ML20128F568

From kanterella
Jump to navigation Jump to search
Discusses Ltr Forwarding Demand for Payment Re Invoice AM07121-91.Requests Clarification Re Licensing Fees
ML20128F568
Person / Time
Site: 07100349
Issue date: 11/02/1992
From: Klose G
CATERPILLAR TRACTOR CO.
To: Gerard Jackson
NRC OFFICE OF THE CONTROLLER
Shared Package
ML20128F543 List:
References
NUDOCS 9302110457
Download: ML20128F568 (6)


Text

{{#Wiki_filter:.... Caterpillar ine, Peona hoving Ground P.0 Ban 1895 Peona tihnois 51656 1195 November 2,1992 Glenda C. Jackson Materials License Fee Section License Fee and Debt Collection Branch Division of Accounting and Finance Office of the Controller U. S. Nuclear Regulatory Commission Washington, D.C. 20555 On 30 October 92 we received a " Demand for Payment" from a collection agency for $'.,653.76 plus continually accruing interest for overdue payment of a Licensing fee for five instruments that use radiation to measure soil nioisture and density Attachment A is a copy of the " Demand for Payment". Attachments B, C, D, and E are copics of the " Radioactive Material License" issued by the State of Illinois Department of Nuclear Safety for these instruments. Note that it is dated May 2,1991 and expires June 30,1995. Our understanding was, and is, that State licensing only now is required for these devices. If this is incorrect; if both State und Federal licensing is reqtiired, please natify me promptly. without going through a collection agency - and we will pay the full amount immediately. We have not responded to your invoices AM07121-91 dated 08/09/91; 09/10/91; and 10/08/91 because cach stated that nonpayment of your annual fee may result in the revocation of your license. That is exactly what we were trying to do - drop our Federal License because we thought the Illinois license was sufLcient.. Yota October 18,1991 letter to Gary Kramer refers to an included 42 page document of the CFR (V56/N132/31472 through 31513) as indicating that a positive notification of not renevang a license is required. My reasonably thorough reading (one time only) of this document has not detected where this is stated, if State licensing is sullicient and we have erred by not notifying you that we did not want to renew the unnecessary Federal License, please consider out full payment of your direct billing such notification Very truly your, p6 Supervismg Engmeed Vehicle Development Peona Proving Ground G L. Klose Telephone (309) 698-5936 pas Copy to: Kurt Gelbach, AB7310. Legal Dept. -l 9302110457 930125 PDR ADOCK 07100349 C PDR

DEMAND FOR PAYMENT I BY PAYC0 - GENERAL AMERICAN CRerITS, INC. . A COLLECTION AGENCY 000000-04223215 -{0C 3 Ef ff 6] M %] P.O. BOX 7169 DUBLIN OH 43017 402 ADDRESS CORRECTION REQUESTED YOUR CREDITOR ACCOUNT NUMBER NUCLEAR REGULATORY COMMISSION BPA 007 AM07121-91 0349 - AMOUNT 1,800.00 853.76 2,653.7e MAllYOUR PALIENT TO CATTERPILLAR TRACTOR INC PAYCO-GENERAL AMERICAN CREDITS PO BOX 1995 P.O. BOX 7169 PEORIA IL 61656-1895 00BLIN OH 43017 I _ _. _ _ ~ 11 161A T66-0803-~ ~

