f p3E800 UNITf D STATES 9

$g NUCLEAR REGULATORY COMMISSION e

o REoloN IV g

,e o,

f att RYAN PLAZA onivt. suite 400 AH LINot DN,1 E XAS 760118064 g * * "

  • j' JAti I 91993 Docket Nos. 50-445 50-446 License No. NPF-87 Construction Permit No. CPPR-127 TV Electric ATTN:

W. J. Cahill, Jr., Group Vice President Nuclear Engineering and Operations Skyway Tower 400 North Olive Street, L.B. 81 Dallas, Texas 75201 Gentlemen:

SUBJECT:

TV ELECTRIC PRESENTATION TO THE NRC ON THE STATUS OF UNIT 2 This refers to the meeting, open to public observation, conducted at NRC Region IV's request at the Comanche Peak Steam Electric Station (CPSES)

Personnel Processing Center on January 7, 1993.

This meeting related to activities authorized by NRC Construction Permit No. CPPR-127 for CPSES, Unit 2, and was attended by those on the attached Attendance List.

The subjects discussed at this meeting are described in the enclosed Meeting Summary.

It is our opinion that this meeting was beneficial and has provided a better understanding of the overall status of Unit 2.

In accordance with Section 2.790 of the NRC's " Rules of Practice," Part 2, Title 10, Code of Federal Regulations, a copy of this letter will be placed in the NRC's Public Document Room.

i.

Should you have any questions concerning this matter, we will be pleased to discuss them with you.

Sincerely,

[LV l

j e

A. Bill Beach, Director Division of Reactor Projects

Enclosure:

Meeting Summary w/ attachments cc w/ enclosure:

(see next page) l 9301220104 930119 gDR ADOCK0500g5~

)

\\-

1U Electric cc w/ enclosure:

TV Electric A11N:

Roger D. Walker, Manager of Regulatory Affairs for Nuclear Engineering Organization Skyway Tower 400 North Olive Street, L.B. 81 Dallas, Texas 75201 Juanita Ellis President - CASE 1426 South Polk Street Dallas, Texas 75224 GDS Associates, Inc.

Suite 720 1850 Parkway Place Marietta, Georgia 30067-8237 10 Electric Bethesda Licensing 3 Metro Center, Suite 610 Bethesda, Maryland 20814 Jorden, Schulte, and Burchette ATIN:

William A. Burchette, Esq.

Counsel for Tex-La Electric Cooperative of Texas 1025 lhomas Jefferson St., N.W.

Washington, D.C.

20007 Newman & Holtzinger, P C.

AlTN:

Jack R. Newman, Esq.

1615 L. Street, N.W.

Suite 1000 Washington, D.C.

20036 Texas Department of Licensing & Regulation ATTH:

G. R. Bynog, Program Manager /

Chief Inspector Boiler Division P.O. Box 12157, Capitol Station Austin, Texas 78711 Honorable Dale McPherson Colmty Judge P.O. Box 851 Glen Rose, Texas 76043

p~

~ _

c l

TV Electric t i,

h r

Texas Radiation Control Program Director t

1100 kest 49th Street Austin, Texas 78756 i

Owen L. Thero, President Quality Technology Compsny Lakeview Mobile Home " ark, Lot 35 e

4}C3 C. Loop 820 South Fort Warth, Texas 76119 d

k c

j; i-

$i'

+

i e

5 k'

1 4-a' t-

~

4 k

}

i f

1 i

7 j-.-

}

[

a

-t t'

4 l

4 i

1.

Y d

'n l-

, ('./,L '....,

,-_,,,..,.m..

^

~~ *

--a-Tu tiectric JAN I 91933

  • bec to DMB (IE45)'

bcc distrib. by RIV:

J. L. Milhoan Resident inspector (2)

DRP Section Chief (DRP/B)

Lisa Shea, RM/ALF, MS: Mf4BB 4503 MIS System DRSS-flPS RSTS Operator Project Engineer (DRP/B)

RIV file DRS Section Chief (DRP/TSS) l l

i l

i

.L /

l

10 Electric JM i 91993 i

bcc to DMB (IE45) i bcc distrib, by RIV:

J. l. Milhoan Resident Inspector (2) s DRP Section Chief (DRP/B)

Lisa Shea, RM/ALF, MS: MNBB 4503 MIS System DRSS-FIPS RSTS Operator Project Engineer (DRP/B)

RIV File DRS Section Chief (DRP/TSS) i i

4 l

D:([p]P 1

RIV:C:DRP/I DD:DRP LAYandell;cd,)

TPGwynn ADBeach 1/llj/93

/

1/y/93 1/tg/93

MEETING

SUMMARY

Licensee:

TV Electric facility:

Comanche Peak Steam Electric Station (CPSES),- Unit 2 Construction Permit No.:

CPPR-127 Docket No.

50-446

Subject:

NRC MONTilLY PRESENTATION On January 7. 1993, at the CPSES Personnel Processing Center, representatives of TV Electric. presented to Region IV and Office of Nuclear Reactor Regulation personnel their monthly Unit 2 update of their status and scheduled activities.

This meeting was open to public observation.

TV Electric addressed the following subjects:

Overall Unit 2 project status Overview activities Licensing status SAFETEAM status Project Completion Sunnary Operational Readiness Assessment Team (ORAT) Readiness Indicators Attachments:

1.

Attendance List 2.

