i FINAL REPORT Chemical Characterization of Organic lon-Exchange Resins Supplied by Arkansas Power and Light Company L. G. Morgan R. D. Scheele J. L. Ryan D. L. Stewart E. C. Martin K. D. Wiemers May 1985 Prepared for the Arkansas Power and Light Company under Contract 2311205862 i

OBattelle Pacific Northwest Laboratories N

hDR O

60 S

PDR 4

a

t-l L

?

LEGAL NOTICE This report was prepared by 8attelle as an account of sponsored research activities. Neither Sponsor nor Battelle nor any person acting on behalf of either:

MAKE5 ANY WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, with respect to the accuracy, completeness, or usefulness of theinformation containedin this report,or that the use of any informa-tion, apparatus, process, or composition disclosed in this report may not infringe privately owned rights; or j

Assumes any liabilities with respect to the use of, or for damages result-

)

ing from the use of, any information apparatus, process, or composition f

disclosed in this report.

l l

L l

I

^

. m.,

FINAL REPORT CHEMICAL CHARACTERIZATION OF ORGANIC ION-EXCHANGE RESINS SUPPLIED BY ARKANSAS POWER AND LIGHT COMPANY L. G. Morgan J. L. Ryan E. C. Martin R. D. Scheele D. L. Stewart K. D. Wiemers May 1985 Prepared for the Arkansas Power and Light Company Little Rock, Arkansas 72203 under Contract 2311205862 Battelle Pacific Northwest Laboratories Richland, Washington 99352

SUMMARY

Evidence for an exothermic reaction in a bed of dewatered ion exchange resin was observed at Arkansas Power and Light Company ( AP&L), Arkansas Nuclear No. One (ANO) on January 15, 1983. Battelle, Pacific Northwest Laboratories (Battelle-Northwest) has conducted extensive studies in support of Arkansas Power and Light Company in an effort to determine the cause of this exothermic event.

No unequivocal cause of the exothermic event detected in a bed of dewatered ion exchange resin on January 15, 1983, at Arkansas Power and Light Company, Arkansas Nuclear No. One was determined.

Studies conducted by Battelle, Pacific Northwest Laboratories included: 1) extensive analytical analyses to determine the cations and anions present in resin samples submitted by AP&L; 2) a determination of whether oxidants, reductants, acids, or bases were present in the resin samples submitted by AP&L; 3) determination of " free" organics; 4) thermal stability of the resins used by AP&L;

5) solidification of resins in cement; 6) an evaluation of microorganism growth in resins; 7) simulated dewatering tests; and 8) a thermodynamic evaluation of resin stability. None of the studies conducted indicated a definitive cause for the exothermic event.

However, the studies conducted by Battelle-Northwest do eliminate several potential causes of the exothermic event.

The studies also indicate the potential significance of extensive microorganism growth in the resins being a contributing factor to the exothermic event.

The results obtained by Battelle-Northwest's studies conducted in support of Arkansas Power and Light Company are summarized as follows:

Phase I studies gave no evidence of the presence of oxidants (i.e.,

o nitrates, chlorine, chlorates, etc.) in resin samples from Cask A and Cask B in sufficient quantity to cause the resin destruction observed in Cask A af ter the exothermic event.

iii

Phase I studies found no alcohols, citric acid, hydrazine, or aromatic a

compounds on resins from Cask A or in solutions obtained from Cask A af ter the exothermic event, g Additional studies identified the organics found in small quantities in Cask A and Cask E as very stable aliphatic compounds; their stability is also indicated by the fact they were still present in Cask A af ter the exothermic event.

o Phase I studies die find significantly greater quantities of Iron, Copper, Cl, and other ions present in Cask A resins in comparison to resins obtained from Cask B.

Cation and anion analyses were not conducted on other cask samples.

Solidification in cement of both cask and new resin samples supplied by 2

AP&L resulted in no significant or unexpected temperature increase.

Heats of solidification obtained from the laboratory studies were less than reported values of the heat of hydration for " normal" Portland cement.

These findings allowed AP&L to successfully solidify the resins contained in Casks A, B, C, D, and E in cement for disposal.

Verbal information was conveyed to Battelle-Northwest by AP&L personnel 9

that some previous resin solidifications resulted in significant heat generation.

This heat generation is attributable to the heat of neutralization (acid-base reaction) released by the addition of Ca(OH)2 during the solidt fication procedure H the resins are in the H+ form.

All new resins supplied by AP&L were stable in air to temperatures greatly exceeding the boiling point of water.

DSC studies indicated the least thermally stable resin was ARA-9371.

All resins will air-oxidize if the temperature is sufficiently great.

Thermodynamic calculations assuming a representative resin composition, o

removal of all water at 100*C, water and carbon as end products of oxidation and utilization of all available oxygen for combustion showed that the reaction rate would be slow. Although oxidation of Cask A resin by either oxygen (air) or by chemical oxidant (such as N0j or NO3) would have released sufficient energy to cause the observed exotherm in Cask A, iv

the initiation of air oxidation of the resins is expected to be kinetically unfavorable under normal conditions of cask dewatering.

Laboratory-scale dewatering tests gave no evidence of temperature increase. However, Battelle-Northwest believes better results would be obtained using fully-instrumented dewatering tests on actual resin disposal casks.

The presence of a variety of microorganisms in all cask samples was definitively shown. Furthermore, these microorganisms, or tester organisms believed to have similar characteristics, were shown to be capable of growth under anaerobic conditions, apparently using only residual organics and the sulfonate groups of the resin to support growth. The presence of significant quantities of these microorganisms in Cask A could have been a contributing factor to the exothermic event that occurred either through direct oxidation of the microorganism or its metabolic products.

If this oxidation of the microorganism occurred, it may have provided suf ficient heat to raise the resin bed to a temperature at which air oxidation of the resin began and continued until the event was detected.

i 1

V

f CONTENTS INTRODUCTION.........................

..................................... 1 CONCLUSIONS AND RECOMMENDATIONS............................................ 3 REVIEW 0F PHASE I RESULTS..................................................

5

SUMMARY

OF; PHASE I RESULTS.......................................1

.... 5

/

PHASE IrC0NCLUSIONS....................................................

7 P H A S E I I S TU D I E S........................................................... 9 SAMP LI NG AND DISCUSSIONS AT AP&L....................................... 9 SOLIDIFICATION OF ION EXCHANGE RESINS.................................

11 So l i di fi ca ti on Te s t Re sul ts...................................... 12 Heats of Solidification and Heat Capacities o f So l i di fi e d Re s i n Sa mp l e s.................................... 12 Di scussion of Re sin Solidi fica tion Studie s....................... 30 i

ROLE OF SUPPLIED AIR.................................................. 31 RE ACTIONS AT ELEVATED TEMPERATURE..................................... 31 J

I DENTI FI CATION OF 0 RG AN ICS............................................ 32 LABORATORY-SC ALE DEWATERING TESTS..................................... 33 PHASE III STUDIES......................................................... 35 THERMODYN AMIC EVALU ATION OF RESIN..................................... 35 Di scussion of Thermodynamic Evaluation of Resin 'Resul ts.......... 38 TH ERMAL S TA B I L I TY OF RES I N S........................................... 38 i

MICROORGANISM GROWTH IN RESINS........................................ 49 E x pe r i me n ta l P 1 a n................................................ 5 0 Experimental Ra tionale and Design................................ 51 Ma te r i a l s a n d Me tho d s............................................ 5 2 vil

I n i ti a l Re s u l t s................................................. 5 4 Cask A...................................................... 54 Cask B...................................................... 54 Cask C...................................................... 54 Cask D...................................................... 56 Cask E...................................................... 56 No n ra di oa c ti ve Re s i n s............................................ 5 6 Di scussion o f Ini tial Resul ts.................................... 56 Ad d i t i on a l Re s u l t s............................................... 5 7 Di scussi on o f Addi ti onal Re sul ts................................. 58 Conclusions......................................................59 S If tVLATED DEWATERI NG TEST............................................. 6 0 Si mul a ted Dewa teri n g Te s t Re sul ts................................ 6 0 Di scussion of Simulated Dewa tering Test Resul ts.................. 62 AP PENDIX A, DESCRIPTION OF CASK RESINS.................................... A.1 APPENDIX B, CNSI SOLIDIFICATION WORKSHEET 1...............................B.1

~

APPENDIX C, BNW LABORATORY PROCEDURES FOR SOLIDIFICATION OF ION EXCHANGE RESINS...................................C.1 APPENDIX D, DESCRIPTION OF NEW ION EXCHANGE RESINS FURNISHED BY ARKANSAS POWER AND LIGHT, ARKANSAS NUCLEAR NO. ONE.........D.1 APPENDIX E, HEAT CAPACITY AND HEATS OF SOLIDIFICATION STUDIES.................................................................E.1 APPENDIX F, SIMULATED DEWATERING TESTS....................................F.1 4

viii

FIGURES 1

Temperature Profile for Cement Solidification of Diamond Shamrock A10 10............................................ 1 5 2

Temperature Profile for Cement Solidification of D i amo n d S h a mr o ck C 2 0 -H............................................ 16 3

Temperature Profile for Cement Solidi fi cation o f RWA-78............. 17 4

Temperature Profile for Cement Solidification of' Rohm.& Haas 200C..................................................