== - -

_7 ~ n-


- T HI S-IS~ A~ O E M A N D - FOR=

~ FULL,P AY MUNL OP -YOUR DE BT ~-- ;._;--- u ._n_ YOURFSER100 SLY: 'PAST'DUETACCOUNT:HAS~BEEN GIVEN5TO US'FOR. "F - - IMMEDI ATLATTENTION.- YOU H AVE-H AD AMPLE? TI ME' TO P AY-YOUR DEBTi ~ ~ 7 AS'EXPtAINED 0N-THE' __ _YOU-H AVE _ NOT.. -I F" THER E TS~'A=V ACID ~RE-A S ON v REVERSE SIDE'0F THIS LETT ER,_- WE^ SUGGEST YOU CONT ACT ' 05. ~ IF NOT -- P AY U S.-- ~ PRINCIPAL DUE 1,800.00 I NT EP.E ST AND PENAL'1IES DUE 303.04 - COLL ECT7 0N-FE E DUE' 400.72 ADMINISTRATIVE FEE DUE 150.00 TOTAL DUE $~ 2,653 76 E. ~ MAKE YOUR CHECK-OR. MONEY ORDER PAYABLE TO NOT TO PAYCO.- NUCLEAR REGULATORY COMMISSION, ~~ PLEASE'00. NOT SEND-CASH THROUGH THE MAIL. _. _. _._ z - ~ ~ THE BALANCE REFLECTEU ON THIS STATEM.NT MAY NOT REFLECT THE EXACT AMOUNT OF INTEREST WHICH IS ACCRUING DAILY. PLEASE CONTACT 00R OFFICE TO FINO_00T YOUR_ EXACT PAYOUT BALANCE.

pNS FLM ood 01 (4/89) STATE OF ILLINOIS DEPARTMENT OF NUCLEAR SAFETY RADIOACTIVE MATERIAL LICENSE Diwso4 or RAo.oActrv E MATERLALS 1035 OUTER PARK DAIVE SPRINGFIELD, ILLINOIS 62704 Pursusse to the niinois Reciation Protec* ton Act and the rytes and regulat6ons in 32 Ildnose Administrative Coce promulgated thereunder, and en reha+ ice on statemems ana represervainone he evotore maos by tne urensee, a teense m hereby eswed autrertaing the incensee to recones, sequwe, own, possess and transist reda.saethe maiernaltal listed harem; and to use auen red *osetNo matematts) for the purpose <st and at the place (s) designated betow. This license is sab oet te sit i appl 6 canoe rules. regviat6ses am eccess of the avois Depanmerit of Nuciear f,aiety new or hereafter vi eneet and to any condalons specified in the license. UCE NSE E tt CE.NS E NUuBER E A aTION DATF Caterpillar, Inc. IL-01602-01 M* Peoria Proving Ground aurwoutwTwuwecn arreneNee ~uveen P.O. Box 1895 20 unatoCtNse 9102609 Peoria, 1111ncis 61656-1895 g in.nei aem Attention: Mr. Gary L. Xramer i ^O Pnsvious aucwourwTs *nt vo.o. ~aa= mec es' ^ ~~>~~ cr~isiu's a ee we~. _.= _ tion _S _afety Officer _ _ _ _. _. _ Radia i In accordance with application dated M@icense Number 11-01602-01 is issued as follows: i i l = = ^cT mtv' ' a u "

  • SEss a nm n e m uoE creviCat anwr Pesu reau l

PCR$QJRCE l UMIT ] A. Cs-137 Sealed Source - Campbell Pacific 10 mci Any Nuclear Model CPN-131 B. Am-241 Sealed Scurce - Campbell Pacific 50 mci Any (AmBe) Nuclear Model CPN-131 C. Ra-226 Sealed Source - Amersham Model 5 mci Any (RaBe) RAN.W25 D. Am-241 Sealed Source - Campbell Pacific 50 mci Any (AmBe) Nuclear Model CPN-131 E. Cs-137 Sealed Source - E. I. Dupont 11 mci Any De Numours & Co., Inc. (NEN) Model 560A F. Am-241 Scaled Source - E. 1. Dupont 60 mci Any (AmBe) De Numours & Co., Inc. AUTHCRIZED USE: A. and B. For use in Campbell Pacific Nuclear Model B(R) gauges for measuring the moisture /densi ty of various materials. C. For use in Seaman Nuclear Model C-200 gauges for measuring the moisture / density of various materials.