Licensee Presentation (NRC-Public Document Room only) ij l

1 k

i e-N ~ w

~~~~w-,,

w-mu,-wm.,.-~-we

-~.,,.s

,-ervg,.m,-r-,,

e,-

r

--h-'--

i ATTENDANCE LIST Attendance at the meeting between TV Electric and NRC on January 7, 1993, at the Unit 2 Monthly Presentation was as follows:

TV Electric J. Audas, Manager, SAFETEAM W. Cahill, Jr., Group Vice President, Nuclear Operations B. Bird, Manager, Work Control Center M. Blevins, Director of Nuclear Overview H. Dajani, Supervisor, Cost and Scheduling J. Donahue, Manager, Operations S. Ellis, Startup Organization i

D. Fiorelli, Public Information l

W. Guldemond, Manager, ISEG S. Harrison, Manager, Unit 2 Overview T. Hope, Unit 2 Licensing Manager J. Kelley, Jr., Vice President, Plant Manager D. Moore, Unit 2 Transition Manager S. Palmer, Stipulation Manager C. Rau, Unit 2 Project Manager A. Saunders, Assessment Manager F. Shants, Principal Communications Representative J.-Snydor, Startup Manager D. Stonestreet, Manager, Plans and Projects W. Taylor, Executive Vice President C. Terry, Vice President, Chief Engineer.

R. Walker, Manager of Regulatory-Affairs for Nuclear Engineering Organization D. Woodlan, Docket Licensing Manager J. Wren, Construction QA Manager Citizens Association for Sound Eneray (CASE)

0. Thero, Consultant Citirons for fair Utility Reaulationj CFUR)

B. Brink, Board Member C. Brink, Member NRC

[

J. M11hoan, Regional Administrator J. Partlow, Associate Director for Projects, Office of Nuclear Reactor

. Regulation (NRR)

J. Roe, Director, Division of Reactor Projects-lll, IV, V,-NRR-S. Black, Director,. Project Directorate IV-2, NRR-

'D. -Chamberlain, Deputy Director, Division of Reactor Safety (DRS)

G. Constable, Chief, Plant Support-Section, DRS D. Graves, Senior Resident-Inspector, Unit 2,-' Division of Reactor-Projects (DRP)

T. Gwynn. Deputy Director, DRP

,u ---... -.

,.=.

. =

4 B. Holian, Senior Project Manager, NRR J. Jaudon, Deputy Director. Division of Radiation Safety and Safeguards P. Koltay, Special Inspection Branch, NRR R. Latta, Resident inspector, Unit 2. DRP H. Virgilio, Assistant Director for Regions IV and V Reactors, NRR L. Yandell, Chief, Project Section B, DRP OTHER J. Douglas, Reporter, fort Worth Star-Telegram 9

J E

+

m

1 I

s ca aa, a. pa a a, a l

16ctt 2 Gommesetal Operation rn

.c: %

g

/

l c

6.. =.

1...,.,

}'

I ' ',[,,

y,f I

y 1,. ) -

t_

,p knWJP";L ; g g ye

.c s

<ma g..

l D__f&_ W : 951%y'*in<.=2G l

oh^"

a swt, w- _m I

- Js s

l E

I NRC MONTHLY PRESENTATION I

I J ANUARY 07,1993 I

I I

l l

= = = = - >

TUELECTRlC i

E 1

I I

1 1

5"E i

iLJ s

OVERALL l

STATUS I

1 I

I

_,.- - m u

r-u l

UNIT 2 PRO.IECT HIGHLIGHTS CONTROLLED MOMENTUM REACTOR, SAFEGUARDS, TURBINE BUILDINGS COMPLETE AND ACCEPTED BY OPERATIONS l

ALL SYSTEMS COMPLETE AND ACCEPTED BY OPERATIONS l

SYSTEM OPERABILITY PROGRESS CONTINUED SELF-ASSESSMENTS PAPER CLOSEOUT PROGRESS i

ENGINEERING TRANSITION l

DESTAFFING 1

CONTLNUED HIGH LEVEL OF QUALITY

(

I I

I I

I I

I I

ura!

I kJ I

OPERATIONS STATUS I

I il

PHILOSOPHY FOR STA-802, STA-815 AND SYSTEM OPERATIONAL l

POTE NTI AL LCOARS i

l l

EXTERNAL RFVIEW g

SYSTEM i

l

}

OPEN ITEW OPERATIONAL SORT /50RC i

f p

)WQgj O--

l R E CH C LIST 815 p

3 t

i PREP TEST INTERNAL TEST RESULTS e l

')

l l

PERFORM l

OC OO g _ _ _ _of l

f

) PT / AT REVIEW PKG REvtEW

\\

15 REVIEW,]

a, i

8 i

OPS

[

"eY2 f,

SusuiT STA-so2 C

SYSTEM UEL t OPERATIONAL READY TO LOtD LOAD

]

SYSTEu OUTAGES NON TRAIN LINEUPS QUIET TIME g__

e l

SYSTEu/ TRAIN OUTAGES SYSTEW/ TRAIN LINEUPS

[

C v

OPT 3/SURVEILLANCES I

IU LLEC1RIL CPSES UNIT 2 Punt.asoPw rce sta-sor, sta-ess AND sV17(M oPCPADLC f

wn nv

.ua nees i

-d!

=:

E~

E'i t4

,i

I 1

I I

O b

s s,

i 1

gg iI b

$E O

db

.18 5

$3 5

I m

E T

i5E 1

I E

I o

r;t

[3 [5 {l jf

E.O_

Z

]

a u

g 8 iiiii 9

l I

s

=

a a

l E

v ::. n x;

y :::;n:m n

E g/

Kg 1.N !g ?It! !=a !g !{.gOg l, 10 1, E :':t. f;;

E Ti L;

E

. ~.: i j*

K ut i !g

.g s..

r

.c 1:zY

=

5 3 g nq:

E r w;

L;:
L.o 2

u 8 na e

[ we.

m p.

y a I

.~

dk MT, h

'5 dI

= =:

a 2.:n n:

y tlf=fi!fEi !,{

Im h

I 4:. g

p: i 4.:

5 3 y:.m;m.._:

k=4.i s

q

- :e:

E

n.
n.. -.u.

B O_

7 m

r~=

'r 4 ; r:

E 7

,,/

  • r.. <;
EU tr[

~'

5 1' E lT ;

B

*r wN;: 1

$j'm

;0
i;
N I

..s, 6

.s ig{ti O

' g}i 3

~.

'{ ; jf! p

.j ga-Lg O tg.q

,:.',y' 85 i 'i

l I

q st jj d ajp:p p

m a

g/

1..a r

n; y

u q v

(.

.5
w u

8

=

a s=1:rg y

p._, n;

s A.

m m

W a :

~

>- m:m m:

waa

~

I; f*;

r[*[~.

e.,i

%.Am n.j

-1,-

s f
g F u

g I

n E! U. :n ;

ng : JL i

4, c g re, (f) r 11w

.~_m,.~.u..y n.,

=,...c.

hi U] 73

$E' E

~

= ],

A.:- e w

, n =

;= n i

a te

v v 9
,,gU

, ??

- / ILUi j T !;

tj- %M(:..yri_ h

.JP, 1:

i y-

,-0 M

t g

ni s'

j.. 7a i eg g

L

-[Q;;! :

e a

n..

p

Hj jp E! Hc E

7, "I c

y Al fic ab m

u u

'i$

r 4

= 0 g g a-~

o g I

_ _ _. _ _ _ _ _ ~. _ _ _ _ _ _ _ _ _.. _. - - _ _ _ _ - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

mm una ses' W um W uf '

COMANCHE PEAK STEAM ELECTRIC STATION UNIT 2 SURVEILLANCE TAKE CREDIT PACKAGE SCHEDULE 500 R[$P

[ AST WEE K THIS WEEx TO DATE SCH ACT SCH ACT SCH ACT EpN 22 19 16 34 57 53 N

N Puu 9

0 10 17 SO 41 ewe sc we N

PEW 33 79 0

0 202 1ES s

TOTA 64 98 26 51 339 262

]_ _

x*

.w.,o.m.

N

---o---

9 rwm acmu.

g 300 -

x i

3o x

nu seestar (n

s

~

N s

- r-If G

202 g

o_200 -

N i

N.

N N

N N 162 N, - \\

s sN 162 k' @*: -

'3' *.

\\

' A_,

~!-

N 6 PACKAGES RETURNED s

\\

N

  • '09 100 -

-e x

00 N

D

  • ... '=.

I N

.,_,,,~~*

-1 34 s

,,,_-e..-

e jg

    • g

~

"~ ' " ^ - ' ' ' ' ^ " '

0 i

i i

i i

i 1

i 14 29 28 93 12 19 26 02 09 96 23 30 es 13 WN DEC JAN Fts 1992 1993 Pt.ANNER LypAAy N'XR n"NM SURvCRED Dpw A

M M

M M

M M

M M

M M

M M

M M

M M

M M

M i

COMANCHE PEAK STEAM ELECTRIC STATION UNIT 2 - HARDWARE

SUMMARY

t 4,000 AS OF 01/05 PRE 802/810 l

24I i

I 3,500 -

POST 802210 l 1,053 l TOTAL Ml 1.077 l i

i 3,000 -

SCHEDULED

[

ACTUAL 2,500 -

[

I N

2,000 -

t I

o O

1,500 -

f l

~

TARGET = 1,000 1,000 -

i 0

l

)

NOV DEC JAN 1992 1993 i

REVISED 12/09S2 Un

E E

E E

E E

E E

E E

E N

E E

N E

E E

L COMANCHE PEAK STEAM ELECTRIC STATION UNIT 2 - TOTAL PROJECT SOFTWARE

SUMMARY

(CDR,NCR,TUE SWA,CWO,DCA DCN,UIR, PET,CDF,SWP,SDR,TM,CWD,ER,MIT,0NE,TE) 15,000 AS OF 0105 TOTAL

-l 2A4]

SCHEDULED

--===

AcmAL 12,000 -

9,000 -

N P

5 6,000 -

3,000 -

N,,

TARGET = 2000

's 0

NOV DEC JAN 1992 1993 ch

l!

l

lI 1

sus a

us a

l II 2

9 A i

0 J 7

119

+

0 2

t u~

o

/ /

/

g n

3 o 2

u 1

\\

j(

1 t

1 n

m*-

o 5

\\

i

,9 e

20 C c s L

t t

P e w

II M

s

\\_

i 2

s NTI i 9 I

D s

E o

C M

R E

