ML20128A407

From kanterella
Jump to navigation Jump to search
Forwards Insp Repts 50-327/92-36 & 50-328/92-36 on 921129- 930102 & Nov.Violation Involved Inadequate Procedures & Failure to Follow Procedures,Which Resulted in Mispositioning of Throttle Valves
Date released: 05/21/2020 Download: ML20128A407


Insp Repts 50-327/92-36 & 50-328/92-36 on 921129-930102. Violations Noted.Major Areas Inspected:Operations,Plant Maint & Surveillance,Evaluation of Licensee self-assessment Capability,Ler Closeout & Followup on Previous Findings
ML20128A458
Person / Time
Site: Sequoyah Tennessee Valley Authority icon.png
Issue date: 01/12/1993
From: Holland W, Kellogg P
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To:
References
Download: ML20128A458 (33)
Notice of Violation from Insp on 921129-930102.Violations Noted:Procedure S0I-82.2 Not Followed & Periodic Instruction 0-PI-OPS-000-006.0 Inadequate
ML20128A430
Person / Time
Site: Sequoyah Tennessee Valley Authority icon.png
Issue date: 01/15/1993
From:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To:
References
Download: ML20128A430 (2)
Forwards Insp Repts 50-327/92-36 & 50-328/92-36 on 921129- 930102 & Nov.Violation Involved Inadequate Procedures & Failure to Follow Procedures,Which Resulted in Mispositioning of Throttle Valves
ML20128A403
Person / Time
Site: Sequoyah Tennessee Valley Authority icon.png
Issue date: 01/15/1993
From: Merschoff E
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To: MEDFORD M O
TENNESSEE VALLEY AUTHORITY
References
Download: ML20128A403 (4)