R.) =

532.3566 CORRECTED PRESSURE (PSIA) =

73.3741 VAPOR PRESRURE (PSIA) =

.3074 VOLUME (CU.FT.) = 1910000.0 AIR MASS (LDM) 710562.1

=

,~

\\ /

C-15

r e

SUMMARY

OF MEASURED DATA AT 2000 1216 TEMP 1 = 532.6800

(

73.010 )

TEMP 2 = 531.8000

(

72.130 )

TEMP 3 = 529.1800

(

69.510 )

TEMP 4 = 532.7200

(

73.050 )

TEMP 5 = 532.9500

(

73.280 )

TEMP G = 534.0800

(

74.410 )

TEMP 7 = 535.8300

(

76.160 )

TEMP 8 = 532.4300

(

72.760 )

TEMP 3 = 532.5100

(

/2.840 )

TEMP 10 = 532.2700

(

72.600 )

TEMP 11 = 533.2700

(

73.600 )

TEMP 12 = 532.3700

(

72.700 )

1 TEMP 13 = 532.4000

(

72.730 )

TEMP 14 = 532.2700

(

72.600 )

TEMP 15 = 532.4300

(

72.760 )

TEMP 16 = 531.9900

(

72.320 )

TEMP 17 = 532.2100

(

72.540 )

TEMP 18 = 532.2800

(

72.610 )

PRES 1 =

73.6825

( 74150.0 )

PRES 2=

73.6696

( 72455.0 )

.3080

(

65.240 )

VPRS 1

=

VPRS 2=

.3082

(

65.260 )

VPRS 3=

.3087

(

65.300 )

VPRS 4=

.3023

(

64.700 )

VPRS 5=

.3104

(

65.460 )

VPRS 6=

.3012

(

64.600 )

SUMMARY

OF CORRECTED DATA TIME = E000 DATE = 1216 TEMPERATURE (DEGREES R.) =

532.3646 CORRECTED PRESSURE (PSIA) =

73.3761 VAPOR PRESSURE (PSIA) =

.3064 1910000.0 VOLUME (CU.FT.) =

AIR FASS (LBM) =

710571.3

[']'

C-16

SUMMARY

OF MEASURED DATA AT 2015 1216 TEMP 1 = 532.7500

(

73.080 )

TEMP 2 = 531.8000

(

72.130 )

TEMP 3 = 529.1400

(

69.470 )

TEMP 4 = 532.7300

(

73.060 )

TEMP 5 = 533.1300

(

73.460 )

TEMP 6 = 534.0000

(

74.330 )

TEMP 7 = 535.8200

(

76.150 )

TEMP 8 = 532.4600

(

72.790 )

TEMP 9 = 532.5300

(

72.860 )

TEMP 10 = 532.2800

(

72.610 )

TEMP 11 = 533.2400

(

73.570 )

TEMP 12 = 532.4400

(

72.770 )

1 TEMP 13 = 532.4000

(

72.730 )

TEMP 14 = 532.2400

(

72.570 )

TEMP 15 = 532.4700

(

72.800 )

TEMP 16 = 532.0400

(

72.370 )

TEMP 17 = 532.2200

(

72.550 )

TEMP 18 = 532.2700

(

72.600 )

PRES 1 =

73.6835

( 74151.0 )

PRES 2=

73.6707

( 724S6.0 )

VPRS 1 =

.3130

(

65.700 )

VPRS 2=

.3073

(

65.170 )

VPRS 3=

.3086

(

65.290 )

VPRS 4 =

.3031

(

64.760 )

VPRS 5=

.3146

(

65.850 )

VPRS 6=

.3031

(

64.780 )

SUMMARY

OF CORRECTED DATA TIME = 2015 DATE = 1216 TEMPERATURE (DEGREES R.)

532.3900

=

CORRECTED PRESSURE (PSIA) =

73.3762 VAPOR PRESSURE (PSIA)

.3073

=

VOLUME (CU.FT.)

1910000.0

=

AIR MASS (LBM) 710537.6

=

f-~

)

i

m. <

C-17

SUMMARY

OF MEASURED DATA AT 2030 1216 TEMP 1 = 532.7400

(

73.070 )

TEMP 2 = 531.8200

(

72.150 )

TEMP 3 = 529.0400

(

69.370 )

TEMP 4 = 532.7300

(

73.060 )

TEMP 5 = 533.1800

(*

73.510 )

TEMP 6 = 534.0500

(

74.380 )

TEMP 7 = 535.8800

(

76.210 )

TEMP 8 = 532.4800

(

72.810 )

TEMP 3 = 532.5400

(

72.870 )

TEMP 10 = 532.3000

(

72.630 )

TEMP 11 = 533.3200

(

73.650 )

TEMP 12 = 532.4400

(

72.770 >

1 TEMP 13 = 532.4300

(

72.760 )

TEMP 14 = 532.2800

(

72.610 )

TEMP 15 = 532.4600

(

72.790 )

TEMP 16 = 532.0900

(

72.420 )

TEMP 17 = 532.2400

(

72.570 )

TEMP 18 = 532.3000

(

72.630 )

73.6865

( 74154.0 )

PRES 1 =

PRES 2=

73.6727

( 72458.0 )

VPRS 1 =

.2978

(

64.270 )

VPRS 2=

.3078

(

65.220 )

VPRS 3=

.3097

(

65.400 )

VPRS 4=

.3014

(

64.620 )

VPRS 5=

.3131

(

65.710 )

VPRS 6=

.3025

(

64.720 )

SUMMARY

OF CORRECTED DATA TIME = 2030 DATE = 1216 532.4111 TEMPERATURL (DEGREES R.)

=

=

73.3795 CORRECTED PRESSURE (PSIA)

VAPOR PRESSURE (PSIA) =

.3070 VOLUME (CU.FT.) = 1910000.0 AIR FA55 (LBM) =

710541.5 (U

~%

C-18

~.

SUMMARY

OF MEASURED DATA AT 2045 1216 I

l TEMP 1 = 532.6500

(

73.180 )

TEMP 2 = 531.8600

(

72.190 )

TEMP 3 = 529.1800

(

69.510 )

TEMP 4 = 532.7400

(

73.070 )

TEMP 5 = 532.9800

(

73.310 )

TEMP 6 = 534.0700

(

74.400 )

TEMP 7 = 535.8300

(

76.220 )

TEMP 8 = 532.5000

(

72.830 )

TEMP 9 = 532.5600

(

72.890 )

TEMP 10 = 532.2900

(

72.620 )

TEMP 11 = 533.3000

(

73.630 )

TEMP 12 = 532.4400

(

72.770 )

1 TEMP 13 = 532.4200

(

72.750 )

TEMP 14 = 532.2700

(

72.600 )

TEMP 15 = 532.5200

(

72.850 )

TEMP 16 = 532.1200

(

72.450 )

TEMP 17 = 532.2200

(

72.550 )

TEMP 18 = 532.3100

(

72.640 )

PRES 1

73.6874

( 74155.0 )

=

PRES 2=

73.6737

( 72459.0 )

VPRS 1 =

.3122

(

65.630 )

6 VPRS 2=

.3081

(

65.250 )

VPRS 3=

.3110

(

65.520 )

VPRS 4 =

.3007

(

64.550 )

VPRS 5=

.3114

(

65.550 )

VPRS 6=

.3047

(

64.930 )

SUMMARY

OF CORRECTED DATA TIME = 2045 DATE = 1216 TEMPERATURE (DEGREES R.)

532.4156

=

CORRECTED PRESSURE (PSIA) =

73.380d VAPOR PRESSURE (PSIA)

.3073

=

VOLUME (CU.FT.)

