ML20128J933

From kanterella
Jump to navigation Jump to search
Forwards Insp Repts 50-348/96-07 & 50-364/96-07 on 960721-0831 & Notices of Violation & Deviation
Date released: 05/21/2020 Download: ML20128J933


Insp Repts 50-348/96-07 & 50-364/96-07 on 960721-0831. Violations Noted.Major Areas Inspected:Operations,Maint, Engineering,Plant Support
ML20128J976
Person / Time
Site: Farley 
Issue date: 09/27/1996
From:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To:
References
Download: ML20128J976 (30)
Notice of Deviation from Insp on 960721-0831.Deviation Noted:Util Failed to Fulfill Commitments When Implementing TS Amend Changes Approved 950928,by NRC in FOL Amend Numbers 116 for Unit 1 & 108 for Unit 2
ML20128J971
Person / Time
Site: Farley 
Issue date: 09/27/1996
From:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To:
References
Download: ML20128J971 (2)
Notice of Violation from Insp on 960721-0831.Violation Noted:Unit 1 Nis IR Channel Compensating Voltage for NI-35 Was Adjusted by Plant Technicians,Being Below Scale & SR Counts Were Less than 100 Cps
ML20128J958
Person / Time
Site: Farley 
Issue date: 09/27/1996
From:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To:
References
Download: ML20128J958 (2)
Forwards Insp Repts 50-348/96-07 & 50-364/96-07 on 960721-0831 & Notices of Violation & Deviation
ML20128J928
Person / Time
Site: Farley 
Issue date: 09/27/1996
From: Skinner P
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To: MOREY D N
SOUTHERN NUCLEAR OPERATING CO.
References
Download: ML20128J928 (4)