Forwards SER Re Allowable Bypass Leakage Via Vacuum Breakers Between Drywell & Wetwell Airspace Region in Response to 840529 Request
ML20127C506
Person / Time
Site: Susquehanna  Talen Energy icon.png
Issue date: 02/22/1985
From: Thompson H
Office of Nuclear Reactor Regulation
To: Starostecki R
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
Shared Package
ML20127C509 List:
References
TAC-55093, TAC-55094, NUDOCS 8503010345
Download: ML20127C506 (1)


Text

_ _ _ _ _ _ - - _

l y% 9

+' UNITEDSTATES

!.' *kg NUCLEAR REGULATORY COMMISSION tii,

l WASHINGTON, D C. 20555

~s., *****/

FEB 221985 Docket Nos.: 50-387/388 MEMORANDUM FOR: R. 'Starostecki, Director Division of Project and Resident Programs, Region I FROM: Hugh L. Thompson, Jr., Director Division of Licensing Office of Nuclear Reactor Regulation l

SUBJECT:

RESPONSE TO RE0 VEST FOR TECHNICAL ASSISTANCE FROM REGION I - SUSQUEHANNA (TACS 55093/55094) TIA 84-45

Reference:

Memorandum for D. Eisenhut from R. Starostecki, "Susquehanna Steam Electric Station, Units 1 A 2, Vacuum Areaker Valve Position Indi-cation," dated May 29, 1984 In the referenced memorandum, Region I requested an assessment b regulatory position set forth in the Standard Review Plan (SRP) y NRR of the 6.2.1.1.C.

This issue relates to the allowable bypass leakage via the vacuum breakers between the drywell and the wetwell air space region. The concern deals with the lack of test accept *ance criteria for the set points of the position indi-cation switches that are mounted on the drywell-to-suppression chamber vacuum breakers. Provided as the Enclosure to this memorandum is the Safety Evalu-ation provided by NRR.

If you have any additional questions, please contact the project manager M. Campagnone x27235. ,

es 0*L  : tsL,.

I omps ., Director

/lughL.

}OSDivisionofLicensing Office of Nuclear Reactor Regulation

Enclosure:

As stated CONTACT: M. J. Campagnone X27235 g