1910000.0

=

AIR MASS (LBM) =

710542.3

~f

\\._)

C-19

gr

SUMMARY

OF MEASURED DATA AT 2100 1216 e

5, TEMP 1 = 532.8100

(

73.140 )

TEMP 2 = 531.8600

(

72.190 )

TEMP 3 = 529.1400

(

69.470 )

TEMP 4 = 532.7600

(

73.090 )

TEMP

$ = 533.0700

(

73.400 )

TEMP 6 = 534.0600

(

74.390 )

TEMP 7 = 535.9000

(

76.230 )

TEMP 8 = 532.4700

(

72.800 )

TEMP 3 = 532.5800

(

72.910 )

TEMP 10 = 532.3200

(

72.650 )

TEMP 11 = 533.3500

(

73.680 )

TEMP 12 = 532.4700

(

72.800 )

1 TEMP 13 = 532.4300

(

72.760 )

TEMP 14 = 532.2900

(

72.620 )

TEMP 15 = 532.5200

(

72.850 )

TEMP 16 = 532.1100

(

72.440 )

TEMP 17 = 532.2500

(

72.580 )

TEMP 18 = 532.3200

(

72.650 )

PRES 1 =

73.6884

( 74156.0 )

PRES 2=

73.6758

( 72461.0 )

.3088

(

65.310 )

VPRS 1

=

f5 VPRS 2=

.3067

(

65.120 )

VPRS 3=

.3041

(

64.870 )

VPRS 4=

.3006

(

64.540 )

VPRS 5=

.3101

(

65.430 )

VPRS 6=

.3003

(

64.510 )

SUMMARY

OF CORRECTED DATA TIME = 2100 DATE = 1216 TEMPERATURE (DEGREES R.)

532.4290

=

CORRECTED PRESSURE (PSIA) 73.3839

=

VAPOR PRESSURE (PSIA)

.3046

=

1910060.0 VOLUME (CU.FT.)

=

710560.2 AIR MA6S (LBM)

=

~

C-20

SUMMARY

OF MEASURED DATA AT 2115 1216 TEMP 1 = 532.8100

(

73.140 )

TEMP 2 = 531.8600

(

72.190 )

TEMP 3 = 529.3600

(

69.690 )

TEMP 4 = 532.7400

(

73.070 )

TEMP 5 = 533.0300

(

73.420 )

TEMP 6 = 534.0400

(

74.370 )

TEMP 7 = 535.9100

(

76.240 )

TEMP 8 = 532.5100

(

72.840 )

TEMP 9 = 532.5400

(

72.870 )

TEMP 10 = 532.3500

(

72.680 )

TEMP 11 = 533.3400

(

73.670 )

TEMP 12 = 532.4800

(

72.810 )

j 1 TEMP 13 = 532.4400

(

72.770 )

TEMP 14 = 532.3400

(

72.670 )

TEMP 15 = 532.5200

(

72.850 )

TEMP 16 = 532.1400

(

72.470 )

TEMP 17 = 532.2700

(

72.600 )

TEMP 18 = 532.3300

(

72.660 )

PRES 1 =

73.6904

( 74158.0 )

PRES 2=

73.6768

( 72462.0 )

VPRS 1 =

.3050

(

64.960 )

VPRS 2=

.3081

(

65.250 )

VPRS 3=

.3059

(

65.040 )

VPRS 4=

.2997

(

64.460 )

VPRS 5=

.3127

(

65.670 )

VPRS 6=

.2986

(

64.350 )

SUMMARY

OF CORRECTED DATA TIrii = 2115 DATE = 1216 TEMPERATURE (DEGREES R.)

532.4475

=

CORRECTED PRESSURE (PSIA) 73.3851

=

VAPOR PRESSURE (PSIA)

.3053

=

VOLUME (CU.FT.)

1910000.0

=

AIR MASS (LBM) 710547.6

=

'w/

C-21

SUMMARY

OF MEASURED DATA AT 2130 1216 TEMP 1 = 532.8600

(

73.190 )

TEMP 2 = 531.9000

(

72.230 )

TEMP 3 = 529.1900

(

69.520 )

TEMP 4 = 532.7900

(

73.120 )

TEMP 5 = 533.1600

(

73.490 )

TEMP 6 = 534.0500

(

74.380 )

TEMP 7 = 535.9100

(

76.240 )

TEMP 8 = 532.5600

(

72.890 )

TEMP 3 = 532.6100

(

72.940 )

TEMP 10 = 532.3600

(

72.690 )

TEMP 11 = 533.3600

(

73.690 )

TEMP 12 = 532.4900

(

72.820 )

TEMP 13 = 532.4600

(

72.790 )

1 TEMP 14 = 532.3100

(

72.640 )

TEMP 15 = 532.5200

(

72.850 )

TEMP 16 = 532.1200

(

72.450 )

TEMP 17 = 532.2800

(

72.610 )

TEMP 18 = 532.3600

(

72.690 )

73.6914

( 74159.0 )

PRES 1 =

PRES 2=

73.6788

( 72464.0 )

.3195

(

66.290 )

VPRS 1

=

VPRS 2=

.3079

(

65.230 )

VPRS 3=

.3083

(

65.270 )

VPRS 4=

.3025

(

64.720 )

VPRS 5=

.3124

(

65.650 )

VPRS 6=

.3030

(

64.770 )

SUMMARY

OF CORRECTED DATA TIME = 2130 DATE = 1216 532.4599 TEMPERATURE (DEGREES R.)

=

73.3845 CORRECTED PRESSURE (PSIA)

=

.3069 VAPOR PRESSURE (PSIA)

=

VOLUME (CU.FT.) = 1910000.0 AIR MASS (LBM) =

710525.0

[~'N 4

L) i C-22

SUMMARY

OF MEASURED DATA AT 2145 1216 TEMP 1 = 532.9500

(

73.280 )

TEMP 2 = 531.9000

(

72.230 )

TEMP 3 = 529.2500

(

69.580 )

TEMP 4 = 532.8000

(

73.130 )

TEMP 5 = 533.1400

(

73.470 )

TEMP 6 = 534.0300

(

74.360 )

TEMP 7 = 535.9300

(

76.260 )

TEMP 8 = 532.6000

(

72.930 )

TEMP 9 = 532.6100

(

72.940 )

TEMP 10 = 532.3700

(

72.700 )

TEMP 11 = 533.3800

(

73.710 )

TEMP 12 = 532.4800

(

72.810 )

1 TEMP 13 = 532.4800

(

72.810 )

TEMP 14 = 532.3300

(

72.660 )

TEMP 15 = 532.5600

(

72.890 )

TEMP 16 = 532.1600

(

72.490 )

TEMP 17 = 532.2800

(

72.610 )

TEMP 18 = 532.3300

(

72.660 )

73.6924

( 74160.0 )

PRES 1

=

PRES 2=

73.6798

( 72465.0 )

.3175

(

66.110 )

VPRS 1

=

VPRS 2=

.3072

(

65.160 )

VPRS 3=

.3040

(

64.860 )

VPRS 4=

.2996

(

64.450 )

VPRS 5=

.3082

(

65.260 )

VPRS 6=

.2982

(

64.310 )

SUMMARY

OF CORRECTED DATA TIME = 2145 DATE = 1216 532.4737 TEMPERATURE (DEGREES R.)

=

73.3886 CORRECTED PRESSURE (PSIA)

=

.3038 VAPOR PRESSURE (PSIA)

=

1910000.0 VOLUME (CU.FT.)

=

710546.5 AIR MASS (LBM)

=

)

v C-23

SUMMARY

OF MEASURED DATA AT 2200 1216 TEMP 1 = 532.9900

(

73.320 )

TEMP 2 = 531.9400

(

72.270 )

TEMP 3 = 529.4100

(

69.740 )

TEMP 4 = 532.8000

(

73.130 )

TEMP 5 = 533.1000

(

73.430 )

TEMP 6 = 534.0500

(

74.380 )

TEMP 7 = 535.9500

(

76.280 )

TEMP 8 = 532.6100

(

72.940 )

TEMP 9 = 532.5900

(

72.9E0 )

TEMP 10 = 532.3600

(

72.690 )

TEMP 11 = 533.4400

(

73.770 )

TEMP 12 = 532.5400

(

72.870 )

1 TEMP 13 = 532.4800

(

72.810 )

TEMP 14 = 532.3500

(

72.680 )

TEMP 15 = 532.5700

(

72.900 )

TEMP 16 = 532.1500

(

72.480 )

TEMP 17 = 532.3000

(

72.650 )

TEMP 18 = 532.4000

(

72.730 )

73.6954

( 74163.0 )

PRES 1 =

PRES 2=

73.6819

( 72467.0 )

.3307

(

67.290 )

VPRS 1 =

6 VPRS 2=

.3075

(

65.190 )

VPRS 3=

.3086

(

65.290 )

VPRS 4=

.2981

(

64.300 )

VPRS 5=

.3120

(

65.610 )

VPRS 6=

.3030

(

64.770 )

SUMMARY

OF CORRECTED DATA TIME = 2200 DATE = 1216 532.4963 TEMPERATURE (DEGREES R.)

