ML20128H927
| ML20128H927 | |
| Person / Time | |
|---|---|
| Site: | Kewaunee |
| Issue date: | 02/13/1993 |
| From: | Schrock C WISCONSIN PUBLIC SERVICE CORP. |
| To: | NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM) |
| References | |
| CON-NRC-93-030, CON-NRC-93-30 NUDOCS 9302170231 | |
| Download: ML20128H927 (52) | |
Text
l WPSC (414) 433-1500 NRC-93-030-TELECOPtER (414) 433-5544 EASYLINK 62891993 WISCONSIN PUBLIC SERVICE CORPORATION 600 North Adams
- P.O Box 19002
- Green Bay, $N154307-9002 February 13, 1993 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555 Gentlemen:
Docket 50-305 Operating License DPR-43 Kewaunee Nuclear Power Plant Notification of Compliance With 10 CFR 50 Apnendix E Sestion VL Emergency Response Data System
References:
1)
Letter from C.A. Schrock (WPSC) to Document Control Desk (NRC) dated October 28,1991 2)
Letter from A.G. Hansen (NRC) to C. A. Schrock (WPSC) dated March 24,1992 This is to infonn you that all actions necessary to ensure compliance with the requirements of 10 CFR 50 Appendix E, Section VI, " Emergency Response Data System" (ERDS) have been completed.
In Reference 1, we submitted our ERDS Implementation Program Plan for NRC staff review.
This staff review, documented in Reference 2, concluded that our implementation plan provided the basis for an acceptable implementation of ERDS at the Kewaunee Nuclear Power Plant.
In our October 28,1991 submittal, we deceribed several administrative elements of the plan in a conceptual manner and provided a copy of our proposed ERDS Data Point Library. During the course of our. implementation activities, we finalized the administrative elements and enhanced the Data Point Library by the addition of four new data points not previously available for transmission to the NRC.
Attachment I to this letter provides a summary of WPSC's activities to ensure compliance with the requirements of 10 CFR 50, Appendix E, Section VI. This attachment addresses the
/
9302170231Y30213
[h
{
PDR ADOCK 05000305 F
PDR I
i
P t
1 k.
ATTACHMENT 1 To Letter from C A. Schrock (WPSC) to Document Control Desk (NRC)
Dated Febmary 13,1993 ACTIVITIES TO COMPLY WITH EMERGENCY RESPONSE DATA SYSTEM Installation and Testing of ERDS Hardware Activation of ERDS Control of Changes to ERDS Hardware and Software Quarterly Testing ERDS Data Point Library
l i,
Document Control Desk Febmary 13,1993, Page 1 Installation and Testing of ERDS Hardware The installation of the ERDS Hardware in the Technical Support Center is complete. The temporary telephone line refen:nced in our October 28,1991 submittal has been replaced with a pemianent telephone line.
A formal test of the system was successfully completed with the NRC ERDS contractor, Halliburton NUS Environmental Corporation, on September 23,1992. The test was perfonned in accordance with NRC-312 "ERDS Licensee Site Installation Test Procedure, Single-Feeder System Sites". This test also demonstrated the 15 second update capability required by 10 CFR 50 Appendix E, Section VI.2.b.
On Febmary 10, 1993, si additional test of the ERDS system was conducted with the NRC Operations Center. This test validated our quarterly test procedure and verified the transmission of the four ne?r data points discussed in "ERDS Data Point Library" below.
tictivation of the ERDS 10 CFR 50.72 (a)(4) requires the activation of the ERDS not later than one hout after declaring an emergency class of alert, site area emergency, or general emergency.
Our October 28,1991 submittal discussed the control of this activation by the addition of a step to an existing Emergency Plan Implementing Procedure (EPIP) and documentation of the activation time on an EPIP form.
The activation of the ERDS is procedurally directed by the following three EPIPs:
- EP-TSC-1," Technical Support Center Organization"
- EP-TSC-2," Technical Support Center Activation"
- EP-AD-4," Alert, Site Emergency, or General Emergency" The use of these procedures will ensure the ERDS is activated in accordance with the-requirements of 10 CFR 50.72 and documentation is provided.
LIC\\NRC\\ERDS
l\\
I
~
Document Control Desk Febmary 13,1993. Page 2 Under separate letter dated February 13, 1993, WPSC has submitted revisions to these three procedures pursuant to the requirements of 10 CFR 50, Appendix E, Section V.
CLmimLof. Changes to ERDS Hatdware and,SoflEatt A
10 CFR 50 Appendix B Section VI.3.a requires any hardware and software changes that affect j
the ERDS Data Point Library must be submitted to the NRC within 30 days after the changes are completed.10 CFR $0 Appendix E,Section VI.3.b requires hardware and software changes that could aft'ect the transmission fonnat and computer communication protocol to the ERDS be provided to NRC at least 30 days print to moditkation.
Our October 28,1991 submittal stated our plans to incorporate these requirements into a KNPP Software Control Procedum (SCP). WPSC has detennined the use of a specific proc: dure is warranted. Emergency Plan Maintenance Procedure (EPMP) 9.5, " Control of ERDS Hardware and Software" has been developed to incorporate the above regulatory requirements. This procedure will provide appropriate control to ensure the requirements are met.
Qparterly Testing 10 CFR 50 Appendix E, Section I requires quarterly testing of the ERDS. Our October 28, 1991 submittal anticipated this testing would be perforried and documented using an existing Engineering Control Procedute.
A new EPMP 9.4, "Emergen' y Response Data System Testing" has been implemented that will assure these requirements are met.
This procedure was written to address the petiodic test schedule recommended by the NRC as published in the Federal Register on August 20,1992. For Kewaunec, this corresponds to the scheduled perfonnance of the quarterly test on the Tuesday of the ninth week of each calendar
- quaner, u
LIC\\NRC\\ERDS I
ma
--,,--_w-.--------
a Document Control Desk February 13,1993 Page 2
- finalization of administrative elements and provides a summary of the changes being made to the Data Point Libniry. to this letter provides a tuvised Data Point Libntry. This reflects the addition of the four new data points and other minor changes to the previously submitted Data Point Library. We request these changes be included, if possible, in the issuance of the staff's safety evaluation for the Data Point Library that was noted in Refexnce 2.
Under separate letter dated Febniary 13, 1993, WPSC has submitted Irvisions to three Radiological Emergency Plan Implementing Procedures (EPIPs) pursuant to the recuirements of 10 CFR 50 Appendix E, Section V._ These revisions ensure activation of the 9RDS is completed within the one hour time frame as specified in 10 CFR 50.72_(a)(4).
Pursuant to 10 CFR 50.4, two additional copies of _this letter and attachment are hereby submitted to Mr. A. Bert Davis, Regional Administrator, U. S. Nuclear Regulatory Commission, Region III, Glen Ellyn, Illinois.
As required, one copy of this letter and atniclunent is also submitted to the Kewaunce Nuclear Power Plant NRC Resident inspector.
If you have nny questions or comments regarding this submittal, please contact Ms. Victoria Cuneo at (414) 4331685.
Sincerely, 0(f.,ko$~r C. A. Schreck Manager - Nuclear Engineering VJC
- Attach, cc - US NRC - Region III (2 copies) w/ attach.
Mr.' Patrick Castleman, US NRC w/ attach.
Mr. P S. Cullen, PSCW w/o attach.
LIC\\NRC\\ERDS
- }
I
~
Document Control Desk Februaly 13,1993, Page 3 ERDS DaliLIbint LibraII transmits our current Data Point Library. This revision reflects the addition of new data points and other minor changes made since our previous submittal on October 28, 1991. A summary of these changes is provided below:
1.
Two new data points (F800*
<,nd F8002G) have been added for high pressure safety injection Dow.
2.
A new data point (T1000A) has been added for containment temperature.
3.
A new data point (L8008A) has been added for borated water storage tni 'evel.
4.
The source range nuclear instrumentation data point (N8031G) engineering units have been changed from deca counts per second (dkps) to counts per second (eps).
5.
The reactor coolant flow data points' (F8007G and F8008G) range corresponding to 100% flow have been changed to refiect the 1992 steam generator tube plugging.
6.
The containment pressure instmmentation data point (P8004A) engineering units has been changed from pressure in gage units (psig) to differential pressure (psid).
The Kewaunce ERDS Data Point Library has been reviewed against the list of selected parameters required by 10 CFR 50, Appendix E, Section VI.2.a(i). With the exception of narrow range containment sump level, Kewaunce's transmitted plant parameters meet or exceed the requirements of 10 CFR 50.
Containment sump narrow range level is not available on the plant computer, and therefore, is not tmnsmitted. Containment sun.p wide range level is transmitted. As stated in Section VI.1 of Appendix E, retrofitting of data points is not re-quired.
The issue of containment sump level instzumentation has been the subject of previous transmittals in response to Regulatory Guide (RG) 1.97 and Generic Letter 82-33. RG 1.97 recommended the use of both wide-range and narrow-range containmenthmp water level instiumentation.
In previous submittals, WPSC concluded that the resolution of the wide range instmmentation LIC\\NRC\\ERDS
(
l Document Control Desk Febniary 13,1993, Page 4 was adequate for both the wide and narrow-range functions. In NRC Safety Evaluation Report dated Septemtwr 28, 1990, staff concluded the wide-range instnnnentation provided was acceptable.
In a letter dated March 24, 1992, NRC staff indicated a safety evaluation of the Data Point Library contained in our October 28,1991 submittal would be forthcoming. We request the addition of the four data points and other changes noted above be included in the staff's review and safety evaluation.
l l
LIC\\NRC\\ERDS
\\
t ATTACIIMFNT 2 To Ixtter from C. A. Schrock (WPSC) to Document Control Desk (NRC)
Dated Febnitry 13,1993 ERDS DATA POINT LIBRARY l
LIC\\NRC\\ERDS l
1
_. ~ _. _ _...
_......__,_._m FEB 121993 EPHP 9.5-ORIGINAL FAGE 1 0F 1 ERDS DATA POINT LIBRARY FORM INDEX KEWAUNEE NUCLEAR POWER PLANT FORN LIBRARY SHEET NUMBER POINT ID GENERIC DESCRIPTION REVISION DATE 1
N80200 NUCLEAR INSTRUMENTS, POWER RANGE 04/23/91 2
N70350 NUCLEAR INSTRU, INTERMED. RANGE 04/23/91 3
N80310 NUCLEAR INSTRU, SOURCE RANGE 02/03/93
- 4 L80240 REACTOR VESSEL WATER LEVEL 06/21/91 5
111000 HIGHEST TEMP AT THE CORE EXIT 04/23/91 6
T00200 SATURATION TEMP-HIGHEST CET 04/23/91 7
F80070 REACTOR COOLANT FLOW LOOP A 02/03/93
- 8 F80080 REACTOR COOLANT FLOW LOOP B 02/03/93
- 9 LB0130 STEAM GENERATOR A CATER LEVEL 04/23/91 10 L80140 STEAM GENERATOR B WATER LEVEL 04/23/91 11 P8021G STEAM GENERATOR A PRESSURE 04/23/91 12 P80220 STEAM GENERATOR-B PRESSURE 04/23/91 13 F80090 STM GEN A MAIN FEEDWATER FLOW 06/21/91 14 F80100 STM GEN.B MAIN FEEDWATER FLOW 06/21/91 15 F8003A STM GEN A AUXILIARY FW FLOW 04/23/91 16 F8004A STM GEN B AUXILIARY FW FLOW 04/23/91 l
17 T0419A STM GEN A INLET TEMPERATURE 04/23/91 18 70439A STM GEN B INLET TEMPERATURE 04/23/91 19 T0406A STM GEN A OUTLET TEMPERATURE 04/23/91 20 70426A STM GEN B OUTLET TEMPERATURE 04/23/91 21 P80230 REACTOR COOLANT SYSTEM PRESSURE 04/23/91 22 L80150 PRIMARY SYSTEM' PRESSURIZER LEVEL 06/?1/91 23 F01280 PRIMARY SYSTEM CHAF,71NG FLOW 04/23/91 24 F80010 HIGH PRESS SAFETY INJECTION FLOW 02/03/93
- 25 F80020 HIGH PRESS SAFETY INJECTION FLOW 02/03/93
- 26 F0626A LOW PRESS SAFETY. INJECTION FLOW 07/24/91 27 NOT AVAIL. CONTAINMENT SUMP NARROW RNG LVL 04/23/91 26 L8001A CONTAINMENT SUMP WIDE RNG LVL 04/23/91 29 G00140 RADIOACTIVITY OF RELEASED GASSES 04/23/91 30 G00180 RADICACT. OF RELEASED LIQUIDS 04/23/91 31 000150 CONDENSER AIR EJECTOR RADICACT.
