ML20128A676

From kanterella
Jump to navigation Jump to search
Forwards Insp Repts 50-348/92-35 & 50-364/92-35 on 921208- 930108 & Nov.Violation of Concern Because Site Lubrication Oils Were Procured Commercial Grade & Used in safety-related Applications W/O Assurance of Suitability
Date released: 05/21/2020 Download: ML20128A676


Insp Repts 50-348/92-35 & 50-364/92-35 on 921208-930108. Violations Noted.Major Areas Inspected:Operations,Maint, Surveillance,Licensee self-assessment,emergency Preparedness & Action on Other Previous Insp Findings
ML20128A721
Person / Time
Site: Farley Southern Nuclear icon.png
Issue date: 01/15/1993
From: Cantrell F, Maxwell G, Morgan M
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To:
References
Download: ML20128A721 (11)
Notice of Violation from Insp on 921208-930108.Violation Noted:Lubricating Oil Was Not Properly Controlled in That Oil Other than That Specified in Applicable Equipment Lubrication & Vendor Manuals Used in Listed Equipment
ML20128A682
Person / Time
Site: Farley Southern Nuclear icon.png
Issue date: 01/26/1993
From:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To:
References
Download: ML20128A682 (1)
Forwards Insp Repts 50-348/92-35 & 50-364/92-35 on 921208- 930108 & Nov.Violation of Concern Because Site Lubrication Oils Were Procured Commercial Grade & Used in safety-related Applications W/O Assurance of Suitability
ML20128A671
Person / Time
Site: Farley Southern Nuclear icon.png
Issue date: 01/26/1993
From: Merschoff E
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To: HAIRSTON W G
SOUTHERN NUCLEAR OPERATING CO.
References
Download: ML20128A671 (3)