=

73.3894 CORRECTED PRESSURE (PSIA)

=

.3060 VAPOR PRESSURE (PSIA)

=

1910000.0 VOLUME (CU.FT.)

=

710523.2 AIR MA6s (LBM)

=

['S v

C-24

SUMMARY

OF MEASURED DATA AT 2215 1216 TEMP 1 = 532.7800

(

73.110 )

TEMP 2 = 531.9700

(

72.300 )

TEMP 3 = 529.3200

(

69.650 )

TEMP 4 = 532.8500

(

73.180 )

TEMP 5 = 533.1400

(

73.470 )

TEMP 6 = 534.0900

(

74.420 )

TEMP 7 = 535.9400

(

76.270 )

TEMP 8 = 532.5800

(

72.910 )

TEMP 9 = 532.6200

(

72.950 )

TEMP 10 = 532.3900

(

72.720 )

TEMP 11 = 533.4300

(

73.760 )

TEMP 12 = 532.5300

(

72.860 )

1 TEMP 13 = 532.5100

(

72.840 )

TEMP 14 = 532.3600

(

72.690 )

TEMP 15 = 532.5700

(

72.900 )

TEMP 16 = 532.1400

(

72.470 )

TEMP 17 = 532.3000

(

72.630 )

TEMP 18 = 532.3800

(

72.710 )

PRES 1

73.6964

( 74164.0 )

=

PRES 2=

73.6839

( 72469.0 )

VPRS 1 =

.3111

(

65.530 )

VPRS 2=

.3080

(

65.240 )

VPRS 3=

.3070

(

65.150 )

VPRS 4 =

.3013

(

64.610 )

VPRS 5=

.3092

(

65.350 )

VPRS 6=

.3015

(

64.630 )

SUMMARY

OF CORRECTED DATA TIME = 2215 DATE = 1216 532.4908 TEMPERATURE (DEGREES R.)

=

CORRECTED PRESSURE (PSIA) =

73.3907

.3057 VAPOR PRESSURE (PSIA)

=

VOLUME (CU.FT.)

1910000.0

=

710543.9 AIR MASS (LBM) =

V C-25

SUMMARY

OF MEASURED DATA AT 2230 1216 TEMP 1 = 332.9000

(

73.230 )

TEMP 2 = 531.9800

(

72.310 )

TEMP 3 = 529.4200

(

69.750 )

TEMP 4 = 532.8400

(

73.170 )

TEMP 5 = 533.1500

(

73.480 )

TEMP 6 = 534.0500

(

74.380 )

TEMP 7 = 535.9700

(

76.300 )

TEMP 8 = 532.6000

(

72.930 )

TEMP 9 = 532.6200

(

72.950 )

TEMP 10 = 532.4100

(

72.740 )

TEMP 11 = 533.4700

(

73.800 )

TEMP 12 = 532.5900

(

72.920 )

1 TEMP 13 = 532.5100

(

72.840 )

TEMP 14 = 532.4000

(

72.730 )

TEMP 15 = 532.5900

(

72.920 )

TEMP 1G = 532.1900

(

72.520 )

TEMP 17 = 532.3300

(

72.660 )

TEMP 18 = 532.3900

(

72.720 )

PRES 1

73.6984

( 74166.0 )

=

PRES 2=

73.6859

( 72471.0 )

VPRS 1 =

.3054

(

65.000 )

VPRS 2=

.3075

(

65.190 )

VPRS 3=

.3072

(

65.160 )

VPRS 4=

.2995

(

64.440 )

VPRS 5=

.3112

(

65.540 )

VPRS 6=

.3015

(

64.630 )

SUMMARY

OF CORRECTED DATA TIME = 2230 DATE = 1216

=

532.5211 TEMPERATURE (DEGREES R.)

73.3928 CORRECTED PRESSURE (PSIA) =

.3056 VAPOR PRESSURE (PSIA)

=

VOLUME (CU.FT.)

1910000.0

=

AIR MASS (LBM) =

710523.7

[~h

\\>

C-28

SUMMARY

OF MEASURED DATA AT 2245 1216 TEMP 1 = 532.9900

(

73.3d0 )

TEMP 2 = 532.0100

(

72.340 )

TEMP 3 = 529.3000

(

69.630 )

TEMP 4 = 532.8900

(

73.220 )

TEMP 5 = 533.1900

(

73.520 )

TEMP 6 = 534.0600

(

74.390 )

TEMP 7 = 535.9800

(

76.310 :

TEMP 8 = 532.6500

(

72.980 )

TEMP' 9 = 532.6700

(

73.000 )

TEMP 10 = 532.4100

(

72.740 )

TEMP 11 = 533.4400

(

73.770 )

TEMP 12 = 532.5500

(

72.880 )

1 TEMP 13 = 532.5100

(

72.840 )

TEMP 14 = 532.3900

(

72.720 )

TEMP 15 = 532.5800

(

72.910 )

TEMP 16 = 532.2300

(

72.560 )

TEMP 17 = 532.3400

(

72.670 )

TEMP 18 = 532.4100

(

72.740 )

PRES 1 =

73.7004

( 74168.0 )

PRES 2=

73.6880

( 72473.0 )

VPRS 1 =

.3012

(

64.600 )

VPRS 2=

.3069

(

65.140 )

VPRS 3=

.3123

(

65.640 )

VPRS 4 =

.2991

(

64.400 )

VPRS 5=

.3086

(

65.290 )

VPRS 6=

.3053

(

64.990 )

SUMMARY

OF CORRECTED DATA TIME = 2245 DATE = 1216 TEMPERATURE (DEGREES R.)

532.5314

=

CORRECTED PRESSURE (PSIA) 73.3939

=

VAPOR PRESSURE (PSIA)

.3065

=

VOLUME (CU.FT.) = 1910000.0 AIR MASS (LBM) =

710520.3 V

c-27

SUMMARY

OF MEASURED DATA AT 2300 1216 TEMP 1 = 532.9900

(

73.320 )

TEMP 2 = 532.0400

(

72.370 )

TEMP 3 = 529.3900

(

69.720 )

TEMP 4 = 532.9100

(

73.240 )

TEMP

$ = 533.3000

(

73.650 )

TEMP 6 = 534.1600

(

74.490 )

TEMP 7 = 536.0000

(

76.330 )

TEMP 8 = 532.6400

(

72.970 )

TEMP 9 = 532.6500

(

72.980 )

TEMP 10 = 532.4100

(

72.740 )

TEMP 11 = 533.4500

(

73.780 )

TEMP 12 = 532.6300

(

72.960 )

1 TEMP 13 = 532.5400

(

72.870 )

TEMP 14 = 532.3900

(

72.720 )

TEMP 15 = 532.6100

(

72.940 )

TEMP 16 = 532.2100

(

72.540 )

TEMP 17 = 532. 3100

(

72.640 )

TEMP 18 = 532.4000

(

72.730 )

PRES 1 =

73.7023

( 74170.0 )

PRES 2=

73.6900

( 72475.0 )

VPRS 1 =

.3068

(

65.130 )

{

VPRS 2=

.3075

(

65.190 )

VPRS 3=

.3090

(

65.330 )

VPRS 4=

.3017

(

64.650 )

VPRS 5=

.3116

(

65.570 )

VPRS 6=

.3001

(

64.490 )

SUMMARY

OF CORRECTED DATA TIME = 2300 DATE = 1216 TEMPERATURE (DEGREES R.)