04/23/91 32 G01140.
RADIATION LEVEL IN CONTAINMENT 04/23/91 33 003090 RAD LEVEL OF RCS LETDOWN LINE 04/23/91 34 001020 ETH CEN A STEAM LINE RAD LEVEL 04/23/91 35 G0104Q STM GEN B STEAM LINE RAD LEVEL 04/23/911
'36 G00190 STM GEN BLOWDOWN RAD LENTL 04/23/91' 37 P8004A CONTAINMENT PRESSURE-02/03/93
- 38 T1000A CONTAINMENT TEMPERATURE 02/03/93
- 39 X8001A
_ CONTAINMENT HYDROGEN CONCEN.
04/23/91 40 L8008A BORATED WATER STORAGE TANK LEVEL 02/03/93
- 41 M0001A WIND SPEED AT REACTOR SITE 04/23/91 42 M00020
-WIND DIP.ECTION AT BEACTOR SITE 04/23/91, 43 M0004A AIR STAu!LITY AT REACTOR SITE 04/23/91 l
l I
- INDICATES REVISIONS MADE SINCE 10/28/91 SUBMITTAL.
EPKP 9.5 ERDS FORM INDEI i
a
-,_.a_.
- -=-.
...=
FEB 12 093 EPKP 9.5 Origins 1 Page 1 of 1 ERDS PARAMETERS - DATA POINT LIBRARY KEWAUNEE NUCLEAR POWER PLANT FIELD ITEM LENGTH KNPP ERDS DATA DATE:
(8) 04/23/91 REACTOR UNIT (3)
KW1 DATA FEEDER:
(10)
N/A f
NRC ERDS PARAM:
(12)
NI POWER RNG POINT ID:
(12)
(40)
NI POWER RANGE - SPDS GENERIC /COND DESC:
(32)
NUCLEAR INSTRUMENTS, POWER RANGE ANALOG / DIGITAL:
(1)
A (A, D)
ENGR UNITS /DIO ST:
(12)
PCT ENGR UNITS CONVERS:
(40)
N/A MIN INSTR RANGE:
(10)
O MAX INSTR RANGE:
(10) 120 ZERO PT REF:
(6)
N/A REF PT NOTES:
(40)
N/A PROC OR SENS:
(1)
P (P, S)
NUMBER OF SENSORS:
(3) 4 HOW PROCESSED:
(40)
SPDS-DV SENSOR LOCATIONS:
(40)
CONTAINMENT ALARM / TRIP SET PT:
(40) 25%, 103%, 105%
NI DET PWR SUPPLY N/A TURN ON PWR LVL (15)
INSTR FAIL MODE:
(30)
LOW TEMP COMP FOR DP N/A (Y, N, N/A)
XHTRS:
(3)
LEVEL REF LEG:
(3)
N/A (DRY, WET)
UNIQUE SYS DESC:
(600)
- ALARM / TRIP SET POINTS:
25% LOW RANGE TRIP, 103% OVERPOWER ROD STOP, 105% HI FLUX TRIP.
Form EPHP 9.5-1 l
FEB 121993 EPHP 9.5 Origin 01 Page 1 of 1 ERDS PARAMETARS - DATA POINT LIBRARY F.IWAUNEE NUCLEAR POWER PLANT FIELD ITEM LENGTH KNPF ERDS DATA i
DATE:
(8) 04/23/91 REACTOR UNIT:
(3)
KW1 DATA FEEDER:
(10)
N/A NRC ERDS PARAM:
(12)
NI INTER RNG POINT ID:
(12)
(40)
IR N-35 FLUX CENERIC/COND DESC:
(32)
NUCLEAR INSTRU, INTERMED. MANGE ANALOG / DIGITAL:
(1)
A (A, D)
ENCR UNITS /DIO ST:
(12)
PCT ENGR UNITS CONVERS:
(40)
N/A MIN INSTR RANCE:
(10) 1.0 E-8 HAX INSTR RANGE:
(10) 100 IERO PT REF:
(6)
N/A REF PT NOTES:
(40)
N/A PROC OR SENS:
(1)
S (P, S)
NUMBER OF SENSORS:
(3) 1 HOW PROCESSED:
(40)
N/A SENSOR LOCATIONS:
(40)
CONTAINMENT ALARM / TRIP SET PT:
(40) 15% ROD STOP, 20% REACTOR TRIP NI DET PWR SUPPLY N/A CUTOFF PWR LVL:
(15)
NI DET PWR SUPPLY N/A TURN ON PWR LVL (15)
INSTR FAIL MODE:
(30)
LOW TEMP COMP FOR DP N/A (Y, N, N/A)
XMTRS:
(3)
LEVEL REF LEG (3)
N/A (DRY, WET)
UNIQUE SYS DESC:
(600)
FULL RANGE FISSION CHAMBER.
Form EPKP 9.5-2
FEB 12 G93 EPKP 9.5 OriginOI Page 1 of 1 ERDS PARAMETERS - DATA POINT LIBRARY KEWAUNEE NUCLEAR POWER PLANT w
FIELD ITEM LENGTH KNPP ERDS DATA i
s_
DATE:
(8) 02/03/93 REACTOR UNIT:
(3)
KW1 DATA FEEDER:
(10)
N/A NRC ERDS PARAM:
(12)
HI SOURC RNG P01NT ID:
(12)
(40)
SR N-31 COUNTS GENERIC /COND DESC:
(32)
NUCLEAR INSTRU, SOURCE RANGE ANALOG / DIGITAL:
(1)
A (A, D)
_ ENGR UNITS / DIG ST:
(12)
CPS ENGR UNITS CONVERS:
(40)
N/A MIN INSTR RANGE:
(10) 1.0 E-2 MAX INSTR RANGE:
(10) 1.0 E+4 ZERO PT REF:
(6)
N/A REF PT NOTES:
(40)
N/A 4
PROC OR SENS:
(1)
S (P, S)
NUMBER OF SENSORS:
(3) 1 HOW PROCESSED:
(40)
N/A SENSOR LOCATIONS:
(40)
CONTAINMINT ALARM / TRIP SET JT (40) 1T0*E#5'~ CPS 7 HI"FLUT TRIP NI DET PWR SUPPLY N/A CUTOFF PWR LVL (15)
NI DET PWR SUPPLY N/A TURN ON PWR LVL (15) l INSTR FAIL MODE:
(30)
DOWNSCALE j
TEMP COMP FOR DP N/A (Y, N, N/A)
XHTRS:
(3)
LEVEL REF LEG (3)
N/A (DRY, WET)
UNIQUE SYS DESC:
(600)
SOURCE RANGE INSTRUMENTS ARE ENERGIZED AT ALL POWER LEVELS. FISSION CHAMBERS.
f Form EPMP 9.5-3 l
l l
FEB 121993 EPHP 9.5 Original y
Page 1 of 1 ERDS PARAMETERS - DATA POINT LIBRARY KEWAUNEE NUCLEAR POWER PLANT FIELD ITEM LENGTH KNPP ERDS DATA DATE:
(8) 06/21/91 REACTOR UNIT:
(3)
KW1 DATA FEEDER:
(10)
N/A NRC ERDS PARAM:
(12)
REAC VES LEV POINT ID:
(12)
(40)
REACTOR VESSEL LEVEL AVG GENERIC /COND DESC:
(32)
REACTOR VESSEL WATER LEVEL ANALOG / DIGITAL:
(1)
A (A, D)
ENGR UNITS / DIG ST:
(12)
PCT ENGR UNITS CONVERS:
(40)
N/A MIN INSTR RANCE:
(10) 0 MAX INSTD RANGE:
(10) 200 ZERO PT REF:
(6)
HOTLEG REF PT NOTES:
(40)
N,[A PROC OR SENS:
(1)
P (P, 5)
NUMBER OF SENSORS:
(3) 2 HOW PROCESSED:
(40)
AVG SENSOR LOCATIONS:
(40)
CONTAINMENT ALARM / TRIP SET PT:
(40p N/A NI DET PWR SUPPLY N/A CUTOFF PWR LVL:
(15)
NI DET PWR SUPPLY N/A TURN CN PWR LVL:
(15)
INSTR FAIL MODE:
(30)
LOW TEMP COMP FOR DP N
(Y, H, N/A)
XMTRS:
(3)
LEVEL REF LEG (3)
DRY (DRY, WET)
UNIQUE SYS DESC:
(600)
TOP OF ACTIVE FUEL IS BELOW TME MINIMUM INSTRUMENT RANGE OF 0%.
Form EPMP 9.5-4
FEB 121993
(
EPKP 9.5 OriginOI Page 1 of 1 ERDS PARAMETERS - DATA POINT LIBRARY KEWAUNEE NUCLEAR POWER PLANT FIELD ITEM LENGTH KNPP ERDS DATA
._m DATE:
(8) 04/23/91 REACTOR UNIT:
(3)
KW1 DhTA FEEDER:
(10)
N/A NRC ERDS PARt.Mi (12)
TEMP CORE EX POINT ID:
(12) 111000 PLANT SPEC PT DESC:
(40)
INST VALUE HOT INCORE TC GENERIC /COND DESC:
(32)
HIGHEST TEMP,AT THE CORE EXIT ANALOG / DIGITAL:
(1)
A (A, D)
ENGR UNITS /LIC ST:
(12)
DEGF ENGR UNITS CONVERS:
(40)
N/A HIN INSTR RANGE:
(10)
CRJT*
MAX INSTR RANGE:
(10) 2300 ZERO PT REF:
(6)
N/A REF PT,_ NOTES:
(40)
N/A PROC OR SENS:
(1)
P (P, S)
NUMBER OF SENSORS:
(3) 39 HOW PROCESSED:
(40)
KAX SENSOR LOCATIONS:
(40)
CONTAINMENT ALAPM/ TRIP SET PT:
(40)
NONE NI DET PWR SUPPLY N/A CUTOFF PWR LVL (15)
NI DET PWR SUPPLY N/A TURN ON PWR LVL (15)
INSTR FAIL MODE:
(30)
LOW TEMP COKP FOR DP N/A (Y, N, N/A)
KMTRS:
(3)
LEVEL REF LEG:
(3)
N/A (DRY, WET) i UNIQUE SYS DESC:
(GOO)
- CRJT = COLD REFERENCE JUNCTION TEMPERATURE.
a Foss EPKP-9.5-5 l
i;
/EB 12 tc 3 EPMP 9.5
)
)
Original Page 1 of 1
)
ERDS PARAMETERS'- DATA POINT LIBRARY KZWAUNEE NUCLEAR POWER PLANT i
l FIELD.
ITEM LENGTH KMPP ERDS DATA DATE:
(8) 04/23/91 REACTOR UN.*T:
(3)
F.W1 l
DATA FEEDER (10)
N/A NRC ERDS PARAM:
(12)
SUB MARGIN POINT ID:
(12)
T00200 PLANT SPEC PT DFSC (40)
RX SUBCOOLING-KAX TC GENERIC /COND DESC:
(32)
SATURATION TEMP-HIGHEST CET ANALOC/ DIGITAL:
(1)
A (A, D)
ENGR UNITS / DIG STs (12)
DEGF ENGR UNITS CONVERS:
(40)
N/A MIN INSTR RANGE:
(10)
N/A HAX INSTR RANCE:
(10)
N/A ZERO PT REF:
( 6 ',
N/A REF PT NOTES:
(40)
N/A i
PROC OR SENS:
(1)
P (P, 5)
+
NUMBER OF SENSORS:
(3) 41 HOW PROCESSED:
(40)
CALCULATION - STEAM TABLE CALL SENSOR LOCATIONS:
(40)
CONTAINKENT ALARM / TRIP SET PT:
-(40)
N/A NI DET PWR SUPPLY N/A CUTOFF PWR LVL (15)
NI DET PWR SUPPLY N/A TURN ON PWR LVL:
(15)
INSTR FAIL MODE:
(30)
DEPENDENT UPON INPUT;TC'S-LOW.
