r
-- - - -- - - - ------ ---- === ----warsenacanemwmunammrwarmaramrmrearnnsnvaminany !
Is"aE CERTIFICATE OF COMPLIANCE so ca "
FZR RADil' ACTIVE MATERIALS PACKA*ES I a CERTIFICATE NUMBER
. REVISION NUMBER C PACKAGE ICENTiFICATION NUMBER d PAGE NUMBER e TOTAL NUMBER PAGES 9141 2
USA /9141/B(U) 1 2
2 PAEAMBut I
- a. This certificate is issued to certify that the packaging and contents described in item $ below. meets the applicause safety standards set forth in Title 10, Code of Federal Regulations. Part 71. " Packaging of Radioactive Materials for Transport and Transportation of Radioactive Material Unde Certain Conditions?
b This certificate does not relieve the consignor from compliance with any requirement of the regulations of the U S. Department of Transportation or other I
applicable regulatory agencies. Including the government of any country through or into which the package will be transported.
4
! ' 'a"PEP*A'ES^e'v'E*a'S'S'ffs",' ' ' **" ^**'*."'T ?tE fNo'Io'E0'JCAT ON""W
^'
e EO P CATION Technical Operations, Inc.
Technical Operations, Inc. application dated Northwest Industrial Park February 1,1980.
i Burlington, MA 01803 7j,934) ip i
c DOCMET NUMBER 4 CONDITIONS This certificate is conditional upon fulfillmg the requirements of 10 CFR Part 71, as applicable, and the conditions specified below i
5 (a)
Packaging J
nj l
(1) Model No.:
900 (2)
Description lE E
A stainless steel encased, uranium shielded radiographic device.
The shipping container is 13.0 inches long, 7.7 inches high and 5.3 inches i
wide.
The radioactive source assembly is housed inside a tungsten 1l source tube. The source tube is surrounded by depleted uranium metal ig for shielding.
The depleted uranium shield assembly is encased in a lp stainless steel housing.
The void space between the uranium shield E;
assembly and stainless steel housing is filled with a castable rigid
,E:
polyurethane foam.
The gross weight of the container is 44.0 pounds.
{
!g.
(3)
Drawings ll l
l The packaging is constructed in accordance with the following Technical lN Operations, Inc. Drawing Nos. 90090, Sheets 1, 2, 3, and 4 of 4, i
Rev. 0; and 90091, Sheets 1 of 1, Rev. O.
i i
I i
!D i
lE
.R
'E i
E
.R l
IR n
i 18 E
i j
8505230552 850509 i
C PDR 1
l 8
i i
I m.mmmmmmy.mmmm mmmmm,-m--m.------
---.c..y e wmm,_
MMMMMM M MMMMMM M MM M MM M MMMMMMM M M M MMMMMMMM MM1EGELMM&M M Q
C:NDITl:NS (continuid) e Page 2 - Certificate No. 9141 - Revision No. 2 - Docket No. 71-9141 t
i 5.
(b) Contents l
(1) Type and form of material i
Iridium 192 as sealed sources which meet the requirements of special f
l fom radioactive material.
(2) Maximum quantity of material per package g
f 120 curies
'M i
6.
The source shall be secured in the shielded position of the packaging by the,
g source assembly. The source assembly must be fabricated of materials capable of resisting a -1475*F fire environment for one-half hour and naintaining their 4
~
3j i
positioning function.,The source assembly must engage the locking device. The source assembly must be of sufficient length and diameter to provide positive g
i l
positioning of the. source _within the depleted uranium shield assembly.
g 7.
The name plate shall be fabridated of materials capable of resisting the fire test of 10 CFR,Part 71 and maintaining their legibility.
l l0.
The package authorized by this certificate. is _hereby approved for use under the general license provisions of 10 CFR 571.12.-
l l
9.
Expiration date: 'May 31,'1990.
l i
REFERENCE l
Technical Operations, Inc. application dated February 1,1980.
E FOR THE U.S. NUCLEAR REGULATORY COMrilSSION
!E llE sL Charles
. fiacDonald, Chief I
{!g i
Transportation Certification Branch Division of Fuel Cycle and flaterial Safety, Nf1SS gy0& g Da te -
'E T
l
)W j$
ll!,
le@
{
l l
m
./
UNITED STATES y ),"v. (/( o NUCLEAR REGULATORY COMMISSION
- ;, J '#/c,E WASHINGTON, D. C. 20555
%, ~ Q /
Transportation Certification Branch Ap3roval Record Model
- 10. 900 Packaging Docket No. 71-9141 By application dated March 19, 1985, Technical Operations, Incorporated, requested renewal of Certificate of Compliance No. 9141.
No changes have been requested or made to the package since approval of Technical Operations' application dated February 1,1980.
The staff concludes that the statements of the original application dated February 1,1980, satisfy. the requirement for renewal of the certificate of compliance, b
k Charles E. MacDonald, Chief Transportation Certification Branch Division of Fuel Cycle and Material Safety, NMSS MAY0$f4 Date:
.