18 5

Temperature Profile for Cement Solidi fication of ARA-9371...........19 6

Temperature Profile for Cement Solidification of Mixed 150 L/C......

20 7

Temperature Profile for Cement Solidification of Rohm-Haas 900C..... 21 8

Temperature Profile for Cement: Solidi fication of ARC-9358........... 22 9

Temperature Profile for Cement Solidification of Cask A, Core

  1. 1....

23 10 Temperature Profile for Cement Solidification of Cask A, Core #2....

24 11 Temperature Profile for Cement Solidification of Ca sk B Re pre se n ta ti ve Sampl e...................................... 2 5 12 Temperature Profile for Cement Solidification of Ca sk C Repre se n ta ti ve Sampl e...................................... 2 6 13 Temperature Profile for Cement Solidifjcation of Cask 01 (1/8) and D2 (7/8)...................................................... 27 14 Temperature Profile for Cement Solidification of Cask E, Core #1.... 28 15 DSC o f Rohm & Haas 900C wi th Air Purge.............................. 41 16 DSC of Ro hm & Haa s 200C wi th Ai r Purge.............................. 42 17 DSC o f ARC-9 358 wi th Ai r Pur ge...................................... 4 3 18 DSC o f ARA-9371 wi th Ai r P ur ge...................................... 44 19 DSC of Diamond Shamrock A101D wi th Air Purge........................ 45 20 DSC of Diamond Shamrock C20-H wi th Ai r Purge........................ 46 21 DSC of Mi xed 150 L/C wi th Ai r Purge................................. 47 1

22 DSC o f RWA-78 wi th Ai r P urge........................................ 4 8 ix

(

TABLES 1

Re si n So l i di fi ca ti on Te s t Re sul ts................................... 13 2

Re s i n P ro pe r t i e s.................................................... 3 6 3

Observa tion s of Re sin Thermal Stabili ty............................. 40 4

Re si n Decompo si tion Tempera ture..................................... 49 5

Growth Characteri sti cs of Radioactive Cask Resins................... 55 6

Summa ry o f S i mul a ted Dewa te ri ng Te s ts............................... 61 1

1 X

l

INTRODUCTION Evidence for an exothermic reaction in a bed of dewatered ion exchange resin was observed at Arkansas Nuclear No. One (ANO) on January 15, 1983. A contract was established between Arkansas Power and Light Company (AP&Li and Battelle-Pacific Northwest Laboratories (Battelle-Northwest) to chemically characterize resin samples from this cask and other related sources. This is regarded as Phase I of the study.

The final report of Phase I, dated April 22, 1983, did not reveal any unequivocal cause for the exothermic reaction.

The report did identify oxygen in air as the most likely oxidant, and stated that additional characterization of the exothermic reaction possibility would require a detailed examination of mechanisms of air oxidation of the resins.

Subsequent to the work described above, additional studies by Battelle-Northwest were authorized by Arkansas Power and Light Company.

These additional studies are described in Amendment 1 to BNW Contract No. 2311205862, and are divided into Phase II and Phase III categories.

Phase I studies were conducted on resin samples supplied by Arkansas Power and Light Company, and represented resins from Cask A, Cask B, and Unit 1, T13. Phase II and Phase III studies were conducted on resins obtained in a joint Battelle-Northwest / Arkansas Power and Light Company cask sampling effort; samples of new resins were supplied by Arkansas Power and Light Company.

Studies conducted under the Phase II and Phase III categories have largely been reported in Summary Progress Reports dated October 6,1983; January 12, 1984; and June 25, 1984.

The present final report incorporates the information previously submitted in the Phase I final report, the Summary Progress Reports and also the information obtained in other studies conducted but whose results have not previously been submitted in report form to Arkansas Power and Light Company.

The total studies conducted by Battelle-Northwest included: 1) extensive analytical analyses to determine the cations and anions present in the resin samples submitted by Arkansas Power and Light Company; 2) a determination of whether oxidants, reductants, acids or bases were present in the resin samples; 3) determination of " free" organics; 4) thermal stability of the 1

resins used by Arkansas Power and Light Company; 5) solidification of resins in cement; 6) an evaluation of microorganism growth in resins; 7) simulated dewatering tests; and 8) a thermodynamic evaluation of resin stability.

The results of the studies indicated above are reported in the following text. The studies did not result in a definitive answer as to the cause of the exothermic event that occurred during resin dewatering. However, the studies have shown that the exothermic event was not caused by " normal" chemical reaction of the resin.

2

CONCLUSIONS AND RECOMMENDATIONS Based on the results of the studies conducted in s'upport of Arkansas Power and Light Company, Battelle-Horthwest has concluded the following:

  • The exothermic event detected in Cask A was not the result of a " normal" chemical reaction, i.e., reaction caused by strong oxidants such as nitric acid, permanganate, etc.

Air oxidation is believed to have been the cause of the exothermic event u

noted in Cask A.

The presence of significant quantities of microorganisms in Cask A may o

have provided the source of easily oxidized material that initiated the exothermic event.

Some comments on air oxidation of resins may also be made, Air oxidation of the resins themselves is not expected to occur during o

cask dewatering except in very unusual circumstances. The presence of significant quantities of microorganisms may have provided the conditions necessary to initiate the exothermic event detected in Cask A.

The presence of certain metal ions, particularly Cu and Fe, are also known to promote the case of oxidation and the presence of significant quantities of these ions loaded on the resin sites may also have contributed to the initiation of resin oxidation.

Air oxidation of the resins is not expected to result in a " runaway" u

reaction under normal cask dewatering conditions. This is supported by the thermodynamic calculations used to predict the length of time required to reach the temperatures believed necessary to cause the degree of resin degradation found in Cask A after the exothermic event.

Thus, temperature monitoring of the resin bed during cask dewatering should give adequate information to determine if heat generation is occurring and the reaction could then be terminated by refilling the resin bed with water.

3

The studies conducted by Battelle-Northwest and the information supplied by AP&L indicate several " unusual" aspects related to the resin contained in Cask A.

First, the resin in Cask A had been in a resin holding tank for several years and was not easily removed from the holding tank.

Second, a strong odor, similar to that normally associated with anaerobic microbial growth (e.g., septic tank) was present during the load-out of the resin into Cask A and during the dewatering of Cask A.

Third, unequivocal evidence of the presence of several types of microbial organisms capable of sustained growth on the resin in Cask A under anaerobic conditions was obtained.

Both the greater than normal time for dewatering and the difficulty in removing the resin from the holding tank may have resulted from microbial growth in the resin. Thus, it is our conclusion that these " unusual" aspects may be

" indicators" of extensive microbial growth in the resin contained in Cask A and that the presence of these microorganisms resulted in conditions favorable to air oxidation, thereby resulting in the exothermic event detected in Cask A on January 15, 1983.

It is Battelle-Northwest's recommendation that fully instrumented temperature monitoring of cask dewatering be conducted as a means of assuring early detection of excessive heat generation in the resin bed as a result of resin oxidation during dewatering. As previously mentioned, normal cask dewatering conditions are not expected to result in " runaway" air oxidation of the resins; any excessive heat generation in the resin bed as a result of air oxidation should be easily terminated by discontinuing air flow and refilling the cask with water.