TEMP COMP FOR DP N/A (Y, N, N/A)
XMTRS:
(3) l' LEVEL REF LEG (3)
N/A (DRY, WIT) p UNIQUE SYS.DESCi (600)
CALCULATION USES POINT ID I11000 (HIGHEST TEMP AT THE CORE EXIT) AS A TERPERATURE l'
INPUT PLUS WIDE RANGE REACTOR COOLANT-SYSTEM PRESSURE ANp ATMOSPHERIC PRESSURE INPUTS.
Form EPNP 9.5-6
~!
.~.- _,_._...,.,_._. _. _
...m..
kh Original v
Page 1 of 1 ERDS PARAMETERS - DATA POINT LIBRARY KEWAUNEE NUCLEAR POWER PLANT FIELD ITEM LENGTH KNPP ERDS DATA DATE:
(8) 02/03/93 REACTOR UNIT:
(3)
KW1 DATA FEEDER:
(10)
N/A NRC ERDS PARAM:
(12)
CORE FLOW POINT ID:
(12)
(40)
RCLA AVERAGE FLOW (LOOP A)
GENERIC /COND DESC:
(32)
REACTOR COOLANT FLOW LOOP A ANALOG / DIGIT AL:
(1)
A (A, D)
ENGR UNITS /DIO ST:
(12)
PCT ENGR UNITS CONVIRS:
(40)
N/A MIN INSTR RANGE:
(10)
O MAX INSTR RANCE:
(10) 110 ZERO PT REF:
(6)
N/A REF PT NOTES:
(40)
N/A PROC OR SENS:
(1)
P (P, S)
NUMBER OF SENSORS:
(3) 3 HOW PROCESSED:
(40)
AVERAGE SENSOR LOCATIONS:
(40)
CONTAINMENT ALARM / TRIP SET PT:
(40) 90% REACTOR TRIP NI DET PWR SUPPLY N/A CUTOFF PWR LVL (15)
NI DET PWR SUPPLY N/A TURN ON PWR LVL (15)
INSTR FAIL MODE:
(30)
LOW f TEMP COMP FOR DP N
(Y, N, N/A)
XMTRS:
(3)
LEVEL REF LEG (3)
N/A (DRY, WET) i UNIQUE SYS DESC:
(600)
INSTRUMENTS: FT-411, FT-412, FT-413.
100% FLOW = 94792e GPM (NOTE: THIS NUMBER WILL CHANGf ANNUALLY BASED ON S/G TUBE PLUGGING OR SLEEVING PERFORMED.)
Form EPMP 9.5-7
- EB 12 ':c:
EPMP 9.5 Origins 1 Page 1 of 1 ERDS PARAMETERS - DATA POINT LIBRARY KEWAUNEE NUCLEAR POWER PLANT FIELD ITEM LENGTH KNPP ERDS DATA DATE:
(8) 02/03/93 REACTOR UNIT:
(3)
KW1 DATA FEEDER:
(10)
N/A NRC ERDS PARAM:
(12)
CORE FLOW POINT ID:
(12)
(40)
RCLB AVERAGE FLOW (LOOP B)
GENERIC /COND DESC:
(32)
REACTOR COOLANT FLOW LOOP D ANALOG / DIGITAL:
(1; A
(A, D)
ENGR UNITS / DIG ST:
(12)
PCT ENCR UNITS CONVERS:
(40)
N/A MIN INSTR RANGE:
(10) 0 MAX INSTR RANCE:
(10) 110 ZERO PT REF:
(6)
N/A REF PT NOTES:
(40)
N/A PROC OR SENS:
(1)
P (P, S)
NUMBER OF SENSORS:
(3) 3 HOW PROCESSED:
(40)
AVERACE SENSOR LOCATIONS:
(40)
CONTAINMENT ALARM / TRIP SET PT:
(40) 90% REACTOR TRIP NI DET PhR SUPPLY N/A CUTOFF PWR LVL (15)
NI DET PWR SUPPLY N/A TURN ON PWR LVL (15)
INSTR FAIL MODE:
(30)
LOW TEMP COMP FOR DP N
(Y, W, N/A)
XMTRS:
(3)
LEVEL REF LEG (3)
N/A (DRY, WET)
UNIQUE SYS DESC:
(600)
INSTRUMENTS:
FT-414, FT-415, FT-416, 100% FLOW = 95y27Q GPM (NOTE: THIS NUMBER WILL CHANGE ANNUALLY BASED ON S/G TUBE PLUGGING OR SLEEVING PERFORMED.)
l i
Fo rm EPHP 9. 5 - 8 l
FE812 *ag3 EPHP 9.5 Originsi
~
Page 1 of 1 ERDS PARAMETERS - DATA POINT LIBRARY KEWAUNEE NUCLEAR POWER PLANT FIELD ITEM LENGTH KNPP ERDS DATA DATE:
(8) 04/23/91 REACTOR UNIT:
(3)
KW1 DATA FEEDER:
(10)
N/A NRC ERDS PARAM:
(12)
SG LEVEL 1/A POINT ID:
(12)
(40)
S/G A KR LEVEL - SPDS GENERIC /COND DESC:
(32)
STEAM GENERATOR A WATER LEVIL ANALOG / DIGITAL:
(1)
A (A, D)
ENGR UNITS / DIG ST:
(12)
PCT ENGR UNITS CONV4RS:
(40)
N/A MIN INSTR RANGE:
(10)
O MAX INSTR RANGE:
(10) 100 ZERO PT REF:
(6)
UTUBES
_REF PT NOTES:
(40) 0% IS TOP OF S/O UTUBES.
PROC OR SENS:
(1)
P (P, S)
NUMBER OF SENSORS:
(3) 3 HOW PROCESSED:
(40)
SPDS-DV SENSOR LOCATIONS:
(40)
CONTAINMENT ALARH/ TRIP SET PT:
(40)
AMSAC=12%,LO-LO=17%,LO=25.5%*,HI-HI=67%
NI DET PWR SUPPLY N/A CUTOFF PWR LVL (15)
NI DET PWR SUPPLY N/A TURN ON PWR LVL (15)
INSTR FAIL MODE:
(30)
INSTRUMENTS: LOW TEMP COMP FOR DP Y
(Y, N, N/A)
XHTRS:
(3)
LEVEL REF LEG:
(3)
WET (DRY, WET)
UNIQUE SYS DESC:
(600)
INSTRUMENTS:
LT-461, LT-462, LT-463.
HI ALAkM= MAIN OR DYPASS FW FLO'1 CONTROL VALVE FAILS TO OPEN.
- S/G LO LEVEL 25.54 COINCIDENT WITH STEAM FLOW > FEED FIDW CAUSES A REACTOR TRIP.
Form EPHP 9.5-9 9
FE812 eaa EPMP 9.5~
Origin 01 l
Page 1 of 1
~
j ERbS PARAhtTERS - DATA POINT LIBRARY KEWAUNEE NUCLEAR POWER PLANT FIELD ITEM LENGTH KNPP E ADS DATA DATE:
(8) 04/23/91 REACTOR UNIT:
(3)
KW1 DATA FEEDER:
(10)
N/A NRC ERDS PARAM:
(12)
SG LEVEL 2/B POINT ID:
(12)
(40)
S/G B NR LEVEL - SPDS GENERIC /COND DESC:
(32, STEAM GENERATOR B WATER LCVEL ANALOG / DIGITAL:
(1)
A (A, D)
ENGR UNITS /DIO ST:
(12)
PCT ENGR UNITS CONVERS:
(40)
N/A MIN INSTR RANGE:
(10) 0 KAX INSTR RANGE:
(10) 100 ZERO PT REF:
(6)
UTUBES REF PT NOTES:
(40) 0% IS TOP OF S/G TUBES.
PROC OR SENS:
(1)
P (P, S)
NUMBER OF SENSORS:
(3) 3 HOW PROCESSED:
(40)
SPDS-DV SENSOR LOCATIONS:
(40)
CONTAINKENT ALARM / TRIP SET PT:
(40)
AMSAC=12%,LO-LO=17%,LO=25.5%*,HI-HI=67%
NI DET PWR SUPPLY N/A CUTOFF PWR LVL (15)
NI DET PWR SUPPLY N/A TURN ON PWR LVL:
(15)
INSTR FAIL MODE:
(30)
INSTRUMENTS: LOW TEMP COMP FOR DP Y
(Y, N, N/A)
XMTRS:
(3)
LEVEL REF LEG (3)
WET (DRY, WETJ UNIQUE SYS DESC:
(600)
INSTRUMENTS:
LT-471, LT-472, LT-473.
HI ALARM = MAIN OR DYPASS FW FLOW CONTROL VALVE FAILS TO OPEN.
- S/0 LO LEVEL 25.5% COINCIDENT WITH STEAM FLOW > FEED ? LOW CUASES A REACTOR TRIP.
m Form EPKP 9.5-10
FEB 12 G93 EPMP 9.5 Original Page 1 of 1
~
ERDS PARAMETERS - DATA POINT LIBRARY KEWAUNEE NUCLEAR POWER PLANT l
FIELD ITEM LENGTH KNPP ERDS DATA DATE:
(8) 04/23/91 REACTOR UNIT:
(3)
KW1 DATA FEEDER:
(10)
N/A NRC ERDS PARAM:
(12)
SG PRESS 1/A POINT ID:
(12)
(40)
S/G A STM PRESSURE - SPDS GENERIC /COND DESC:
(32)
STEAM CENERATOR A PRESSURE ANALOG / DIGITAL:
(1)
A (A, D)
ENGR UNITS /DIO ST:
(12)
PSIG ENGR UNITS CONVERS:
(40)
N/A MIN INSTR RANCE:
(10) 0 MAX INSTR RANGE:
(10)
- 1400, ZERO PT REF:
(6)
N/A REF PT NOTES:
(40)
N/A PROC OR SENS:
(1)
P (P, 5)
NUMBER OF SENSORS:
(3) 3 HOW PROCESSED:
(40)
SPDS-DV SENSOR LOCATIONS:
(40)
ON 30" MS LINE OUTSIDE CONTAINKENT ALARM / TRIP SET PT:
(40) 500 PSIG LO PRESS SI ACTUATION I
l NI DEI PWR SUPPLY N/A l
CUTOFF PWR LVL:
(15)
NI DET PWR SUPPLY N/A TURN ON PWR LVL:
(15) l INSTR FAIL MODE:
(30)
LOW TEMP COMP FOR DP N/A (Y, N, N/A)
XMTRS:
(3)
LEVEL RLF LEG (3)
N/A (DRY, WET)
UNIQUE SYS DESC:
(600)
INSTRUMENTS PT-468, PT-469, PT-tB2
=
Poru EPMP 9.5-11
.. _ _ _.. _ _.. ~ _. _.... _ _. _ _ _
FEB 12 p.c3 EPKP 9.$*
Original
~
Page 1 of 1 ERDS PARAMETERS - DATA POINT LIBRARY i
KEWAUNEE NUCLEAR POWER PLANT j
FIELD ITEM LENGTH KNPP ERDS uDATA DATE:
(8) 04/23/91 REACTOR UNIT:
(3)
KW1 DATA FEEDERt (10)
N/A NRC ERDS PARAM:
(12)
SG PRESS 2/B POINT ID:
(12)
(40)
S/G B STM PRESSURE - SPDS CENERIC/COND DESC:
(32)
STEAM CENERATOR B PRESSURE ANALOG / DIGITAL:
(1)
A (A, D)
ENCR UNITS /DIO ST:
(12)
PSIG ENGR UNITS CONVERS:
(40)
N/A MIN INSTR RANGE:
(10)
O HAX INSTR RANCE:
(10) 1400 ZERO PT REF:
(6)
N/A RRF PT NOTES:
(40)
N/A PROC OR SENS:
(1)
P (P, S)
NUMBER OF SENSORS:
(3) 3 HOW PROCESSED:
(40)
SPDS-DV SENSOR LOCATIONS:
(40)
ON 30" HS LINE OUTSIDE CONTAINKENT ALARM / TRIP SET PT:
(40) 500 PSIG LO PRESS SI ACTUATION NI DET PWR SUPPLY N/A CUTOFF PRR LVL:
(15)
NI DET PWR SUPPLY N/A TURN ON PWR LYL (15)
_ INSTR FAIL MODE:
(30)
LOW TEMP COMP FOR DP N/A (Y, N, N/A) i XMTRS:
(3)
LEVEL REF LEG (3)
N/A (DRY, WET)
UNIQUE SYS DESC (600)
INSTRUMENTS:
PT-478, PT-479, PT_483.
