DISTRIBUITON D ocket s

ORB #2 Reading RMDiggs FLASil NOTE o

l Dennis L. Ziemann, Chief, Operating Reactors Branch #2, RL

/

j

>DNTICELID NUCLEAR GENERATING PIANT FUEL CLADDING FAILURE 7

j PURPOSE To adviss Management of recent information obtained from examination of irradiated 7 x 7 fuel assemblies presently stored in the Monticello facility spent fuel pool. The Monticello Nuclear Generating Facility is owned and operated by the Northern States Power Cotpany (NSP).

1 OIRONOLOGY 1.

On June 30, 1975, the Office of Inspection and Enforcement Headquarters personnel alerted us of a recent examination of Monticello irradiated 7 x 7 fuel assemblies which revefied significant failure of the fuel cladding.

i 2.

Upon receipt of the above information, I cs11ed Mr. Ned Choules (Region 111) and he gave no the following information:

a.

Ten traadiated 7 x 7 fuel assenblies, three of which were removed in March 1974 and the remaining seven in January 1975, were examined by use of a television camera, b.

1he examination revealed 30 of the 40 corner fuel pins had cracks ranging from 1" to 3' in length. Some crack propagations were of l

spiral configuration with one fuel pin having a l" wide crack.

Fuel s

i i

pins other than the corner pins had only minor defects.

3.

I discussed the above matter with Technical Review personnel and a meeting is scheduled for 1:00 p.m. July I with the Core Performance Branch to further discuss this topic. The principal concern is whether a generic proble.n may exist since the fuel pin failure was primarfly confined to the corner fuel pins.

(There are 266 7 x 7 fuel assemblies of identical desi n L

presently installed in the Honticello core which are scheduled to be replaced by 8 x 8 fuel assemblies in October 1975.)

FutIN -UP ACTION A conference call has been scheduled for 2:30 p.m. July 1 to discuss this matter further with NSP.

Wo members from the Core Performance Dranch will visit the Monticello facility to examine the irradiated fuel and participate in further discussions, d( appropriate.

Management will be kept advised of any significant developnents on this subject.

g g

jut. 011975 -

E.C. %cA0g

,,,,,c,*

RL 0RB #2 Ecttholor ew C. Buckley

~

~

~"""

i g t, Operatin; ' Reactors" Brash ~i2" BCBuckley:ah Diiision of Roactor. Li censing.

.v...*

I 7/ / /75 o.vi.

Fone AIC.318 (Rev. 9 53) AICM 0240 8 u. s. novE RN A.SNT PRINTING OPPICR4 9994 888-184 l

9212070449 750701 l

PDR ADOCK 05000263 l

p PDR

- I i

i 2

July 1, 1975 j

Dennis I..

Ziemann 2

1 r

I cc B. Rusche E. Case i /.

A. Giambusso R. Boyd R. lleineman i

i D. Eisenhut i

D. Ross j

M. Siegel i

R. Mcycr M. Tokar V. Moore R. DcYoung D. Skovholt D. Muller i

R. Denise i

l K. Coller i

s 4

j e

6 P

l l

1 9

4 m

',.,,wy,,,F

. ' -,., _,.h,

..-,_,m.m..,.,,_,,.w_._.,_,,,y.,

ms,

,..rm,,e.-,,,,%.%..

g..,+-

., ;.. - E, _

.-.a_,,,,,,-..+-

,.,v,L,,--,~.,.-c