532.5536

=

CORRECTED PRESSURE (PSIA) 73.3962

=

VAPOR PRESSURE (PSIA)

.3061

=

VOLUME (CU.FT.)

1910020.0

=

AIR MASE (LBM) 710513.6

=

C;,W)

C-28

,=

SUMMARY

OF MEASURED DATA AT 2330 1216 TEMP 1 = 532.9300

(

73.260 )

TEMP 2 = 532.0800

(

72.410 )

TEMP 3 = 529.4000

(

69.750 )

TEMP 4 = 532.9200

(

73.250 )

TEMP 5 = 533.2700

(

73.600 )

TEMP 6 = 534.1700

(

74.500 )

TEMP 7 = 536.0400

(

76.370 )

TEMP 8 = 532.6900

(

73.020 )

TEMP 3 = 532.7500

(

73.080 )

TEMP 10 = 532.4600

(

72.790 )

TEMP 11 = 533.5100

(

73.840 )

TEMP 12 = 532.6000

(

72.930 )

1 TEMP 13 = 532.5900

(

72.920 )

TEMP 14 = 532.4600

(

72.790 )

TEMP 15 = 532.6900

(

73.020 )

TEMP 16 = 532.2200

(

72.550 )

TEMP 17 = 532.3700

(

72.700 )

TEMP 18 = 532.4900

(

72.820 )

73.7073

( 7*175.0 )

PRES 1 =

PRES 2=

73.6941

( 72479.0 )

VPRS 1 =

.3058

(

65.030 )

6 VPRS 2=

.3070

(

65.150 )

VPRS 3=

.3076

(

65.200 )

.2994

(

64.430 )

VPRS 4 =

VPRS 5=

.3093

(

65.360 )

VPRS 6=

.3040

(

64.860 )

SUMMARY

OF CORRECTED DATA TIME = 2330 DATE = 1216 532.5876 TEMPERATURE (DEGREES R.)

=

73.4017 CORRECTED PRESSURE (PSIA) =

.3056 VAPOR PRESSURE (PSIA) =

1910000.0 VOLUME (CU.FT.)

=

710521.1 AIR MA6S (LBM)

=

,u.

%j c-30

SUMMARY

OF MEASURED DATA AT 0 1217 6'

TEMP 1 = 533.0200

(

73.350 )

TEMP 2 = 532.1300

(

72.460 )

TEMP 3 = 529.6500

(

69.980 )

TEMP 4 = 532.9600

(

73.290 )

TEMP 5 = 533.3300

(

73.660 )

TEMP 6 = 534.2300

(

74.560 )

TEMP 7 = 536.0900

(

76.420 )

TEMP 8 = S32.6900

(

73.020 )

TEMP 9 = 532.7600

(

73.090 )

TEMP 10 = 532.4500

(

72.780 )

TEMP 11 = 533.5300

(

73.860 )

TEMP 12 = 532.6800

(

73.010 )

1 TEMP 13 = 532.6100

(

72.940 )

TEMP 14 = 532.4600

(

72.790 )

TEMP 15 = 532.7100

(

73.040 )

TEMP 16 = 532.3100

(

72.640 )

TEMP 17 = 532.4300

(

72.760 )

TEMP 18 = 532.4700

(

72.800 )

PRES 1

73.7113

( 74179.0 )

=

PRES 2=

73.6981

( 72483.0 )

VPRS 1

.3069

(

65.140 )

=

6 VPRS 2=

.3078

(

65.220 )

VPRS 3=

.3039

(

64.850 )

VPRS 4=

.3021

(

64.680 )

VPRS 5=

.3096

(

65.390 )

VPRS 6=

.3017

(

64.650 )

SUMMARY

OF CORRECTED DATA TIME =

0 DATE = 1217 TEMPERATURE (DEGREES R.)

=

532.6326 CORRECTED PRESSURE (PSIA) 73.4060

=

VAPOR PRESSURE (PSIA)

.3053

=

VOLUME (CU.FT.)

1910000.0

=

AIR MASS (LBM) 710502.6

=

,a

\\_/

1 C-32'

SUMMARY

OF MEASURED DATA AT 15 1217 TEMP 1 = 532.9500

(

73.280 )

TEMP 2 = 532.1000

(

72.430 )

TEMP 3 = 529.4600

(

69.790 )

TEMP 4 = 532.9500

(

73.280 )

TEMP 5 = 533.3800

(

73.710 )

TEMP 6 = 534.2700

(

74.600 )

TEMP 7 = 536.1400

(

76.470 )

TEMP 8 = 532.7500

(

73.080 )

TEMP 9 = 532.7900

(

73.120 )

TEMP 10 = 532.5000

(

72.830 )

TEMP 11 = 533.5800

(

73.910 )

TEMP 12 = 532.6100

(

72.940 )

1 TEMP 13 = 532.6200

(

72.950 )

TEMP 14 = 532.4900

(

72.820 )

TEMP 15 = 532.7000

(

73.030 )

TEMP 16 = 532.2900

(

72.620 )

TEMP 17 = 532.4700

(

72.800 )

TEMP 18 = 532.5200

(

72.850 )

PRES 1 =

73.7133

( 74181.0 )

PRES 2=

73.7012

( 72466.0 )

VPRS 1 =

.3017

(

64.650 )

6 VPRS 2=

.3078

(

65.220 )

VPRS 3=

.3067

(

65.120 )

VPRS 4 =

.3020

(

64.670 )

VPRS 5=

.3066

(

65.110 )

VPRS 6=

.3041

(

64.870 )

SUMMARY

OF CORRECTED DATA TIME =

15 DATE = 1217 TEMPERATURE (DEGREES R.)

532.6338

=

CORRECTED PRESSURE (PSIA) 73.4076

=

VAPOR PRESSURE (PSIA)

.3057

=

VOLUME (CU.FT.)

1910000.0

=

AIR MASS (LBM) 710516.7

=

p.

v C-33

SUMMARY

OF MEASURED DATA AT 30 1217 TEMP 1 = 533.0800

(

73.410 )

TEMP 2 = 532.1400

(

72.470 )

TEMP 3 = 529.5600

(

69.890 )

TEMP 4 = 533.0000

(

73.330 )

TEMP 5 = 533.4700

(

73.800 )

TEMP 6 = 534.2700

(

74.600 )

TEMP 7 = 536.1100

(

76.440 )

TEMP 8 = 532.7700

(

73.100 )

TEMP 9 = 532.8000

(

73.130 )

TEMP 10 = 532.5200

(

72.850 )

TEMP 11 = 533.5900

(

73.920 )

TEMP 12 = 532.6900

(

73.020 )

1 TEMP 13 = 532.6600

(

72.990 )

TEMP 14 = 532.5400

(

72.870 )

TEMP 15 = 532.7300

(

73.060 )

TEMP 16 = 532.3600

(

72.690 )

TEMP 17 = 532.4400

(

72.770 )

TEMP 18 = 532.5200

(

72.850 )

PRES 1

73.7152

( 74183.0 )

=

PRES 2=

73.7032

( 72488.0 )

VPRS 1 =

.3164

(

66.010 )

VPRS 2=

.3061

't 65.060 )

VPRS 3=

.3087

(

65.300 )

VPRS 4=

.3031

(

64.780 )

VPRS 5=

.3096

(

65.390 )

VPRS 6=

.3003

(

64.510 )

SUMMARY

OF CORRECTED DATA TIME =

30 DATE = 1217 TEMPERATURE (DEGREES R.)

532.6763

=

CORRECTED PRESSURE (PSIA) 73.4096

=

VAPOR PRESSURE (PSIA) =

.3056 VOLUME (CU.FT.) = 1910000.0 710479.8 AIR MASS (LBM)

