ML20127C506
| ML20127C506 | |
| Person / Time | |
|---|---|
| Site: | Susquehanna |
| Issue date: | 02/22/1985 |
| From: | Thompson H Office of Nuclear Reactor Regulation |
| To: | Starostecki R NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I) |
| Shared Package | |
| ML20127C509 | List: |
| References | |
| TAC-55093, TAC-55094, NUDOCS 8503010345 | |
| Download: ML20127C506 (1) | |
Text
_ _ _ _ _ _ - - _
l y%
9
- k UNITEDSTATES
+'
g NUCLEAR REGULATORY COMMISSION
- tii,
l WASHINGTON, D C. 20555
~s., *****/
FEB 221985 Docket Nos.: 50-387/388 MEMORANDUM FOR:
R. 'Starostecki, Director Division of Project and Resident Programs, Region I FROM:
Hugh L. Thompson, Jr., Director Division of Licensing Office of Nuclear Reactor Regulation
SUBJECT:
RESPONSE TO RE0 VEST FOR TECHNICAL ASSISTANCE FROM REGION I - SUSQUEHANNA (TACS 55093/55094) TIA 84-45
Reference:
Memorandum for D. Eisenhut from R. Starostecki, "Susquehanna Steam Electric Station, Units 1 A 2, Vacuum Areaker Valve Position Indi-cation," dated May 29, 1984 regulatory position set forth in the Standard Review Plan (SRP) y NRR of the In the referenced memorandum, Region I requested an assessment b 6.2.1.1.C.
This issue relates to the allowable bypass leakage via the vacuum breakers between the drywell and the wetwell air space region. The concern deals with the lack of test accept *ance criteria for the set points of the position indi-cation switches that are mounted on the drywell-to-suppression chamber vacuum breakers.
Provided as the Enclosure to this memorandum is the Safety Evalu-ation provided by NRR.
If you have any additional questions, please contact the project manager M. Campagnone x27235.
0*L
- tsL,.
es I
/lughL.
omps
., Director
}OSDivisionofLicensing Office of Nuclear Reactor Regulation
Enclosure:
As stated CONTACT:
M. J. Campagnone X27235 g
w
,