Form EPMP 9.5-12
=
,--vyv
.-e,
E 5 3 I 2 ". 5 '
EPKP 9 Original
~
Page 1 of 1 E RO $ PARAKETIRS - DATA POINT LIBRARY KN AUNER NUCLEAR POWER PLANT FIELD ITEM LENGTH KNPP ERDS DATA OATE:
(8) 06/21/91 REACTOR UNfT (3)
KW1 DATA FEEDER:
(10)
N/A 4
NRC ERDS PARAM:
(12) kN FD FL 1/A POINT ID:
(12)
(40)
S/G A FW FLOW - AVG GENERIC /COND DESC:
(32)
STM GEN A HAIN FEEDWATER FLOW ANALOG / DIGITAL:
(1)
A (A, D)
ENGk UNITS / DIG ST:
(12)
KLBN ENGR UNITS CONVERS:
(40)
N/A HIN INSTR RANGE:
(10) 0 KAX INSTR RANGE:
(10) 4470 EERO PT RIF:
(6)
N/A REF PT NOTES: -
(40)
N/A PROC OR SENS:
(1)
P (P, S)
NUMBER OF SENSORS:
(3) 2 HOW PROCESSED:
(40)
AVERAGE SENSOR LOCATIONS:
(40)
ON FEEDWATER LINE OUTSIDE CONTAINMENT ALARM / TRIP SET PT:
(40)
SF>FF COINC. WITH 25.5% S/G LVL PX TRIP
HI DET PWR SUPPLY N/A TURN ON PWR LVL (15)
INSTR FAIL MODE:
(30)
LOW OR HIGH TEMP COMP FOR DP N
(Y, N, N/A)
XHTRS:
(3)
LEVEL REF LEG (3)
WET (DRY, WET)
UNIQUE SYS DESC:
(600)
- ALARM / TRIP SET POINT:
SF>FF 0.87 X 1.0 E+6 LBM OOINCIDENT WITH 25.5% S/G LEVEL; REACTOR TRIP.
STEAM FIOW > FEED FLOW ALARM.
FEED FLOW > STIAM FLOW ALARM.
INSTRUMENTS:
FT-466 AND FT-467 Form EPMP 9.5-13 ee
.v%--
s-.---
w
,w
..e,,-g.--%%
---..w,
-.m v
g
FE912":a EPKP 9.5 Original Page 1 of 1 ERDS PARAMETERS - DATA POINT LIBRARY KEWAUNEE NUCLEAR POWER PLANT FIELD ITEM LENGTH KNPP ERDS DATA DATE:
(8) 04/23/91 REACTOR UNIT:
(3)
KW1 DATA FEEDER:
(10)
N/A NRC ERDS PARAM:
(12)
AX FD FL 1/A POINT ID:
(12)
(40)
AUX FEED WTR HDR 1A FLOW GENERIC /COND DESC:
(32)
STM GEN A AUXILIARY TW FLOW ANALJG/ DIGITAL:
(1)
A (A, D)
ENGR UNITS /DIO ST:
(12)
GPM ENGR UNITS CONVERS:
(40) 0 TO 300" WATER = 0 TO 500 GPM MIN INSTR RANGE:
(10)
O MAX INSTR RANG _E (10) 500 ZERO PT REF:
(6)
N/A REF FF NOTES:
(40)
N/A PROC OR SENS:
(1)
S (P, S)
HUMBER OF SENSORS:
(3) 1 HOW PROCESSED:
(40)
N/A SENSOR LOCATIONS:
(40)
AUX BLDG, APPROX 50 FT DOWNSTRM OF PUMPS ALARM / TRIP SET PT:
(40)
N/A NI DET PWR SUPPLY N/A CUTOFF PWR LVL (15)
NI DET PWR SUPPLY N/A TURN ON PWR LVL (15)
INSTR FAIL MODE (30)
LOW TEMP COMP FOR DP N
(Y, N, N/A)
IMTRS:
(3)
LEVEL REF LEG (3)
N/A (DRY, WET)
UNIQUE SYS DESC:
(600)
INSTRUMENT FT-2301D. THE AFW SYSTEM HAS 2 MOTOR DRIVEN PUMPS AND ONE STEAM TURBINE DRIVEN PURP.
EACH PUMP IS RATED AT 240 GPM.
TWO CLNDENSATE STORAGE TANKS, 75,000 GALLONS EACH, SUPPLY WATER TO THE AUX FEEDWATER PUKPS.
Form EPHP 9.5-15 I
l
FE812 ngy EPMP 9.5 Origins 1 Page 1 of 1 ERDS PAPJMETERS - CATA POINT LIBPARY FEWAUNEE NUCLEAR POWER PLANT l
i FIELD KNPP ERDS DATA ITEM LENGTH DATE:
(8) 04/23/91 REACTOR UNIT:
(3)
KW1 DATA FEEDER:
(10)
N/A NRC ERDS PARAM:
(12)
AX FD FL 2/B POINT ID:
(12)
(40)
AUE FEED WTR HDR 1B FLOW GENERIC /COND DESC:
(32)
STM GEN B A"XILIARY FW FLOW ANALOG / DIGITAL:
(1)
A (A, D)
ENGR UNITS / DIG ST:
(12)
GPM ENGR UNITS CONVERS:
(40) 0 TO 380* WATER = 0 TO 500 GPM MIN INSTR RANGr4 (10)_
0 MAX INSTR RANGE:
(10) 500 IERO PT REF:
(6)
N/A RIF PT NOTES:
(40)
N/A PROC OR SENS:
(1)
S
( P, 5)
NUMBER OF SENSORS:
(3) 1 HOW PROCESSED:
(40)
N/A SENSOR LOCATIONS:
(40)
AUE BLDG, APPROX 50 FT DOWNSTRM OF PUMPS ALARM / TRIP SET PT:
(40)
N/A NI DET PWR SUPPLY N/A CUTOFF PWR LVL (15)
NI DET PWR SUPPLY N/A TURN ON PWR LVL (15)
INSTR FAIL MODE:
(30)
LOW TEMP COMP FOR DP N
(Y, N, N/A).
l XMTRS:
(3)
_ LEVEL REF LEG:
(3)
N/A (DRY, WET)
UNIQUE SYb DESC:
(600)
INSTRUMENT FT-23012. THE AFW SYSTEM HAS 2 MOTOR DRIVEN PUMPS AND ONE STEAM TURBINE DRIVEN PUMP.
EACH PUMP IS RATED AT 240 GPM.
TWO OONDENSATh STORAGE TANKSi 75,000 l
GALLONS SACH, SUPPLY WATER TO THE AUX FEEDWATla PUMPS.
Form EPMP 9.5-16 1
1
I[.9 I 2 .11 EPHP 9.5 Originni Page 1 of 1 ERDS PARAMETERS - DATA POINT LIBRARY KEWAUNEE NUCLEAR POWER PLANT FIELD ITEM LENGTN KNPP IRDS DATA DATE:
(8) 04/23/91 REACTOR UNIT (3)
KW1 DATA FEEDER:
(10)
N/A NRC ERDS PARAM (12)
HL TEMP 1/A POINT ID:
(12)
T0419A PLANT SPEC PT DESCt (40)
RCLA HOT LEQ (WR) TEMP GENERIC /COND DESC:
(32)
STM GEN A INLET TE.MPERATURE ANALOG / DIGITALS (1)
A (A: D)
ENGR UNITS / DIG STt (12)
DEGF ENGR UNITS CONVERS:
(40)
N/A I
MIN INSTR RANGE:
(10) 50 HAX INSTR RANGE:
(10) 650 ZERO PT REF:
(6)
N/A REF PT NOTES:
(40)
N/A PROC OR SENS (1)
S (P, 5)
NUMBER OF SENSORS:
(3) 1 HOW PROCESSED:
(40)
N/A SENSOR LOCATIONS:
(40)
ON REACTOR COOLANT LOOP TO S/G 1A ALARh/ TRIP SET PT:
(40)
N/A NI DET PWR SUPPLY N/A CUTOFF PWR LVL (15)
NI DET PRR SUPPLY N/A TURN ON PWR LVL:
(15)
INSTR FAIL MODE:
(30)
HIGH TEMP COMP FOR DP N/A (Y, N, N/A)
XHTRS:
(3)
LEVEL REF LEOS (3)
N/A (DRY, WET)
UNIQUE SYS DESC:
(600)
MAXIMUM DESIGN TZMPERATURE IS 650 DEGREES F.
Form EPMP 9.5-17
- ~-
7s3127:3 EPKP $.$
Original Page 1 of 1 j
i ERDS PARAKETERS - DATA POINT LIBRARY KEWAUNEE NUCLEAR POWER PLANT l
FIELD ITEN LENGTH KNPP ERDS DATA DATE:
(8) 04/23/91 REACTOR UNIT:
(3)
KW1 l
DATA FEEDER:
(10)
N/A NRC ERDS PARAM:
(12)
KL TEMP 2/B POINT ID:
(12)
T0439A PLANT SPEC PT DESC (40)
RCLB NOT LEG (WR) TEMP CENERIC/COND DESCs (32)
STM GEN B IRLET TEMPERATURE ANALOG / DIGITAL:
(1)
A (A, D)
ENCR UNITS / DIG ST:
(12)
DEGF ENGR UNITS CONVERS:
(40)
N/A MIN INSTR RANGE:
(10) 50 MAX INSTR RANGE:
(10) 650 IERO PT REF:
(6)
N/A REF PT NOTES:
(40)
N/A PROC OR SENS:
(1)
S (P, 5)
NUMBER OF SENSORS:
(3) 1 HOW PROCESSED:
(40)
N/A SENSOR LOCATIONS (40)
ON REACTOR COOLANT LOOP TO S/O IB ALARM / TRIP SET PT:
(40)
N/A NI DET PWR SUPPLY N/A CUTOFF PWR LVL:
(15)
NI DET PWR SUPPLY N/A TURN ON PWR LVL:
(15)
INSTR FAIL MODE:
(30)
HIGH N/A (Y, N, N/A)
TEMP COMP FOR DP
.(3)
XHTRS:
LEVEL REF LEGt (3)
N/A (DRY, WET)
UNIQUE SYS DESC:
(600)
MAXIMUM DESIGN TEMPERATURE IS 650 DEGREES F.