4

REVIEW 0F PHASE I RESULTS A mixed-bed organic ion exchange disposal liner designated Cask A, was dewatered for the 6th cycle on January 15, 1983, at Arkansas Power and Light Company, Arkansas Nuclear No. One, Russelville, Arkansas. Eight hours af ter the 6th cycle dewatering, steam was observed coming from the cask and liner.

The resin in the cask had been collecting on the bottom of a spent resin holding tank for approximately 4 years prior to its removal and loading of the cask. AP&L assumed the resin was ARA-9371 (anion) and ARC-9358 (cation). A second resin disposal cask, designated Cask B, also contained resin from the same spent resin holding tank, but had only been partially dewatered and had not exhibited an exotherm.

To determine the probable cause of the exothermic reaction in Cask A, AP&L requested that Battelle-Northwest analyze the resins in Casks A and B to determine the oxidizing agents present (i.e., nitrates, chlorine, chlorates),

test samples of Cask A resin taken before and af ter steam release, and determine if the samples of resin submitted would exhibit similar reactions and heat release.

Battelle-Northwest suggested a variety of analytical approaches to identify the cause of the exothermic reaction, including titration of resin samples with reducing-oxidizing agents to observe mV changes, analyzing for

" free" organics, conducting acid-base titrations of the resins, determining enthalpy differences, and complete cation and anion analyses.

Speci fic methods proposed for characterization were to be selected af ter receipt of the samples and modified if the above methods were not beneficial.

SUMMARY

OF PHASE I RESULTS Laboratory experiments and analyses were conducted to determine the probable cause of the exothermic reaction in an Arkansas Power and Light Company dewatered resin cask and liner.

No unequivocal cause for the exothermic reaction was determined af ter exhaustive chemical analyses of the Cask A resins and associated water.

Resin from Cask A taken before the exotherm, resin from Cask B which was only partially dewatered at the time of the incident, and resin from Unit I, T13, were also tested.

5

Battelle-Northwest's investigation included a thorough physical review of each sample upon receipt; photographs of each sample; chemical analyses of the resins and water samples to determine the cation and anion content; a systematic search for organics, hydrazine, and citric acid contamination of the resins and water; a study to determine the thermal stability of the resins as received and of new resin loaded with suspected chemical initiators; a review of chemical oxidants and their possible impact on initiating an exothermic reaction; and an investigation to determine if oxidants were associated with the resins at the time of the exothermic reaction.

The information obtained can be summarized as follows:

Cask A samples taken during and af ter the exothermic reaction contained o

mixtures of macroporous and gel-type resins. Cask A samples taken prior to the exotherm and samples from Unit I, T13 contained only gel-type resin.

Samples from Case: A taken during the exotherm contained Fe2 3 solids, 0

9 some of which had such a small particle size that the sample looked like a red solution.

No red solids were found in Cask A samples taken af ter the exotherm.

The solids, if present prior to dewatering, may have contributed to the unusually large number of dewatering cycles required (6 vs. 3) to complete the dewatering cycle, Cask A resin was badly damaged and had released large amounts of sulfate o

and ammonium ion into the aqueous solution. Unusually large amounts of Fe, Cu, and C1' and other ions were found in the Cask A resin as compared to resins from Cask B and Unit I, T13.

No alcohols, citric acid, hydrazine or aromatic compounds were found on o

the Cask A resin or in solution.

Differential scanning calorimetric analyses of the AP&L resins in air J

showed no exothermic reaction which alone could have caused the incident.

6

New gel-type resins loaded with suspected initiators (N02, Cu +, p,2+)

2 2

Cu + is a well-known failed to cause an exo' therm of unusual nature.

is an oxidant.(a) catalyst for redox rec <:tions particularly where 02 Anion resin (ARA-9371) was found to be stable to about 200*C, at which temperature an exothermic reaction occurred. The cation resin (ARC-9358) was stable to 310*C.

No oxidants were detected in sufficient quantity in the resins to cause the resin destruction observed in Cask A or even cause a temperature rise of greater than about 10*C, if they had reacted completely with the resin.

PHASE I CONCLUSIONS No unequivocal cause for the exothermic reaction was determined.

No components were found, other than the resin itself (in combination with oxygen from the air), which would provide enough energy to cause the observed exothermic reaction, and the resin did not react exothermically under the conditions examined in this study. Until the mechanism is determined, it is not possible to specify which component or components need to be characterized to assure safety.

(a) Basolo, F. and R. G. Pearson, 1967. Mechanisms of Inorganic Reactions 2nd ed.

p. 500. Wiley.

flew York.

7

PHASE II STUDIES Five ion exchange resin disposal casks designated Casks A, B, C, D, and E located at Arkansas Power and Light Company, Arkansas Nuclear No. One, contained resin removed during cleanout of the resin storage tank.

The objective of the Phase 11 studies was to provide data to support AP&L decisions regarding offsite shipment and disposal of the resin contained in the five casks located at ANO.

The specific work conducted under Phase II included: 1) sampling of resin casks and discussions at AN0; 2) laboratory solidification of cask resins in cement; 3) investigation of the role of supplied air; 4) studies of the reactions at elevated temperatures (thermal analysis studies); 5) identification of organics present and, 6) simulated dewatering tests.

SAMPLING AND DISCUSSIONS AT AP&L Battelle-Northwest personnel, L. G. Morgan and J. L. Ryan, traveled to Arkansas Nuclear No. One on July 31, 1983, and remained at the site through August 4,1983.

The primary purpose of the visit was to observe / participate in obtaining core samples of each of five ion exchange resin disposal casks present at ANO. These five disposal casks contained resin removed from the plant's radwaste spent resin storage tank during cleanout operations.

Removal of some of the resin required the use of very high pressure water streams.

Cask A, the cask that experienced the exothermic event detected on January 15, 1983, was the first of the five casks to be loaded with spent resin during the cleanout of the resin storage tank, and was the only cask to have completed dewa tering.

In addition, during the visit Battelle-Northwest personnel discussed the exothermic event with all personnel involved in the event and AN0's subsequent opera tion s.

They also became much more familiar with AN0's plant operations related to all ion exchange resin systems, with particular emphasis given the radwaste system.

\\

9

co Prior to the trip to the ANO site, Battelle-Northwest personnel designed and constructed a core sampling device for use in obtaining resin samples from each of the five casks described above.

The core sampler was brought to ANO by Morgan and Ryan and was used to obtain the desired resin samples. The core sampler was left at the ANO site af ter its use.

Resin samples obtained from Casks A, B, C, D, and E contain resins whose identity is unknown; i.e., the manufacturer and resin-type (anion or cation) is not known.

It was possible to determine approximate volume ratios of gel and macroreticular resins in the casks. Descriptions of the cask resins and of their visual microscopic examination are given as Appendix A of this report.

The acquisition of the samples and the information obtained during the site visit concluded this aspect of the Phase 11 studies.

The significant results of this portion of the Phase !! studies are given below.

Battelle-Northwest is satisfied the resin samples obtained from each cask o

are representative samples and adequately describe the contents of each cask.

Thus, prediction of cask behavior made as a result of studies on the resin samples obtained should be valid.

No one should be able to question any prediction on the basis of inadequate sampling of the casks.

Discussions at ANO resulted in Battelle-Northwest being fairly confident o

that the exothermic even* was not the result of what will be designated

" operator error."

Items of concern prior to the visit included the possibility of inadvertent dumping of strong oxidants such as nitric acid into the resin storage tank or the cask, the use of very hot air (such as might be obtained from portable space heaters) during dewatering of Cask A, and severe resin degradation because of high radiation levels.

Battelle-Northwest found no indication of " operator error."

In fact, plant operations essentially preclude most of the concerns regarding

" operator error" that Battelle-Northwest personnel had prior to the vi si t.

Discussions at ANO resulted in Battelle-Northwest being able to define the known history of the resins contained in each cask. Detailed information concerning the dewatering and solidt fication processes used 10 v

for resins at ANO was also obtained.

These aspects become more important when combined with results obtained under other categories, such as " Role of Supplied Air."