N N

o_

K D

O 7

R R m

E A

t N

c 3

5 i

2 N

A 4

s i

1 A

s T

' O m

'^ O L

C P

S o

' T n

e w

o 3

3 e

r c

C a

s i 5 0 I

tn R

T o

E u

ws r

R T

N A

U y

c F

m o

D r

a E

u c.

C E

N o-i 8

[,

a e

2 r

E C s

s E

M t

" O t

R T'

P

~

o s T

P L

w r

o t

o T

V E

O O

1 N

LE s

i 2 M2 V AT E ENI D i

to TU E S

RU i

7 0

D K

E A

C i

i 3

1 E

O 1

N P

R P

\\

E

\\

o 4

H

\\

i 2

C T

N C

A N

i 71 O

M

\\

O N

C

[

i 0 1

/

/

g

\\

i 3 0

\\

\\

\\

P g

i 6

E 2

S 0

0 0

0 0

0 0

0 0

0 8

6 2

0 8

6 4

2 e

2 1

1 1

1 v

u conp Q

l f

1 lljl lI l

ll i

l (l

I I

I I

I

!I u

i.I

[s 4lI urum lg b

5

!3 MLECTRIC 4

!I OVERVIEW

{'

ACTIVITIES lI ilI

,lI

<'I i;I I'

-r.

.c.

, ~..

ISEG READINESS ASSESSMENT SCHEDULE 1992 1993 NOV DEC JAN FEB l

l DPEN l

j l

READINESS ITEM READINESS l

OBSERVATI@,

VORKOFF

_0BSER ATION i

77 1/ 11 12/14$

(12/17 1/4, g

i

~]

I I

I i

i g

I I

I g

I I

I g

l I

I I

I I

g i

i I

I I

g I

i I

g I

I I

g ISEG ASSESSMENT 12/21 1/4' 1/11 14 INITIAL TU TU TU DRAT FOLLOVUP ORAT REPORT COMPLETE REPORT COMPLETE ISSUED ISSUED 3

2

.5

.r

sus a

ma gas aus e _ uge sum sem e

um m

e um mm em mall RESULTS FUNCTIONAL AREAS ITEMS IDENTIFIED PLANT OPERATIONS 26 MAINTENANCE 18 SURVEILLANCE 12 ENGINEERING /TECIINICAL SUPPORT 29 SAFETY ASSESSMENT / QUALITY VERIFICATION 5

RADIATION PROTECTION 3

SECURITY 4

EMERGENCY PREPAREDNESS 6

PROJECT / PLANT MANAGEMENT 0

LICENSING 2

TOTAL 105 i

m me h gus um em m

num um um en um um e

uns em um e

um RESULTS

SUMMARY

NO IMPACTIVE OR SIGNIFICANT ITEMS HAVE BEEN IDENTIFIED.

PROCEDURE RELATED 28 EEQ 15 CONTROL ROOM DESIGN REVIEW 9

TRAINING RELATED 8

STAFFING RELATED 5

NOTES 31 ARE TRACKING ITEMS OF WHICH THE PROJECT WAS AWARE-e.

73 HAVE BEEN CLOSED 13 ADDITIONAL ITEMS HAVE ACCEPTABLE ECDs 5

am e

e au. sus a

un saa num num enn aus sus muu uns em um eum m

CONCLUSIONS PROGRAMS ARE BEING SATISFACTORILY IMPLEMENTED.

POSITIVE PROGRESS IS BEING MADE TOWARD OPERATIONAL READINESS.

OPERATIONS NEEDS TO INCREASE ITS SENSE OF OWNERSIIIP OF UNIT 2.

OPERATIONS STAFF (AOs) NEEDS TO BE DEDICATED TO UNIT 2.

i l

l i

U

E J

I I

I I

WM i

iLJ 1

LICENSING I

STATUS I

I I

I

, uma sus num aus amm uma num num sum uma um num nun amm smus sus ami mum sua -

LICENSING ISSUES FOR NRR CLOSURE (AS OF 01/04/93) e NRC BULLETIN 88-05 ON PIPING MATERIALS OI (18) SEISMIC DAMPING C

.m M

M M

M m

e M

M M

M M

M M

M M

m m

M-i LICENSING ISSUES FOR NRR CLOSURE (AS OF 01/04/93)

ISSUES ISSUES WITII ISSUES WITII NRR NEEDING OUTSTANDING NRR FOR REVIEW SOURCE TU ACTION OUESTIONS CLOSURE COMPLETE TOTAL OUTSTANDING ITEMS (SSER 25) 0 2

8 21 31 CONFIRMATORY ITEMS (SSER 25) 0 0

2 5

7 LICENSE CONDITIONS 0

0 0

1 1

GENERIC CORRESPONDENCE O

1 0

3 4

OTIIER 0

0 0

5 5

TOTAL 0

3 10 35 48

\\

m m

M M

M M

M M

M M

M M

M M

M M

M M

M' COMANCHE PEAK STEAM ELECTRIC STATION - UNIT 2 LICENSING ISSUES FOR NRR CLOSURE REQUIRING TU ACTION Cl DATE: 01/04/93 (5)

PSI Cl OUTSTANDING ITEMS (Of) 19 (R48)

(1)

CONFIRMATORY (Cl) 4 01-Ol OTHER (GENERIC CORR.

(19)

(3)

OR TU ISSUES) 6 Oi 01 TOTAL 29 (10)

(16)

Of Ol-(8)

(17)

O!

01 01 SPDS 01 (13)

(27)

(7)

(C34) -

(24)

PAVAA Oi 01 OI Ol NRCB O1 (U10)

(31)

(22)

(2)

- (26) 88-05 (11)

Oi

- Cl Oi Of NRCB Cl GL88-14 01

- (6)

(6)

(29)

(1) 88-04 (7) l l

l (12) l 10/03 10/10 10/17 10/24 10/31 11/07 11/14 11/21 11/28 12/05 12/12 12/19 12/26 01/02 LEGEND PAVAA.

- (U10)

ACTION COMPLETE (29)

Ol*

(24)

RESCHEDULED TO DATE SHOWN (C)

E

. COMANCHE PEAK STEAM ELECTRIC STATION - UNIT 2 LICENSING ISSUES FOR NRR CLOSURE - NRR REVIEW SCHEDULE DATE: 01/04/93

-Oi-Cl OUTSTANDING ITEMS (01) 31 (16)

(6)

CONFIRMATORY (Cl) 7 01 Cl OTHER-8 (31)

(5)

TOTAL 46 Ol*

Cl*

(2)

(1)

LEGEND Oi ol

._ (5)

(28)

O1 Ol*

Ol*

(15)

REVIEW COMPLETE (33)

(13)

(18)

NRCB*

Of Ol*

REQUIRE 88-05 (17)

(16)

RESCHEDULING (11)

Cl O!

(7)

(23)

Cl Oi-Ol*

(2)

(8)

(9)

PAVAA Ol*

U-10 (7) 01 Ol*

(3)

(1)

O!-

01..

01-Of PSI (30).

(25)

(10)

(6)

(R4B)

NRCB' 01

.Ol OI-01.

Of SSRP Ol*

Oi 88-01 (29)

(21)

(14).

(19)

(26)-

(24)

(11)

. Of Cl O!

Ol

- 01 Of NRCB GL Oi-SPDS CI (15)

(3)

(20)

(4)

(27)

(22) 88-04 88-14 (12)

C34 (4) 10/03 10/10 10/17 10/24 10/31 11/07 11/14 11/21 11/28 12/05 12/12 12/19 12/26 01/02 01/09 01/16 AT OR POST OL LC

- AIR LOCK LEAK TEST SSRP-STEADY STATE REACTOR PHYSICS METHODOLOGY TOPICAL REPORT Un

mas amm ums num-muu amm mum use ums num um amm mai aus sus mum uun mum..ums l

l COMANCHE PEAK STEAM ELECTRIC STATION UNIT 2 TOTAL CDF WORKOFF 2,000 PROGRESS NOV DEC JAN I'

SCHEDULED 332 85 29 ACTUAL 206 271 1,600 -

1,400 -

1,200 -

__.'== _ __.,

1,000 -

's s s 800 -

-s s

s 600 -

~ __..s 400 -

's AS OF 01/02

=*s 200 -.

ACTUAL

--e-- l 390I

's,, 's CURRENT senEDuts

---i es i l

JUL l

AUG I

SEP I

OCT I

NOV I

DEC I

JAN 1992 w-

m M

M M

M M

M M

M M

M M

M M

m m

m m

COMANCHE PEAK STEAM ELECTRIC STATION UNIT 2 - REGULATORY ITEMS i

WITH CORRECTIVE ACTION REQUIRED 100 AS OF 01/06 pooJEcTED

              • 1 to 1 1

.90 -

l ACTUAL

===4==- l 22 l l

80 -

TOTAL OFEN ISSUES 1

DI ISSUES WITH NRC I

I FOR CLOSURE l

60 -

50 -

40 -

\\,

30 -

\\,

20 -

g' 10 -

i 0

g DEC JAN 1992 1993 U

m e

e e

m-m m

M M

M m

M m~m COMANCHE PEAK STEAM ELECTRIC STATION SAFETEAM CONCERNS BACKLOG 200 175'----------------~~~~~---~~~--~~----------------------------

150

- - - - - ~ ~ - - - - - - - - - - - - - - - - - - - -

- - - - - - - - - - - - - - - - - - - - - - - - - ~ ~ - - - - - - - - - - - - - -

125 o

O

.J M jQQ o

4 In 75 50

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - ~


- -- ------- - ---- - ~ - - - --- - ----

25

~ ~ - ~ ~ -- - ~ ~ ~ ~ ~ ~ --- --- --- ~ ~ ~ - - ---- - -- - -- ------

- ~ - - -

0 01 16 01 16 01 16 01 16 01 16 01 16 01 16 01 16 01 16 01 APR MAY JUN JUL AUG SEP OCT NOV DEC JAN 1992

- >=a 00

_ -. -. ~ _. - =

LI lI SAFETEAM ACTIVITY l

l RECEIVED l

45

~~"""""""

43 INVESTIGATED t

40 ANSWERED l

37 l,

35

~~ "' /

~ ~ ~

32 I

^

30

~ " " - -

28 28 i

s

'I 26

?:

26 25

-~

/

20

-~-l#

I

,e 15

~~

~ " "

L 13 i

=

[.

I jQ

{

i 5

'I o_t

_L...,

SEPTEMBER OCTOBER NOVEMBER DECEMBER 1992 wa~

.l 19

c

~

l i

I l

e l

PROJECT l

COMPLETION I

l

SUMMARY

1 I

I

W Q~y~,~y"s~m mat. m m

m

~

^~~

~

ORAT READINESS LEADING INDICATORS SYSTEM OPERATIONAL SOFTWARE COMPLETION HARDWARE COMPLETION AT/PT RESULTS APPROVAL (JTG)

PROJECT STAFFING l

k$

l

M

&~ ~$

M M

M COMANCHE PEAK STEAM ELECTRIC STATION TOTAL PROJECT STAFFING CONTROL FORECAST ACTUAL 5,500

~

5,000 -

's 4,500 -

s 4,000 -

s 3 3,500 -

s a.O y 3,000 -

s, u.

o 2,500 -

m s 2,000 -

D Z

1,500 -

's,

