Forwards Documents to Ensure Compilation of Complete Regulatory History of Rulemaking for Minor Mods to Nuclear Power Reactor Event Reporting Requirements (10CFR50.72 & 73) Final Rule
ML20127P401
Person / Time
Issue date: 01/29/1993
From: Walter Leschek
NRC OFFICE FOR ANALYSIS & EVALUATION OF OPERATIONAL DATA (AEOD)
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML19341G201 List:
References
FRN-57FR41378, RULE-PR-50 AD03-2-001, AD3-2-1, NUDOCS 9302010279
Download: ML20127P401 (6)


Text

- - _ _ _ _ _ _ _ - _ _ _ _ _ _ _ _ _ _ _ _ _ _

*om

[s n

'o UNIT ED STATES l

[3 Q

NUCLEAR PEGULATORY COMMISSION WASWN' MON, D C. M5$

j AD03-2

"%, j,

+'#

January 29, 1993 ll0TE TO:

Document Ccntrol Desk (Pl White flint)

FROM:

Walter C. Leschek Data Management Section Trends and Patterns Analysis Branch Division of Safety Programs Office for Analysis and Evaluation of Operational Data

SUBJECT:

REGULATORY HISTORY - MINOR MODIFICATIONS TO NUCLEAR POWER REACTOR EVENT REPORTING REQUIREMENTS -- 10 CFR 50.72 AND 50.73 (Final Rule; 57FR41378)

In compliance with procedures established by the Executive Director of Operations in his memorandum of April 5,1985 documentation is enclosed to ensure the compilation of a complete regulatory history of rulemaking for Minor Modifications to Nuclear Power Reactor Event Reporting Requirements

- 10 CFR 50.72 and 50.73 (Final Rule).

Documents destined for the Public Document Room are marked "PDR" in the upper rignt-hand corner, and are arranged chronologically in ascending order; documents destined for the Central Files are marked "CF" in the upper right-hand corner, and are also arranged chronologically in ascending order.

The CF docarc.ents are grouped after the PDR documents.

All of these documents are also marked "A003-2" in the upper right-hand corner, to designate Final Rule.

An indexed listing of the enclosed dccuments is attached to this note.

Ifaspf,$lk Walter C. Leschek Data Management Section Trends and Patterns Ana'ysis Branch Division of Safety Programs Office for Analysis and Evaluation of Operational Data cc:

R. Tr pathi i

TPAB R/F

)

9302C10279 930129 PDR PR 50 57FR41378 PDR

. ~..

l-~,

!Page No.

1 Final Rule Public Document Room

'01/28/93 RULEMAKING TO MODIFY OPERATING POWER REACTOR

-REPORTING REQUIREMENTS:

10 CFR 50.72 and 10 CFR 50.73 i

'DATE-DOC _ TYPE TO FROM SUBJECT ACTION 06/29/92 PRESS RELEASE Fublic Nuclear NRC PROPOSES Notifies Regulatory TO AMEND pub]ic of Commission REGULATIONS proposed TO REDUCE minor CERTAIN EVENT rulemaking to -

REPORTING' modify REQUIREMENTS operating reactor event reporting i

requirements under 10 CFR i

50.72.and

-j 50.73.

08/19/92 MEMORANDUM Directors:

Edward L.

IMPLEMENTATIO Request to NRR, RES,

Jordan, N OF expedite ADM,LIRM,.and Director REGULATORY concurrence OE. Martin G.

AEOD REFORM -

for

Halsch, FINAL RULE ON rulemaking.

Deputy MODIFICATION General TO OPERATING Counsel REACTOR EVENT REPORTING REQUIREMENTS 10 CFR 50.72 AND 50.73 09/10/92 Federal Notice to-Nuclear Final Rule:

Publication Register Pub. Public Regulatory Minor.

of Final Rule-Commission Modifications in 57 FR to Nuclear

41378, Power Reactor Event

. Reporting Requirements

-- 10 CFR-50.72 and 50.73

'h

i

- Page. lio.

-2 Final' Rule Public Document Room 01/28/93 RULEMAKING TO MODIFY OPERATING' POWER ~ REACTOR' REPORTING REQUIREMENTS:

10 CFR 50.72 and 10 CFR 50.73 DATE DOC TYPE TO FROM SUBJECT ACTION 09/28/92 MEMORANDUM Patricia G.

Edward L.

