ML20128G066

From kanterella
Jump to navigation Jump to search
Ack Receipt of Const QA Manual,Rev 13,changing as-built Program Provisions.Revised Program Satisfies Requirements of 10CFR50,App B & Acceptable
ML20128G066
Person / Time
Site: Clinton Constellation icon.png
Issue date: 07/03/1985
From: Spessard R
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To: Gerstner W
ILLINOIS POWER CO.
References
NUDOCS 8507090026
Download: ML20128G066 (1)


Text

\

g 3 60 Docket No. 50-461 Illinois Power Company ATTN: Mr..W. C. Gerstner Executive Vice President

-500 South 27th Street Decatur, IL 62525 Gentlemen:

Thank you for the submittal of your Construction Quality Assurance Manual, Revision 13. We have reviewed the change relative to the as-built program provisions and find that the revised program continues to satisfy the requirements of 10 CFR 50, Appendix B, and is therefore acceptable.

We appreciate your timely submittal of the information required by 10 CFR 50.55(f).

Please contact Mr. Frank Hawkins of my staff (312-790-5555) with any questins you have regarding this matter.

Sincerely,

" Original signed by R. I, spessarf R. L. Spessard, Director.

Division of Reactor Safety cc: DMB/ Document Control Desk (RIDS)

Resident Inspector, RIII Richard Hubbard Gary N. Wright, Manager Nuclear Facility Safety Jean Foy, Prairie Alliance Allen Samelson, Assistant Attorney General, Environmental Control Division H. S. Taylor, Quality Assurance Division G. T. Ankrum, IE RI A III :II R I. RII,(

, #1 5 )

e es dT aridel/lc Hawkins n Shessard 7/1/85 8507090026 850703 PDR ADOCK 05 8 10