_ Revision 1 Technical Specifications 3.2 Beactor Control and Safety System 3.2.1 Control Assemblics Specification (s)

The reactor shall not be operated unless the control rods are operable, and

a. Control rods shall not be operable if damage is apparent to the rod or drive assemblies.
b. The scrsm time measured from the instant a simulated signal reaches the value of a limiting safe ty system setting to the instant. that the slowest scrammabl: control rod reaches its full;i inserted position shall not exceed 1 second,
c. Maximum reactivity insertion rate of a standard control rod shall be less than 0.2% Ak/k per second.

3.2.2 Reactor Control System Specification (s)

The reactor shall not be operable unless the minimum safety interlocks are operable.

The following control system safety interlocks shall be operable:

Interlocks Number Effective Mode Rod Drive Control Operable Function Manual

  • Pulse
a. Startup Withdrawal 4

prevent rod X

Standard control rods withdrawal far Transient control rod less than 2 counts per see

b. Simultaneous Withdrawal 4 prevent rad X

Standard control rods withdrawal for Transient control rod two or more rods

c. Non pulse condition 1

prevent withdrawal X Transient control rod for drive not down except square-wave

d. Pulse Withdrawal 3

prevent withdrawal

-X Standard control rods of non pulse rods

e. Transient Withdrawal 1

prevent rod X

Transient control rod withdrawal for more than 1 kilowatt power

  • Manual mode includes Auto and Squarn Wave modes 12/90 Page 14 9302120155 930129 PDR ADOCK O$000602 PDR p

7-l 'j '

Revision 1l Technical Specifications

+

3.2 Reactor Control and Safety System 3.2.1 Control Assemblies Specification (s)

The reactor shall not be operated unless the control rods are operable, and

a. Control rods shall not be operable if damcge is apparent to the rod or drive assemblies,
b. The scram time measured from the instant a simulated - signal reaches the value of a limiting safety system setting to the instant that the slowest scrammable control rod reaches its fully inserted position shall not exceed 1 second.
c. Maximum reactivity insertion rate of a standard control rod shall be less than 0.21 Ak/k per second.

3.2.2 Reactor Control System Specification (s)

The reactor shall not be operable un10.;a the minimum safety interlocks are operable. The following control system safety interlocks shall be operable:

Interlocks Number Effective Mode

__ Rod Drive Control Operable Function Manual

  • Pulse
a. Startup Withdrawal 4(4)** prevent rod X

Standard cont il rods withdrawal for Transient control rod less than 2 counts per see

b. Simultaneous Withdrawal 4(3)** prevent rod X

Standard control rods withdrawal for Transient control roo two or more rods

c. Non pulse condition 1

prevent withdrawal X Transient control rod for drive not down j

except square wave

d. Pulse Withdrawal 3

prevent wit'.drawal X

Standard control rods of non pulse rods

e. Transient Withdrawal 1

prevent rod.

X Transient control rod withdrawal for more than 1 kilowatt power

  • Manual mode includes Auto and Square Wave modes
    • (a) includes regulating rod in Auto and Square Wave modes
    • (b) excludes regulating rod in Auto and Square Wave modes 12/90 amendment 1/93 Page 14'

,