ML20126L737
| ML20126L737 | |
| Person / Time | |
|---|---|
| Site: | Hatch |
| Issue date: | 07/18/1985 |
| From: | Stolz J Office of Nuclear Reactor Regulation |
| To: | Beckham J GEORGIA POWER CO. |
| Shared Package | |
| ML20126L742 | List: |
| References | |
| GL-83-28, NUDOCS 8508010004 | |
| Download: ML20126L737 (2) | |
Text
.
July 18,1985 Dockets Nos. 50-321 DISTRIBUTION and 50-366
HThompson Vice President - Nuclear Generation OELD Georgia Power Company EJordan P. O. Box 4545 BGrimes Atlanta, Georgia 30302 JPartlow l
Dear Mr. Beckham:
We have completed our review of Georgia Power Company's (GPCs) November 7, 1983 and February 29, 1984 responses to Generic Letter 83-28 with respect to Item 1.2 Post-Trip Review Data and Information Capability for Hatch Units 1 and 2.
Based for our review, we have concluded that the post-trip review data and information capability for Hatch Units 1 and 2 are acceptable.
1 A copy of our Safety Evaluation is enclosed. The Safety Evaluation was l
prepared by the staff based upon its review of the above submittals input for l
its contractor, Science Applications International and discussions with GPC representatives on June 11 and 12, 1985.
j l
Sincerely, a
- omona. : a m or an 1.
ta John F. Stolz, Chief Operating Reactors Branch #4 i
Division of Licensing t
4
Enclosure:
Safety Evaluation cc w/ enclosure:
i See next page r
l i
}
- DL OR
- DL l
vpnbark;cr JSt 7/ly/85 7/
5 P
> o' Mr. J. T. Beckham, Jr.
Georgia Power Company Edwin I. Hatch Nuclear Plant, Units Nos. I and 2 Cc:
G. F. Trowbrid Shaw, Pittman,ge, Esq.
Potts and Trowbridge 1800 M Street, N.W.
Washington, D.C.
20036 Mr. L. T. Gucwa Engineering Department Georgia Power Company P. O. Box 4545 Atlanta, Georgia 30302 Mr. H. C. Nix, Jr., General Manager Edwin I. Hatch Nuclear Plant Georgia Power Company P. O. Box 442 Baxley, Georgia 31513 Mr. Louis 8. Long Southern Company Services, Inc.
P. O. Box 2625 Birmingham, Alabama 35202 Resident inspector U.S. Nuclear Regulatory Commission Route 1 Baxley,. P. O. Box 279 Georgia 31513 Regional Administrator, Region 11 U.S. Nuclear Regulatory Commission, 101 Marietta Street, Suite 3100 Atlanta, Georiga 30303 Mr. Charles H. Badger Office of Planning and Budget Room 610 270 Washington Street S.W.
Atlanta, Georgia 30334 Mr. J. Leonard Ledbetter, Comissioner Department of Natural Resources 270 Washington Street, N.W.
Atlanta, Georgia 30334 Chairman Appling County Comissioners County Courthouse Baxley, Georgia 31513
-