ML20128C910

From kanterella
Jump to navigation Jump to search
Forwards Request for Addl Info Re Air Quality Std for Svc Air Sys Changed in FSAR Amends 17/18
ML20128C910
Person / Time
Site: Perry  FirstEnergy icon.png
Issue date: 06/26/1985
From: Youngblood B
Office of Nuclear Reactor Regulation
To: Edelman M
CLEVELAND ELECTRIC ILLUMINATING CO.
References
NUDOCS 8507030706
Download: ML20128C910 (4)


Text

. .

Docket Nos.: 50-440 and 50-441 Mr. Murray R. Edelman, Vice President Nuclear Operations Group The Cleveland Electric Illuminating Company P. O. Box 5000 Cleveland, Ohio 44101

Dear Mr. Edelman:

Subject:

Request for Additional Information Regarding the Air Quality Standard for the Service Air System Changed in FSAR Amendments 17/18 - Perry Nuclear Power Plant (Units 1 and 2)

On the basis of its review of FSAR Amendment 17 ard 18, the staff has identified the need for the enclosed additional information. The information required con-cerns the basis upon which the air quality standard for the service air systems has been changed from 3 to 40 microns for maximum allowable particle size.

Please advise the Perry Project Manager when we may expect to receive your reply within 5 days after receipt of this letter.

Sincerely, B. J. Youngblood, Chief Licensing Branch No. 1 Division of Licensing

Enclosure:

As stated ,

cc: See next page DISTRIBUTION: '

Decket File BGrimes NRC PDR ^ EJordan Local PDR LSRubenstein PRC System ODParr,ASB/DSI NSIC JWilson, ASB/DSI LB#1 R/F JRaval,ASB/DSI MRushbrook JStefano OELD CRS(16)

/>JPartlow

/ 8

~ 7% . 1/DL LBf1/DL JStefano/mac BJYoyngbl od d /Lg/85 G /p /85 km A

O A OM fM40 PDR

M 2 61985 Mr. Murray R. Edelman Perry Nuclear Power Plant The Cleveland Electric Units 1 and 2 Illuminating Company cc:

Jay Silberg, Esq. Mr. Larry 0. Beck Shaw, Pittman, & Trowbridge The Cleveland Electric 1800 M Street, N. W. Illuminating Company Washington, D. C. 20006 P. O. Box 97 E-210 Perry, Ohio 44081 Donald H. Hauser, Esq.

The Cleveland Electric Illuminating Company P. O. Box 5000 Cleveland, Ohio 44101 Resident Inspector's Office U. S. Nuclear Regulatory Commission Parmly at Center Road Perry, Ohio 44081 Regional Administrator, Region III U. S. Nuclear Regulatory Commission 799 Roosevelt Road Glen Ellyn, Illinois 60137 Donald T. Ezzone, Esq.

Assistant Prosecuting Attorney 105 Main Street Lake County Administration Center Painesville, Ohio 44077 J

' Ms. Sue Hiatt OCRE Interim Representative 8275 Munson Mentor, Ohio 44060

- Terry J. Lodge, Esq.

618 N. Michigan Street Suite 105 Toledo, Ohio 43624 John G. Cardinal, Esq.

Prosecuting Attorney Ashtabula County Courthouse Jefferson, Ohio 44047

ENCLOSURE AUXILIARY SYSTEMS BRANCH REQUEST FOR ADDITIONAL INFORMATION PERRY NUCLEAR POWER PLANTS, UNITS 1 AND 2 DOCKET NOS. 50-440 AND 50-441 Process Auxiliaries- Compressed Air Systems 1.

FSAR Section 9.3.1, as revised per previous amendment (s) issued, including Amendment 17 and FSAR Section 6.8.4, as revised under Amendment 18 states the following:

,. a.

"The system meets the design guidelines of ANSI Standard MC-11-1 (ISA-S7.3) with the exception that the maximum allowable particle size for air to safety related equipment is 40 microns."

b.

"During operation, instrument air quality will be tested, on an annual basis, at the filter discharge for dewpoint and particulate contamina-tion. The required air quality to safety related components supplied from this system is: zero particulates larger than 40 microns, dewpoint less than '40'F. On failure to meet acceptable air quality, branch lines will be tested to determine the extent of the problem and corrective action needed."

c.

" Air quality will be tested on a yearly basis downstream of the purifier

-e

, package for dewpoint and particulate contamination. The required air

' quality to safety-related components supplied from this system is: zero particulates larger than 40 microns and a dewpoint less than ~40*F."

In order for us to evaluate these statements provide the following information:

1.

Provide the basis for your system design deviation from three(3) micron ANSI, MC-11-1 limit to 40 microns proposed limit for the air quality.

2 b.

Provide verification that the involved safety related equipment will perform its intended functions utilizing the proposed 40 microns .

instrument air quality. , Provide listing of the safety related equipment and corresponding manufacture.'s recommended air quality.

c.

Verify that the air quality, at the _ INLET of the involve safety related equipment, will meet the proposed 40 micron limit in order to perform its intended function. Provide procedures and/or

~

technical specifications to test, detect, and correct the degradation of the proposed instrument air quality at the INLET of the involved safety related equipment in order to assure its

_ intended operation.

we s

- - - ~ --, ,, , . - - - , _ , - - - - - - - . - , , - . , - . , , . - - - - - - - - - - - - - - - - - - - -y-,,- -., + . - ------