SOLIDIFICATION OF ION EXCHANGE RESINS Five ion exchange resin disposal casks, designated Casks A, B, C, D, and E, located at Arkansas Power and Light, Arkansas Nuclear No. One, contained resin removed during cleanout of the resin storage tank. Cask A, the cask that experienced the exothermic event detected on January 15, 1983, was the first of the five casks to be loaded with spent resin and was the only cask to have completed dewatering. Solidification and subsequent disposal of the ion exchange resins contained in the five casks was an option available to ANO if laboratory studies of the solidification process indicated no unusual or unexpected temperature behavior. Battelle-Northwest conducted instrumented solidification tests on a laboratory scale and concluded that no excessive temperature increases would be experienced in solidification of the resins contained in Casks A, B, C, D, and E using the CHEM-NUCLEAR SYSTEMS INC.

(CNSI) solidification procedure. The laboratory-scale resin solidification studies conducted by Battelle-Northwest are described in the following text.

ANO requested that Battelle-Northwest conduct the laboratory solidification tests in accordance with the procedures used by CNSI.

The CNSI solidification procedure is proprietary to CNSI and was provided to Battelle-Northwest by ANO. Written permission to provide Battelle-Northwest with the CNSI procedure was given by CNSI to ANO for the purpose of conducting the laboratory solidification tests. A copy of the CNSI solidification test No further dissemination procedure is provided as Appendix B of this report.

of the CNSI procedure shuuld be made without written permission of CNSI.

Battelle-Northwest modified and expanded the CNSI procedure for the purposes of the instrumented laboratory studies. Modification consisted primarily of not placing the cement-resin mixture in an oven but rather in an instrumented dewar for temperature monitoring.

A complete description of the laboratory resin solidification procedures used by Battelle-Northwest is given in this report as Appendix C.

11

Laboratory-scale solidification tests were completed for the following f on exchange resins obtained from AP&L, ANO site: A1010, C20-H, RWA-78, Rohm and Haas 200C, ARA-9371, Mixed 150 L/C, Rohm and Haas 900C, ARC-9358, and samples representing the contents of Casks A, B, C, D, and E.

The numerically designated resins were resins supplied to Battelle-Northwest by AP&L and whose designations correspond to those on the sample containers as received by Battelle-Northwest.

It is Battelle-Northwest's understanding that these resins are "as supplied" to AP&L by the various manufacturers. No treatment of the resins other than that described in the laboratory solidification procedures was done by Battelle-Northwest.

Brief descriptions of these resins are given in this report as Appendix D.

Solidification of both new and cask resins was conducted in accordance with the procedures given in Appendix C.

Additions of Ca(OH)2 to some of the new resin slurries generated heat. The increase in temperature indicated that the new resin was in the hydrogen-form and a simpic acid-base neutralization reaction occurred, releasing the heat of neutralization. No increase in temperature was found when Ca(OH)2 was added to the actual cask resins, thereby indicating. hat no significant amount of hydrogen-form resin remained. Any resin in the casks that was originally in the hydrogen-form had already been converted to some other cation form before being loaded into the Consei uently, new resin samples that showed an increase in temperature cask.

l when Ca(OH)2 was added were allowed to return to ambient temperature before addition of cement and temperature monitoring of the solidification process.

Solidification Test Results Summary data of the solidification tests are given in Table 1.

Temperature vs. time plots are also given for each test in Figures 1-14.

Heats of Solidification and Heat Capacities of Solidified Resin Samples The experimental heats of solidt fication for the resins were determined, as were the experimental heat capacities of the solidified resin samples.

The results of these studies indicated that the heats of solidification were less 4

than values reported for " normal" cement solidification.

Experimental details are given in Appendix E.

12

TABLE 1.

Resin Solidification Test Results Test flo.1 Test flo. 2 Test flo. 3 Test No. 4 Test No. 5 Test tio. 6 Test No. 7 i

Diamond Diamond Shamrock Shamrock Rohm & Haas Rohm & Haas Type of Resin A101D C20-H RWA-78 200C ARA-9371 Mixed 150L/C 900C as recvd as recvd as recvd as recvd as recvd as recvd as recvd Height of 100 ml of settled and then "dewatered" resin 72.9 g 79.7 g 72.7 g 90.0 g 73.8 g 77.0 g 69.7 g Height of water in solidification beaker 35.9 g 33.3 g 33.9 g 34.0 g 34.7 g 32.4 g 39.5 g Initial pH of resin slurry 5.5 5.0 5.5 5.5 6.0 5.5 5.5 Final pH of resin slurry 13.0 12.5 13.0 13.0 12.5 12.5 12.5 Weight of Ca(OH)2 added 5.0 9.0 5.0 5.0 5.0 5.0 5.0 1

j Temperature af ter Ca(OH)2 addition Height of cement added 107.7 119.7 87.3 87.1 115.9 112.7 87.4 Tenperature af ter cement addition 23.2*C 22.8*C**

22.6*C 22.8*C 24.2*C 23.4*C Maximum temperature observed 29.0 *C 27.0*C 23.5*C 25.8*C 26.6*C 29.6*C 25.5*C

  • Not Observed
    • Af ter return to ambient temperature prior to cement addition

TABLE 1.

Resin Solidification Test Results - Con't Test No. 8 Test No. 9 Test No.10 Test No.11 Test No.12 Test No.13' Test No.14 Cask A/Corel Cask D Smple 1,1/3 Cask A/ Core 2 Cask B Cask C Btm 6* 1/8; Cask E/Corel Type of Resin ARC-9358 Suple 2,1/3 Smple 1, 1/8 Represent. Represent. Represent.

Seple 1, 1/4 as recvd Smple 3,1/3 Smple 2, 7/8 Sample Sample Seple, 7/8 Seple 2, 3/4 l

Weight of 100 ml of settled and then "dewatered" resin 82.4 g 78.0 g 79.4 g 79.2 g 80.9 g 79.9 g 85.8 g Weight of water in solidification beaker 31.6 g 40.4 g 31.4 g 32.7 g 32.9 g 34.2 g 30.0 g Initial pH of resin slurry 5.5 5.5 5.5 5.5 5.5 5.5 5.5 Final #1 of is resin slurry 12.5 12.5 12.5 12.5 13.0 13.0 12.5 Weight of Ca(OH)2 added 11.0 5.0 5.0 5.0 5.0 5.0 5.0 Temperature af ter 21.0*C 21.0

  • C 21.0*C 21.0*C 21.0*C 21.0*C Ca(OH)2 addition Weight of cement added 115.6 88.5 95.9 97.6 100.5 95.6 84.9 Temperature af ter cement addition 23.6*C 21.8*C 21.6*C 21.0*C 21.6*C 21.8*C 23.2*C Maximum temperature observed 24.9'C 24.0*C 23.8*C 22.4*C 22.4*C 22.4*C 23.8*C
  • Not Observed

ll 5

2 D

1 0

1 A

0 k

I 2

corm a

h S

dn oma i

D fo 5

I 1

no s

i r

t h

ac

,e i

m f

i i

T d

i d

l es o

p S

a l

t E

ne l

0 m

1 e

C r

o f

e l

i f

or P

eru l

5 tarep me T

1 E

R U

G I

f-F

~

O 0

8 6

4 2

0 3

2 2

2 2

2

) 65g EEy L

~ u s

ll 1l ll'

\\l i

i

l1 5

2 H

0 2

C 0

2 kco rma h

S dn oma i

D f

5 o

1 n

s o

r i

h ta

,e c

m i

a f

T i

d d

i e

l sp o

la S

E tn 0

e 1

me C

ro f

e l

i f

or P

er I

5 u

tare p

/

T me 2

E R

UG I

~

O F

0 8

6 4

2 0

3 2

2 2

2 2

P i 5 i I> k [*

i i

.i l 1l

5 2

/

/

0 2

N 8

7 AW R

fo 5

I 1

no s

i r

t h

a

/

c e

i m

f i

i T

d d

i e

l s

o p

S a

l t

E ne 0

m

/

l 1

e C

r o

f e

l i

f or P

eru 5

t I

are p

me T

A 3

E RU G

I 1

F O

0 8

6 4

2 0

3 2

2 2

2 2

Pa55E Ey E

5 2

i C

x l

2 2

0 0

0 s

aa H

ho R

i fo 5

n I

1 o

i s

t r

h ac i

e f

m i

i i

T d

i d

l e

o s

S p

l t

a E

ne 0

me l

1 C

r i

o f

e e

l i

f i

or P

e eru t

5 I

are i

p me i

T i

4 E

R b-O

[

i UG I

0 8

6 4

2 0

3 2

2 2

2 2

iE$

_m L

l

Il1 5

2 O

0 A

I 3

2 1

7 9

O ARA I

fo n

I o

i 5

ta 1

c s

i r

f h

i I

m e.