~~~

1,000 -

WEEK ENDING 12/26 s

HEADCOUNT 2,162

_, f 500 -

DECEMBER g

2,6 0

,,,,,,,j,,,,,,g,g,,g,g,yg,g,,,gy,g,,,g,,,g,,,

,g,,,,,,,,,i,g,g o g y,g,,,g o g,,,, 3, j,, g, g,,,,

1990 1991 1992 1993

~~

r

COMANCHE PEAK STEAM ELECTRIC STATION UNIT 2 AT/PT RESULTS APPROVAL 175 AS OF 01/06

- ronECAST 2 - - -l 154 l 1

CURRENT.

'~

150 -

.....l 148 l O

SCHEDULE p

, ACTUAL

"-#--" l 141 l p

-~_;

[

PROJECTED

""""l 155 l

,s j

125 -

/

/

/

o

/

o' 100 -

/

m p

w

/

l o'

M

/

1 y

75 -

l M

a N

/

l c

50 -

l a

,e*

4 25 -

a MCLUDES 7 DATA PACKAGES ON

~

DELETED TESTS.

4 l

0 g

g g

g i

JUL AUG SEP OCT NOV DEC JAN 1992 1993 to tu

ya F y 1

l COMANCHE PEAK STEAM ELECTRIC STATION UNIT 2 - HARDWARE

SUMMARY

4,000 AS OF 0105 PRE 802/810 l

24 1 3,500 -

POST 8021810 l 1,053 l TOTAL EME I 1,0n j SCHEDULED 3,000 -

ACTUAL 2,500 -

2,000 -

k l

3 1,500 -

T ARGET = 1,000 1,000 -

500 -

  • e 0

l NOV DEC JAN 1992 1993 REVISED 12/0992 r

- umma

-- s u

u u COMANCHE PEAK STEAM ELECTRIC STATION UNIT 2 - TOTAL PROJECT SOFTWARE

SUMMARY

(CDR,NCR,TUE,SWA,CWO,DCA,DCN,UIR, PET,CDF,SWP.SDR,TM,CWD,ER,MIT,0NE TE) 15,000 AS OF- 0105 TOTAL

-l 2,304 l l

SCHEDULED

^ * *'

12,000 -

9,000 -

N Fz sa 6,000 -

    • s.

l 3,000 -

TARGET = 2000 l

~

's 0

fjOV DEC JAN 1992 1993

___._.-___.,._________.-_,,.m.__--_

b i

=

e e

, hit

$P. -

n 5

5 m

~

n at I

[g g

o O

Mi 3

e Z

i N

4 5

8I EW w

n, A

ad s-h GP i h

w m

e t

0 J

o

~

I n

r, i

.'2

'E dl

- (

g m.

n 3

I d ; :p d ga

s a.g g j n.

j i

I g

1

,i n 7

g b,'a 1

4

~_

e O

g 4LI

-l l

g l l "1 g

  • g l

3 5 ill l

! ]l :s fij.1 N2iE !!iEE i

i!

!! qi rj 11 d g l

1iBg; ![

z nyc n u $m i i nm n==

v w

n 1

I a

7 egg; o

x l rl*ur...== = =_aEE_lFEB8WESI e.

ia

  • ="
  • 4

.m O

l T

o

$MW r

l u

7

g g
g ;y 57.= r
x e

6 2

NWMm'k_. be

-~

5--

. L W S a n a

vnmi

_na :

. t In.. -

p gl t : tam.,

2.-

I

..c..

M

} V :r : : ::

l _4 v.j %

i, 4

(/)

==w~

s=jlDiiS jig f.

y

. n :v: u e

.=, r.

mmw -

w w. s. hy. g==.... n... q=mg[

n w

[N5h.tf5I((;dj w

[W1['.g/d 3: -

M 3

4;; C3 f

ff h tg

}-

/ :gy.;ca=.._.f 3 :/ I lr53f l W.. _....

u

_.t: i,; :

h jig

,s, kj.-N4 ; ~.;:); L i:.;;Jty :J;; 1 ;i q$\\ f.111 c1A t ^.:':::::q gr 1, - r:

t i ; '. *t,,-T -J j l [ * '.! ; -

\\dh, Uj '.2 FIT N k.h1LIIL,i.I a T*"

i tE ze r r::7 e m-b

.i:Jc : :.

M {l

[; 7 M

g;.gl

? 8 Es.;W.

s ?

ar w.

I I

- 007 5

o,'Or c

Eo E

- 6e ft tg g

rc '#'

5 s

- o e

e f0 V.9

'o a

o

- v i

r!0 4

'o

'e o

- os w

o'Cr d

4kk'o, sM

'u c

>,0 g' o

o o, a, g

Z f

t v,

  • o,##

1 Om e

rg I-E

'k A

E s

<[

n, 1

as I

as,'

6 g

- ' %,0 1

f-N1 o

'#o,7 g

(f) k!.

wa k

ew Q

,\\,

h D, h *,

- #2 0-ma o * - <%g s

0/

O' 43

'u.

o. - 1%

e.

o i-e.,,,0 ol t._.

N 1

k w

1 1

- #'s c,', @9 O

"x s

W 5 V) i

- l*s ro s ei a-n B

_.J J L.

s s

,% gg s

s g%

1 v

s c,

hp'7I ?

s C

N 4

a

- O y.2 O

ny Ft 9-i m.

- e s

I-4 l <

s t wc.

x.

4

=

- e %,o wn*

LAJ eq o_a s

s

  • s u

'"r y,f 'i g s

s t

a b

I s

I i

i Ny 8

n

- /orm H

y i

s

  • s a,

/"r.p U") !

tr 3t e

s Z LJ o'

7.

s1

'"r,7 w

'a.,0 d.

n u

a

'5, r

MD 3~

  • s r

7 F-5 R

8

r a l I

on

=

a e'Or

'i'

<{

{-

N*

i o

o,,e,El u

N t

o s

p 4

V' q I

4e*'9knp' 0 E;

1 k

e$l;,

d

'1

'y s

m E

e- ::

I or k' -

g U

R

\\<

<o

+

x a-n

s.,

s.-

n'rt g

s LAJ d

e0$ Do

-o N '* *

/p s

t n.

v s-

~

s m

o t' ts }i t".{, g

\\

- do ft I

p i' n

hh EI

- [-

hl U

~

z m Y.. oMe

  • M j' ~
[4 g, 5

g ce e

)4 4

.e2 fu t9 g w

to*

o E

Znl

'A a*

r I }:.h t g "o y

g n

3 I

2 B

N 3

g U

d I H * $,#sd U

\\

'A'/

S

,w

~

O E

~

s

\\

'A Ejvied D i s h t; 4

E

'%' t g

c 2

e l.

y C

l d n ses 3 8 2

s%

kyj te re R

25,g sg<*d E

n i

u

=

y I

I l

6I i

u o

o o

o o

bI o

o o

a w

o.

o.

o.

o.