  • pCkmicrocurte; mCMidl*cu ie; Cl-Cune; M64 Megabecquero: G3 Cgacecquere; TBq-Teraoecqueret; 6 gram; pg trwrogtem;. ng.htiegraen r

4 M) 8Y: / jGATE I PN2E r7 PAGES da.~-ch. 1 -/ I i I 1 4 jMay 2,1991 l l g G.

inger, ead o Lice ection v

4 e STATE OFILLINOIS 'lONS.FLM Oo4 02 (4/89) DEPARTMENT OF NUCLEAR S AFETY RADIOACTIVE MATERIAL LICENSE tsuse suusen w a d ro.ucs exetaatio~ oAie uce use e Caterpillar, Inc. IL- 01602-01 2""' **

  • June 30, 1995 l "ygv l **mgy

{ l estwic4t.m.< ws Cet ronu nAccu x uct rroa D. For use in Campbell Pacific Nuclear Model 500 Series gauges for measuring the moisture / density of various materiais. E. and F. For use in Soiltest, Inc. Model NIC-SOT gauges for measuring the moisture / density of various materials. CONDITIONS 1. Radioactive meterial shall be used at the licensec's facilities located at the Peoria Proving Ground, Spring Creek Road, Peoria. Illinois and at temporary jobsites of the licensee in the State of Illinois in accordance with statements, reprecentations and proce'iures listed in License Condition 14. 2. Radioact ue material shall be used only at temporary jobsites of the licensee in the State of Illinois. 3. Radioactive material shali be used b <, or under the supervision and in the physical prasence of Gary L. Kramer or individuals who have been trained in accordance with application dated July 11, 1990 and letters dated November 20, 1990 and February 4, 1991. The licensee shall maintain training records of all designated users. 4. The Radiation Safety Officer for the activities authorized by this license is Gary L. Kramer. 5. The licensee shall comply with the provis1ons of the regulations contained in 32 Ill. Adm. Code. 6. The licensee shall maintain records showing the receipt, cransfer, use, storage and disposal of all sources of radiation in accordance with 32 Ill. Adm. Code 310.40. 7. A. (1) Each sealed source shall be tested for leakage and/or contamination at intervals not to exceed six months. In the absence of a cert.ficate from a transferor indicating that a test has been made within six months prior to transfer, the sealed source shall not be put into use until tested. (2) Notwithstanding the periodic leak test required by this condition, any licensed sealed source is exempt from such leak tests when the source contains 100 microcuries or less of beta and/or gamma emitting material or ten microcuries or loss of alpha emitting material. B. The periodic leak ' et required by this condition does not apply to sealed sources that have been remt, a from use and are in protective and secure storage. The sources excepted from this test shall be tested for leakage prior to use or transfer to another person, unless they have been leak tested within six months prior to the date of use or transfer.

  • pCbmerecure, mCWMu'*e; CbCurte V04-Megacecqueret CBq-Gigacecoueret; TBo TeranecQwet; 0-gram; pg mu,mgram; n g-wogram

!CATE [ PaOE PAGES PAGEISGNED6Y: i l Q5ep.heh Klinger, Head of Licensing Section ' May 2, 1991 l 2 4

