__ _ _ _ _ _ _ _ _ _ _

FE8 9 ms

=-

D Derre11 G. Eisenhut, Assistant Director for Operational Technology, DOR i

TECilNICAL ASSISTANCE REQUEST NO. ORB-2-212 Plant Naae:

Monticello Nuclear Generatine, Station (Possible generic issue for all BWu's)

Docket No:

5053' Project Han ger:

Richard R. Snalder (27403)

Operational Technology Review Dranch:

Reactor Safety Branch Requested Conpletion Date:

l' arch 10, 1970 r,cscription of Request:

Backcround By letter dated.ianuary 26, 1976, Northern Stat.s Power Company (NSP) proposed a change to the Technical Specifications for Monticello to reduce the frequency for exercising pontrol; rods from one week to one month. The licensee clair.s that :

(1) 25,000 such tests at Monticello without a single failure justifies a reduction in frequency of these tests; (2) recent analytical studies reveal that weekly tests result in fuel damage and increased offgas releases; and (3) the probability of two or more rods being ino).erable will be less than 10-6 even at the monthly testing interval.

Request for Assistance:

i Your review of the.Tanuary 26, 1976 NSP sulcittal is requested with specific h

consideration itiven to the possible multi-inceted genric issue.

Note'that the licensee has treated the related collet housing cracking problem in his sulnittal and believes that inspections for the start of cract propagation not rod exercising provides the assurance that collet housinc cracks will not become a problen.

Coordination with NSP or the vendor (CE) may be necessary during your review of this issue.

It is requested that you work closely with the operatinn Ecactors contact during your investigation. Your final report should judge the acceptability of the NSP submittal as it could apply to all INR's.

Nnal signed by Dennis

.' idSM", Chief DISTRIBm0N Egs operating Reactors Branch #2 j

D ivisi n f Operating Reactors l

ORB #2 Reading rnelosure:

NSP License Amendment 'icquest

/

dated,innuary 26, 1976

/ k g

,,,,g p RB #2 ORERN#2 M..

RSnaider:ro DLZiemann 2/ 9 /76 2/. 4/.76 pars >

. 4:..

Form ABC41B (Rev. 9-58) AECM 0240 it we sa sovsanusut enterine opricas nova.sss.ies 9212040348 760209 PDR ADUCK 0500G263 P

PDR

s

. s o 2-4 cc:

i it. L; Baer V. Stello i

K. R. Coller T. J. Ca v ' 'er

n. P. SL:. der

'N, i' 51. Digge i

l i

l I

l l

{

l t

f t

l l

(

l L

l l

3 09 9BC S >

- * * = ~ ~ ~ - - * ~ ~ * " ~ '

sunwansa k cats >

Form AEC 388 (Rev. 9 53) AECM 0240

  • v. e4 eovsaureat Pasarine omescas sev4.sas.t ee