d i

l e

o T

S I

d t

es n

p e

I a

m l

e E

C 0

r 1

o f

f e

l i

f for f

P e

f ru ta 5

rep m

f e

T f

s f

cau t

c i

F O

0 8

6 4

3 2

2 2

U :fi?s l

l ll, lll

llIIl 5

2 9

C

/

l 0

L 2

0 5

1 de x

i M

fo no i

5 t

l 1

a s

c r

i h

f

'1 e,

d m

i e

l T

o S

d e

t s

p n

la em E

e 0

C l

1 ro f

e l

t i

for t

P e

t ru t

3 arep me T

6 ERU G

I

~

F 0

0 8

6 4

2 3

2 2

2 2

n uo &5 3ocEo&

mo l

li l1

!i' s

i l

i i:

l

.1l1lI1ll; 5

2 T

/

0 C

I 2

009 saa H

/

m ho R

/

fo 5

I 1

no s

i r

t h

a e,

c f

m f

i i

i T

d i

d l

es o

p S

la t

E ne V

0 m

I 1

e C

r o

f e

l

/

i f

or P

eru t

are p

me T

7 E

R U

G s

I F

0 8

6 4

2 0

3 2

2 2

2 2

'b l!5y e

5 2

0 2

8 5

3 9

CRA fo 5

I 1

no s

i r

h ta c

e i

im f

i T

d d

i e

l s

o p

S la E

tne 0

m I

1 e

C ro f

e l

i f

or P

eru 5

t are p

me T

8 E

R U

G I

F O

0 8

6 4

2 0

3 2

2 2

2 2

)! a 3 l oH Ti N

I

\\ll ll!

lll 03 A

I s

5 I

2 1

er o

C A

ks 0

a I

2 C

fo n

o i

s t

r a

h c

i e

f im i

d 5 T l

i 1

l de o

s S

p la tn E

eme C

r o

f 0

l 1

e l

i for P

e ru t

ar 5

e l

p me T

9 ER U

G I

k O

F 0

8 6

4 2

0 3

2 2

2 2

2 i55 C$

O

ll l

03 I

5 2

I 2

ero C

A k

sa C

0 I

2 fo no i

ta s

c r

h i

f e,

i m

d s

I 5 T i

i lo 1

d S

e s

t p

n a

l e

E me C

ro f

0 e

I l

1 i

for P

e ru ta rep 5

m I

N_

Te 0

1 E

R U

G I

F O

0 8

6 4

2 0

3 2

2 2

2 2

)! s 5 E E a E y N*

i i

30 1

28 1

I P 26 s

3 E

bc E

l 3

g 24 i

i 22

~

~

~

\\

4 1

I I

l I

20 i

0 5

10 15 20 25 30 4

f Etapsed Time, hrs 1

FIGURE 11. Temperature Profile for Cement Solidification of Cask B Representative Sample 1

n,

.gs

~

A ao 28 26 d

3g s

N CL Ey 24 22 g

~ _.

l 20 i

i l

i l

I l

I i

i i

i O

5 10 15 20 25 30 Elapsed Time, hrs x

~

FIGURE 12. Temperature Profile for Cement Solidification of Cask C Representative Sample

~

=

.s c

s 3

llll 1l i

ll 5

2

)

8

/

7

(

2

~

D d

n 0

a I

2

)

8

/

1

(

1 D

k sa C

fo I

5 n

1 o

i s

t rh a

c i

e f

m i

i d

T i

d l

e o

s S

p i

la t

E ne I

0 m

e 1

C ro f

e i

l i

f i

or P

e ru t

5 a

I rep m

e T

3 1

E R

U G

I F

0 0

8 6

4 2

0 3

2 2

2 2

2 P c5gEaEy i

~w

5 2

/

M.,

0 l

2 1

f re o

C E

ksa C

fo l

5 n

1 o

s i

r t

h a

e, c

m f

i i

i T

d i

d l

es o

p S

la t

E ne l

0 m

e 1

C r

o f

e l

i f

or P

eru t

I 5

are p

m e

T 4

1 E

R UG I

F O

o 0

8 6

4 2

0 3

2 2

2 2

2 Y i36OaE*H rm o

,4 i

The heat capacity of cement solidified resin samples was measured using Differential Scanning Calorimetry (DSC) and found to be within the range reported for normal cement samples (a)

Samples from the solidification study using Diamond. Shamrock C20-H and Rohm & Haas 200C resins had heat capacities of 0.222 cal /g/deg and 0,312 cal /g/deg, respectively.

The heats of solidification were calculated using

' aH (solidi fication) = AH (system) + C ' AT P

where JaH (system) = amount of heat lost to the system and C AT is the enthalpy change of the cement-solidified resin p

The experimentally determined heat capacity values reported above (from DSC studies) and the heat loss to the system used for solidification of the cask resins result in a AH (solidification) range of 21.8 cal /g to 22.0 cal /g, for solidification Test No. 9 (Cask A, Core 1).

Similar values are obtained for all the other tests. Lea (a) reports heats of hydration for " normal" cement of 61 cal /g at 3 days of curing, 79 cal /g at 7 days of curing, and 96 cal /g at 28 days curing.

" Normal" cement was not defined by Lea (a),

Variations of water / cement ratios (0.4 to 0.6) can change the heat values by 10-15%, and the type of cement can change the heat values by 15-30%. The experimental values are 21-57% lower than reported values (a) based on the heat of hydration for 3 days of curing and therefore indicate no reason for concern regarding the heat of solidification of both new resin-and cask-cement r

(a) Lea, F.M. 1971.

The Chemistry of Cement and Concrete, 3rd ed. Chem.

Pub. Co., Inc., New York.

29

--,w w---v-v.-

,w

-y,

  1. w--y,--W<w www

-er ww e---Ne---Fw-a M

  • --T-~-ew~wwe 4*

+--n*-*++(--+-r

composi tions. Any major exothermic enthalpy change other than the heat of hydration would have been detected.

Discussion of Resin Solidification Studies The instrumented solidification studies indicated no significant differences in behavior between new and cask resins supplied by AP&L.

Slight variations in the maximum temperatures obtained are within the deviations expected for this type of study.

No hazardous or unexpected exothermic reactions were noted in any of the solidification tests.

The maximum temperatures obtained for the cask samples were: Cask A, Test #9, 24.0*C af ter 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />; Cask A, Test #10, 23.8*C af ter 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />; Cask B Test #11, 22.4*C af ter 2.5 hours5.787037e-5 days <br />0.00139 hours <br />8.267196e-6 weeks <br />1.9025e-6 months <br />; Cask C, Test #12, 22.4*C af ter 29 hours3.356481e-4 days <br />0.00806 hours <br />4.794974e-5 weeks <br />1.10345e-5 months <br />; Cask D, Test #13, 22.4*C af ter 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br />; and Cask E, Test #14, 23.8'C af ter 21 hours2.430556e-4 days <br />0.00583 hours <br />3.472222e-5 weeks <br />7.9905e-6 months <br />. Ambient air temperature was approximately 21*C.

These temperatures are more than 100*C less than those noted to cause visual changes in appearance of the new resins supplied by AP&L and more than 200*C less than the temperature required to cause visible resin degradation.

The data reported above for the actual cask resins resulted in an experimental heat of solidification for Cask A, Test #9, of ~22 cal /g. This value is less than that found in the literature for the heat of hydration of

" normal" cement.

The calorimetric cells have a fairly high rate of heat loss and this contributes to the error of long-term experiments.

However, the significant fact to note is that there was essentially no difference in the solidification behavior of new and cask resins.

Based on the laboratory resin solidification tests, Battelle-Northwest predicted no excessive temperature increases would be experienced in solidification of the resins contained in Casks A, B, C, D, and E using the CNSI procedure. No significant temperature differences between lab-scale and full-scale tests are expected.

In addition, solidification excludes oxygen from the resin. As stated in the Phase I report, we believe oxygen was the oxidant necessary for the exotherm noted in Cask A in January 1983.

30

ROLE OF SUPPLIED AIR Battelle-Northwest postulated at the conclusion of Phase I that oxygen (in the air) was the oxidant necessary for the exothermic event in Cask A.

