+4 DUKE POWER GOMPANY P.O. box 33180 CHAMLOTTE, N.G. 28242 HALB. TUCKER TELEPHONE vua resecouwt (704) ONS31 June 21, 1985

= = * = = "

Mr. Harold R. Denton, Director Office of Nuclear Reactor Regulation U. S. Nuclear Regulatory Commission Washington, D. C. 20555 Attention:

Ms. E. G. Adensam, Chief Licensing Branch No. 4

Subject:

Catawba Nuclear Station Docket Nos. 50-413, - 414

Dear Mr. Denton:

Please find attached our responses to NRC requests for information dated June 4, 1985 concerning Generic Letter 83-28.

These responses address Items 4.2.1 and 4.2.2 which have to do with reactor trip system reliability and trending aspects of the preventative maintenance program for reactor trip breakers.

This submittal parallels portions of our letter of May 24, 1985, in which these items were addressed for McGuire Nuclear Station. Our responses are essentially the same for both stations.

Very truly yours, k

lM pg Hal B. Tucker LTP/mjf Attachments cc:

Dr. J. Nelson Grace, Regional Administrator U. S. Nuclear Regulatory Commission Region II 101 Marietta Street, NW, Suite 2900 Atlanta, Georgia 30323 NRC Resident Inspector Catawba Nuclear Station Dr.'K. Jabbour, Project Manager Division of Licensing Office of Nuclear Regulatory Commission O

Washington, D. C. 20555 1p 8506270618 850621 PDR ADOCK O p l3 p

PM

./

Mr. Harold R. Denton, Director June 21, 1985 Page.

cc: (continued)

Palmetto Alliance 2135\\ Devine Street Columbia, South Carolina 29205 Mr. Jesse L. Riley Carolina Environmental Study Group 854 Henley Place Charlotte, North Carolina 28207 Robert Guild, Esq.

P. O. Box 12097 Charleston, South Carolina 29412 k