I o

o o

8 I

M M

N g

1333 38V005 5

- mus um amm um t

r t_;

UNIT 2 PROJECT CHALLENGES CONTROLLED MOMENTUM SAFETY THERMOLAG COMPLETION SYSTEM OPERABILITY SURVEILLANCE PROGRAM e

TRANSITION TO DUAL UNIT OPERATIONS OPERATIONS READINESS COMMITMENT CLOSEOUT t!

I I

l innes I

t -"

EttcT5 ADDENDUM i

l I

I

I l

AllllREVIATIONS ABR AS BUILT RECONCILIATION ACCESS AUTOMATED CONFIGURATION CONTROL AND EQUIPMENT SUPPORT SYSTEM ADC ADVANCE DESIGN CHANGE I

AOV AIR OPERATED VALVE AT/PT ACCEPTANCE TEST /PREOPERATIONAL TEST BOP BALANCE OF PROJECT I

BRH BROWN AND ROOT HANGER DRAWING BRHL BROWN AND ROOT HANGER LOCATION DRAWING BRP I

BROWN AND ROOT PIPING DRAWING (ISOMETRIC)

BVR BASEPLATE VERIFICATION REPORT CAP /SSER CORRECTIVE ACTION PROGRAM / SUPPLEMENTAL SAFETY I

EVALUATION REPORT CCP CENTRIFUGAL CHARGING PUMP CDR CONSTRUCTION DEFICIENCY REPORT I

CDF COMMITMENT DATA FORM CI CONFIRMATORY ITEM CMI CONFIGURATION MANAGEMENT INSPECTION I

CRR CONDITIONAL RELEASE REQUEST

~

CTH CABLE TRAY HANGER CWD CONSTRUCTION WORK DOCUMENT I'

CWO CONSTRUCTION WORK ORDER DBD DESIGN BASIS DOCUMENT DCA DESIGN CHANGE AUTHORIZATION I

DCC DOCUMENT CONTROL CENTER DCN DESIGN CHANGE NOTICE DCRDR DETAILED CONTROL ROOM DESIGN REVIEW l

DGB DIESEL GENERATOR BUILDING DM DESIGN CHANGE AUTHORIZATION DMRG DESIGN MODIFICATION REVIEW GROUP l

DR DEFICIENCY REPORT DRQR DESIGN REVIEW AND QUALITY REVALIDATION (RE/ DIESELS)

EA ENGINEERING ASSURANCE EAP ENGINEERING ASSESSMENT PROCEDURE ER ENGINEERING / ENVIRONMENTAL / EVALUATION REPORT ERF EMERGENCY RESPONSE FACILITY ECD ELECTRICAL CONNECTION DIAGRAM ECCS EMERGENCY CORE COOLING SYSTEM ERP EMERGENCY RESPONSE FACILITIES I

ESFAS ENGINEERED SAFETY FEATURE ACTUATION SYSTEM FC FORECAST COMPLETE FCN FIELD CHANGE NOTICE I

FCST FORECAST FL FUEL LOAD I

I 28

I I

FP FIRE PROTECTION FSSA FIRE SAFE SIIUT DOWN ANALYSIS IIELB lilGli ENERGY LINE BREAK l

lift llOT FUNCTIONAL TEST IIVAC liEATING, VENTILATION, AIR CONDITIONING I&C INSTRUMENTATION AND CONTROLS l

ICD INSTRUMENT CONNECTION DIAGRAM IDM INTERFACE DESIGN MODIFICATION IGM INTERNALLY GENERATED MISSILE IOER INDUSTRY OPERATING EXPERIENCE REPORTS IR INSPECTION REPORT ISEG INDEPENDENT SAFETY ENGINEERING GROUP I

IDM INTERFACE DESIGN MOD ISU INITIAL STARTUP ITS INTEGRATED TEST SEQUENCE I

JPM JOB PERFORMANCE MEASURE JTG JOINT TEST GROUP LDB LEAK BEFORE BREAK l

LLRT LOCAL LEAK RATE TEST M&TE MEASURING & TEST EQUIPMENT MCD MASTER CONTROL DRAWING I

MEL MECilANICAL EQUIPMENT LIST MELB MODERATE ENERGY LINE BREAK

,I MIT MANAGEMENT INFORMATION TRACKING MOV MOTOR OPERATED VALVE MOVAT MOTOR OPERATED VALVE ACTUATOR TESTING I

MSTL MASTER SURVEILLANCE TEST LIST NCR NON CONFORMANCE REPORT NRC NUCLEAR REGULATORY COMMISSION I

NRCB NRC BULLETIN NRR NUCLEAR REACTOR REGULATION N-5 ASME CODE SECTION III RELATED TO STAMPING OF PIPE I

NSSS NUCLEAR STEAM SUPPLY SYSTEM NOTO NUCLEAR OPERATIONS TRANSITION ORGANIZATION OFA OPTIMlZED FUEL ASSEMBLY 01 OUTSTANDING ITEM ONE OPERATIONS NOTIFICATION & EVALUATION FORM ORAT OPERATIONS READINESS ASSESSMENT TEAM l

P/T PREOPERATIONAL TEST PAVAA POST ACCIDENT VITAL AREA ACCESS PET PLANT EQUIPMENT TRANSFER PDCR PROPOSED DESIGN CHANGE REVIEW PM PREVENTATIVE MAINTENANCE PRDP PROBLEM REVIEW DOCUMENTATION PACKAGE I.

PSAS PIPE STRESS AND SUPPORT PSI PRE SERVICE INSPECTION I

l 29

I I

QAP QUALITY ACCOUNTABILITY PROGRAM QC QUALITY CUNTROL RCA RADIOLOGICAL CONTROLLED AREA I

REA REQUEST FOR ENGINEERING ASSISTANCE RF02 REFUELING OUTAGE #2 ALSO 1RF02 RIV REGION IV l

RWO RESPONSIBLE WORK ORGANIZATION (MSTL)

RX REACTOR VESSEL SAP STARTUP ADhi!NISTRATIVE PROCEDURE h

SALP SYSTEMATIC ASSESSMENT OF LICENSEE PERFORMANCE SDR STARTUP DEFICIENCY REPORT SID SYSTEM INFORMATION DOCUMENT SIT STRUCTURAL INTEGRITY TEST SORC STATION OPERATIONS REVIEW COMMITTEE SOER SIGNIFICANT OPERATING EXPERIENCE REPORTS I

SORC STATION OPERATIONS REVIEW COMMrITEE SPDS SAFETY PARAMETER DISPLAY SYSTEM STE SYSTEM TEST ENGINEER i

SWA STARTUP WORK AUTilORIZATION SWO STOP WORK ORDER g

SWP STARTUP WORK PROCEDURE 3

TE THERMAL EVALUATION TG&V THERMAL GROWTH & VIBRATION TM TEMPORARY MODIFICATION I

T/O TURNOVER TS TECllNICAL SPECIFICATION I

TU EVALUATION (CONSTRUCTION & STARTUP) FORM TUE U/D UNIT DIFFERENCES UIR UNSATISFACTORY INSPECTION REPORT 802 SYSTEM TURNOVER TO OPERATIONS 810 ROOM / BUILDING TURNOVER TO OPERATIONS I

I I

I l

'I l

30

i1il 1lj llliIl!

ijl' lI l

A

,1

'.i <

f y4%

m n ' M-C l

8 N

e J

r. 8 -

9 8_ 2-c

~

l m.

t1 c

A A. A m E y L.8 T :m f" r

.s J

w y

t(

I er m

t s

ts g = c.

. +c n=

c y.

=

s t

'Cc s

e t

a i p,.

su uP "s sm s

m .

u.

C r.

T tr i

a.i e*=

u m

m *, E,, c

  • v A

s

=

t c

,r r

e m.,

- t t

v s

1 t

's c,

Fes 1

.p

=

a vs j

Ut

=,e imx t

t et e

co s

r ro p

7 F

sp wtY Urt C

3l a

a t

.'y-9 J rs g\\

?

eer h r 1.

fw s

e s

t v,.e ri te

~

r v,::

.9d3 lIlII;l II i, g tg ;g IiiiiiIg ti3 g

g {

IjI e

lae i=

s tt E

Wrm e,..!