Phase 11 studies in this category further addressed this question using both thermodynamic calculations based on assumed reactions and correlation of resin degradation with temperature.

The significant results obtained are:

Phase I studies gave no evidence of strong oxidants being present in o

either Cask A or Cask B in sufficient quantity to be a concern; i.e.,

no significant quantity of nitrate, nitrite, chromate, permanganate, etc., was found.

This finding strongly indicated that the oxidant was not present as an ion loaded on the ion exchange resin. Furthermore, if nitric acid, nitrate, or nitrite had been the oxidant we would expect oxides of nitrogen to have been present in the gases evolving from Cask A during the exotherm.

No oxides of nitrogen were noted by ANO personnel at the time the exotherm was detected, o

Resin oxidation with air can occur.

Theoretically a large enough mass of resin with air pulled through at the proper rate will oxidize, retain the heat of combustion, and the temperature of the resin will increase. However, pulling air at the operating rate and at ambient temperature through the resin in the cask is not expected to result in any significant oxidation of the resin and therefore no temperature increase would be expected.

This is supported by general knowledge of ion-exchange resin properties and by the successful use of the dewatering procedure by many different utilities, including ANO operations prior to the exothermic event.

Additional information regarding the role of supplied air, i.e.,

thermodynamic calculations and correlation of resin degradation with temperature, are reported in the Phase III portion of the present report.

REACTIONS AT ELEVATED TEMPERATURE Thermal analysis studies of resin behavior were conducted.

These studies 1

and their results are reported in the Phase III portion of the present report.

31

IDENTIFICATION OF ORGANICS Organic material was found as a coating on resin beads in samples from Cask A.

Samples of Cask A resin were washed with xylene, carbon tetrachloride, and ethanol.

Each solvent removed some of the organic material, but xylene removed the greatest amount and carbon tetrachloride the least.

Oily material was also found on top of the aqueous phase in Cask E and samples of this material were also examined. The material was an emulsion of organic and aqueous phases and was quite resistant to phase separation.

The phases were separated by prolonged centrifugation.

The organic material from Cask A and Cask E was examined using infrared spectroscopy and gas chromatography. The organic material found in these casks is very similar. The material has a high boiling point and consists mainly of aliphatic hydrocarbons.

Small amounts of organic acids and esters are probably present, and there is evidence of traces of aromatic materials.

Battelle-Northwest concluded that there were no significant differences in the organic material found in-Cask A and Cask E.

Furthermore, this material is not expected to be easily oxidized because of its high molecular weight and aliphatic nature. Support for stability of this organic material is given by the fact it is still present in Cask A af ter the exothermic event. Our most likely guess is the material is a lubricating oil that entered the radwaste system by some means.

The presence of this organic material may also have contributed to the difficulty experienced in emptying the resin holding tank.

The organic material could act as a binder to form an aggregated resin mass that would not be easily removed using the standard technique to transfer resin from the holding tank to a disposal cask.

If this resin mass existed long enough in the holding tank, then microorganism growth that fed on the foreign organic material in essentially anaerobic conditions is a possibility. The microorganisms themselves, or their metabolic products, may have provided the easily oxidized material that initiated the exothermic event in Cask A during dewatering (the dewatering 32

1 procedure providing oxygen from the air as the necessary oxidant). The possibility of extensive microorganism growth was examined; the results of these studies are reported in Phase III of the present report.

LABORATORY-SCALE DEWATERING TESTS Laboratory-scale dewatering tests were conducted on new resins, actual cask resins, and resins containing significant microorganism growth. No exothermic reactions were detected.

Because these dewatering tests were conducted after the completion of the microorganism studies, the complete details and results of these tests are reported in Phase III of the present report.

33

l PHASE III STUDIES Phase III studies were directed toward understanding the mechanism or mechanisms whereby the exotherm observed in Cask A became possible.

Several studies originally proposed under Phase II were conducted under Phase III because they aided in determining what conditions do or do not produce an exotherm. The specific work conducted under Phase III included: 1) a thermodynamic evaluation of resin stability, 2) elevated temperature studies,

3) microorganism growth in resins, and 4) simulated dewatering tests.

THERMODYNAMIC EVALUATION OF RESIN The following is a theoretical study concerning the energies involved in obtaining resin bed temperatures high enough to cause exothermic reactions with only the resin itself and oxygen as reacting components.

The calculations are in three parts: 1) heat required to pyrolyze the resin,

2) heat released by resin oxidation, and 3) time for resin bed to reach pyrolyzing temperature.

~

The four resins considered are ARC-9358, ARA-9371, IRA-200C, and IRA-900C. As shown in Table 2, these represent two sulfonic acid exchangers, a quarternary ammonium exchanger, and a polyamine exchanger.

Two are gel-type, and two are macroreticular.

Three are based on polystyrene, and one on an epoxy-polyamine.

These are representative of most resin types.

Resin ARA-9371 pyrolyzes at the lowest temperature, ~200*C.

ARC-9358 was found to pyrolyze at 335'C-350*C.

However, as shown below, calculation of the total heat evolved is not very sensitive to the final temperature reached within this range.

Table 2 lists properties of the resins used for calculations.

To calculate the heat required for pyrolyzation, the following assumptions were made:

1)

Resin bed consists of 1/4 by volume of each resin listed above:

388 g H 0/L + 366 g exchanger /L.

2 2)

Ambient temperature, 20*C.

35

3)

Heat capacity of the resin is within acceptable limits of polyethylene, 0.3 cal /deg/g.

4) All water evaporates at 100*C with no binding energy to the resin.
5) No heat loss occurs to the air being pulled through the bed.

6)

The final resin bed temperature was 300*C uniformly throughout the bed.

TABLE 2.

Resin Properties (a)

Percg Bulk Description Resin HO Density, kg/L 2

Epoxy polyamine ARA-9371 53-57 0.730 gel (Used data for A-30)

Styrene sulfonate ARC-9358 43-46 0.817 gel (Used data for C-20)

Styrene sulfonate IRA-200C 48 0.80 macroreticular Styrene ammonium IRA-900C 60 0.67 macroreticular (a)

Yalues reported by manufacturers for resins in Ha+ and Cl forms.

(b)

Experir. ntal determination of water content on an equivolume mixture of the four resins listed after conversion to H+ and OH-form gave a water content of 50% H O vs the 51.5% H O predicted using the table values.

2 2

This difference in water content is about what is expected because of the different form and does not greatly affect the thermodynamic calculations.

The heat required to raise the resin bed to 300*C is:

0 (100 -200)[CH 0(wt. H 0/O + Cresin (wt. resin /L)]

2 2

H0 0

0 vap(wt.H 0/L) + (300 -100 )

+ aH Cresin(wt. resin /L) 2

= 800 [(1 cal /g/deg) (388 g/L) + (0.3 cal /g/deg) 0 (366 g/L)] + (540 cal /g/deg) (388 g/L) + (200 )

(0.3 cal /g/deg) (366 g/L) = 271 kcal/L.

36

It should be noted that water evaporating below 100*C, or a lower final temperature, would lower the heat requirement. However, the largest term is HO the AH 2 If not all the water evaporates from the total resin bed, or if vap.

the water content is lower than estimated, or if only the lower part of the resin bed lost all of its water and reached 300*C, a much greater difference in the heat requirement would be observed. Comparison of manufacture's values with experimental determinations gives confidence to the water content values used. However, a real possibility exists that not all the water was vaporized.

To calculate the heat released during oxidation of the resins, the following assumptions were made:

1) Combustion goes to completion
2) Since the heat of combustion will vary between resin types and the exact composition of the resin in Cask A was unknown, a representative value was selected. Water and carbon would be the products under a oxygen-deficient, low-temperature combustion.

The representative compound chosen for these calculations was ethylbenzene:

C "10 +

02 + 8C + 5 H 0(g) 8 2

AH = -114.4 m

02

3) Cask A was full of resin,103 f t3 = 2916 L 4

4)

Sandpiper pump pumped air at 1.5 gal /sec = 2.04 x 10 L/h At 20*C,114.7 L of air contains one mole 0.

The oxygen flow rate in 2

Cask A would be:

4 (2.04 x 10 L/h) (114.7 L/ mole 0 )

= 178 moles 0 /h.

2 2

This is equivalent to 0.0612 moles 0 /L/h or (0.0612 mole 0 /L/h) (114.4 2

2 kcal/ mole 0 ) = 7.00 kcal/L/h.

