U.S. NUCLEAR REGULATORY COMMISSION MATERIALS LICENSE Amendment No. 01 Pursuant to the Atomic Energy Act of 1954, as amended, the Energy Reorganization Act of 1974 (Public Law 93-438), and Title 10, 1
Code of Federal Regulations, Chapter 1, Parts 30,31,32,33,34,35,40 and 70, and in reliance on statements and representations 4
p;
,3 heretofore made by the licensee, a license is hereby issued authorizing the licensee to receive, acquire, possess, and transfer byproduct, f
- s source, and special nuclear material designated below; to use such material for the purpose (s) and at the place (s) designated below; to d
5 deliver or transfer such material to persons authorized to receive it in accordance with the regulations of the applicable Part(s). This 9
license shall be deemed to contain the conditions specified in Section 183 of the Atomic Energy Act of 1954, as amended, and is f
subject to all applicable rules, regulations and orders of the Nuclear Regulatory Commission now or hereafter in effect and to any lq conditions specified below.
88g "I' { {
n I1.
~~~~
~ ""
Licensee In accordance with letter dated January 9, 1985, Princeton Gamma-Tech, Inc.
- 3. License number SNM-1869 is amended in it entirety to read as follows:
2.
P. O. Box 641 Princeton, New Jersey 08540
- 4. Expiration date June 30, 1990
- 5. Docket or 070-02915 dj Reference No.
- 6. Byproduct, source, and/or
- 7. Chemical and/or physical
- 8. Maximum amount that licensee _
p; spcial nuclear material form may possess at any one time under this license A. Plutonium 239 A. Sealed neutron source A. 16 grams (NUMEC-Model A)
E!
B. Plutonium 238 B. Sealed source B. I milligram E
(Amersham Model PPC) 3 s
3 9.
Authorized use W
q
- s A. and B.
For use in research and development and in the testing of radiation detectors.
5 5
k l
CONDITIONS 4
4
- 10. Licensed material shall be used only at the licensee's facility located on Route 518, j
East of Route 206 in Rocky Hill, New Jersey.
- 11. The licensee shall comply with the provisions of Title 10, Chapter 1, Code of Federal
('
Regulations, Part 19, " Notices, Instructions, and Reports to Workers; Inspections" and Part 20, " Standards for Protection Against Radiation."
12.
Licensed material shall be used by, or under the supervision of, Joseph A. Baicker, Joseph H. Dudek, Jr. or Micha Harchol.
i 13.
A.
(1)
Each sealed source containing licensed material, other than Hydrogen 3, f
with a half-life greater than thirty days and in any form other than gas shall be tested for leakage and/or contamination at intervals not to exceed six months.
In the absence of a certificate from a transferor irdicating that a test has been made within six months prior to the transfer, a sealed source received from another person shall not be put into use until tested.
I (2) Notwithstanding the periodic leak test required by this condition, any licensed sealed source is exempt from such leak tests when the source contains 100 microcuries or less of beta and/or gamma emitting material or 10 microcuries or less of alpha emitting material.
5)
E!
Y hI 8507030070 850613 l'"
ye.nnoncA m smann ansramirracenaisianensnaranmnrrar.cre U. S..
EAR REGULATORY COMMISSION NR Form 374 A PACE 2
OF 2
paces Lie;nse nurnber H
MATERIALS LICENSE SNM-1869 3
SUPPLEMENTARY SHEET d
.1 070-02915 g.
1 3
Amendment No. 01 6
1 pe l
(13. continued)
CONDITIONS El h
-q (3) The periodic leak test required by this condition does not apply to sealed gj sources that are stored and not being used. The sources excepted from this p
5 test shall be tested for leakage prior to any use or transfer to another lF) 5 person unless they have been leak tested within six months prior to the El l
date of use or transfer.
P 4
q B.
The test shall be capable of detecting the presence of 0.005 microcurie of 4
radioactive material on the test sample. The test sample shall be taken from 4
the sealed source or from the. surface'slif the device in which the sealed source 5) d is permanently mounted or itofed'on which'6ne..'might expect contamination to El l l
accumulate. Records.of~ leak test results shall-be-kept in units of microcuries gi q
and maintained for inipection by the Commission. If gl
- d O
A ri l
-g C.
If the test reveal,s'the presence of 0.005 microcurie or more of removable pli l
see shall immediately withdrawTthe sealed source from al contamination,.the licenB'be decontaminated and repaired or to be disposed of in E
use and shall cau'se it-t'
- 3j accordancewith'Commissi6dyfegulation_s.
A, report shall be filed within 5 days j
of the test with the U. (S Anuclear 1 Regulatory. Commission,. Region I, 631 Park j
Avcnue, King.of PrussiaFPqnjisflvania 19406,: describing the equipment involved, p) g the test results, and the: corrective action taken.
p d
M
,M D M 7 4 6.'<
2 El
- 3 D.
The licensee.is authorfzed-to'collectlleak test samples in~accordance with the 1
3 procedures described 11n'the licen'se 'slettir for analysis by Siemens i
Gammasonics. Alternai;i'vely, leak test' simples may be collected and/or analyzed l
l by other personsispecificalJyladthorizedjy% ~
ithe Commission or an Agreement State l
to perform such Yervice5'. %
$UN l['I 4
d Glljh Mi
&,N q
0 5
- 14. Sealed sources containing' licensed material shall n'ot be^ opened.
l 15.
Q
~
4* '
Except for plutonium contained in a medical device des'1gned for individual human 4
g application, no plutonium, regardless of form,,shall be delivered to a carrier for g
l g
shipment by air transport or transported Tn 'an, aircraft by the licensee except in p
4 packages the design of which the NRC has specifically approved for transport of p
plutonium by air.
Q il G
p di 16 d
f
. Except as specifically provided otherwise by this licen i
d w{ th statements, representations, and procedures contained in application dated g
JMuary 9, 1985. The Nuclear Regulatory Commission's regulations shall govern the H
licensee's statements in applications or letters, unless the statements are more 4
restrictive than the regulations.
- M A
A
- 1 N
- h For the U.S. Nuclear Regulatory Commission fB
!=
q Original Signed By:
)
!i Date JUN 131985 By John D. Kinneman l
j Nuclear Materials Safety and l
Safeguards Branch, Region I l
j
.g King of Prussia, Pennsylvania 19406 p