e lONS.FLM oo4 02 (4/89) STATE OF ILLINOIS DEPARTMENT OF NUCLEAR SAFETY RADIOACTWE MATERIAL LICENSE ~ tinasE s TecEsse suMeen uvaemuun ExPsiirio; cart j Caterpillar, Inc. j IL-01602-01 &"'C SS" _ June 30,1905 I ..j j "gg' ""'"yEm { cecmewswenu i mu wmuce (Condition 7. continued'; C. Leak tests shall be capable of detecting the presence of 0.005 microcurie of radioactiva material on the test sample, or in the case of radium sources, either the presence of 0.005 microcurie of external radon-daughter contamination or the escape of radon at the rate of 0.001 microcurie per 24 hours. The test samples shall be taken from the sealed source or from the surfaces of the device in which the sealed source is permanently or semipermanently mounted or stored upon which one might expect contamination to accumulate. Records of leak test results shall ce kept in units of microcuries and maintained for inspection by the Department. Records of leak test results shall be maintained for Department inspection for a period of five years from the date of analysis of the test sample. D. If the test reveals the presence of 0.005 microcurie or more of removable contamination, or in the case of radium sources, either the presence of 0.005 microcurie of external radon-daughter contamination or the escape of radon at the rate of 0.001 microcurie or greater per 24 hours, the licensee shall immediately, withdraw the sealed source from use and shall cause it to be decontaminated and repaired, or to be disposed of in accordance with the 32 Ill. Adm. Code. A report shall be filed within five days of the test with the Department, describing the source and equipment involved, the test results and the corrective action taken. E. The licensee is authorized to collect leak test samples for analysis by persons specifically authorized by the Department, an Agreement State, a Li censing _ State, or the U.S. Nuclear Regulatory Commission to perform such service <. 8. A. The source holder shall be locked in the "or f" or closed position when the device is not in use. B. Sealed sources shall not be opened or removed from their source holders by the licensee. 9. When performing tests at temporary job sites, the authorized user shall not leave the device unattended. Upon completion of tests, the device shall be locked in the licensee's vehicle or a secure building to prevent unauthorized use, loss, or theft. 10. At any time the licensee is engaged in making measurements by authority of this license at a temporary job site, he shall have a current copy of each of the fc..'owing documents available at the job site for inspection by the Department: A. Manufacturer's instructica manual with appropriate emergency procedures; and B. A copy of the results of the latest test for leakage and/or contamination performed on the sealed source.

  • pCl mcrocwrie; mCbmeces: CI Cune; Mea. Meg 4eecoveret GBqCgatecaue'et n BQ Teracecqueret g-gram; ag micrugeam..g - wog r am P AGE i SGNED BY -

! CATE PCE 7 PAGEE 3 4 JgsgebKlinger,HeadofLicensingSection May 2, 1991

w e STATE OF ILLLNOIS IDNS FLM oo4 02 (4/89) DEPARTMENT OF NUCLEAR SAFETY RADIOACTIVE MATERIAL LICENSE UC E *J5 E E ' LtCENSE NvvBE R AAt30tN*d35M EUIR AllON DATE Caterpillar, Inc. IL-01602-01 X"*c ENSE June 30, 1995 7 _ __ m _ _._ _m ftty a g ryaucacc. } CHEMCA; aN.Df P64YSICAL FOW 11. The licensee shall conduct a physical inventory at intervals not to exceed six months to account for all radioactive material sources received and possessed under the license and shall maintain a record of such inventories, Th3 inventory records shall include the radionuclide, activity, manuf acturer, model m.imber, serial number, activity assay date, the location of the sealed source, date of the inventory and the h entity of the individual (s) performing the inventory. Records of inventories shall be maintained for five years from the date of each inventory. 4 12. The transport of radioactive material or delivery of radioactive material to a carrier for transport shall be in accord ince with the provisions of 32 Ill. Adm. Code 341, 13. The licensee shall not transfer possession and/or control of materials or products containing radioactive material except: A. By transfer as waste to an authorized recipient, B. By transfer to a specifically licansed recipient, or C. As provided otherwise by specific cunditions of this lkense. 14 Except as specifically provided otherwise by the license, the licensee shall possess and use radioactive material described in all schedules of this license in accordance with statements, representations and procedures contained in, or enclosed with, the documents listed below. The regulationt contained in 32 Ill. Adm. Code shall govern unless the statements, representations and procedures in the licensee's application and correspondence are more restrictive than the regulations. 5 A. Application dated July 11, 1990. B. Letters dated November 20, 1990 and February 4,1991. C. Letter, with attachment, dated April 4,

1991, 15.

The licensee is exempt from the provisions of 32 Ill. Adm. Code 330.250(c) for a period of one year from the date of issuance of this license document. JGK:CGV: sid ' aci-rmerocue, mCt-mecu"e. cec u"* MS44 *Gacecover*i, G0c.Gtgasecowen TBq To acecamet-. g g am; ug rmerog am: agattogram PAGE 1 SGNEDev;

WE jPaGE J

PAGES I Jgegg Klinger, Head of Licensing Section !May2,1991 4 4 -}}