ML20127F208

From kanterella
Jump to navigation Jump to search
Forwards Insp Repts 50-424/92-27 & 50-425/92-27 on 921025-1128.One non-cited Violation Noted
ML20127F208
Person / Time
Site: Vogtle  Southern Nuclear icon.png
Issue date: 12/21/1992
From: Herdt A
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To: Hairston W
GEORGIA POWER CO.
Shared Package
ML20127F210 List:
References
NUDOCS 9301200173
Download: ML20127F208 (4)


See also: IR 05000424/1992027

Text

- _ - _ _ _ _ _ _ _ _ .

- - - - - - - - - - - - -

'

'

l5

A ko

.

,

-

a

i)Y

)

)DJ

.

UEC 211992

Docket Nos. 50-424, 50-425

License Nos. NPF-68, NPF-81

Georgia Power Company

ATTN:

Mr. W. G. Hairston, 111

Senior Vice President -

Nuclear Operations

P. O. Box 1295

Birmingham, AL 35201

Gentlemen:

SUBJECT:

NRC INSPECTION REPORT NOS. 50-424/92-27 AND 50-425/92-27

This refers to the inspection conducted by B. Bonser of this office on

October 25 - November 28, 1992.

The inspection included a review of

activities authorized for your Vogtle facility. At the conclusion of the

inspection, the findings were discussed with those members of your staff

identified in the enclosed report.

Areas examined during the inspection are identified in the report. Within

these areas, the inspection consisted of selective examinations of procedures

and representative records, interviews with personnel, and observation of

activities in progress.

The enclosed Inspection Report identifies activities that violated NRC

requirements that will not be subject to enforcement action because your

efforts in identifying and correcting the violation meet the criteria

specified in Section VII.B. of the Enforcement Policy.

-

In accordance with 10 CFR 2.790(a), a copy of this letter and its enclosure

will be placed in the NRC Public Document Room.

Should you have any questions concerning this letter, please contact us.

Sincerely

ORIGINAL CPt0 BY

ALAN R. HNT

Alan R. Herdt, Chief

Reactor Project.s Branch 3

Division of Reactor Projects

Enclosure:

NRC Inspection Report

cc w/ encl:

(See page 2)

9301200173 921221

PDR

ADOCK 05000424

G

PDR

\\

E --

- - - - - - - - - - - - - - - _

-

- _ - - - -

J

.

. .

,

.

.

Georgia Power Company

2

cc w/ enc 1:

R. P. Mcdonald

Executive Vice President -

Nuclear Operations

P. O. Box 1295

Birmingham, AL 35201

C. K. McCoy

Vice President-Nuclear

Georgia Power Company

P. O. 1295

Birmingham, AL 35201

_

W. B. Shipman

General Manager, Nuclear

Operations

P. O. 1600

Waynesboro, GA 30830

J. A. Bailey

Manager-Licensing

Georgia Power Company

P. O. Box 1295

Birmingham, AL 35201

Nancy Gibson Cowles

Office of Consumers' Utility Counsel

84 Peachtree Street, N.W., Ste. 201

Atlanta, Georgia 30302-2318

Office of Planning and Budget

-

Room 615B

270 Washington Street, SW

Atlanta, GA 30334

Office of the County Commissioner

Burke County Commission

Waynesboro, GA 30830

Harold Reheis, Director

Department of Natural Resources

205 Butler Street, SE, Suite 1252

Atlanta, GA 30334

Thomas Hill, Manager

Department of Natural Resources

4244 International Parkway

Suite 114

Atlanta, GA 30354

cc:

Continued see page 3

9

,....

';

_

'

.

. Georgia Power Company

3

-cc:- Continued

Attorney General

Law Department-

132 Judicial Building

Atlanta, GA 30334

Ernie Toupin, Program Director

of Power Production

Oglethorpe Power Corroration

2100 East Exchange Place

Tucker, GA 30085-1349

Charles A. Patrizia, Esq.

Paul, Hastings, Janofsky & Walker

12th Floor

1050 Connecticut Avenue, NW

Washington, D. C.

20036

1

i

l

,

i

!

l-

,

-

u

i

- , .

in

- . . - .

- - , , - ,

, , , . .

-

,.

,

, - . . . . - - - - - -

.-.

'

.

- _ _ _ - _ _ _ - - _ _ _ _ _ - _ _ - . . . _ _

_-___.

' ' ,

.

,

DEC 211992

Georgia Power Company

4

bcc w/ encl:

J. Johnson, Rll

D. Seymour, RIl

D. llood, NRR

P. Skinner, Ril

A. Flerdt, Rll

Document Control Desk

NRC Resident Inspector

U.S. Nuclear Regulatory Commission

P. O. Box 572

WaynEsboro, GA 30830

FILE:

G:\\VG222RPT.DAS

Y,

.

RII

-7yz y ,

+

0Seymour

Phlinner

12/11/92

12'/ /92