Form EPMP 9.5-18 l
L 1
l l
. _ -... ~
FEB 12 e-o EPKP 9.5 Original Page 1 of 1 ERDS PARAKETERS - DATA POINT LIBRARY KEWAUNEE NUCLEAR POWER PLANT FIELD ITEM LENGTH KNPP ERDS DATA DATE:
(8) 04/23/91 REACTOR UNIT (3)
KW1 DATA FEEDER:
(10)
N/A NRC ERDS PARAM:
(12)
CL TEMP 1/A POINT ID:
(12)
(40)
RCLA COLD LEG (WR) TEMP GENERIC /COND DESC:
(32)
STM GEN A OUTLET TEMPERATURE ANALOG / DIGITAL:
(1)
A (A, D)
ENGR UNITS / DIG ST:
(12)
DEGF ENGR UNITS CONVERS:
(40)
N/A MIN INSTR RANGE:
(10) 50 MAX INSTR RANGE +
(10) 650 ZERO PT REF:
(6)
N/A REF PT NOTES:
(40)
N/A PROC OR SENS:
(1)
S (P, S)
NUMBER OF SENSORS:
(3) 1 HOW PROCESSED:
(40)
N/A
, SENSOR LOCATIONS:
(40)
ON RX COOLANT PUMP 1A DISCHARGE PIPING ALARH/ TRIP SET PT:
(40)
N/A NI DET PWR SUPPLY N/A CUTOFF PWR LVL:
(15)
HI DET PWR SUPPLY N/A TURN ON PWR LVL (15)
INSTR FAIL MODE:
(30)
HIGH TEMP COMP roR DP N/A (Y, N, N/A)
I XMTRS:
(3)
LEVTL REF LEG (3)
N/A (DRY, WET)
UNIQUE SYS DESC:
(600)
KAXINUM DESIGN TEMPERATURE IS 650 DEGREES i
r.
i Form EPHP 9.5-19
.w.-
v.
.c_
,.,_._r
,y..
f 5 3 1 2 '.'5
'.?
EPMP 9 Original Page 1 of 1 ERDS PARATETERS - DATA POINT LIBRARY KEWAUNEE NUCLEAR POWER PLANT FIELD ITEM LENGTH KNPP IRDS DATA DATE:
(8) 04/23/91 REACTOR UNaft (3)
KW1 DATA FEEDERS (10)
N/A NRC ERDS FARAM:
(12)
CL TEMP 2/8 POINT ID:
(12)
T0426A PLANT SPEC PT DESCt (40)
RCLB COLD LEQ (RR) TEMP GENERIC /COND DESC (32)
STM GEN B OUTLET TEMPERATURE ANALOC/ DIGITAL:
(1)
A (A, D)
ENGR UNITS / DIG STt (12)
DEOF ENGR UNITS CONVERS:
(40)
N/A MIN INSTR RANGE (10) 50 MAX INSTR RANGE:
(10) 650 EERO PT REF:
(6)
N/A REF PT NOTES:
(40)
N/A PROC OR SENS:
(1) 5 (P, S)
NUMBER OF SENSORS:
(3) 1 HOW PROCESSED:
(40)
N/A SENSOR LOCATIONS:
(40)
ON RX COOLANT PUMP 1B DISCHARGE PIPING ALARH/ TRIP SET PT:
(40)
N/A NI DET PWR SUPPLY N/A CflTOFF PWR LVL (15)
NI DET PWR SUPPLY N/A TURN ON PWR LVLs (15)
INSTR FAIL NODE (30)
HIGH TEMP COMP POR DP N/A (Y, N, N/A)
XHTRS:
(3)
LEVEL REF LEGS (3)
N/A (DRY, WIT)
UNIQUE SYS DESC:
(600)
MAXIMUM DESIGN TEMPERATURE IS 650 DEGREES r.
Form EPNP 9.5-20
l FE312 993 E7MP 9.5 Original Page 1 of 1 ERDS PARAMETERS - DATA POINT LIBRARY KEWAUNEF NUCLEAR POWER PLANT FIELD ITEM LENGTH KNPP ERDS DATA DATE:
(8) 04/IJ/91 REACTOR UNIT:
(3)
KW1 DATA FEEDER:
(10)
N/A NRC ERDS PARAM:
(12)
RCS PRESSURE POINT ID:
(12)
(40)
RCS PRESSURE ~ SPDS GENERIC /COND DESC:
(32)
REACTOR COOLANT SYSTEM PRESSURE ANALOG / DIGITAL:
(1)
A (A, D)
ENGR UNITS / DIG ST:
(12)
PSIG ENGR UNITS CONVERS:
(40)
N/A HIN INSTR RANCE:
(10) 0 KAX INSTR RANGE:
(10) 3000 ZERO PT REF:
(6)
N/A REF PT NOTES:
(40)
N/A PROC OR SENS:
(1)
P (P, S)
NUMBER OF SENSCAS:
(3) 5 HOW PROCESSED:
(40)
SPDS-DV SENSOR LOCATIONS (40)
ON PRESSURIZER ALARM / TRIP SET PT:
(40) 1823 PSIG, 1904 PSIC, 2377 PSIG
- NI DET PWR SUPPLY.
N/A CUTOFF PWR LVL (15)
NI DET PWR SUPPLY N/A TURN ON PWR LVL (15)
INSTR FAIL MODE:
(30)
LOW TEMP COKP FOR DP N/A (Y, N, N/h)
XMTRS:
(3)
LEVEL REF LEG (3)
WET (DRY, WET)
UNIQUE SYS DESC:
(600)
NORMAL RCS PRESOURE IS 2235 PSIG.
Form EPMP 9.5-21
g1f 9
' *EPKP'9.'5 Original Page 1 of 1 ERDS PARAMETERS DATA POINT LIBRARY KEWAUNEE NUCLEAR POWER PLANT FIELD ITEM LENGTH KNPP ERDS DATA DATE:
(8) 06/21/91 REACTOR UNIT (3)
KW1 DATA FEEDER:
(10)
N/A NRC ERDS PARAM:
(12)
PRER LEVEL POINT ID:
(12)
L80150 PLANT EPEC PT DESC:
(40)
PRESSURIZER LEVEL - SPDS GENERIC /COND DESC:
(32)
PRIMARY SYSTEM PRESSURIZER LEVEL ANALOG / DIGITAL:
(1)
A (A, D)
ENGR UNITS / DIG ST:
(12)
PCT ENGR UNITS CONVERS:
(40)
N/A MIN INSTR RANGE:
(10)
O MAX INSTR RANGE:
(10) 100 ZERO PT REF:
(6)
BOTTOM REF PT NOTES:
(40)
ZERO = BOTTOM OF PRESSURIZER PROC OR SENS:
(1)
P (P, S)
NUMBER OF SENSORS:
(3) 3 HOW PROCESSED:
(40)
SPDS-DV SENSOR LOCATIONS:
(40)
TOP AND BOTTOM OF PRESSURIZER ALARM / TRIP SET PT:
(40) 18.3%, 55%, 85%
NI DET PWR SUPPLY N/A TURN ON PWR LVL (15)
INSTR FAIL MODE:
(30)
LOW TEMP COMP FOR DP N
(Y, N, N/A)
XHTRS:
(3)
LEVEL REF LEOS (3)
WET (DRY, WET)
UNIQUE SYS DESC:
(600)
INSTRUMENTS:
LT-426, LT-427, LT-428
- ALARM / TRIP SETPOINTS:
18.3% = LO ALARM, 55% = HI ALARM, 85% = HI-HI REACTOR TRIP.
TOP OF HEATER BUNDLE, LEVEL = APPROX. 17%.
Form EPMP 9.5-2 2
. ~. __ _
((3 $ 2 EPHP 9.5 Original Page 1 of 1 ERDS PARAMETERS - DATA POINT LIBRARY KEWAUNEE NUCLEAR POWER PLANT FIELD ITEM LENGTH KNPP ERDS DATA DATE:
(8) 04/23/91 REACTOR UNIT (3)
KW1 DATA FEEDER:
(10)
N/A NRC ERDS PARAM:
(12)
RCS CHG/MU POINT ID:
(12)
(40)
CHG PUKP DISCH HDR' FLOW GENLAIC/COND DESC:
(32)
PRIKARY SYSTEM CHARGING FLOW ANALOG / DIGITAL:
(1)
A (A, D)
ENGR UNITS / DIG ST:
(12)
GPM ENGR UNITS CONVERS:
(40)
N/A MIN INSTR RANGE:
(10) 0 KAX INSTR RANGE:
(10) 110 ZERO PT REF:
(6)
N/A REF PT NOTES:
(40)
N/A PROC OR SENS:
(1)
S S'
NUMBER OF SENSORS:
(3) 1 HOW PROCESSED:
(40)
N/A SENSOR LOCATIONS:
(40)
ON 2" DIAM. HEADER AT PUMPS' DISCHARGE ALARH/ TRIP SET PT:
(40)
N/A NI DET PWR SUPPLY N/A CUTOFF PWR LVL (15)
NI DET PWR SUPPLY N/A TURN ON PWR LVL:
(15)
INSTR FAIL MODE:
(30)
LOW TEMP COMP 1 %? DP H
(Y, N, N/A)
XMTRS:
(3)
LEVEL REF LEG (3)
N/A (DRY, WET)
UNIQUE SYS DESC:
(600)
INSTRUMENT FT-128.
THREE CHARGING PUMPS.
EACH PUMP HAS A DESIGN FLOWRATE OF 60.5 GPM (MAE.) AND DISCHARGE PRESSURE OF 3000 PSIO.
PUMPS 1A AND 1B
-AC INDUCTION HOTOR.
PUMP 1C - DC MOTOR SUPPLIED BY AC POWER.
NORMAL CHARGING FLOW IS 30-40 GPM.
Fo rm EPHP 9. 5-2 3 -
,n.
.,r.
F ' 1 @2 ~Y.
EP Original Page 1 of 1 ERDS PARAMETERS - DATA POINT LIBRARY KEWAUNEE NUCLEAR POWER PLANT FIELD ITEM LENGTH FJIPP ERDS DATA DATE:
(8) 02/03/93 l 9EACTOR UNIT:
(3)
KW1 J A FEEDER:
(10)
N/A NRC RRDS PARAM:
(12)
HPSI FLOW POINT ID:
(12)
(40)
SI? PUMP T DI5LT FThW
, GENERIC /COND DESC:
(32)
HIGH PRESS SAFETY INJECTION FLOW ANAI4G/ DIGITAL:
(1)
_A'T( A',* DV i
ENGR UNITS /DIC ST:
(12)
GPW
~
ENGR UNITS CONVERS:
(40)
N/A p
HIN INSTR RANGE:
(10)
O 4
MAX INSTR RANGE:
(10) 505 ZERO PT REF:
(6)
N/A SEF PT NOTES:
(40)
N/A PROC OR SEN$a 11) f"(P 7Tf NUMBER OF SENSORS (3) 1 HOW PROCESSEJ=
f40)
Hf,A SENSOR *OCATIONS:
(40L,0W 7 3 " F DIAM?fWJLDKf AT'1PURP
- S ^ D:8C11ARGE ALARH/TRif SLT PT:
(40)
N/A NI DET PWR SUPPLY
)f/Jj CUTOFF PWR LVL (15)
~
NI DET PWR SUPPLY If[A TURN ON PWR LVL (11)
INSTR FAIL HOLE:
(30) thet TEMP COMP FOR DP M ] Yj{My N/Af XMTRS:
(3)
_ LEVEL REF LEG:
(3)
N/AT(URT7 fit 3Ty UNIQUE SYS DESC:
(600)
' INSTRUMENT $iW PTa925 Porm EPMP 9.5-14
_ CCQ 12 ' o i-~
w EPMP 9.5 Original Page 1 of 1 ERDS PARAMETERS - DATA POINT LIBRARY KEWAUNEE NUCLEAR POWER PLANT FIELD ITEM LENGTH KNPF ERDS DATA.