=

O

'v C-34

SUMMARY

OF MEASURED DATA AT 345 1217 6

TEMP 1 = 533.E500

(

73.580 )

TEMP 2 = 532.4300

(

72.760 )

TEMP 3 = 529.6600

(

69.990 )

TEMP 4 = 533.3100

(

73.640 )

TEMP 5 = 533.6900

(

74.020 )

TEMP 6 = 534.4800

(

74.810 )

TEMP 7 = 536.4000

(

76.730 )

TEMP d = 533.0600

(

73.390 )

TEMP 9 = 533.0200

(

73.350 )

TEMP 10 = 532.7800

(

73.110 )

TEMD 11 = 533.8200

(

74.150 )

TEMP 12 = 533.0000

(

73.330 )

1 TEMP 13 = 532.9100

(

73.240 )

TEMP 14 = 532.8000

(

73.130 )

TEMP 15 = 532.9900

(

73.320 )

TEMP 16 = 532.6400

(

72.970 )

TEMP 17 = 532.7400

(

73.070 )

TEMP 18 = 532.8200

(

73.150 )

PRES 1

73.7381

( 74206.0 )

=

PRES 2=

73.7246

( 72509.0 )

VPRS 1 =

.3195

(

66.290 )

VPRS 2=

.3088

(

65.310 )

VPRS 3=

.3105

(

65.470 )

.3025

(

64.720 )

VPRS 4 =

VPRS 5=

.3115

(

65.560 )

VPRS 6=

.2990

(

64.390 )

SUM. VARY 00 CORRECTED DA1A TIME =

345 DATE = 1217 TEMPERATURE (DEGREES R.)

532.9381

=

CORRECTED PRESSURE (PSIA) =

73.4314 VAPOR PRESSURE (PSIA)

.3067

=

VOLUME (CU.FT.)

1910000.0

=

AIR MASS (LBM) =

710341.4 v

G-2

SUMMARY

OF MEASURED DATA AT 400 1217 TEMP 1 = 533.3300

(

73.660 )

TEMP 2 = 532.4700

(

72.800 )

TEMP 3 = 529.7100

(

70.040 )

TEMP 4 = 533.3000

(

73.630 )

TEMP

$ = 533.8500

(

74.180 )

TEMP 6 = 534.5500

(

74.880 )

TEMP 7 = 536.4200

(

76.750 )

TEMP 8 = 533.0900

(

73.420 )

TEMP 9 = 533.1200

(

73.450 )

TEMP 10 = 532.8100

(

73.140 )

TEMP 11 = 533.8800

(

74.210 )

TEMP 12 = 532.9600

(

73.290 )

1 TEMP 13 = 532.9400

(

73.270 )

TEMP 14 = 532.8100

(

73.140 )

TEMP 15 = 533.0200

(

73.350 )

TEMP 16 = 532.6100

(

72.940 )

TEMP 17 = 532.7300

(

73.060 )

TEMP 18 = 532.8300

(

73.160 )

73.7391

( 74207.0 )

PRES 1

=

PRES 2=

73.7256

( 72510.0 )

.2680

(

61.280 )

VPRS 1

=

VPRS 2=

.3074

(

65.180 )

W VPRS 3=

.3104

(

65.460 )

.3015

(

64.630 )

VPRS 4 =

VPRS S=

.3129

(

65.690 )

VPRS 6=

.3036

(

64.830 )

SUMMARY

OF CORRECTED DATA TIME =

400 DATE = 1217 532.9645 TEMPERATURE (DEGREES R.)

=

73.4319 CORRECTED PRESSURE (PSIA)

=

.3072 VAPOR PRESSURE (PSIA)

=

VOLUME (CU.FT.)

1910000.0

=

710310.9 AIR MASS (LBM)

=

es

,v G-3

SUMMARY

OF MEASURED DATA AT 415 1217 TEMP 1 = 533.3900

(

73.720 )

TEMP 2 = 532.4800

(

72.810 )

TEMP 3 = 529.6300

(

69.960 )

TEMP 4 = 533.3300

(

73.660 )

TEMP 5 = 533.7400

(

74.070 )

TEMP 6 = 534.5500

(

74.880 )

TEMP 7 = 536.4300

(

76.760 )

TEMP 8 = 533.0500

(

73.380 )

TEMP 9 = 533.1000

(

73.430 )

TEMP 10 = 532.8400

(

73.170 )

TEMP 11 = 533.9100

(

74.240 )

TEMP 12 = 533.0200

(

73.350 )

1 TEMP 13 = 532.9500

(

73.280 )

TEMP 14 = 532.8400

(

73.170 )

TEMP 15 = 533.0600

(

73.390 )

TEMP 16 = 532.6300

(

72.960 )

TEMP 17 = 532.7700

(

73.100 )

TEMP 18 = 532.8500

(

73.180 )

PRES 1 =

73.7391

( 74207.0 )

PRES 2=

73.7256

( 76510.0 )

VPRS 1 =

.3034

(

64.810 )

VPRS 2=

.3094

(

65.370 )

VPRS 3=

.3096

(

65.390 )

VPRS 4 =

.2995

(

64.440 )

VPRS 5=

.3128

(

65.680 )

VPRS 6=

.3017

(

64.650 )

SUMMARY

OF CORRECTED DATA TIME =

415 DATE = 1217 532.9795

)

TEMPERATURE (DEGREES R.)

=

CORRECTED PRESSURE (PSIA) 73.4322

=

.3069 VAPOR PRESSURE (PSIA)

=

1910000.0 VOLUME (CU.FT.)

=

710293.8 AIR MASS (LBM) =

l hb i

G-4

SUMMARY

OF MEASURED DATA AT 430 1217 TEMP 1 = 533.3200

(

73.650 )

TEMP 2 = 532.4900

(

72.820 )

TEMP 3 = 529.8200

(

70.150 )

TEMP 4 = 533.4100

(

73.740 )

TEMP 5 = 533.7000

(

74.030 )

TEMP 6 = 534.5800

(

74.910 )

TEMP 7 = 536.4500

(

76.780 )

TEMP 8 = 533.1100

(

73.440 )

TEMP 3 = 533.1500

(

73.460 )

TEMP 10 = 532.8600

(

73.190 )

TEMP 11 = 533.9100

(

74.240 )

TEMP 12 = 533.1100

(

73.440 )

1 TEMP 13 = 532.9700

(

73.300 )

TEMP 14 = 532.8600

(

73.190 )

TEMP 15 = 533.0700

(

73.400 )

TEMP 16 = 532.6700

(

73.000 )

TEMP 17 = 532.7900

(

73.120 )

TEMP 18 = 532.8600

(

73.190 )

PRES 1 =

73.7401

( 742G8.0 )

PRES 2=

73.7266

( 72511.0 )

VPRS 1 =

.3083

(

65.270 )

VPRS 2=

.3086

(

65.290 )

VPRS 3=

.3073

(

65.170 )

VPRS 4 =

.3007

(

64.550 )

VPRS 5=

.3108

(

65.500 )

VPRS 6=

.3014

(

64.620 )

SUMMARY

OF CORRECTED DATA TIME =

430 DATE = 1217 TEMPERATURE (DEGREES R.)

=

533.0035 CORRECTED PRESSURE (PSIA) =

73.4340 VAPOR PRESSURE (PSIA)

.3060

=

VOLUME (CU.FT.)