E ; ;

,U f,!.j e

F me C a :=

I rs trC s

r W w==

aa a

e

\\

'f.;.!jjiMs, s

v ym p

~

m n

tFa*

r

~

%i g

f ra s

t. e li w

r s

,a 6

e

a 7if a

t,

=Y e S.e.m. s.

,A g/-

O

~

'w tm t

v t

,3 epi c

i

m. c'_

s ew s

rc u

+

mr r

tT s

c t us sC as

=. r cu otn I

rY r

s a

o e

s w

esa a=

s rq m

tm s

e I

m 1 m m c.

c. 3 r=

w e!

I.

ije *!

rr a

1 e

eI A

a.a

.a s

u st tu are n

E m

d = ;,' ;.t sm mP gm ea s<m T u U

r a

e

~

l n

u t

cr s

J s

s U'.

a ct ra. Scr

\\

m9 s

a E

wm eri T

ur l

rr t

r

_\\

rr o

t s

st r

r at

,;.Pst

,,e

t

'r J

a t

r 3{,.**

s e

sr s

ws W

I T

rM a

n r

i t

e

?

i m

s e

t sr st E

E We y

e t

T_

M Te n

r s

e mom N3-a a

s u

s n

u e

e a

p A

=GN s

t s

>sW m

t r

a wa tcm v

i y

FV#

fa 's a

s a

1 e

u+F

=

rC3 s!

r r

w r

e a

1 o

r s

g';_

z t

s n

l j

F s

e a

e r

c MI s

c

=

C a

a B

s s

n r:

I c.

a e

,l tl:+p J

.e.

o 7

,.T

.. w i?

,e4 r

1l

D
  1. e!.

lt;

..:,l...!

$s s

!e n

T t

m is r

o T

r e

a m

=s t

a E

r t

1 7p

=s s

8 i

a T

c e.

t f

s c

u s

w t

m

==

T W

o u

w r

e r

a r

o

  • e s

r m

s a

v t

r t

i s

a a

t m

e C

m n

C r

a s

r c

u u

v r

a s

e a

c e

n m

st r.

i t

i st r

s a

e w

i r

s r

=

c c,

a e

a i

v a

n y

m i

n t

t a

a t

v a

a s

a t

p r

c l

n t

s r

t v

m i

s.

r e

J r

m s

e a

s w

a t

n r

l 1

a a

v.

y J

w a

r m

s s

w I

1 6

o t

s t

=

u r

r w

r n

v a

a e

r r

a a

u e

9 i

T s

G r

t e

=

a

'a i

ia u

s e

s c

s' a

t s

I D

s D

t r

r t

r_

s t

G c

-e n

n D

i, e

s a

t a

v m

'w t

v r

m t

e s

T r

r i

t w

n I

4 t

t a

f s

t T

w a

t n

F t

r m

a s

7 s

e t

t

?

I t

p r

C 1l s

a t

D 7

J w

t.

r rf t

t e

7 1i t

a a

s C

wt c

r r

J r

n e

P

_ ' e E

a T

T mt C

I t

I om D

r C

ac i

se 2.

I

_ ~

D l

1 I

a T r,, -

l C

t J

J,,.

c..

l e n,.,

r, J

2I ys.

W 9

1 gae i

'I jl l

Ify' N In TN7T

'TN'"UJ7dhi Ty*pn

--u 77 pg

[g

'L t g 7g g

SC AL1% CAL CS

  • s' l

I Y

CONDLOf CALtl V/fetfea(A E t'

?

'E,%,

C 0&P (Le<!f I L8't Af t)

'C '

  • 1' ar e Cat [ vat it(Rea3L AG UPt,aagt te

~

g l

0 f.8 DJILT kICl>CILlefitww 9 (Att)

=

f PL ANT CthqPQT(R PHA$t ll T*

I l

LQ DWt/1N KRC PPG $UP4T5fl$

({A)

HYDR 3 TC$fl% (PP L INSTR IK.)

(tA)

~

l I

FVAC $UPP(Fl$

((A) l I

INifR M NfAf!DN (L OUP)

HVAC INtuleflLN

($f') ges l

CARLC teAf 6 tUPPtst$

T AG$ f*'

"I*

CONDJIT/$J'PORf 5 TAG $

I 5

g l

VIBC & CA9tt TAG $

.y itDelhafims TAG $

1 I

k PAINT & CIMf tN0l(IRCLUDtl PNI $HP) ($f)[#W Wy er

[

l 8

h H

Pt htf aAfith ILALs

({ A) 2 *

  • W 0,

THtDMCA AG

($r'*" ~ evre any. P18T 4 (DJIMENT ]N3tL AtlDN Qf) w;w l IIUCUMINT v4LilNG pf 1 AG ' pr. r p. 0 l g con. Aceti cmi.a .p y l i .P,<,.<,,,,,.. l 5 I td 1 H l C(PW'L C T[ 517 / 11 5 MILESTONES l' I i. 1 l x PRE-OP Phuct tiLRC DCviLtN'*t hf ( AM*L ) ? Suttr$ttu TLstNDvtR1 ~ Y [ I I "I" I"

  • h' l

l CuaP(M N1 7[$IING $Y11(N Tue*CvtR$ 'l 1 l l Y 'i' ' i' PRI-uP YtitlNG (51 arf 3) 90F TURhDVIR5 h k Y l I rLutHING l TUR$1NC RO10a kCvisex l g if 5 CDMPLCit TG 6 Y l ,t.f. TH(kMAL GRDv1H & VIS8 AfitFt 3 M.Y Y. T '...... - M I itCHNitAL SPCClricattuNs atvity .Q L W ". R. N 5'11tm L ARELING IN$1 ALLAll!N '%DCEDLNC ttv(LIDHCh7 l 5 i I SPECIALfY IftN5 l N0fDR DP[RAf t D VALvt3 ' i' P 1 I l l [ T D y l KR CLDSURC l 9 CDotDINAft Closuut ur Rtcutafow? IftMt ? 13 A 3 g 1Atr tanRDthafith ron uN!f f P g~ h LittNit% canNtintNis (ccrs) S" '? U M g i PET Rtvitv 6 atPLActmEnt twint.tnim TU ELECTRIC a exin tattran CPSE$ UNIT 2

  1. [E mat a so I

s

  • = = = =
  • CRITIC AL PaTw at E

f 1 r see cmf m,. -~ m,a ^ - - - E t 32

um, r ISU PROGRAM SCHEDULE 11/05/92 Comanche Peak Unit 11 Lm 100 % \\ 100-g- Y EW 75-3o s E / sa to e 50% 50-o ( W / nnwe w [ lentono Y so ,/ O* 25- / f l W 5 < >l D ~ e O 1-dg muk 2 mt toe 2 / 1,, -- I L / ~ ,l 7M"- russenouram s-

    • I e

i ISS 240B N2608 --mw ISU-101B = ISU401B ISU4108 = = = SEQUENCE PROCEDURE l ta l l

T 1 UNIT 2 POWER ASCENSION hkD MODE 3 .25 DAYS I INITIAL l CRIT 14 DAYS. MODE 1 0 DAYN I f TESTING THRU 507. 7 31 DAYS 150% ! PLATEAU fREVIEW9 10 DAYS: t f75% TESf. LNG 12 DAYS 100% ISU i THRU COMPLETE COMPLETE f ISU TESTING 24 DAYS l TU ELECTRIC j CPSES UNIT 2 i UNIT 2 POVER ASCENSION ( 3eAvN DATE REV FSE 01/05 0 Q l ~ ~ 5 = y

Eus afas ins sus aus sum use ame uns sus uns as sua sus sum uns aus ses sus COMANCHE PEAK STEAM ELECTRIC STATION UNIT 2 ENGINEERING TOTAL OPEN DOCUMENTS ommers oats new MOTES OPEN OPEM DoctNENTS TOTAL OPEN WORKOTF 'M D?11 9

1. THts GRAM 4 REPnESENTS A. etTM WPvDow ECOPE LAST WEEK -

DCA TUE TE TNf3 WYEK ACTUAL MJV 07311 1

2. Tot AL oPEN MUCtUDES OPE 4 3

3 1 0 4 1 B 183 81 29 50 160 -23 6M --

s. vs.newovfo enons ToYmL og er23*2.

