Text

....m.

MAY 0 91985 Docket No.-50-354

- Mr. R. L. Mittl, General Manager Nuclear Assurance and Regulation Public. Service Electric & Gas Company P. O. Box 570, T22A Newark, New Jersey 07101

Dear Mr.-Mitti:

SUBJECT:

USE OF NB-2510 0F SECTION III, 1983 EDITION, SUMMER 1983 ADDENDA FOR THE HOPE CREEK GENERATING STATION The staff has completed its review of the February 1,1985 Public Service Electric and Gas Company request for authorization to adopt the provisions of.NB-2510 in the 1983 Edition through the Summer 1983 Addenda of Section.III of the ASME Boiler and Pressure Vessel Code. The Code of Record for Hope Creek "is ASME Section III, 1974 Edition through the Winter 1974 Addenda to the Code.

The provisions of NB-2510 in the Summer 1983 Addenda permit the use of seam-

.less pipe, tubes, and fittings one inch. nominal-pipe size and less without examination by nondestructive methods and. deleted the additional design require-

-ments.of NB-3673 for unexamined pipe and tubing. The revisions were made to

, -eliminate inconsistencies in the Code. The Code of Record requires the additional requirements of NB-3673 be met if the: pipes, tubes, and fitting are to be excluded from nondestructive examination for two inch nominal pipe size and

,less.

We find the use of NB-2510, " Examination of Pressure Retaining Materials," in the.1983 Edition, Summer 1983 Addenda of Section III of the ASME Code to be acceptable for use at Hope Creek-provided all related provisions of the Code are adhered to.

Sincerely, Walter R.- Butler, Chief Licensing Branch No. 2 Division of Licensing cc: See.next page Distribution: 19ecketWiley NRC PDR Local PDR PRC System NSIC LBf2 Reading Ehylton DWagner Dewey, OELD -ACRS (16)

JPartlow BGrimes-

~EJordan RKirkwood, MEB h

/

/PM LB#2/DL/BC:

DWagner:lb WButler 05/3/85 05/3/85 8505200485 850509 PDR ADOCK 0500 4

a

MAY 0 91985 P

Docket No. 50-354 Mr. R. L. Mitti, General Manager Nuclear Assurance and Regulation Public Service Electric & Gas Company P. O. Box 570,.T22A Newark, New Jersey 07101

Dear Mr. Mitti:

SUBJECT:

USE OF NB-2510 0F SECTION III, 1983 EDITION, SUMMER 1983 ADDIWDA FOR THE HOPE CREEK GENERATING STATION The staff has completed its review of the February 1, 1985 Public Service Electric and Gas Company request for authorization to adopt the provisions of NB-2510 in the 1983 Edition through the Summer 1983 Addenda of Section III of the ASME Boiler and Pressure Vessel Code. The Code of Record for Hope Creek is ASME Section III, 1974 Edition through the Winter 1974 Addenda to the Code.

The provisions.of NB-2510 in the Summer 1983 Addenda permit the use of seam-less pipe, tubes, and fittings one inch nominal pipe size and less without examination by nondestructive methods and deleted the additional design require-ments of NB-3673 for unexamined pipe and tubing. The revisions were made to eliminate inconsistencies in the Code. The Code of Record requires the additional requirements of NB-3673 be met if the pipes, tubes, and fitting are to be excluded from nondestructive examination for two inch nominal pipe size and less.

We find the use of NB-2510 " Examination of Pressure Retaining Materials," in the 1983 Edition, Summer 1983 Addenda of Section III of the ASME Code to be acceptable for use at Hope Creek provided all related provisions of the Code are adhered to.