DATE:
(8) 02/03/93 REACTOR UNIT:
(3)
KW1 DATA FEEDER:
(10)
N/A NRC ERDS PARAM:
(12)
HPSI FLOW POINT ID:
(12)
(40)
SI" PUMP'R!DISCR2 FLOW GENERIC /COND DESC:
(32)
HIGH PRESS SAFETY INJECTION FLOW ANALOG / DIGITAL:
(1)
A l A'i DY
, p ENGR UNITS / DIG ST:
(12)
GPM
,j;,
ENGR UNITS CONVERS:
(40)
N/A MIN INSTR RANGE:
(10)
O MAX INSTR RANGE:
(10) 250 ZERO PT REF:
(6)
N/A REF PT NOTES:
(40)
N/A PROC OR SENS:
(1)
T'[(PP"ST NUMBER OF SENSORS:
(3)
HOW PROCESSED:
(40)
N/n OW 3*iD71dH READER'ATTPUMP5MDISCH E
SENSOR LOCATIONS:
(40)
ALARM / TRIP SET PT:
(40)
N/A NI DET PWR SUPPLY N[j CUTOFF PWR LVL (15)
NI DET PWR OUPPLY N/"A TURN ON PWR LVL (15)
INSTR FAIL MODE:
(30)
TEMP COMP FOR DP Hjl($'iNEN/A]
XMTRS:
(3)
LEVEL REF LEG:
.. (3)
MfF(*TRT7indf)
UNIQUE SYS DE".C:
(600)
INSTRUMENTiiPTfFt4924 Foran EPMP 9.5-25
F 'APkP2 v;sg Crigin 1 Paga 1 of 1 ERDS PARAMETERS - DATA POINT LIBFARY TEWAUNEE NUCLEAR POWER PLANT FIELD' ITEM LEAGTH KNPP ERDS DATA DATE:
(0) 07/24/91 REACTOR UNIT (3)
KW1
._ DATA FEEDER:
(10)
N/A NRC ERDS PARAM:
(12)
(12)
(40)
LO HEAD TRN A RNR TO RCS CENERIC/COND DESC:
(32)
LOW PRESS SAFETY INJECTION FLOW (1)
A (A, D)
ANALOG / DIGITAL:
ENGR UNITS / DIG ST:
(12)
CPM ENGR UNITS CONVERS:
(40)
N/A MIN INSTR RANGE:
(10)
O MAX INSTR RANGE:
(10) 6000 ZERO PT REF:
(6)
N/A REF PT NOTES:
(40)
N/k PROC OR SENS:
(1)
S (P, S)
NUMBER OF SENSORS:
(3) 1 HOW PROCESSED:
(40)
N/A SENSOR LOCATIONS:
(40)
OUTSIDE CNTMT, ON DSCHG OF RHR HTEXCH 1A ALARM / TRIP SET PT:
(40)
N/A NI DET PWR SUPPLY N/A CUTOFF PWR LVL:
(15)
~
NI DET PWR SUPPLY N/A TURN ON PWR LVL:
(15)
INSTR FAIL MODE:
(30)
Ia*1 TEMP COMP FOK DP N/A (Y, N, N/A)
XHTRS:
(3)
LEVEL REF LEG (3)
N/A (DRY, WET)
UNIQUE SYS DESC:
(600)
INSTRUMENT FT-626.
THIS INSTRUPIENT MEASURES-FLOW ENTERING RCS LOOP B COLD LEG DURING NORMAL COOLDOWN. RHR FLOW COULD ALSO BE DIVERTED TO REACTOR VESSEL INJE 7 ION DURING ACCIDENT CONDITIONS IN WHICH CASE FT-626 WOULD INDICATE TRAIN A LPSI FLOW, HOWEVER, TRAIN B LPSI' FLOW WOULD NOT BE MEASURED BY THIS FLOW I
TRANSMITTER.
(TRAIN B LPSI FLOW TRANSMITTER FT-928 IS NOT AVAILABLE ON THE PL _ ANT COMPUTER.)
Fo rm. EPHP 9. 5-2 6
I~id i / F 0 e,
a EPHP 9.5 Original Page 1 of 1 ERDS PARAMETERS - DATA POINT LIBRARY F2WAUNEE NUCL2AR POWER PLANT FIELD ITEF LENGTH KNPP ERDS DATA DATE:
(S) 04/23/91 REACTOR UNIT:
(3)
KW1 DATA FEEDER:
(10)
N/A NRC ERDS PARAM:
(12)
CTMNT SMP NR POINT ID:
(12)
NOT AVAIL.
(40)
GENERIC /COND DESC:
(32)
CONTAINMENT SUMP NARROW RNG LVL ANALOG / DIGITAL:
(1)
ENGR UNITS / DIG ST:
(12)
ENGR UNITS CONVERS:
(40)
MIN INSTR RANGE:
(10)
MAX INSTR RANCE:
(10)
ZERO PT REF:
(6)
REF PT NOTES:
(40)
PROC OR SENS:
(1)
NUMBER OF,.ENSORS:
(3)
HOW PROCESSED:
(40)
SENSOR LOCATIONS:
(40)
A?. ARM / TRIP SET PT:
(40)
NI DET PWR SUPPLY CUTOFF PWR LVL (15)
NI DET PWR SUPPLY TURN ON PWR LVL (15)
INSTR FAIL MODE:
(30)
TEMP COMP FOR C?
XHTRS:
(3)
LEVEL REF LEG (3)
UNIQ'IE SYS DESC:
(6CO)
Form E2MP 9.5-27
-,, 2,,. I EPMP 9.$
Original Page 1 of 1 FRDS PARAKETERS - DATA POINT LIBRARY KEWAUNEE NUCLEAR POWER !?LANT FIELD ITEM LENGTH KNPP ERDS DATA l
.a DATE:
(8) 04/23/91 REACTOR UNIT:
(3)
KW1 DATA FEEDER:
(10)
N/A NRC ERDS PARAM:
(12)
CTMNT SKP WR POINT ID:
(12)
(40)
CNTMT WIDE RANGN LEVEL A GENERIC /COND DESC:
(32)
CONTAINMENT SUMP WIDE RNG LVL ANALOG / DIGITAL:
(1)
A (A, D)
ENGR UNITS /DIO ST (12)
FEET ENGR UNITS CONVERS4 (40)
N/A MIN INSTR RANGE:
(10) 0 MAX INSTR RANGE:
(10) 22 ZERO PT REF:
(6) 592FT.
REF PT NOTES:
(40)
EASEKENT OF CONTAI.NMENT PROC OR SENS:
l (1)
S (P, S)
NUMBER OF SENSORS:
(3) 1 HOW PROCESSED:
(40)
N/A SENSOR LOCATIONS:
(40)
OONTAINMENT 592 FT LEVEL ALARM / TRIP SET PT:
(40) tv/A NI DET PWR SUPPLY N/A CUTOFF PWR LVL:
115)
NI DF.T PWR SUPPLY N/A TURN ON PWR LVL:
(15)
INSTR FAIL. ODE:
(30)
LOW TEMP COMP FOR DP N/A (Y, N, N/A)
XMTRS:
(3)
LEVEL REF LEC:
(3)
N/A (DRY, WET)
UNIQUE SYS DESC:
(600)
INSTRUMENT LT-24070.
- ZERO POINT
REFERENCE:
ELEVATION 592 FT.
Fo rm EPHP 9,5-2 8
[$ 9 I 2 f 3?.0
-l EPHP 9.5 Original Page 1 of 1 E RDS PARAMETERS - DATA POINT LIBRARY j
KEWAUNEE NUCLEAR POWER PLANT l
1 FIELD ITEM LENGTH--
-KNPP ERDS DATA--
DATE:
(8) 04/23/91 REACTOR UNIT:
(3)
KW1 DATA FEEDER:
(10)
N/A NRC ERDS PARAM:
(12)
EFF GAS RAD POINT ID:
(12)
(40)
AUX BLDG VENT HONITOR GENERIC /COND DESC:
(32)
RADIOACTIVITY OF RELEASED GASSES ANALOG / DIGITAL:
(1)
A (A, D)
ENGR UNITS / DIG ST:
(12)
CPM ENGR UNITS CONVERS:
(40)
N/A MIN INSTR RANCE:
(10) 1.0 E+1 MAX INSTR RANGE:
(10) 1.0 E+6 ZERO PT REF:
(6)
N/A REF PT NOTES:
(40)
N/A i
PROC OR SENS:
(1)
S (P, 0)
(TUMBER OP SENSORS:
(3) 1 HOW PROCESSED:
(40)
N/A SENSOR LOCATIONS:
(40)
AUX BLDG VENT STACK ALARM / TRIP SET PT:
(40) 9.0 E+4 CPM l
NI DET PWR SUPPLY N/A CUTOFF PWR LVL:
(15) l I
NI DET PWR SUPPLY N/A TURN ON PWR LVL:
(15)
INSTR FAIL MODE:
(30)
LOW TEMP COMP FOR DP N/A (Y, N, N/A) l
__ XMTRS:
i3)
,_t LEVEL REF LEG (3)
N/A (DRY, WET)
UNIQUE SYS DESC:
(600)
RAD MONITOR R-14, AUX BLDG VENT MONITOR B, CONSISTS OF 4 PA.6 L GM TUBES.
R-14 PROVIDES AUTOMATIC INITIATION OF THE FOLLOWING ESF FUNCTION: ISOLATE NORMAL l
VENT EXHAUST AND START AUXILIARY BUILDING ZONE SV (SPECIAL VENTILATION).
Fcru EPHP 9.5-29
~_ -. --.
i :,6 l l-n*J 4-EPMP 9.5 Original Page 1 cf 1
~
ERDS PARAMETERS - DATA POINT LIBRARY KEWAUNEE NUCLEAR POWER PLANT FIELD-ITEM LENGTH-KNFP ERDS DATA' DATE:
(8) 04/23/91 b
REACTOR UNIT:
(3)
KW1 DATA FEEDER:
(10)
N/A NRC ERDS PARAM:
(12)
EFF LIQ RAD POINT ID:
(22)
(40)
WASTE DISP LIQ EFFLUENT GENERIC /COND DESC:
(32)
-RADICACT. OF RELEASED LIQUIDS ANALOG / DIGITAL:
(1)
A (A, D)
ENGR UNITS /DIO ST:
(12)
CPN ENGR UNITS CONVERS:
(40)
N/A MIN INSTR RANGE:
(10) 1.0 E+1 MAX INSTR RANGE:
(10) 1.0 E+6 ZERO PT REF:
(6)
N/A REF PT NOTES:
(40)
N/A PROC OR SENS:
(1)
S (P, S) f ~
NUMBER OF SENSC!tS (3) 1 HOW PROCESSED:
(40)
N/A S2NSOR LOCATIONS:
(40)
DISCNUtG3 OF WA. ATE CONDENSATE PUMPS ALARM / TRIP SET PT:
(40) 5.0 E+4' CPM I
l NI DET PWR SUPPLY N/A
(
CUTOFF PWR LVLs (15) i NI DET PWR SUPPLY N/A e
(
TURN ON PWR LVL (15) l INSTR FAIL MODE:
(30)-
-LCW TEMP COMP FOR DP N/A (Y, N, N/A)
XMTRS:
(3)
LEVEL REF LEG (3).
N/A (DRY, PET)
UNIQtTE SYS DESC:
(600)
RAD MONITOR R-18, WASTE DISPOSAL SYSTEM LIQUID RFFLUENT MONITOR - CONSISTS OF A NAI. SCINT. CO'JNTER AND SAMPLE VOLUME CHAMBER ASSEMBLY.
INI?IATES AUTOMATIC CLOSURE OF VALVE - WD-19 TO PREVLIT FURTHER -
RELEASE.
i-Form EPMP 9.5-30 l-I h
7 1-.
EPMP 9.5 Originci Page 1 of 1 ERDS PARAMETERS - DATA POINT LIBRARY F.EWAUNEE NUCLEAR POWER PLANT f
FIELD ITEM LENGTH KNPP ERDS DATA 3-DATE:
(8) 04/23/91 REACTOR UNIT (3)
KW1 DATA FEEDER:
(10)
N/A NRC ERDS PARAM:
(12)
COND A/E RAD PDINT ID:
(12)
(40)
CDSP AIR EJECTOR EIHAUST GENERIC /COND DESC:
(32)
CONDENSEP AIR EJECTOR RADIOACT.