1910000.0

=

AIR PASS (LBM) =

710279.6

('~b U

G-5

SUMMARY

OF MEASURED DATA AT 445 1217 TEMP 1 = 533.4200

(

73.750 )

TEMP 2 = 532.5400

(

72.870 )

TEMP 3 = 529.9400

(

70.270 )

TEMP 4 = 533.3800

(

73.710 )

TEMP 5 = 533.8300

(

74.160 )

TEMP 6 = 534.6000

(

74.930 )

TEMP 7 = 536.4800

(

76.810 )

TEMP 8 = 533.1200

(

73.450 )

TEMP 9 = 533.1800

(

73.510 )

TEMP 10 = 532.9000

(

73.230 )

TEMP 11 = 533.9500

(

74.280 )

TEMP 12 = 533.1000

(

73.430 )

1 TEMP 13 = 533.0100

(

73.340 )

TEMP 14 = 532.8600

(

73.190 )

TEMP 15 = 533.0900

(

73.420 )

TEMP 16 = 532.7400

(

73.070 )

TEMP 17 = 532.8300

(

73.160 )

TEMP 18 = 532.8800

(

73.210 )

PRES 1 =

73.7411

( 74209.0 )

PRES 2=

73.7276

( 72512.0 )

VPRS 1

.3081

(

65.250 )

=

VPRS 2=

.3086

(

65.290 )

6 VPRS 3=

.3053

(

64.990 )

VPRS 4 =

.3007

(

64.550 )

VPRS 5=

.3120

(

65.610 )

VPRS 6=

.3017

(

64.650 )

SUMMARY

OF CORRECTED DATA TIME =

445 DATE = 1217 TEMPERATURE (DEGREES R.)

=

533.0435 CORRECTED PRESSURE (PSIA) 73.4351

=

VAPOR PRESSURE (PSIA)

.3060

=

VOLUME (CU.FT.) =

1910000.0 AIR MASS (LBM) =

71w236.8

[\\_/

G-6

SUMMARY

OF MEASURED DATA AT 500 1217 TEr1P 1 = 533.4300

(

73.760 )

TEMP 2 = 532.5400

(

72.870 )

TEMP 3 = 529.8700

(

70.200 )

TEMP 4 = 533.3800

(

73.710 )

TEMP

$ = 533.9000

(

74.230 )

TEMP 6 = 534.6600

(

74.990 )

TEMP 7 = 536.5000

(

76.830 )

TEMP 8 = 533.1400

(

73.470 )

TEMP 3 = 533.1800

(

73.510 )

TEMP 10 = 532.8900

(

73.220 )

TEMP 11 = 533.9300

(

74.260 )

TEMP 12 = 533.0900

(

73.420 )

1 TEMP 13 = 533.0400

(

73.370 )

TEMP 14 = 532.8900

(

73.220 )

TEMP 15 = 533.1000

(

73.430 )

TEMP 16 = 532.7200

(

73.050 )

TEMP 17 = 532.8300

(

73.160 )

TEMP 18 = 532.9500

(

73.280 )

73.7411

( 74209.0 )

PRES 1 =

PRES 2=

73.7286

( 72513.0 )

.3096

(

65.390 )

VPRS 1

=

VPRS 2=

.3092

(

65.350 )

VPRS 3=

.3078

(

65.220 )

VPRS 4=

.2994

(

64.430 )

VPRS 5=

.3119

(

65.600 )

VPRS 6=

.3036

(

64.830 )

SUMMARY

OF CORRECTED DATA TIME =

500 DATE = 1217 533.058d TEMPERATURE (DEGREE 5 R.)

=

73.4344 CORRECTED PRESSURE (PSIA)

=

.3067 VAPOR PRES 5URE (PSIA)

=

VOLUME (CU.FT.)

1910000.0

=

AIR MAES (LBM) =

710210.2

(~s i

l

%J G-7

SUMMARY

OF MEASURED DATA AT 515 1217 TEMP 1 = 533.4000

(

73.730 )

TEMP 2 = 532.5800

(

72.910 )

TEMP 3 = 529.9300

(

70.260 )

TEMP 4 = 533.4200

(

73.750 )

TEMP 5 = 533.8100

(

74.140 )

TEMP 6 = 534.5600

(

74.890 )

TEMP 7 = 536.5600

(

76.890 )

TEMP 8 = 533.1900

(

73.520 )

TEMP 9 = 533.1700

(

73.500 )

TEMP 10 = 532.9400

(

73.270 )

TEMP 11 = 533.9600

(

74.290 )

TEMP 12 = 533.1100

(

73.440 )

1 TEMP 13 = 533.0400

(

73.370 )

TEMP 14 = 532.9100

(

73.240 )

TEMP 15 = 533.1400

(

73.470 )

TEMP 16 = 532.7500

(

73.060 )

TEMP 17 = 532.8300

(

73.160 )

TEMP 18 = 532.9300

(

73.260 )

PRES 1 =

73.7430

( 74211.0 )

PRES 2=

73.7297

( 72514.0 )

.2957

(

64.070 )

VPRS 1

=

VPRS 2=

.3091

(

65.340 )

VPRS 3=

.3102

(

65.440 )

.3027

(

64.740 )

VPRS 4 =

VPRS 5=

.3091

(

65.340 )

VPRS 6=

.3026

(

64.750 )

SUMMARY

OF CORRECTED DATA TIME =

515 DATE = 1217 533.0646 TEMPERATURE (DEGREES R.)

=

CORRECTED PRESSURE (PSIA) =

73.4361

.3070 VAPOR PRESSURE (PSIA)

=

1910000.0 VOLUME (CU.FT.)

=

710218.1 AIR MASS (LBM) =

gx U

G-4

r

SUMMARY

OF MEASURED DATA AT 530 1217 TEMP 1 = 533.4600

(

73.750 )

TEMP 2 = 532.5700

(

72.900 )

TEMP 3 = 529.9800

(

70.310 )

TEMP 4 = 533.4600

(

73.790 )

TEMP 5 = $33.8100

(

74.140 )

TEMP 6 = 534.5600

(

74.890 )

TEMP 7 = 536.5400

(

76.870 )

TEMP 8 = 533.2300

(

73.560 )

TEMP 3 = 533.2200

(

73.550 )

TEMP 10 = 532.9400

(

73.270 )

TEMP 11 = 533.9900

(

74.320 )

TEMP 12 = 533.1200

(

73.450 )

1 TEMP 13 = 533.0700

(

73.400 )

TEMP 14 = 532.9400

(

73.270 )

TEMP 15 = 533.1600

(

73.490 )

TEMP 16 = 532.7500

(

73.080 )

TEMP 17 = 532.8800

(

73.210 )

TEMP 18 = 532.9600

(

73.290 )

PRES 1 =

73.7440

( 74212.0 )

PRES 2=

73.7307

( 72515.0 )

VPRS 1 =

.3120

(

65.610 )

VPRS 2=

.3081

(

65.250 )

VPRS 3=

.3264

(

65.090 )

VPRS 4 =

.3065

(

65.100 )

VPRS 5=

.3117

(

65.580 )

VPRS 6=

.3030

(

64.770 )

SUMMARY

OF CORRECTED DATA TIME =

530 DATE = 1217 TEMPERATURE (DEGREES R.) =

533.0873 CORRECTED PRESSURE (PSIA) 73.4368

=

VAPOR PRESSURE (PSIA)

.3072

=

VOLUME (CU.FT.)

1910000.0

=

AIR VASS (LBM) =

710194.6 (G

3 G-9

~.

