ML20127F482

From kanterella
Jump to navigation Jump to search
Forwards Insp Repts 50-259/85-21,50-260/85-21 & 50-296/85-21 on 850401-04 & Notice of Violation
Date released: 05/20/2020 Download: ML20127F482


Insp Repts 50-259/85-21,50-260/85-21 & 50-296/85-21 on 850401-04.Violation Noted:Inadequate Design Calculations on Pipe Support HPCI R-86,R2
ML20127F513
Person / Time
Site: Browns Ferry 
Issue date: 04/19/1985
From: Blake J, Liu W
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To:
References
Download: ML20127F513 (6)
Notice of Violation from Insp on 850401-04
ML20127F493
Person / Time
Site: Browns Ferry 
Issue date: 04/26/1985
From:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To:
References
Download: ML20127F493 (4)
Forwards Insp Repts 50-259/85-21,50-260/85-21 & 50-296/85-21 on 850401-04 & Notice of Violation
ML20127F480
Person / Time
Site: Browns Ferry 
Issue date: 04/26/1985
From: Verrelli D
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To: PARRIS H G
TENNESSEE VALLEY AUTHORITY
References
Download: ML20127F480 (2)