2 37

To release 271 kcal/L would require (271 kcal/L) (7.00 kcal/L/h)-1 = 38.8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br />.

Discussion of Thermodynamic Evaluation of Resin Results The thermodynamic evaluation of resin oxidation given above is believed to be a reasonable approximation of the results expected from air oxidation of the resin.

Uncertainties exist in this evaluation, and these have been stated in the discussion.

Specifically, the resin composition is not known, and we assumed all water was removed at 100*C, that water and carbon were the products of the oxidation, and that all available oxygen was utilized in combu stion.

Similar calculations were performed using benzene (C H ), ethane (C H )*

66 26 and trimethylamine hydrochloride ((CH )3NHCl) as representative compounds of 3

combustion.

Little difference in the results exists when comparison of the heats of combustion are made on a per mole of 0 basis. Oxidation of C H 2

26 with nitrite or nitrate ion also yields similar thermodynamic results.

Oxidation of the Cask A resin by either oxygen (air) or by chemical oxidant (such as N0j or NO ) would have released sufficient energy to cause 3

the observed exotherm in Cask A.

However, the process must be initiated and the initiation of air oxidation of the resins is expected to be kinetically unfavorable under the normal conditions of cask dewatering.

The time required to raise the resin bed temperature from ambient to 300*C by oxidation of the resin with air pumped through under the operating conditions was calculated to be ~39 hours. While this time length is not unlikely for the dewatering process, it does indicate a slow reaction rate.

THERMAL STABILITY OF RESINS The objective of these studies was to observe the temperatures necessary to obtain resin characteristics similar to those observed in the cask resin samples (Appendix A).

Two tests were run on new lon exchange resins supplied by AP&L:

1) a qualitative description of resin materials after heating the resins in air for prolonged time periods (16-20 h), and 2) determination of resin decomposition temperature by differential scanning calorimetry (OSC).

j 38

=.

In the former test, resin samples were placed in open glass vials inside an oven. All resins began to show visible changes in appearance (darkening) by at least 150*C. However, a minimum temperature of ~250*C was necessary to produce obvious resin degradation (loss of bead structures, pyrolysis, etc) in any of the samples. The ARA-9371 resin was the least stable and at 350*C, was a bubbling, pyrolyzing mass that finally produced a solid char. Some bead structure was still apparent, however, in the product of ARA-9371 degradation.

Table 3 presents observations noted during these studies.

The DSC studies indicated that all the resins were stable to 200*C in air with the possible exception of ARA-9371. Af ter its initial water loss, this resin

( ARA-9371) has a slow constant exothermic drif t which may or may not be a return to baseline by additional water loss.

Figures 15-22 present the actual DSC decomposition curves for the resins. Decomposition temperatures for the new resins, as determined by the DSC studies, are summarized in Table 4.

Based on the appearance of new resin as a function of heating temperature and an examination of the variety of resin samples obtained from Cask A, it was concluded that essentially all the resin present in Cask A probably reached a minimum temperature of 300*C during the exothermic event; zones within the cask may have approached a temperature of 400*C.

39

IOI T AIL E 3.

Oburvations of Resin Th%rmal Stability Diamond Diamond Tenperat ure Shamrock Shamrode Rohm & Haas Rohm & Haas Exposure Time A101D C20-H RWA-78 200C ARA-9371 Hixed 150 t/C 900C ARC-9358 As received Li@t tan Dark brown Hedium brown Dark beige Mediun tan Mediun brown Hedium beige Dark tan 149'C Very sl.

Black.

No change Very sl.

Dark tan Hixed, medium Dark beige Black, hard 16 hr.

darker Grey film li@ter tan & dark lumps that were on glass not easily brok en.

Sli@t grey film on glass.

19 7*C Darkened to Same as Dark tan Same as Very dark Same as Darker beige Same as 149'C 16 hr.

med. brown 149'C 149'C

brown, 149'C-beas Lumps seem almost black darker harder.

o 254*C Black beads Black-loose Black-loose Black-loose Black-heavy Black-loose Black-loose Large black clunps.

20 hr.

in small bea&.

bea&.

bea&.

51.

clump. Brown beads.

Sl.

bea&.

Sli@t clunps.

grey film film on grey film grey film on on glass, glass.

on glass.

glass.

306*C Black beads. Black beads. Black beads. Black beads. Black heavy Black beads.

Black beads.

Large black clunp-20 hr.

Sli@t grey Small clumps. Sli@t grey Sli@t grey clump.

Sli@t grey S11@t grey some loose beads.

film on Sli@t grey film on film on Massive film on film on Sli@t grey film glass.

film on

glass, glass.

degradation, glass.

glass, on glass, glass.

Heavy brown film on glass.

(a)

In the sample descriptions, black color was observed with the naked eye with the sample exposed to air.

It does not necessarily imply that the samples were carbnnized.

.. =.

4 2s.m ROHM & HAAS 900C CATION RESIN WT:

7.36 mg SCAN RATE.

10.00 d.9 min

/

A 2

na o

LLI

$ Is.m i

i 4

i i

i.

s.m lis.m Is.m 21s.m 2s.m 31s.m ass.m 41s.m 4 tis.m 51s.m ses.m s.m RO DE22r rne, RNas, m TEMPERATURE (C)

DSC DATE:

04/01/09 TIME:

13:59 lPERKIN ELMERl Thermal Analysasl i

FIGURE 15.

DSC of Rohm & Haas 900C with Air Purge

SL N ROHM & HAAS 200C RESIN WT 18.12 mg SCAN R TE:

10.00 deg/ min Ci o

tal f 25.N L1 E

ro E. 5 118. m liiE N 218. 5

25. E 318.W 35.5 41's. E 4GL M 518.N SES.E RJS F/LE: RH2OOa4 TEMPERATURE (C)

DSC DATE:

83/12/16 TIME.

15 15 FIGURE 16.

DSC of Rohm & Haas 200C with Air Purge

l 11 J

M.

l s

.8 is 6

y 5

lanA ta C

n N.

S en

.8 D

m 15 l

R N

N.

E

.5 M

64 R

N N.

l

~.81 S

4 B

B.

)

~.5 C

63

(

E R

M.

U 1

.8 K

e 13 g

R r

E u

P P

M 5

E r

i O

8 T

6 A

I 2

T h

A t

R iw N

5 8

O n

.8 5

TI i

21 3

m 6

9 A

/

C g

5 C

e

9 R

8 d

A 0 A

N.

D 5

0 3

5 B.

f 0

9 S

1 o

E 0

3 C

9 C

M g 1 R m A

S I

T A

D n

3 B

B.

L

E
8 I

9 T,

F 1

1 0

7 P

1 1

/

i 1

E te 0

R N.

r/

U

T C m3 G

W S

2 8

I F

hc N.

N.

N.

sE T

5 B

9 8

e 1

s 3

A D E6 i

A fp

.I i

(!!

aw f

1i

ji4

' i f

1 i.

!i i-l

,1

M. E ARA-9371 ANION RESIN WT 8.06 mg SCAT 1 RATE:

19.90 deg/ min r

n S

l 2

,I w

e

\\

I l

l o

UI

\\

R 15.5 2l x

\\k GL E

!!8.5 Ifiks 21kB 21 5. 5 31kW 35.5 415. 5 4 fig.E 515. 5 55.5 RJ SCVEE7E r/IEs AS371. OA TEMPERATURE (C)

DSC DATE:

84/01/09 TINE:

15.23 lPERKIN ELMERl Thermal Analysis l FIGURE 18.

DSC of ARA-9371 with Air Purge

5 l

5 e

s s

2 la y

nA la C

m 5

S re

~E D

h 1

T 5

]

R E

M i

L E.

E 5

IN 4

MRE P

5 l

8 14 egru P

5

)

r 5

C i

3

(

A E

h R

t i

5 U

w T

8 A

D 13 R

1 E

0 1

P A

M E.

E k

g T

co t2 rma h

S D

5 n

8 d

1 i

1 n

0 m

o 2

1

/

6 m

A g

5 a

e i

d 4

D K

5 1

C 8

f O

0 5

o 1

s R

0 E

M g1 M

C A o I

S A

T D

H O

9 5

0 S 9

.E 8

1 D 3 T e

9 1

1 J

1 A

l 4 1

t R

0 A

1

/

E M

i E,

2 R

d A

A 1

z U

T C 5

n3

/

I G

W S D

5 8

I F

5 5

E 5

1 S

T 5

2 O A R D eew Ot(1 0E li 4no

15.N i

DIA t'D SHAMROCK C20-H WT 4.54 mg AN T E.