_ ANALOG /Dy ITAL:
(1)
A (A, D)
ENGR UNITS /DIC ST:
(12)
CPM ENGR UNITS CONVERS:
(40)
N/A MIN INSTR RANCE:
(10) 1.0 E+1 MAX INSTR RANGE:
(10)
. 0 E+6 ZERO PT REF:
(6) d/A REF PT NOTES:
(40)
N/A PROC OR SENS:
(1)
S (P, S)
NUMBER OF SENSORS:
(3) 1 HOW PROCESSED:
(40)
N/A SENSOR LOCATIONS:
(40)
IN CONDENSER AIR EJECTOR EXHAUST HEADEC ALARM / TRIP SET PT:
(40) 5.0 E+4 CPM l
NI DET PWR SUPPLY N/A l
CUTOFF PWR LVL:
(15)
NI DET PWR SUPPLY N/A l
TURN ON PWR LVL (15)
INSTR FAIL MODE:
(30)
LOW TEMP COMP FOR DP N/A (Y, N, N/A)
XHTRS:
(3)
LEVEL REF LEG:
(3)
N/A (DRY, WET)
UNIQUE SYS DESC:
(600)
RAD MONITOR R-15, CONDENSER AIR EJECTOR GAS HONITOR - CONTAINS A GAMMA SENSITIVE GM TUBE.
PROVIDES THE FOLLOWING AUTOMATIC ESF ACTUATION:
IS'OLATE S/G BLOWDOWN AND SHIFT CONDENSER AIR EJECTOR DISCHARGE TO EXHAUST VIA AUX BLDG VENT.
Form EPMP ?.5-31 4
-... ~
FE21 : '--
EPHP 9.5 Original
~
Page 1 of 1 ERDS PARAMETERS - DATA POINT LIBRARY KEWAUNEE NUCLEAR POWER PLANT FIELD:
- - m ITEM LENGTR KNPP ERDS DATA DATE
(8) 04/23/91 REACTOR UNIT (3)
KW1 DATA FEEDER:
(10)
N/A NRC ERDS PARAM:
(12)
CNTMNT RAD POINT ID:
(12)
(40)
CNTMT AREA HI RNG R-40 GENERIC /COND DESC:
(32)
RADIATION LEVEL IN CONTAINMENT ANALOG / DIGITAL:
(1)
A (A, D)
ENGR UNITS / DIG STs (12)
R/HR ENGR 'JNITS CONVERS:
(40)
N/A MIN INSTP RANGE:
(10) 1.0 E+0 MAX INSTR RANGE:
(10) 1.0 E+8 IERO PT REF:
(6)
N/A RET PT NOTES:
(40)
N/A PROC OR SENS:
(1)
S (P, S)
NUMBER OF SENSORS:
(3) 1 HOW PROCESSED:
(40)
N/A SENSOR LOCATIONS:
(40)
CONTAINMENT ALARM / TRIP SET PT:
(40)
NONE NI DET PWR SUPPLY N/A CUTOFF PWR LVL (15)
NI DET PWR,9UPPLY N/A TURN ON PWR LVL:
(15)
INSTR FAIL MODE:
(30)
LOW TEMP COMP FOR DP N/A (Y, N, M/A)
XMTRS:
(3)
LEVEL REF LEG (3)
N/A (DRY, WET)
UNIQUE SYS DESC:
(600)
RAD MONITOR R-40, CONTAINMENT AREA HI RANGE RAD MONITOR TRAIN A - ION CHAMBER.
Foru EPMP 9.5-32
771 * ? 979 i
EPHP 9.5 '
Original Page 1 of 1 ERDS PARAMETERS - DATA POINT LIBRARY KEWAUNEE NUCLEAR POWER PLANT FIELD' ITEM LENGTH KNPP ERD _S, DATA DATES-(8) 04/23/91 REACTOR UNIT (3)
KW1 DATA FEEDER:
(10)
N/A NRC ERDS PARAM:
(12)
RCS LTDN RAD POINT ID:
(12)
(40)
LCTDOWN LINE - AREA 9 -
CENERIC/COND DESC:
(32)
RAD LEVEL OF RCS LETDOWN LINE
, ANALOG / DIGITAL:
(1)
A (A, D)
ENGR UNITS / DIG ST:
(12)
R/HR ENGR UNITS COFVERS:
(40)
N/A MIN INSTR RANGE:
(10) 1.0 E-3 MAX INSTR RAhCE:
(10) 1.0 E+2 ZERO PT REF:
(6)
N/A REF PT NOTES:
(40)
FfA PROC OR SENS:
(1)
S (P, S)
NUMBER OF SENSORS:
(3) 1 HOW PROCESSEDs (40)
N/A SENSOR LOCATIONS:
(40)
DISCHARGE OF,LETDCWN HTEXCH, AUX BLDG ALARM / TRIP SET PT:
(40) 300 MR/HR NI DET PWR SUPPLY N/A CUTOFP PWR LVL (13)
NI DET PWP SUPPLY N/A TURN ON PWR LVL (15)
INSTR FAIL MODE:
(30)
LOW TEMP COMP FOR DP N/A (Y, N, N/A)
XMTRS:
(3)
LEVEL REF LEGS, (3)
N/A (DRY, WET)
UNIQUE SYS DESC:
(600)
ARKARADIATIONHONITOR-GMTUBEDET"} TOR.
Form EPHP 9.5-33
[2 j E6h73715 s
Origibh1 Page 1 of 1 ERDS PARAMETERS - DATA POINT LIBRARY KEWAUNEE NUCLFAR POWER PLANT
" FIELD m
ITEM LENGTH KNPP ERDS DATA DATE:
(8) 04/23/91 REACTOR UNIT (3)
KW1 DATA FEEDER:
(10)
N/A NRC ERDS PARAM:
(12)
MAIN SL 1/A POINT ID:
(12)
( 4 0 ',-
STM LINE 1A HI R-32 GENERIC /COND DESC:
(32)
STM GEN A STEAM LINE RAD LEVEL ANALOG / DIGITAL:
(1)
A (A, D)
ENGR UNITS / DIG ST:
(12)
R/HK ENGR UNITS CONVERS:
(40)
N/A MIN INSTR RANGE:
(10) 1.O E+0 MAX INSTR RANGE:
(10) 1.0 Ev4 ZERO PT REF:
(6)
N/A REF PT NOTES:
(40)
N/A PROC OR SENS:
(1) 5 (P, S)
NUMBER OF SENSORS:
(3) 1 HOW PROCESSED:
(40)
N/A SENSOR' LOCATIONS:
(40)
,0N 24' DIAH. MS VENT HEADER, AUX _B_LDG ALARM / TRIP SET PT:
(40)
N/A NI UET PWR SUPPLY N/A CUTOFF PWR LVL (15)
NI DET PWR SUPPLY N/A TURN ON PWR LVL (15)
INSTR FAIL MODE:
(30)
LOW TEMP COMP FOR DP N/A (Y, N, N/A)
XMTRS:
(3)
LEVEL REF LEG (3)
N/A (DRY, WET)
UNIQUE SYS DESC:
(600)
RAD MON! TOR R-32, HI RANGE STEAM LINE MONITOR TRAIN A - JON CHAMBER DETECTOR.
Form EPMP 9.5-3 4
p* { J j } ggg i
EPMP 9.5 i
Original Page 1 of 1 a
ERDS PARAMETERS - DATA POINT LIBRARY KEWAUNEE NOCLEAR POWER PLANT FIELD a' r-ITEM LENGTH KNPP ERDS DATA-DATZ:
(8) 04/23/91 REACTOR UNIT:
(3)
KW1 D*.TA FEEDER:
(10)
N/A NRC ERDS PARAM:
(12)
MAIN SL 2/B POINT ID:
(12)
(40)
STM LINE IB,HI R-34 GENERIC /COND DESC:
(32)
STM GEN B STEAM LINE RAD LEVEL ANALOG / DIGITAL:
(1)
A (A, D)
ENGR UNITS / DIG STa (12)
R/HR ENGR UNITS CONVERS:
(40)
N/A MIN INSTR RANGE:
(10) 1.0 E+0 MAX INSTR RANGE:
(10) 1.0 E+4 ZERO PT REF:
(6)
N/A REF PT NOTES:
(40)
N/A l
PROC OR SENS:
(1)
S (P, S)
NUMBER OF SENSORS:
(3) 1 HOW PROCESSED:
(40)
N/A S2NSOR LOCATIONS:
(40)
ON 24" DIAM. MS VENT HEADER, AUX BLDG ALARM / TRIP SCT PT:
(40)
N/A NI DET FWR SUPPLY N/A CUTOFF PWR LVL (15)
NI DET PWR SUPPLY N/A TURN ON PWR LVL (15)
INSTR PAIL MODE:
(30)
LOW TEMP COMP FOR DP N/A (Y, N, N/A)
XMTRS:
(3)
LEVEL REF LEC:
(3)
N/A (DRY, WET)
UNIQUE SYS DESC:
(600)
RAD MONITOR R-34, HI RANGE STEAM LINE MONITOR TRAIN B - ION CHAMBIR DETECTOR.
Form EPHP 9.5-35
f 50 I 2 b^d 9.5 Driginel Pcg3 1 of 1 4
ERDS PARAMETERS - DATA POINT LIBRARY KEWAUNEE NUCLEAR POWER PLANT FIELD KNPP ERDS DATA ITEM LENGTH DATE:
(8) 04/23/91 REACTOR UNIT:
(3)
KW1 DATA FEEDER:
(10)
N/A NRC ERDS PARAM:
(12)
SG BD RAD POINT ID:
(12)
(40)
STEAM GENERATOR BLOWDOW GENERIC /COND DESC:
(32)
STM GEN BLOWDOWN RAD LEVEL ANALOG / DIGITAL:
(1)
A (A, D)
ENGR UNITS / DIG ST:
(12)
CPM ENGR ONITS CONVERS:
(40)
N/A MIN INSTR RANGE:
(10) 1.0 E+1 MAX INSTR RANGE:
(10) 1.0 E+6 ZERO PT REF:
(6)
N/A REF PT NOTES:
(40)
N/A PROC OR SENS:
(1)
S (Pe S)
NUMBER OF SENSORS:
(3) 1 HOW PROCESSED:
(40)
N/A SENSOR LOCATIONS:
(40)
DOWNSTREAM OF S/G BLOWDOWN HTEXCH'S ALARM / TRIP SET PT:
(40) 4.5 E+2 CPM NI DET PWR SUPPLY N/A CUTOFF PWR LVL (15)
NI DET PWR SUPPLY N/A TURN ON PWR LVL (15)
INSTR FAIL MODE:
(30)
LOW TEMP COMP FOR DP N/A (Y, N, N/A)
XHTRS:
(3)
LEVEL REF LEG:
(3)
N/A (DRY, WET)
UNIQUE SfS DESC:
(600)
STEAM GENERATOR BLOWDOWN SYSTEM LIQUID SAMPLE MONITOR R NAI SCINT. DETECTOR.
PROVIDES TafE FOLLOWING AUTOMATIC ESF FUNCTION:
ISOLATE S/G BLOWDOWN AND SHIFT CONDENSER AIR EJECTOR DISCHARGE TO EXHACIT VIA THE AUX BLDO VENT STACK. FOLLOWING S/G BLOWDOWN ISOLATION, MANUAL VALV3 MANIPULATION ALLOWS MANUAL SAMPLING IN SAMPLE ROOM.
THIS RAD MONITOR IS COMMON FOR BOTH TRAIN A AND TRAIN B OF S/G BLOWDOWN.
Form EPMP 9.5-36
EPMP 9.$
Origins 1 Pago 1 of 1 4
ERDS PARA)ETERS - DATA POINT LIBRARY KEWAUNEE NUCLEAR POWER PLANT FIELD ITEM LENGTH KNPP ERDS DATA
_DATE:
(8) 02/03/93 REACTOR UNIT:
(3)
KW1 DATA FEEDER:
(10)
N/A NRC ERDS PARAM:
(12)
CTMNT PRESS POINT ID:
(12)
(40)
CNTMT PRES Al WIDE RANGE GENERIC /COND DESC:
(32)
CONTAINMENT PRESSURF ANALOG / DIGITAL:
(1)
A (A, D)
ENGR UNITS / DIG ST:
(22)
PSID ENGR UNITS CONVERSs (40)
N/A MIN INSTR RANCE:
(10)
-5 MAX INSTR RANGE:
(10) 200
)
ZERO PT REF:
(6)
N/A i
REF PT NOTES:
(40)
N/A
{
PROC OR SENS:
(1)
S (P, S) *^
NUMBER OF SENSORS:
(3) 1 HOW PROCESSED:
(40)
N/A SENSOR LOCATIONS:
(40)
OUTSIDE CNTMNT - REF. PENETR. 27NE ALARM / TRIP SET PT:
(40)
N/A NI DET PWR SUPPLY N/A CUTOFF PWR LVL:
(15)
NI DET PWR SUPPLY N/A TURN ON PWR LVL (15)
INSTR FAIL MODE:
(30)
LOW TEMP COMP FOR DP N/A (Y, N, N/A)
IMTRS:
(3)
LEVEL REF LEG (3)
N/A (DRY, WET)
UNIQUE SYS DESC:
(600)
INSTRUMENT PT-21132 Form EPMP 9.5-37
I '.,"
EPMP 9'.5 Originci
- 1 a-Page 1 of 1 J
l ERDS PARAKETERS - DATA POINT LIBRARY j
KEWAUNEE NUCLEAR POWER PLANT 1
FIELD.