Sincerely, Walter R. Butler, Chief Licensing Branch No. 2 Division of Licensing cc: See next page Distribution:

Docket File NRC PDR Local PDR PRC System NSIC LBf2 Reading EHylton DWagner Dewey, OELD ACRS (16)

JPartlow BGrimes EJordan RKirkwood, MEB h

/

/PM LB#2/DL/BC DWagner:1b WButler 05/3/85 05/3/85

/

UNITED STATES

[

g NUCLEAR REGULATORY COMMISSION

/

g j

WASHINGTON. D. C. 20555

/

....+

MAY 0 9 ms Docket No. 50-354 Mr. R. L. Mitti, General Manager Nuclear Assurance and Regulation Public Service Electric & Gas Company P. O. Box 570, T22A Newark, New Jersey 07101

Dear Mr. Mitti:

SUBJECT:

USE OF NB-2510 0F SECTION III, 1983 EDITION, SUMMER 1983 ADDENDA FOR THE HOPE CREEK GENERATING STATION The staff has completed its review of the February 1,1985 Public Service Electric and Gas Company request for authorization to adopt the provisions of NB-2510 in the 1983 Edition through the Summer 1983 Addenda of Section III of the ASME Boiler and Pressure Vessel Code. The Code of Record for Hope Creek is ASME Section III, 1974 Edition through the Winter 1974 Addenda to the Code.

The provisions of NB-2510 in the Summer 1983 Addenda permit the use of seam-less pipe, tubes, and fittings one inch nominal pipe size and less without examination by nondestructive methods and deleted the additional design require-ments of NB-3673 for unexamined pipe and tubing. The revisions were made to eliminate inconsistencies in the Code. The Code of Record requires the additional requirements of NB-3673 be met if the pipes, tubes, and fitting are to be excluded from nondestructive examination for two inch nominal pipe size and less.

We find the use of NB-2510, " Examination of Pressure Retaining Materials,'" in the 1983 Edition, Summer 1983 Addenda of Section III of the ASME Code to be acceptable for use at Hope Creek provided all related provisions of the Code are adhered to.

Sincerely, Walter R. Butler, Chief Licensing Branch No. 2 Division of Licensing cc: See next page

p

'Mr.' R. L. Mitti..

. Hope Creek Gen 2 rating Station

'Public Service Electric & Gas Co.~

.o-E Susan C. Remis cc: : Gregory Minor. -

Division of Public Interest Advocacy Richard Hubbard-.

Dale Bridenbaugh New Jersey State Department of MHB Technical Associates-the Public Advocate

1723 Hamilton Avenue, Suite K Richard J. Huges Justice'Comples

. San Jose, California 95125 CN-850 Trenton, New Jersey -08625 Troy _B. Conner, Jr. Esquire Office of Legal Counsel Conner & Wetterhahn Department of_ Natural Resources 1747 Pennsylvania Avenue N.W.

and Environmental Control Washington, D.C.

20006 89 Kings Highway P.O. Box 1401 Dover, Delaware 19903

. Richard Fryling, Jr., Esquire Mr. K. W. Burrowes, Project Engineer Associate General Solicitor Bechtel Power Corporation Public Service Electric & Gas Co.

50 Beale Street P. O. Box 570 TSE P. O. Box 3965 Newark, New Jersey 07101 San Francisco, California 94119

.Mr. R. Blough Mr. J. M. Ashley Resident Inspector Senior Licensing Engineer U.S.N.R.C.

c/o Public Service Electric & Gas Co..

P. O. Box 241

. Bethesda Office _ Center, Suit 550 Hancocks Bridge, New Jersey 08038 4520 East-West Highway l

Richard F. Engel Deputy Attorney General Mr. A. E. Giardino Division of Law' Manager - Quality Assurance ESC Environmental Protection Section Public Service Electric & Gas Co.

Richard J. Hughes Justice Complex -

P. O. Box A CN-112P Hancocks Bridge, New Jersey 08038 L

Trenton, New Jersey 08625 Mr. Robert J. Touhey, Mr. Anthony J. Pietrofitta Acting Director-General Manager

-DNREC - Division of Power Production. Engineering Environmental Control Atlantic Electric 89 Kings Highway-1199 Black Horse Pike P. O. Box 1401 P1 asantville, NJ 08232 Dover, Delaware 19903 Mr. Thomas E. Murley

[_

Mr. R. S. Salvesen U. S. NRC, Region I L

General Manager-Hope Creek Operation 631 Park Avenue

.Public_ Service Electric & Gas Co.

King of Prussia, Pennsylvania 19406 E

P.O. Box A Hancocks Bridge, New Jersey: 08038 l

-Mr. B. A. Preston.

Project Licensing Manager

.Public Service Electric & Gas Co.

P. 0.- Box 570 T22A Newark, New Jersey 07101 l

L