8[panr, o

o UNITED STATES g

NUCLEAR REGULATORY COMMISSION n-o g

WASHINGTON, D. C. 20555 r

%...../

MAR 0 5198)

Mr. Steven C. Sholly Technical Research Associate Union of Concerned Scientists 1346 Connecticut Avenue, NW IN RESPONSE REFER Washinaton, DC 20036 TO F01A-85-69

Dear Mr. Sholly:

This is in response to your letter dated January 28, 1985, in which you requested, pursuant to the Freedom of Information Act (F0IA):

A.

All data reports and technical reports concerning the steel containment test series at Sandia National Laboratories, B.

All NRC documents evaluating the results of the steel containmer,t test series, and C.

All documents generated by any peer review committees established to advise NRC and/or Sandia National Laboratories concernino the performance of the steel con'ainment test series and interpretation of the test series resul:s.

The documents listed cn the enclosed appendix are ir response to category (C) of your request.

These documents are being placed in the NRC Public Document Room (PDP) file folder F0IA 85-69.

Vc presently have a pending F0IA request which addresses documents requested in categories A and B of your request.

A partial reply has been made,to this request and may be accessed at the PDR by requesting file folder F0IA-84-940.

Copies of the request and our reply are enclosed.

We expect to complete F01A-84-940 by the second week of March.

The completion of F01A-84-940 will also complete the NRC's response to your request.

Sipce ely, i g

J. M.

elton, Director Division of Rules and Records Office of Administration

Enclosure:

As stated h

--69

l Re:

F01A-85-69 APPENDIX 1.

02/26/81 Memo to Advisory Group, Safety Margins for Containments from Walter A. Von Riesemann (1 paae) 2.

03/10/81 Meeting Highlights agenda fonn for 03/27/81 meeting (3 pages) 3.

05/21/81 Memo to Advisory Group, Safety Margins for Containments from A.W. Dennis (3 pages) 4.

05/27/81 Memo to Containment Advisory Group from Walter A. Von Riesemann, subject Chicago meeting, June 9-10, 1981 (5 pages) 5.

08/20/81 Memo to Advisory Group, Safety Marcins of Containment from A 4 Dennis, summary of the Advisory Group discussion held on June 9-10, 1981 (7 pages) 6.

10/26/81 Letter to James F. Costello from T.E. Blejwas Systems Safety Technology (2 pages) 7.

01/05/82 Memo to Containment Advisory Panel from Thomas E. Ble.iwas Summary of meeting on September 17-18, 1981 (14 pages) 8.

05/03/82 Distribution memo from A.W. Dennis on Steel Reactor Containment Model -- Criteria for Design, Fabrication and Erection (11 pages) 9.

05/26/89 Letter to A.W. Dennis from W.E. Baker on criteria for design, fabrication and erection of the tanth-scale steel reactor containment model (2 pages)

10. 05/26/82 Letter to A.W. Dennis from Roger F. Reecy re: Steel Peactor Containment Model Criteria for Lesign, Fabrication and Erection (4 pages)
11. 05/27/82 Letter to A.W. Dennis from J.J. Ucciferro re: Steel Reactor Containment Model, Criteria for Design, Fabricatior.

and Erection (2 pages)

12. 05/28/82 Memo to A.W. Dennis re: Steel Reactor Containment Criteria for Design, Fabrication and Erection (2 pages)
13. 06/01/82 Letter to A.W. Dennis from Peter Cybulskis (2 pages)
14. 07/13/82 Letter to A.W. Dennis from Roger F. Reedy, P.E.,

re: Peer Review Comment on large Steel Model (3 pages)

15. -08/11/82 Letter to A.W. Dennis from John D. Stevenson (1 page)

O Re:

F0!A-85-69 APPENDIX l 16. 08/17/82 Distribution Memo from A.W. Dennis, with 2 enclosures (5 pages)

17. 09/13/82 Memo to Containment Integrity Peer Review Group from i

Walter A. Von Riesemann (7 pages) 18.

10/19/82 Letter to Dr. Walter A. Von Riesemann from W.E. Baker with letter to Dr. James F. Costello attached (3 paces) 19.

01/11/83 Letter to Mr. Thomas J. Ahl from T.E. Blejwas, with Containment Integrity Peer Review Group attached (4 pages)

20. 02/01/83 Letter to Mr. Thomas J. Ahl from T.E. Blejwas, with enclosure (3 pages)
21. 02/24/83 Agenda for Peer Review Group Containment Integrity Program (2 page)
22. 05/02/83 Memo to Containment Integrity Peer Review Group from R.T. Reese, with enclosures (7 pages)
23. 06/17/83 Memo to Containment Integrity Peer Review Group from R.T. Reese with enclosure (10 pages)
24. 07/26/83 Letter to Mr. Thomas J. Ahl from Thomas E. Blejwas with enclosures (9 pages) 25.

11/10/83 Memo to Containment Integrity Peer Pevier Committee from J. Jung re: notes from the August 2-5, 1983 Peer Review Group Meeting (137 pages)

26. 03/13/84 Memo to Containment Integrity Techincal Review Panel from Walter A. Von Riesemann re: April 17-18, 1984 meeting (2 pages)
27. 04/12/84 Distribution memo from W.A. von Riesemann on Containment Integrity Peer Review Panel (1 page)
28. 04/16/84 Memo to Containment Peer Review Committee from Walt von Riesemann(1page)
29. 04/17/84 Final Aaenda for Containment Integrity Peer Review Panel (4 pages)
30. 07/02/84 Memo to The Peer Review Committee from C.V. Subramanian (1page) 31.

11/30/84 Memo to Containment Integrity Peer Review Committee from Walter A. von Riesemann re: Albu September 11-12, 1984 (3 pages) querque Meeting, 32.

12/11/84 Tentative Agenda'for Peer Review Committee (2 pages)

__,