ITEM' LENGTH-KNPP ERD 3 DATA-DATE:
(8) 02/03/93 REACTOR UNIT:
(3)
KW1 DATA FEEDER:
(10)
N/A NRC ERDS PARAM:
(12)
CTMNT TEMP POINT ID:
(12)
T1000A REVISION PLANT SPEC PT DESC:
(40)
CNTMT ELEVATION 626*T REVISION GENERIC /COND DESC:
(32)
CONTAINMENT TEMPERATURE ANALOG / DIGITAL:
(1)
A REVISION ENGR UNITS / DIG ST:
(12)
DEG F REVISION ENGR UNITS CONVERS:
(40)
N/A REVISION MIN INSTR RANGE:
(10) 20 REVISION KAX INSTR RANGE:
(10) 385 REVISION ZERO PT REF:
(6)
NA REVISION REVIJION REF PT NOTES:
(40)
NA,_
PROC OR SENS:
(1)
S REVISION NUMBER OF SENSORS:
(3) 1 REVISION HOW PROCESSED:
(40)
N/A REVISION SENSOR LOCATIONS:
(40)
INSIDE CONTAINMENT ELEVATION 626
REVISION ALARM / TRIP SET PT:
(40)
N/A REVISION HI DET PWR SUPPLY N/A REVISION CUTOFF PWR LVL (15)
HI DET PkR SUPPLY N/A
' REVISION TURN ON PWR LVL (15)
INSTR FAIL MODE:
(30)
' REVISION TEMP CORP FOR DP N/A REVISION XMTRS:
(3)
LEVEL REF LEG (3)
N/A REVISION UNIQUE SYS DESC:
(600)
N/A REVISION Form EPNP 9.5-38
s.,
r
+,a EPHP 9.f Originci Pogo 1 of?1 4
~.
ERDS PARAMETERS - DATA POINT LIBRAF.t KEWAUNEE NUCLEAR POWER PLANT FIELD ITEM LENGTH KNPP ERDS DATA DATE:
(8) 04/23/91 REACOR UNIT:
(3) wi DATA FEEDER:
(10)
N/A NRC 1:RDS PARAMs (12)
H2 CONC POINT ID:
(12)< X8001A I
(40)
CNTMT H2 TRAIN A GENERIC /COND DESC:
(32)
CONTAINMENT HYDROGEN CONCEN.
ANALOC/ DIGITAL:
(1)
A (A, D)
ENGR UNITS / DIG ST:
(12)
_ENCR UNITS CONVERS:
(40)
N/A MIN INSTR RANGE:
(10) 0 l.1AX INSTR RANGE:
(10) 10 ZERO PT REF:
(6)
N/A REF PT NOTES:
(40)
N/A PROC OR SENS:
(1)
S (P, S)
NUMBER OF SENSORS:
(3) 1 HOW PROCESSED:
(40)
N/A SENSOR LOCATIONS:
(40)
AUX BLDG 586 FT ELEVATION ALARH/ TRIP SET PT:
(40)
N/A NI DET PWR SUPPLY N/A CUTOFF PWR LVL:
(15)
NI DET PWR SUPPLY N/A TtfRN ON PWR LVL:
(15)
INSTR FAIL HODE:
(30)
LOW TEMP COMP POR UP N/A (Y, N, N/A)
XMTRS:
(3)
LEVEL REF LEC (3)
N/A (DRY, WET)
UNIQUE SYS DESC:
(600)
MUST BE VALVED IN POST ACCIDENT TO BE VALID.
l Form EPNP 9.5-39 l
FE3 kgag;33 S
Origins 1
.j Paga-1.of 1 I
l-
.)
ERDS PARAMETERS - DATA POINT LIBRARY KEWAUNEE NUCLEAR POWER PLANT
{
FIELD ITEM.
LENGTR-KNPP ERDS DATA' DATE:
(8) 02/03/93 REACTOR UNIT:
(3)
KW1 DATA FEEDER:
(10)
N/A NRC ERDS PARAM:
(12)
BWST LEVEL POINT ID:
'(12)
L8008A REVISIC,N_
(45)
RWST LEVEL - 24062 REVISION GENERIC /COND DESC:
(32)
BORATED WATER SIORAGE TANK LEVEL ANALOG / DIGITAL:
(1)
A REVISION ENGR UNITS / DIG ST:
(12)
PCT REVISION ENGR UNITS CONVERS:
(40)
N/A REVISION NIN INSTR RANGE:
(10)
O REVISION MAX INSTR RANGE:
(10) 100 REVISION ZERO PT REF:
(6)
N/A REVISION REF PT NOTES:
(40)
N/A REVISION PPOC OR SENS:
(1)
S REVISION NUMBER OF SENSORS:
(3) 1 REVISION REVISION HOW PROCESSED:
(40)
N/A SENSOR LOCATIONS:
(40)
AUX BLDG 586* ELEVATION REVISION _
ALARM / TRIP SET PT:
(40)
N/A REVISION REVISION NI DET PWR SUPPLY N/A CUTOFF PWR LVL (15)
NI DkT PWR SUPPLY N/A REVISION-TURN ON PWR INL (15)
REVISION INSTR FAIL MODES-(30)-
LOW REVISION TEMP COMP FOR DP N/A XM1RS:
(3)
LEVEL RET LEG:
(3)
N/A
-REVISION UNIQUE SYS DESC:
(600)
INSTRUMENT 24062 REVISION Porm EPNP 9.5-40 l
l
.r--'
r,--
a
.~-
"' T '
RPMP_9.5 Origin 21 Pago 1 of 1 g
ERDS PARAMETERS - DATA POINT LIBRARY KIWAUNEE NUCLEAR POWER PLANT FIELD ITEM -
LENGTH KNPP ERDS DATA DATE:
(8) 04/23/91 REACTOR UNIT:
(3)
KW1 DATA FEEDER:
(10)
N/A NRC ERDS PARAM:
(12)
WIND SPEED POINT ID:
(12)
(40)
PRI TWR - 60H WIND SPEED GENERIC /COND DESC:
(32)
WIND SPEED AT REACTOR SITE ANALOG / DIGITAL:
(1)
A (A, D)
ENCR UNITS / DIG ST:
(12)
MPH 11 ENGR UNITS CONVERS:
(40)
N/A MIN INSTR RANGE:
(10)
O MAX INSTR RANGE:
(10) 100 ZERO PT REF:
(6)
N/A REF PT NOTES:
(40)
N/A PROC OR SENS:
(1)
S (P, S)
NUMBER OF SENSORS:
(3) 1 HOW PROCESSED:
(40)
N/A SENSOR LOCATIONS:
(40) 60 METER LEVEL, 1:00 FT FROM CONTAINMENT ALARM / TRIP SET PT:
(40)
N/A NI DET PWR SUPPLY N/A CUTOFF PWR LVL:
(15)
NI DET PWR SUPPLY N/A TURN ON PWR LVL:
I15)
INSTR FAIL MODE:
(30)
LOW TEMP COMP FOR DP N/A (Y,
N, N/A)
XMTRS:
(3)
LEVEL REF LEC:
(3)
N/A (DRY, WET)
UNIQUE SYS DESC3 (600)
MEASURED BY A THREE-CUP ANEMOMETER.
Foris EPMP 9.5-41
dPh3033 j
Origiddl Pag: 1 of 1
~
ERDS PARAMETERS - DATA POINT LIBRARY KEWAUNEE NUCLEAR POWER PLANT e_
FIELD ~
ITEM LENGTH KNPP ERDS DATA DATE:
(8) 04/23/h.
REACTOR UNIT:
(3)
KW1 DATA FEEDER:
(10)
N/A NRC ERDS PARAM:
(12)
WIND DIR POINT ID:
(12)
MOOO2G PLANT SPEC PT DESC (40)
PRI TWR - 60M WIND DIR GENERIC /COND DESC:
(32)
WIND DIRECTION AT M CTOR SITE ANALOG / DIGITAL:
(1)
A (A, D)
ENGR UNITS / DIG ST (12)
DEGFR ENGR UNITS CONVERS:
(40)
N/A MIN INSTR RANGE:
(10)
O MAX INSTR RANGE:
(10) 540 ZERO PT REF:
(6)
N/A REF PT NOTES:
(40)
N/A PROC OR SENS:
(1)
S (P, S)
NUMBER OF SENSORS:
(3) 1 HOW PROCESSED:
(40)
N/A SENSOR LOCATIONS:
(40) 60 METER LEVEL, 1200 FT FROM CONTAINMENT ALARM / TRIP SET PT:
(40)
N/A NI DET PWR SUPPLY N/A CUTOFF PWR LVL (15)
NI DET PWR SUPPLY N/A TURN ON PWR LVLt (15)
INSTR FAIL MODE:
(30)
UNKNOWN TEMP COMP FOR DP N/A (Y, N, N/A)
XHTRS:
(3)
LEVEL REF LEG:
(3)
N/A (DRY, WET)
UNIQUE SYS DESC:
(600)
WIND DIRECTION IS SU SED BY A WIND VAhr.:.
Form EPMP 9.5-42 v
FO kPp:s:5
?,,.
Origi541
[
Pego 1 of 1
(
ERDS PARAMETERS - DATA POINT LIBRARY KEWAUNEE NUCLEAR POWER PLANT FIELD ITEM LENOTH KNPP ERDS DATA
. ana:=
DATE:
(8) 04/23/91 REACTOR UNIT:
(3)
KW1 DATA FEEDER:
(10)
N/A NRC ERDS PARAM:
(12)
STAB CLASS POINT ID:
(12)
(40)
PRI TWR DELTA TEMP GENERIC /COND DESC:
(32)
AIR STABILITY AT REACTOR SITE ANALOG / DIGITAL:
(1)
A (A, D)
ENGR UNITS / DIG ST:
(12)
DEGF ENGR UNITS CONVZRS:
(40)
N/A MIN INSTR RANCE:
(10)
-2 MAX INSTR RANGE:
(10)
+40 ZERO PT REF:
(6)
N/A REF PT NOTES:
(40)
N/A PROC OR SENS:
(1)
S (P, 5)
NUMBER OF SENSORS:
(3) 1 HOW PROCESSEDs (40)
N/A SENSOR LOCATIONS:
(40) 60 KETER TOWER, 1200 FT FROM CONTAINMENT ALARM / TRIP SET PT:
(40)
N/A NI DET PWR SUPPLY N/A CUTOFF PWR LVL (15)
NI DET P'WR SUPPLY N/A TURN ON PWR LVL:
(15)
INSTR FAIL MODE:
(30)
UNKNOWN TEMP COMP FOR DP N/A (Y,
N, N/A)
XMTRS:
(3)
LEVEL REF LEG:
(3)
N/A (DRY, WET)
UNIQUE SYS DESC:
(600)
AMBIENT TEMPERATURE IS MEASURED BY 4 WIRE PLATINUM RESISTANCE TEMPERATURE BULBS HOUNTED IN ASPIRATED RADIATION SHIELD ASSEMBLIES AT 10 METERS AND 60 METERS ABOVE GROUND.
Form EPHP 9.5-43
-