SUMMARY

OF MEASURED DATA AT 545 1217 TEMP 1 = 533.4600

(

73.790 )

TEMP 2 = 532.6100

(

72.940 )

i TEMP 3 = 529.9800

(

70.310 )

TEMP 4 = 533.4700

( '73.800 )

TEMP 5 = 533.8300

(

74.160 )

TEMP 6 = 534.6500

(

74.980 )

TEMP 7 = 536.5800

(

76.910 )

TEMP 6 = 533.2300

(

73.560 )

TEMP 9 = 533.2400

(

73.570 )

TEMP 10 = 532.9500

(

73.280 )

TEMP 11 = 534.0300

(

74.360 )

TEMP 12 = 533.2000

(

73.530 )

1 TEMP 13 = 533.0800

(

73.410 )

TEMP 14 = 532.9600

(

73.290 )

TEMP 15 = 533.1500

(

73.480 )

TEMP 16 = 532.8200

(

73.150 )

TEMP 17 = 532.8500

(

73.180 )

TEMP 18 = 532.9800

(

73.310 )

73.7450

( 74213.0 )

PRES 1 =

PRES 2=

73.7317

( 72516.0 )

.3012

(

64.600 )

VPRS 1

=

VPRS 2=

.3082

(

65.260 )

VPRS 3=

.3083

(

65.270 )

VPRS 4 =

.3041

(

64.870 )

VPRS 5=

.3096

(

65.390 )

VPRS 6=

.3026

(

64.750 )

SUMMARY

OF CORRECTED DATA TIME =

545 DATE = 1217 TEMPERATURE (DEGREES R.) =

533.1104 73.4383 CORRECTED PRESSURE (PSIA)

=

.3067 VAPOR PRESSURE (PSIA) =

1910000.0 VOLUME (CU.FT.)

=

710178.4 AIR MASS (LBM)

=

/~N

)

w/

G-10

6'

SUMMARY

OF MEASURED DATA AT 600 1217 TEMP 1 = 533.5300

(

73.860 )

TEMP 2 = 532.6400

(

72.970 )

TEMP 3 = 530.0400

(

70.370 )

TEMP 4 = 533.4500

(

73.780 )

TEMP 5 = 533.8700

(

74.200 )

TEMP 6 = 534.6400

(

74.970 )

TEMP 7 = 536.5600

(

76.890 )

TEMP 8 = 533.2400

(

73.570 )

TEMP 9 = 533.2100

(

73.540 )

TEMP 10 = 533.0000

(

73.330 )

TEMP 11 = 534.0600

(

74.390 )

TEMP 12 = 533.1800

(

73.510 )

1 TEMP 13 = 533.0900

(

73.420 )

TEMP 14 = 533.0100

(

73.340 )

TEMP 15 = 533.2200

(

73.550 )

TEMP 16 = 532.8100

(

73.140 )

TEMP 17 = 532.8900

(

73.220 )

TEMP 18 = 533.0100

(

73.340 )

PRES 1

73.7460

( 74214.0 )

=

PRES 2=

73.7327

( 72517.0 )

VPRS 1 =

.2890

(

63.420 )

VPRS 2=

.3093

(

65.360 )

VPRS 3=

.3129

(

65.690 )

VPRS 4 =

.3044

(

64.900 )

VPRS 5=

.3130

(

65.700 )

VPRS 6=

.3035

(

64.820 )

SUMMARY

OF CORRECTED DATA TIME =

600 DATE = 1217 TEMPERATURE (DEGREES R.) =

533.1364 CORRECTED PRESSURE (PSIA) =

73.4373 VAPOR PRESSURE (PSIA)

.3087

=

VOLUME (CU.FT.) =

19100GiO. 0 AIR MA5E (LBM) 710134.6

=

~/ 'T

, u G-11

SUMMARY

OF MEASURED DATA AT 615 1217

(\\

.O TEMP 1 = 533.5400

(

73.870 )

TEMP 2 = 532.6700

(

73.000 )

TEMP 3 = 530.1000

(

70.430 )

TEMP 4 = 533.5100

(

73.840 )

TEMP 5 = 533.8300

(

74.160 )

TEMP 6 = 534.6800

(

75.010 )

TEMP 7 = 536.6300

(

76.960 )

TEMP 8 = 533.3700

(

73.700 )

TEMP 9 = 533.2500

(

73.580 )

TEMP 10 = 532.9700

(

73.300 )

TEMP 11 = 534.0500

(

74.380 )

TEMP 12 = 533.2100

(

73.540 )

1 TEMP 13 = 533.1200

(

73.450 )

TEMP 14 = 532.9800

(

73.310 )

TEMP 15 = 533.2000

(

73.530 )

TEMP 16 = 532.8300

(

73.160 )

TEMP 17 = 532.9400

(

73.270 )

TEMP 18 = 533.0200

(

73.350 )

73.7460

( 74214.0 )

PRES 1 =

PRES 2=

73.7327

( 72517.0 )

.2961

(

64.110 )

VPRS 1 =

T VPRS 2=

.3092

(

65.350 )

)

VPRS 3=

.3107

(

65.490 )

+

VPRS 4=

.3047

(

64.930 )

VPRS 5=

.3111

(

65.530 )

VPRS 6=

.3061

(

65.060 )

SUMMARY

OF CORRECTED DATA TIME =

615 DATE = 1217 533.1517 TEMPERATURE (DEGREES R.)

=

73.4376 CORRECTED PRESSURE (PSIA) =

.3084 VAPOR PRESSURE (PSIA)

=

1910000.0 VOLUME (CU.FT.)

=

710116.4 AIR MASS (LBM)

=

n u

G-12

SUMMARY

OF MEASURED DATA AT 630 1217 TEMP 1 = 533.5800

(

73.910 )

TEMP 2 = 532.6700

(

73.000 )

TEMP 3 = 530.0200

(

70.350 )

TEMP 4 =

533.5500

( ~73.880 )

TEMP 5 = 533.9100

(

74.240 )

TEMP 6 = 534.6300

(

74.960 )

TEMP 7 = 536.6400

(

76.970 )

TEMP 8 = 533.3700

(

73.700 )

TEMP 3 = 533.2800

(

73.610 )

TEMP 10 = 533.0300

(

73.360 )

TEMP 11 = 534.0800

(

74.410 )

TEMP 12 = 533.2300

(

73.560 )

g TEMP 13 = 533.1300

(

73.460 )

TEMP 14 = 532.9900

(

73.320 )

TEMP 15 = 533.2000

(

73.530 )

TEMP 16 = 532.8100

(

73.140 )

TEMP 17 = 532.9200

(

73.250 )

TEMP 18 = 533.0200

(

73.350 )

PRES 1 =

73.7480

( 74216.0 )

PRES 2=

73.7337

( 72518.0 )

VPRS 1 =

.3049

(

64.950 )

VPRS 2=

.3095

(

65.380 )

VPRS 3=

.3122

(

65.639 )

VPRS 4 =

.3057

(

65.020 )

VPRS 5=

.3133

(

65.730 )

VPRS 6=

.3032

(

64.790 )

SUMMARY

OF CORRECTED DATA TIME =

630 DATE = 1217 TEMPERATURE (DEGREES R.)

533.1602

=

CORRECTED PRESSURE (PSIA) 73.4392

=

VAPOR PRESSURE (PSIA)

.3089

=

VOLUME (CU.FT.) =

1910000.0 AIR MASS (LBM) =

710120.3 G-13

.,s 4'

SUMMARY

OF MEASURED DATA AT 645 1217 TEMP 1 = 533.5500

(

73.880 )

TEMP 2 = 532.6800

(

73.010 )

TEMP 3 = 530.1800

(

70.510 )

TEMP 4 = 533.5400

(

73.870 )

TEMP 5 = 533.8900

(

74.220 )

TEMP 6 = 534.6400

(

74.970 )

TEMP 7 = 536.6300

(

76.960 )

TEMP d = $33.3900

(

73.720 )

TEMP 9 = 533.3200

(

73.650 )

TEMP 10 = 533.0600

(

73.390 )

TEMP 11 = 534.0900

(

74.420 )

TEMP 12 = 533.2700

(

73.600 )

1 TEMP 13 = 533.1700

(

73.500 )

TEMP 14 = 532.9900

(

73.320 )

TEMP 15 = 533.2700

(

73.600 )

TEMP 16 = 532.8900

(

73.220 )

TEMP 17 = 532.9800

(

73.310 )

TEMP 18 = 533.0700

(

73.400 )

PRES 1 =

73.7480

( 74216.0 )

PRES 2=

73.7347

( 72519.0 )

VPRS 1 =

.3125

(

65.660 )

('

VPRS 2=

.3082

(

65.260 )

\\_/

VPRS 3=

.3094

(

65.370 )

.3015

(

64.6I0 )

VPRS 4 =

VPRS 5=

.3158

(

65.960 )