C 38 17 2 3 22 16 D 4 0 4 0 4 0 E 19 14 3 0 17 -2 TOTAL'l 247 115 39

  • S3 207

-40

  • TE DATA W AVAILABLE THIS WEEK f

es I i 5 l 400 -- g O l "I O 313 s1t g3oO __ l l zu 1., 2'3 t sep l l... ll.,id,,,,.,,ila __,oo 1 - l i i i i i i i i i i i i i i i l I 3 10 17 24 31 7 14 21 28 5 12 19 26 2 9 16 23 OCT NOV DEC JAN INIT DISPITRANS TOTAL OPEN 1992 1993 TotM m2 d

l 1 i i 1ll 4l l snu s us a lii m i 30 ~ u m-m- ~ n=_ i 2 r 3 lii u = =4"*n" o o t 3 a f c.

c. e a

N9 S t 2 _ e 4A 9 m J u v _ 1 lii 2 D 9 3 7 E 23 u O 3. 4 9 9 D 23 2 9 i 0 7 A 1 =- 2 liI S i 6 m C i2 A uu m q-i 2 y T e i E m = o t n I W, = N e n f C t E w C s O i 12

t. o u

T N S i e A e-e T i 2 s a r m S O u i 2 8 p u G f C C O a* qD^ i t f o I T .x s R F i 0 t 2S ,2 N \\ u r a T N a se r n 1 e,3 ^ c c g'o

  • 1 es C

O m 3 3 s5 A E T s g I a \\a\\- g', i f n A u L T 's i 7 C 2 L e 1 O n E L .\\- N ' i o o3 oo 2 0 & A t s 2 M T w s s S ,k s" e 0 3 u A1 N \\' S x s g-, \\ N A i 2 a E 6 an oi I s \\ \\' N i 9 a TTG e 1 2 s SI P N N nt os E 9 s's N S9 a u atu wr i 2 a u I i 1 1 UL u sA sA s cc cc A, s K E w A A B uu uu i 5 c ii 22 s a E A ^ i 29 L S _ g. s m P = 2 5' 3 2 a9 i 2 u M 10 G E E 1 T .s s g i 5 U 1 A s H S i, 8 e 0 u s a C Y c?N i 0 N S 8 \\ N' N i 5 m A 2 u M 9 s \\ i o t t \\ ',' i f O L t J C ,N s .\\ 4 \\ s i 0 w.. ' nu i 2 7 Ng. ' g ,a 0 N i 2 U m J i 3 m 1 a s 0 0 0 0 0 0 0 0 0 0 0 0 0 u 0 0 0 0 0 0 0 0 0 0 0 0 a 0, 5, 0, 5 0, 5, 0, 5, 0, 5, 0, 5 m 6 5 5 4 4 3 3 2 2 1 1 0o s o r u u t s g sn u m ,flII ll( lI l!l;l i,II l' l 1

M M M M 'M M M M M M M M M M M M M M M COMANCHE PEAK STEAM ELECTRIC STATION AUDIT / SURVEILLANCE FINDINGS OPEN FINDINGS h DElNQUENTRESPONSES g 100 STATUS AUDITS SURVEILI.ANCES I 90 - ctosEo to 1

  • 1 - NUCLEAR PROCUREMENT OAS 92-123 (TUE-924580) EXTENS40N: 12'17,92 3-ISSUED o

o E A 92N,926.92M NN 1M93. 80 - OPEN 7 5 DEUNOUENT l RESPONSES o

  • 4 g 70 -

(>3oDAYS) 58 60 - t a5 f @ 50 - a g 40 - 8 g 30 - t-i 22 23 23 z - L 12 } 10 - [ 4 l ^ oo 00 00 00 o 'o 'o 'o 'o Qo I I I I i i l i i i 31 07 14 21 28 05 12 19 26 02 NOVEMBER DECEMBER JANUARY 1992 4 a

__ _ _. _ __ _ __.._.__ _ _ _ _ _____ _.m. _. _ _ _. _ _ _. I t COMANCHE PEAK STEAM ELECTRIC STATION l 4 UNIT 2 QC/ ENGINEERING BACKFIT OPEN UNSAT IR WORKOFF DISSUED D CLOSED E OPEN to to Pt . I B20-9 g15- $4 $4 $4 b il 10 - 2 e s '~ ] j y? b 5 oo o 0.i o if o eo oo 0 oo ,n 31 07 14 21 28 05 12 19 26 02 g NOVEMBER DECEMBER JANUARY 1 g 1992 QC PROGRAM's UNSAT IR's , l U'**"' U ' ' 5 I 20 15 - a 1 I s g 10 - LI 5-l 0 31 07 14 21 28 05 12 19 26 02 I NOVEMBER DECEMBER JANUARY 1992 ac m I 38

m m m-m m m m e e e m m e e e e e e COMANCHE PEAK STEAM ELECTRIC STATION UNIT 2 TOTAL PROJECTTU EVALUATION FORMS [-] -w 12 ae w a-r-russomu ""*"a"* m. u.r 1,080 - T ="a' M 0%A"= NN==

=== :no

n. . em a.asE OC e e 960 - e, e,4 e e e "a"^*'* *:. e e e 3 i.s .! e$,. sr . e 840 - = ""'r" ", 6 '2

==- N 9 9 8 9 9 720 -

== ==m er m. m, em 600 - 480 - 4sa ,3, 375 360 - 322 N 2sz 240 - 2o2 A = = 120 - fdl z, .5$jii P r- @r" 3, WE 42 y 'Aii. 2 M, l !ir mi: 553 ss .Hil@in s* 3a ~ i:s* I-7 m 2 0 .x.:-> i i i c i e i i 31 07 14 21 28 ! 05 12 19 26 02 NOVEMBER DECEMBER JANUARY 1992 ~ .hw

.M M M M M M M M M M M M M M M M M M M COMANCHE PEAK STEAM ELECTRIC STATION UNIT 2 PROGRAMATIC / REPETITIVE TUE'S WEEK ENDING 01/02/93 RESP. ORG. STATUS DATE E# SUBJECT RESP. PERSON E/C/D ISSUED TU ENGINEERING FOR FINAL DISPO. 92-5553 TEST RESULTS OF THERMOLAG (HARRISON) 01/09/93 06/19/92 92-6859 CRACKED WELDS WITHIN THE CT ENGINEERING FOR DISPOJIMPLE. 17/18/92 SYSTEM (HARRISON) POST 2RF02 TOTAL OPEN = 2 TARGET - 5 l i e

mzi 'lli, u~ ,t ,l liff e r-a K-BE il dll! e g-I $30l K5 #s j l i i i si a s I E If #lnggy !'E flilwllif I l i N ,;3 I l r 5 rs _!!,!"lple.1. ---.,_!= - - Y-._gu..b(hl-- !g 8 I ,s, g gy9--- I lhEh! t" ER 42-O ' 5'k g---"--h,[2l:4 JEs5 j., lh 1 5 3 it hal 1 i I "g- = e E or ek s s Vj"g

    • !Ealg;tIlm e

l:sa e.1 g ii" E c

("m a

I l ie i gE fs.r s ? SB f a[. g*i II e~ I !l.! j t ,a 8

n-88*

r a _ g gg W [ f J I _I ,,3 E ~ gl8 X .o g m y ,g g-m m m p, w g ,) I -" s a e I , is 3 E hk" e kElf kl s 3

i s

e i e 8 s 1 e. si .g a; p ag l i gg ( e e a g gi e p r, r um e n q, V y c-er c ,I U i 5 k E E 8 E 5r 8 le y ay a e a j

w e-a a

m =. g g w e I g, g-15 o e E V E E B '41 F W

^ l m n, I l'lli i se g il ls ; 1 ,11 I l Bi 9 s s 4hU [$ & Eb %mi! 3 I DHiddf i I L _ __ __ _ g$j -.g__E,WE E s VG E g g 3,L l P,gse E VG - 3 gg e r a a ca n I nW S lr$ s w h 5U d n g w w-s W *"J Eg f#d O V-8]! y1g $m:- 8

e!

