Text
-
A---- m ------- ____________ _______ _ m N
CERTIFICATE 08 COMPLIANCE l to CFe r FOR RADIOACTIVE MA.*ERIALS PACKAGES lI 1 a. CERTIFICATE NUMBER.
D. REVISION NUMBER c PACKAGE lOENT FICATION NUMBER d PAGE NUMBER e TOTAL NUMBER PAGES i
9006 8
USA /9006/B(U) 1 2
1 7 rnEA a
.I ll. a. Tns certet. cat.. issued to certify inat ine pac = aging and contents descnoed m atem s meiow. ' meets ineappi camie safety standards set fortn in Titie io. code
!N l
- of Federal Regulations, Part 71, *Packagmg of Radioactive Matenais for Transport and Trensportation of Radioactive Matenal Under Certain Conditions."
'3 kl I
- b. Tnis certificate does not relieve the consignor from compliance with any requirement of tne regulations of the U S. Department of Transportation or other lj
- appi.cacie regulatory agencies. menuding tne government of any country inrougn or into whien the package wisi de transported.
il Ii
!B li
'I i
!i if.* 'a"'*re'E,"If$^e'v'$8 E'8f" e."r'* ' ^ *^" ^**"*i T7tE flo'Io'Sf*Cff o@'Elo^T7EA FCATION
- i 1
- I liTech/ Ops', Inc.
Tech / Ops Inc. application jI l1,40 North Avenue dated March 20, 1985, as supplemented.
j i
jlBurlington, MA l
01803 j'
l li
- c. ooCxEr Nuueca J71-9006 l 4 CoNo:TIONS j
- in certificate is conditionas upon fuifaiing the requirements of to cFR Part 71, as applicable. and tne conditions specified beiow
.Jj s b
1 d
1f
- 1; (a) Packaging
.I
- s (1) Model No.: =AI 500 SU-l
{l' I
i (2) Description
!n 1
jf I
- 1 A radiographic source changer consisting of a welded 10-gauge stainless j
11 steel box, approximately 5" wide x 6" high x 11" long.. - The source jI j'
changer has a positive closure hinged flat plate cover and a depleted ll uranium shield. Two titanium tubes are positioned in the center of lg jl the depleted uranium and house the source capsules and the source ju l
1,_
cable assemblies. The two openings are closed by threaded caps. The p;I
.Ji gross weight is approximately 60~ pounds.
i
- I (3) Drawings l
l l, The packaging is constructed in accordance with Tech / Ops, Inc.
l,l
' ll Drawing Nos. AIS00SU90, Sheets 1, 2, and 3 of 3; AIS00SU91, I
l.
AIS00SU92; and optional Drawing No. AIS00SU93.
- I i1 lI f
j (b) Contents l
,5 3
(1) Type and form of material lg
't j
Iridium 192 as a sealed source which meets the requirements of special ju i].1 fonn radioactive material.
j (2) tiaxinum quantity of material per package flf 11 i
1l 120 curies 8
T it
' I!
ll i
g;
't I!
R 3
'5,W I'l gL B505170093 e50506 g
C PDR
!N i!
...,r, a.
g
s
..,,.,,,,,,,,,:,.,,,,,,,..,-i.;s,,,,,
,,,.s si j
c s 1
^
C:NDITl:NS (continued)
!>J l
it.
(!W LPage 2.- Certificate No. 9006 - Revision No. 8 - Docket No. 71-9006 j
1,
!g l
lj:
l l 6..
The source shall be positioned within the titanium tubing by a source cable E
l assembly which meets the parameters shown in Tech / Ops, Inc. Drawing 4
i Nos. 42402-1, Rev. D, and 42402-4, Rev. A.
g
't l#
j 7.
The name plate shall be fabricated of materials capable of resisting the fire R
- i test of 10 CFR Part 71 and maintaining its legibility.
iE
! q l :! 8.
The package authorized by this certificate is hereby approved for use under the
}
}
general license provisions of 10 CFR 571.12.
lg.
k l9 79.
- Expiration date: May 31,1990.
.c.
a 7,_, '_,
- u.,., -
,R
,sh
. { f' r j$
j f
. ([*
REFERENCES lE
'a NJ 1
E
.a gj Tech / Ops, Inc. application' dated March 20, 1985.
q sN i
1 Supplement dated: April 19,1985.;' x i
3 s
~
~ FOR THE U.S. NUCLEAR REGULATORY COMf11SSION
!g
' f)
'E lg
= ;!
.M
- l q_
q c3 a 3__ 7
>g e
~
j n
I 1
~ '
L Charles -E. MacDouald, Chief n
?
~.
p,
Transportation Certification Branch ju
- Division-of Fuel Cycle and if
- ]
. Material ' Safety, NMSS ia
-j
~
'I NAY061985
- J, Da te:
ltjt 1
,d If f
IN 1!
l5
.1,
- b 1
- E
- T
- D
- ]
!B 1
N I
,N 1
1 l
3 l
T E
l y#
1 i______________________________________________e______
1
[
. yo "%,p.
8(j UNITED STATES
.g
- % Q)g( (d; E g
NUCLEAR REGULATORY COMMISSION f
WASHINGTON, D. C. 20555
\\..v Transportation Certification Branch Approval Record Model No. AI 500 SU Package Docket No. 71-9006 By application dated fiarch 20, 1985, as supplemented April 19, 1985, Tech / Ops, Inc. requested renewal of Certificate.of Compliance No. 9006.
This Certificate of Compliance was originally issued on the basis of an application prepared by Automation Industries, Inc. Tech / Ops, Inc. has acquired the gamma radiography equipment business from Automation Industries, Inc. as disclosed in Automation Industries letter of November. 16, 1984.
Tech / Ops has submitted a consolidated application which incorporates the original application and all pertinent supplement infprmation in support of their request for renewal of the certificate.
Tech / Ops, Inc. has prepared a set of packaging drawings which replace the previously referenced Automation Industries, Inc. drawings. The consolidated application and packaging drawings were reviewed and a determination-made that all' pertinent information as given in the original application as supple-nented ^and the packaging drawings has been incorporated into the consolidated j>
application.
Based on the staff's findings as reported in the Safety Evaluation Report dated flovember 15, 1973 and Addendum No. I dated February 4,1974 and the consolidated safety analysis report as supplemented, the staff concludes that the requirement for renewal of the Certificate of Compliance has been satisfied,
& fW N
Charles E. MacDonald, Chief Transportation Certification Branch Division of Fuel Cycle and Material Safety, Nf1SS MAY0611B5 Date:
. -.