,n.

y.

l

,..CooperSeeeemer

e

.-. _. _ _ __, Products DMelon 150 Lincoln Avenue L Grove City, PA 16127 1898 412 458-8000 :

F W

iJanuary 28,1993:

COOPERL Our Ref; OCG-92GO Document Control Desk-U.S. Nuclear Regulatory Commission Washington, D,C. 20555

Subject:

10 CFR Part 21 Steel Cylinder Heads

Dear Sir:

On December 17,1992 Cooper-Bessernor Products Division, a division of Cooper -

Industries issued a final report (our Rel. OCG-9218) concerning a defect on cast steel cylinder heads.

in addition to the part numbers identified, one additional pa.'t number has been discovered, 1 A 7680, which had been supplied to Southem Califomia Edison. A copy of this report is '

being sent to the affected utility.

If you have any questions regarding this issue, please contact. John R. Schneider, Manager, Quality Assurance at 412-458-3434 or Ron G.-Billig,-Supervisor of Enterprise Engineering at 412-458 3584.

Si, erely,

' Jb n R. Schneider

' Manager, Quality Assurance and

Nuclear Operations JRS/kil Mr. Walter Haass.

- cc-A.- D. Gillette - CES!GC U. S. Nuclear Regulatory Commisslon R. G. Billig CES/GC -

-One White Flint North.

' K.- E. Tasik - CES/GC Mallstop 9D4

-J. A. Manno - CES/ Alameda Washington, DC f 20555

' B. C. Guntrum - CES/ Alameda R. L. Nimmo - CES/ Alameda' Southem Califamla Edison Co.

Lee Duck - CES/ Alan, eda -

San Onofre. Nuclear Generating Station--

R. A. Johnse CES/ Alameda P, Oc Box 128 --

San Clemente, CA192672 =

< M,n Attn: Manager, Nuclaar Osersight Div.

2040007 9 acing

g_

- ADOCK 05000206' PDR cm,.w. serpet - e P.on? --

7 s+

.