ML20127K698

From kanterella
Jump to navigation Jump to search
Forwards Evaluation of DSR-48 Emergency Diesel Generator Crankshafts at River Bend Station. Rept Documents & Justifies Fatigue Margin of Crankshaft for Intended Use
Date released: 05/20/2020 Download: ML20127K698


Evaluation of DSR-48 Emergency Diesel Generator Crankshafts at River Bend Station.
ML20127K708
Person / Time
Site: River Bend 
Issue date: 05/18/1985
From:
FAILURE ANALYSIS ASSOCIATES, INC.
To:
References
Download: ML20127K708 (56)
Forwards Evaluation of DSR-48 Emergency Diesel Generator Crankshafts at River Bend Station. Rept Documents & Justifies Fatigue Margin of Crankshaft for Intended Use
ML20127K695
Person / Time
Site: River Bend 
Issue date: 05/16/1985
From: Booker J
GULF STATES UTILITIES CO.
To: DENTON H R
Office of Nuclear Reactor Regulation
References
Download: ML20127K695 (1)