_

r GPU Nuclear Corporation a gn One Upper Pond Road Gu Parsippany, New Jersey 07054 201 316-7000 TELEX 136-482 Writer's Direct Dial Number-November 25, 1992 6000-92-100 C321-92-2316 U.S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, D.C.

20555 Gentlemen:

Subject:

Oystar Creek Nuclear Generating Station (0CNGS)

Docket No. 50-219 Facility Operating License No. OPR-16 "IGSCC Cast Austenitic Pump Inspection"

Reference:

GPUN Letter C321-92-2282/5000-92-3071 dated October 2, 1992, "lGSC' Examinations and Weld Overlay Repairs".

In the referenced letter, GPU Nuclear.orovided a detailed explanation as to why current refracted longitudinal wave or UT inspection methodologies would not yield meaningful results in IGSCC inspections for cast stainless steel components; specifically the reactor recirculation pumps.

In follow-up telcohone conversations with the NRC Staff on this subjact, it was agreed that visual axamination for IGSCC consistent with ASME Code Case N-481,

" Alternative Examination Requirements for Cast Austenitic Pump Casings,Section XI, Division 1",

was appropriate for the reactor recirculation pumps.

Accordingly, GPU Nuclear aarees to inspect, consistent with Code Case N-481, Item (c), those internal surfaces of the reactor recirculation pumps which are subject to possible IGSCC.

Each indivioual pump will be inspected when it is next disassembled for maintenance and access to these internal surfaces becomes available.

If a reliable and repeatable ultrasonic examination method for cast stainless steel components is developed, GPU Nuclear will reconsider performing UT inspections in lieu of the visual inspections for the reactor recirculation pumps.

jh20gggojoogg pf^\\

nn m<

I GPU Nuclear Corporation is a subsidiary of General Pubhc Utilities Corporation

{

l 4

C321-92-2316 Page 2 If you have any questions or comments on this submittal; aleast contact Mr. Michael La9c,.t, Mananer, Corporate Nuclear Licensiuq at (201) 316-7968.

Sincerely, 4

b.

. I DC%

C. A. Mascari Vice President and Director Nuclear Assurance CAM /RTZ/amk cc: Administrator, Region 1 Senior Resident inspector Oyster Creek NRC Project Manager 4

1 s