VPRS 6=

.3028

(

64.750 )

SUMMARY

OF CORRECTED DATA TIME =

645 DATE = 1817 TEMPERATURE (DEGREES R.) =

533.1946 CORRECTED PRESSURE (PSIA) 73.4404

=

VAPOR PRESSURE (PSIA)

=

.3076 VOLUME (CU.FT.) = 1910000.0 710066.5 AIR MASS (LBM)

=

(~h d

G-14

SUMMARY

OF MEASURED DATA AT 700 1217 6

TEMP 1 = 533.4500

(

73.780 )

TEMP 2 = 532.7200

(

73.050 )

TEMP 3 = 530.3200

(

70.650 )

TEMP 4 = 533.5600

(

73.890 )

TEMP 5 = 533.9900

(

74.320 )

TEMP 6 = 534.6500

(

74.980 )

TEMP 7= 536.6700

(

77.000 )

TEMP 8 = 533.4000

(

73.730 )

TEMP 9 = 533.3900

(

73.720 )

TEMP 10 = 533.0700

(

73.400 )

TEMP 11 = 534.1400

(

74.470 )

TEMP 12 = 533.2300

(

73.560 )

y TEMP 13 = 533.1800

(

73.510 )

TEMP 14 = 533.0200

(

73.350 )

TEMP 15 = 533.2700

(

73.600 )

TEMP 16 = 532.8700

(

73.200 )

TEMP 17 = 532.9900

(

73.320 )

TEMP 18 = 533.0500

(

73.380 )

PRES 1 =

73.7490

( 74217.0 )

PRES 2=

73.7347

( 72519.0 )

VPRS 1 =

.3199

(

66.330 )

VPRS 2=

.3090

(

65.330 )

VPRS 3=

.3099

(

65.420 )

VPRS 4 =

.3014

(

64.620 )

VPRS 5=

.3144

(

65.830 )

VPRS 6=

.3075

(

65.190 )

SUMMARY

OF CORRECTED DATA TIME =

700 DATE = 1217 TEMPERATURE (DEGREES R. )

533.204*

=

CORRECTED PRESSURE (PSIA) 73.4405

=

VAPOR PRESSURE (PSIA)

.3085

=

VOLUME (CU.FT.)

1910000.0

=

AIR MASS (LBM) 710074.6

=

7~

(,

G-15 w

-m-

SUMMARY

OF MEASURED DATA AT 715 1217 TEMP 1 = 533.4400

(

73.770 )

TEMP 2 = 532.7500

(

73.080 )

TEMP 3 = 530.1600

(

70.490 )

TEMP 4 = 533.6100

'(

73.940 )

TEMP 5 = 533.9400

(

74.270 )

TEMP 6 = 534.7600

(

75.090 )

TEMP 7 = 536.7100

(

77.040 )

TEMP 8 = 533.4500

(

73.760 )

TEMP 9 = 533.3500

(

73.680 )

TEMP 10 = 533.0900

(

73.420 )

TEMP 11 = 534.1600

(

74.490 )

TEMP 12 = 533.2900

(

73.620 )

1 TEMP 13 = 533.2100

(

73.540 )

TEMP 14 = 533.0800

(

73.410 )

TEMP 15 = 533.3100

(

73.640 )

TEMP 16 = 532.8700

(

73.200 )

TEMP 17 = 533.0200

(

73.350 )

TEMP 18 = 533.0900

(

73.4E0 )

PRES 1 =

73.7490

( 74217.0 )

PRES 2=

73.7358

( 725EO.0 )

VPRS 1 =

.3132

(

65.720 )

VPRS 2=

.3094

(

65.370 )

VPRS 3=

.3096

(

65.390 )

VPRS 4 =

.3017

(

64.650 )

VPRS 5=

.3084

(

65.280 )

VPRS 6=

.3075

(

65.190 )

SUMMARY

OF CORRECTED DATA TIME =

715 DATE = 1217 TEMPERATURE (DEGREr; 533.2273 r-CORRECTED PRESSURE C sit 73.4415 VAPOR PRESSURE (PSIA)

.3075

=

VOLUME (CU.FT.)

1910000.0

=

AIR MASS-(LBM) 710053.3

=

/~'T

\\

L G-16

.., r =

SUMMARY

OF MEASURED DATA AT 730 1217 6

TEMP 1 = 533.4900

(

73.820 )

TEMP 2 = 532.7500

(

73.080 )

TEMP 3 = 530.1600

(

70.490 )

TEMP 4 = 533.6000

'(

73.930 )

TEMP 5 = 533.9300

(

74.260 )

TEMP 6 = 534.7500

(

75.080 )

TEMP 7 = 536.6900

(

77.020 )

TEMP 8 = 533.4200

(

73.750 )

TEMP 9 = 533.4000

(

73.750 )

TEMP 10 = 533.1200

(

73.450 )

TEMP 11 = 534.1600

(

74.490 )

TEMP 12 = 533.2700

(

73.600 )

TEMP 13 = 533.2300

(

73.560 )

TEMP 14 = 533.1100

(

73.440 )

TEMP 15 = 533.3200

(

73.650 )

TEMP 16 = 532.9100

(

73.240 )

TEMP 17 = 533. 0100

(

73.340 )

TEMP 18 = 533.1100

(

73.440 )

PRES 1 =

73.7510

( 74219.0 )

PRES 2=

73.7368

( 72521.0 )

VPRS 1 =

.3212

(

66.450 )

,/ N VPRS 2=

.3092

(

65.350 )

(,j VPRS 3=

.3122

(

65.630 )

VPRS 4=

.3004

(

64.520 )

VPRS 5=

.3161

(

65.990 )

VPRS 6=

.3033

(

64.800 )

SUMMARY

OF CORRECTED DATA TIME =

730 DATE = 1217 TEMPERATURE (DEGREES R.)

533.2377

=

CORRECTED PRESSURE (PSIA) 73.4426

=

VAPOR PRESSURE (PSIA)

.3083

=

VOLUME (CU.FT.)

1910000.0

=

AIR MASS. (LBM) 710050.8

=

.O

\\,.

G-17

+

SUMMARY

OF MEASURED DATA AT 745 1217 TEMP 1 = 533.3900

(

73.720 )

TEMP 2 = 532.7900

(

73.120 )

TEMP 3 = 530.3100

(

70.640 )

TEMP 4 = 533.6500

'(

73.960 )

TEMP 5 = 534.0400

(

74.370 )

TEMP 6 = 534.7200

(

75.0S0 )

TEMP 7 = 536.7100

(

77.040 )

TEMP 8 = 533.4600

(

73.790 )

TEMP 9 = 533.3800

(

73.710 )

TEMP 10 = 533.1000

(

73.430 )

TEMP 11 = 534.1800

(

74.510 )

TEMP 12 = 533.2700

(

73.600 )

TEMP 13 = 533.2400

(

73.570 )

TEMP 14 = 533.1300

(

73.460 )

TEMP 15 = 533.3400

(

73.670 )

TEMP 16 = 532.9000

(

73.230 )

TEMP 17 = 533.0400

(

73.370 )

TEMP 18 = 533.1500

(

73.480 )

PRES 1

73.7520

( 74220.0 )

=

PRES

&=

73.7378

( 72522.0 )

VPRS 1

.3072

(

65.160 )

=

VPRS 2=

.3096

(

65.390 )

VPRS 3=

.3114

(

65.550 )

VPRS 4 =

.3041

(

64.870 )

VPRS 5=

.3119

(

65.600 )

VPRS 6=

.3024

(

64.710 )

SUMMARY

OF CORRECTED DATA TIME =

745 DATE = 1217 TEMPERATURE (DEGREES R.) =

533.2577 CORRECTED PRESSURE (PSIA) 73.4439

=

VAPOR PRESSURE (PSIA)

.3060

=

VOLUME (CU.FT.)

1910000.0

=

AIR MASS (LBM) 710036.9

=

[N V

G-18

____