r

94

a-

.

,

MAY 8

1985

Georgia Power Company

ATTN:' Mr. R. J. Kelly

Executive Vice President

-P. O. Box 4545

Atlanta, GA 30302

Gentlemen:

SUBJECT: -REPORT NOS. 50-424/85-18 AND 50-425/85-18

This letter refers to the technical meeting held at your request in the NRC

Region II Office on May 1,1985. This meeting concerned activities authorized

by NRC Construction Permit Nos. CPPR-108 and CPPR-109 for the Vogtle facility.

_

The meeting provided Georgia Power Company (GPC) an opportunity to demonstrate

the ability of their ultrasonic examination procedure and equipment to detect,

locate, and size actual crack flaws propagating from the pipe inside diameter in

centrifugally cast stainless steel as discussed in the enclosed report.

It is our opinion that this meeting was informative and beneficial to both NRC

and GPC because of the exchange of information concerning inspection of cast

stainless steel.

In accordance with 10 CFR 2.790(a), a copy of this letter and the enclosure will

be placed in NRC's Public Document Room unless you notify this office by

telephone within 10 days of the date of this letter and submit written applica-

tion to withhold information contained therein within 30 days-of the date of the

letter.

Such application must be consistent with the requirements of

2.790(b)(1).

j

Should you have any questions concerning this matter, we will be pleased to

i

discuss them.

Sincerely,

Virgil L. Brownlee, Chief

Reactor Projects Branch 2

Division of Reactar Projects

Enclosure:

Inspection Report No. 50-424/85-18

and 50-425/85-18

cc w/ enc 1:

(See page 2)

8507020230 850508

PDR

ADOCK 05000424

G

PDR

'EEO/

J

o

,

Georgia Power Company

2

pg4y g

tgg

cc w/ enc 1:

R. E. Conway, Senior Vice Presider.t

Nuclear Power

'

D. O. Foster, Vice President

and General Manager Vogtle Project

H. H. Gregory, III, General

Manager, Vogtle Nuclear Construction

G. Bockhold, Jr., Vogtle

Plant Manager

L. T. Gucwa, Chief

Nuclear Engineer

Ruble A. Thomas,

Vice President-Licensing Vogtle

Project

'-

Ed Groover, Quality

Assurance Site Manager

C. W. Hayes, QA Manager

J. T. Beckham, Vice President

& General Manager - Operations

J. A. Bailey, Project Licensing

Manager

George F. Trowbridge, Esq.

Shaw, Pittman, Potts and Trowbridge

Bruce W. Churchill, Esq.

Shaw, Pittman, Potts and Trowbridge

Ernest L. Blake, Jr. , Esq.

Shaw, Pittman, Potts and Trowbridge

James E. Joiner, Troutman, Sanders,

Lockerman and Ashmore

James G. Ledbetter, Commissioner

Department of Human Resources

Charles H. Badger, Office of

Planning and Budget, Management

Review Division

Deppish Kirkland, III, Counsel

Office of the Consumer's Utility

Council

Douglas C. Teper, Georgians Against

Nuclea- Energy

Laurie Fowler, Legal Environmental

Assistance Foundation

Tim Johnson, Executive Director

Educational Campaign for a Prosperous

Georgia

Morton B. Margulies, Esq., Chairman

Administrative Judge, Atomic Safety

and Licensing Board Panel

Dr. Oscar H. Paris, Administrative Judge

Atomic Safety and Licensing Board Panel

Gustave A. Linenberger, Jr. , Administrative

Judge, Atomic Safety and Licensing Board

Panel

bec w/ enc 1:

(See page 3)

_

.

,

Georgia Power Company

3

gyg

bec w/ encl:

E. Reise, ELD

M. Sinkule,MTEB, NRR

RII

M...R.

Hum,

NRC Resident Inspector

Document Control Desk

State of Georgia

,-

I

RIL .

kI

a

Q%K

R ewsome:bhg

Blaki-

ARHerdt

MS nkule

5/4 /85

5/'//85

5/1/85

5/ l/85

1