QUARTERLY Notice that

Norry, Jordan, UPDATE OF final rule Director Director REGUALTORY modifying.the 1

-Office of Office for AGENDA ENTRY 10-afr'50.72 1

Administratio Analysis and and 50.73-n Evaluation of event-Operational reporting Data requirements.

was published-on September 10, 1992 (FR 41378) i I

l 4

I i

I 1

-1

s...

-1 Page_No.

1 Final Rule Central File

.01/28/93 RULE!iAKIMG TO MODIFY OPERATING POWER REACTOR REPORTING REQUIREMENTS:

10 CFR 50.72 and 10 CFR 50.73 DATE DOC _ TYPE TO I' ROM.

SUBJECT ACTION

-07/01/92 MEMORANDUM Patricia G.

Edward L.

QUARTERLY Encloses

Norry, Jordan, UPDATE OF THE AEOD's input Director Director REGULATORY for the Office of Office for

. AGENDA regulatory

)

Admisistratio Analysis and agenda entry.-

n Evaluation of

.l Operational Data 1

07/02/92 MEMORANDUM Emile L.

Raji FEDERAL Submits copy Julian, SECY

Tripathi, REGISTER of proposed AEOD NOTICE ON rule as l

MINOR published in RULEMAKING TO the Federal MODIFY EVENT Register of REPORTING June 26, 1992 REQUIREMENTS (57 FR

-- 10 CFR 28643).

50.72 AND I

50.73 l

I

^

l i

l l

L a

w r.,.~~-

g'

__i9De3 vt j PM

\\

/,a n.,5 UNITED STATES (R.af&.%

NUCLEAR REGULATORY COMMISSION (W*..M*/

Office of Public Affairs Wastlington, D.C. 20S55 No.

92-9 POR IMMEDIATE RELEASE Tel.

301-504-2240 (Monday, June 29, 1960)

/992 NRC PROPOSES T3 AMEND REGULATIONS To REDUCE CERTAIN EVENT REPOPTING REQUIREMENTS The Nuclear Regulatory Commionion in proposing to amond its r-regulations to make minor modifications to the current -nuclear power roactor ovent reporting requirements.

The proposed amendmants would deletu ruperting roq61romonta for a limitad sat af avants that havn hoon datermined to ha of little or no anfoty significanca and would reduce tho industry's reporting burdon and the NRC's response burden in event review and annosament.

The NRC ataff's reviews of operating arporianco and the pattnrns of licenseon' reporting of operating events for the past anven years bave indicated that reports on some of thoso events are not neceaanry for the NRC to perform its anfoty mission.

In particular, the staff han determined that invalid actuation, isolation or realignment of a limited set of engincorod safoty featuroa (ESFn) or their equivalent ayatumn, subsystema or components are of little or no aafety significance.

However, those avonta currently are reportablo.

- As proposed, the following typen of events would be doloted from the existing reporting requiremonto:

(1) ovents in which an invalid ESF or reactor prctaction nyatom (RPS) actuation occurs when the ayatom already is properly removed from service if all requiremonta of plant procedures for removing equipment from service have been met; (2) ovents in which an invalid ESF or RPS actuation occura after the safory function already han boon completed; (3) ovants in which an invalid actuation, isolation or realignment of only the roactor water clean-up (RWCU) syntom or specified vcnt110 tion systems occurs.

Invalid actuations that involve other ESFa, not specifically prcponod for exclusion (such an amargency core cooling system jaolations or actuations, containment isolation valve closuren l

2 that affect cooling systems, main atoam flow or essential support ayatoma containment spray actuation and residual heat removal oystem isolations) would continue to be reportable.

Licensoos vould continue to submit Licanaco Event Reporta if a deficiency or advoran conditions associated with any of the invalid ESP actuation of the reactor water clean-up ayaten or the ventilation nyatoms natisfy any other reportability critoria 3n the NRC's regulations.

Written commenta ot the propnand amendmenta to Part 50 of the Commionion's regulations should be received by July 27.

They should be addressed to the Socratary of the Connianion, Nuclear Regulatory Commicsion, Washington, D.C.

20555, Attention:

Docketing and Service Branch.

e R

. - - -. -. _ _ - - ~ _ _ _. - - -

p

_