-,s

  • EE g

h,y V, y, e-n d liav i I av w => ge i ei' EwN s E leat El!. d ag 2 z = z z z z z z z a$b I 8 8 e I s s M, n i .i i s s a, E st d"l s i os g. -e gc t1 [gi hi gjd L E i E I A 5 4 l I g>g3 g -g_ a _l E fc .e =r sc xe e w gs Ef 8@ 3 a gi n e g g d A B 9. bE g-5 9 I 55g! mgt se em ,a-s d 3 g L e" -l: mg gby gge t@@5 l-5 W e

g g8 B

= = 3 s0 e e e a u n -gk e g Y s) 2 ~m s{g gwQ @ 'E A de d W I-b6 g1 E.ge Eg~ ggs u e sa na ms uta d USA $na {t e <a s -.e gra bEA A m l 42

1 jil1!j,-IIIj)

3: g. a=_ e - m m e 2 C 5 I i RT D M, I T t N CU er E a LS ymM"R!M aF m I EES U P o T L C s a E" p=*" T E = I j C y 2" a ) 9** 3 nu 3, / 8 o* 3 sr T l F3 e e 1/ ( t t 2 v v E r 1 AC v 3 Ir r RR 0' S9 y a CN c 5D-m ) D 8 R e U "T3 t tam 3 a 8 fT v C e n t C o 9 s. rT pP { l l

  • e l

l' R. 3P Y,g a { N2 I" AT DC Jl iI 2 RL2 UU C* / , V 8D< jf R t I A K 'a = 3 t U w"3$ C7uC a 2 n S [S rf I 5 S-l C* n C C 9 $A D2/ 1 c C R r Ca* " ?,, p r( M r I 2 R T7 1 r f 1 s M e W *'7 - g N - o,, L a u IS m t t t ./ 7 n c I =P2t2 3 T "'N m"" C M Is t 3P1 E n9 UU G IN c, SS v/ C M 1 TD H G E v I t D RL y / NR I 32 P g $1 2c N,,, R t i t "1 C C s LML D I Y a L to I t ,ei N YT L C Cv r "" I V sMt" a R G a Rv v5 R P" VRt R T s 5 N NR e U a C

  • R rA D it DAC G

W N R' I P LN*"" '2 TA T U A3N e E 3 I 3 p t t

  • c U*

c/ ts J a t s t B H E" r3 To sN"" e v C U C C y t N 1 I u S R 0 r s I N 0 R MP C o 3 3C 2 1 fps 9 UF K cvyE a ei U SD C/ y, O m r * "" sat ,T-Eam* t Ft rmZ" S 2 C-: w EL i N T C v eE 4 TR R e U t tT p N r t

  • a g&

D R Ea erL ta aD E RA T C-D Dr P iramt E T PI T R f a p F oT* 2 C VT nL E t L gt E t5 gO c t D D; e gag cm" D T s t 2 Et Wr t 4T c nz t-B f eR= Dt T Pa r0C n.t5"" RL r LW I T p t - rtT T C a-e rs E nK P C3 4 i mm 3 t P RC PS gD C2 ttgat n G 3W sRgmT o s U IT F e C ts A S D& 5 i E eNeTD C P e tt5L E: te' s DT t rGT CN Tcem TC T D "' '" V AA-E" CLeu N A t TIC ta L OPst <o<C='" M'"' Tt cTO it r iCL tt 3 v&E Lt v s2a E LJ vc L% t t TC m a P3 P T AL Y, R 7 P 2

  • PM C

a t wit e MA vSD FOc s E t Cm't" 9 H O tCP i s 9 E1 gm Dt I7 N y N N N y N N N y Y n N e, m R

  • ra gm Y

y Y Y N y Y N Y y Y y Y ft r Rn c E TaD e s 2 e 5 s c 5 e 2 E e P. G 1 8 e 7 7 e NUD H? 9 D 9 5 9 r 7 1 C 2 m mRs V- %8 m Ke 3 R I 6 S1 m w e LNe: ) l 1 N. Ee e n 7 e 5 O t s tc L - T L L suG m M t = ta A o u# = c u

  • Y 1

C% T E T K R V A C Y D T Ct N t T A7 t M g u t tR R RD p t R K a" u A r r s U BU M t t o' a c t E C T L t M i 8C a G a U I iz T R S r s sTr P C u 1 K s s 4 u 1 0N B 7 N r e 0s .C 9 9E E 3 T N s R N t J D 3 I D R C 8 S T o eo sL 8t e 9 9e I I 3 t N L K .m i T v a s NI ND m C S C AT i N T mm Nm at P l t I Et t I Y A 7) G a> A _Aw s i T T T kap T S Sf ) c C T t Tu t u T E A E L Y) a2 r R) a Pe Bp A rT EP rD 3 iv L C L C2 1 L KDt v L 2 A 2 T2 2 a 4 :t DPn u tPn G uM As ua 1 I t L. ( A; 1r m tI Ln NI r i C gn Je O C c Ni OUe t a2u N u i t RT BT c t 3 t u. / A C r C U / R / s m e sG Rr sr a / I / A A3 A s/ M/ / E t T9 iT 9 s N s 2 BR< s T 3 mr. T A, CR1 CR+r G4 7 a V2 nae ta A3 3 w C P 3 Ct, Cs3 T.WC WSM D T I - T - T - E - E3 - e - t 1 Rc c R NS HU u GR SM mP+ NR- = v *- A C c NC BFc Pe e L I _N L E aw i

o p: 2 y Mr ~- ene P C G N M C I j RT I5S I 4, T sE N DI E U C T P E I IV i; a LS L I E T 42., E &C M r C I S A g2 UP A gFi e T ot 1 am a 7g_3; t 9 V E p i r!2y v ay T rd N m E u R e5 E R 3 r E 9

  • m M

j UT / TT:1 E CN s t E / s L z R n a N'ai V m l iI 3 T E Im" 9 Ti IR t 9 l l tI ll 1- { ll l VO zlgg l [ t M i D (1 RE:T EP Dc DC DP

a,

B Nr / g - Ut z yR n R Os wR R SE" NE e C P */E E Wm 3 RN s r'- s ai C ta e t P/ 3 5 3l: sI: t t RV t a EaCa4 ^ EAc 4 E n r s" C RR L 2 n 2

  • R L 2 N

t M 2 C 1 2 C 1 e E 1 D uO uO t r M l s *' t' TT TT v WL cIE pV 3' w W* E ER E A v 5D u* V l' r4 s G r CE a' T N M I A'* M' V8 a I R t

A V

I '" T* t N C. E F" v A t N *'"' R r =v O L T A m C T C M WT ( E I J P' G: 18 3 a E 5I i 1A U IA R S R E" C C T G R P N N 3N C

  • d i

fVR T. EA RS W I M I Y L 2 U 9 J ? M I r ma fr er N N N' N N N N N N Y nep M 7r l:a t ft Y Y Y Y Y Y v3 Y Y Y Y f"ri M 7 7 t 71 7 1 9 P E 2 wSU 6 8 ES M cI M ) 4x T C. m a R n r r p D T m T (P T A P a L O '8 R D c A 4 E t T A U L R2u m N S T P V E T E 5 r o EE IS I P +A U '2> Lz e o T D T VS N2 T U

  • J O

G A 0 tt. t M 0 S. 7 ) R E V E S 4 M ST) R ) r R t CC ) R2 tan 9 a ) 2 Tn s t a) P I T C G T ( 9 It(I m1 4c a CC D 9. z d I0 2 A 0 3 A4 c T ( owc c USic i AA c c EC 0 C vC EtC m i C n M r r t c NC 1 A 4 ST / / O 0 3o/ LT/ I 4. u w R s/ T RI/ e TA m3 WL L I 5 3 L / Bc4 B w / A 3 t 15 A7 P@ wC SmC E 3 R 4 R 3 N=4 AR4 t S 1 Iu1 CC1 V1c oar Cos 5N5 4r e o a D P e r rCr m a 1>1

m m m m m m W m m m m m m W SAFETEAh! CLASS I INVESTIGATIONS UNSUBSTANTIATED SUBSTANTIATED TOTAL OCT 2 2* 4 NOV 3 2* 5 DEC 2 4** 6

  • All of these were substantiated, but already addressed through existing corrective action.
    • One of four was substantiated not likely to have been captured without Safeteam process.

Three of four already captured by Project process. CPSES CORPORATE SECURITY SAFETY-RELATED CONCERNS INVESTIGATIONS OCTOBER NONE NOVENIBER NONE DECEhfBER NONI CORPORATE SECURITY GIOTLINE) RELATED INVESTIGATIONS OCTOBER NONT NOTThfBER NONT DECEMBER NONE 0; .}}