Text
m - 9 MI Distribution: w/encls Docket File t
E9IE NRC PDR IE HQ' Regions (5)
State Health Official FCTC:CEy CEWilliams 71-9141 RH0degaarden GJackson REllSq g NMSS R/F ABachliB FCTC R/F g 33 Technical Operations, Inc.
AITN: Mr. John J. fiunro, III 40 North Avenue Burlington, fiA 01303 Gentlemen:
As requested by your application dated fiarch 19, 1985, enclosed is Certification of Compliance No. 9141, Revision No. 2, for the !!odel No. 900 shipping package. This certificate supersedes, in its entirety, Certificate of Compliance No. 9141 Revision No. 1, dated September 6, 1983.
Changes nade to the enclosed certificate are indicated by vertical lines in the nargin.
Those on the attached list have been registered as users of this package under the general license provisions of 10 CFR 971.12 or 49 CFR 9173.471.
This approval constitutes authority to use this package for shipment of radioactive caterial and for the package to be shipped in accordance l
with the provisions of 49 CFR 6173.471.
Sincerely, i
twisinal Signed by i
p K.MAcDONED Charles E. tiacDonald, Chief i
85 boh hkok43 Transportation Certification Branch j
PD C
PDR Division of Fuel Cycle and Material Safety, NP.SS s
Enclosure:
1.
Certificate of Conp11ance No. 9141, Rev. 2 2.
Approval Record cc w/encis:
tir. Richard R. Rawl Departrent of Transportation 4
nW A
au-= WEW illiams:adm RH0degaarden C ac onalc d5/o/)85 Of/h5,,,
05f,[/85
" ' = >
- une row us no soi uncu a24o OFFICIAL RECORD COPY
M l'odel fio. 900 Packaging USA /9141/B(U) 1 09586 Addressees: w/encls Ltr dtd:
ABC Testing ATTti: tir. C. A. Richardson 8511alnut Street Bridgewater, !!A 02324 Chicago Bridge & Iron Company ATTN: fir. R.11. Kruzic P.O. Box 40056 Houston, TX 77040 Columbia Gas Transmission Corporation ATTil: !!r Donald C. lihite P.O. Box 1273 Charleston, IN 25325 f!agnaflux Corporation ATTil: llr. Peter J. Rosauer 7300 11 Lawrence Avenue Chicago, IL 60656 Technical Operations, Inc.
ATTil:
t'r. John J. P'unro, III 40 florth Avenue Burlington, ilA 01803
"""^*5>
^">
NRC FORM 318 (10 80) NRCM 0240 OFFICIAL RECORD COPY