10.00 deg/msn i

l b

i o

(Al m

7. s.

.J<

L)

A E

cn i

i i

f i

68. N 118.N 16il.N 21's. N 26il. N 318. N 36il. N 41's. N 46ILN 513.N 56IL M RO SCNEEZE F/4EsCEJN.BA TEMPERATURE (C)

DSC lPERKIN ELMERl Thermal Analysis l DATE:

04/31/19 TIMES 15 50 r

FIGURE 20.

DSC of Diamond Shamrock C20-H with Air Purge j

n.u s

C n.

S h

U t

5 m.

rc 4

m.

h t

4 i

m.

)

r i

C sa

(

E e

R gr m.

U u

T P

h A

t3 R

r i

E A

P M

h m.

E t

i 2

l 3

w C

/

L

~

m.

0 n

h 5

i.

1 1

2

/

4 d

g 3

e x

a 3

i m.

M 1

ac s

f i

a E

o gI M

1 C

C

\\

1 1

S 3

D

/ 3 m.

c.

L 5

.r 0

h 2

7 T

'. e 6'.I 5

1 A

5 C

1 1

n 1

2

/

d e

n G.

2 E

1 R

x 1

i T c n.

7 '.

U s

Mh 4

3 G

s 8

I

/

F m.

n.

i t

S l

9 r

2

/. A

,. J 0 f :.

eUP

.+S 0

38.N RWA-78h WT 1 5. 2 mg SCAN.R[TE:

10.00 deg/msn 5

j t1 t:,

l

@ 15.N d

V 4

~

i l

l 1

l l

1 8.8B 113. 5 168.W 218. 5 26II.M 318.W 360.M 413.m 483.N 51E.5 Stig,m

~

68. M Fil6 ##d78 BA TEMPERATURE (C)

DSC lPERMIN ELMERjihermal Analyses l DATE:

03/12/14 TIME:

16: L'8 i

1 FIGURE 22.

DSC of RWA-78 with Air Purge l

l TABLE 4.

Resin Decomposition Temperature Decomposition Temperature, *C Resin (OSC Results)

Rohm & Haas 900C 210 Rohm & Haas 200C 290 ARC-9358 300 ARA-9371 140-200 Diamond Shamrock A101D 240 Diamond Shamrock C20-H 250 Mixed 150 L/C

>200 RWA-78 340 MICROORGANISM GROWTH IN RESINS Five ion exchange resin disposal casks, designated Casks A, B, C, D, and E, located at Arkansas Power and Light, Arkansas Nuclear Ho. One, contained resin removed during cleanout of the resin storage tank. Cask A, the cask that experienced the exothermic event detected on January 15, 1983, was the

+

first of the five casks to be loaded with spent resin and was the only cask to I

have completed dewatering.

The results of Phase I indicated the absence of any significant quantity of strong oxidants in either Cask A or Cask B.

Thus, Battelle-Northwest concluded that oxygen in air was the likely oxidant.

The question then was:

How did the resin degradation (oxidation) initiate?

Battelle-Northwest proposes that the presence of significant quantities of microorganisms could have provided the ingredients necessary to initiate the exothermic event detected in Cask A.

The presence of significant quantities of microorganisms could have contributed to the initiation of the exothermic event by the following mechanisms.

First, microorganisms generate heat as a byproduct of their metabolism.

Population growth of microorganisms can also be extremely rapid if favorable

.. - e 49

growth conditions exist.

If enough heat is generated and is retained by the bulk material in which the microorganism is found, the temperature of the bulk material will increase. These effects are commonly observed in compost piles.

If the temperature increase is sufficient, auto-oxidation of materials can occur, finally resulting in combustion (rapid oxidation) of the bulk material - this is the cause of the so-called " green-hay" fires.

Second, both aerobic (oxygen using) and anaerobic (non-oxygen using) microorganisms exist. Most anaerobic microorganisms can utilize sulfur in their metabolism; sulfur is present in the structure of most of the resins used at ANO.

The presence of either live or killed microorganisms is a source of finely divided organic material.

The high surface area to mass ratio of the microorganisms favors their oxidation at a lower temperature than either direct resin oxidation, or oxidation of stable organics. As oxidation occurs, heat is generated and can be retained by the bulk material until the temperature of the bulk material increases to the value required for its combustion (rapid oxidation).

Third, the metabolic products of the microorganisms may be more easily oxidized than either the organic resins or other organics originally present.

}

Thus, the presence of significant quantities of microorganisms in the casks could possibly result in an exothermic event being initiated by one or I

more of the mechanisms described above.

The purpose of the microorganism studies described in this report was to determine if the mechanisms described above could have existed in Casks A, B, C, D, and E.

Experimental Plan Battelle-Northwest states at the outset that it is not a straightforward microbiological problem to determine the possibility that bacterial metabolism initiated the exothermic reaction that occurred during dewatering of Cask A.

The studies are a basic research problem, not an engineering problem.

Therefore, a predetermined set of procedures do not exist that can be applied to answer the question: Did the exothermic event in Cask A have a biological origin? Moreover, unless the conditions in the cask just preceding the 50

exothermic event can be reconstructed, it cannot be concluded that negative results imply lack of a biological component in the exothermic reaction.

Reconstruction of conditions existing in Cask A prior to dewatering is very difficult. The environment in the cask prior to the exothermic event is unknown.

In addition, the high temperatures attained during the exothermic reaction probably destroyed biological evidence that would have been of assistance in determining if there was a biological origin to the exothermic event.

Finally, funding resources and time constraints limited what could be achieved.

These reservations are stated so that it is clearly understood that Battelle-Northwest is not claiming that its studies completely addressed the potential importance of microbial metabolism on the stability of organic ion exchange resins containing low level nuclear waste materials.

Battelle-Northwest does believe that its studies indicate the potential importance of microbial action in spent resins. F 'thermore, Battelle-Northwest believes these studies have shown that the exothermic event that occurred in Cask A could have had a biological origin.

Experimental Rationale and Design If microbial metabolism was important in preparing the system for the exothermic event detected in Cask A, several conditions should have been met:

1)

The total metabolism and growth of microbes preceding the exothermic event should have been extensive.

Therefore, the resins in the cask, plus the material bound or coated on the resins, must be able to support microbial growth. As a consequence, biological polymers (i.e., DNA),

metabolic byproducts, and cell and/or microcolonies should have existed in the casks and may be detectable.

2)

The casks (and the resin storage tank) were probably anaerobic (without oxygen) prior to dewatering.

Therefore, bacterial metabolism was probably fermentative or linked to anaerobic respiration. Fermen tative metabolism requires fermentable substrates (sugars, some organic acids, 51

e tc. ). Cask A did not contain more than trace levels of fermentable substrates, hence these studies concentrated on anaerobic respiration as the main probable cause of microbial activity.

Battelle-Northwest's studies attempted to demonstrate that indicators of microbial growth were present in the resins from the casks that were not dewatered (Casks C, D, and E), partially dewatered (Cask B), and in the cask that underwent the exothermic event (Cask A).

These studies also attempted to show that both resins from the casks and new "as-received" resins are capable of supporting microbial growth and metabolism.

Anaerobic respiration has three common origins. Both bacterial nitrate reduction and bacterial sulfate reduction are probable. Methanogenesis (production of methane) by carbon dioxide reducing bacteria cannot, a priori, be excluded. However, these studies concentrated on some form of sulfate reduction as the most likely form of metabolism in the casks for the following two reasons:

1)

Several of the ton exchange resins used at ANO contain sulfonate groups j

as part of the basic repeating polymeric unit of the resin.

Tho sulfonate (-S0 -H+) group is a potential electron acceptor for sulfate 3

reducing bacteria.

2)

The resin in Cask A had a strong odor during dewatering (and is still present in Cask A resin samples) that was possibly caused by reduced sulfur compounds.

Thus, the microorganism studies attempted to enrich sulfate reducing bacteria present in cask resins, and to demonstrate the growth of sulfate reducing bacteria in inoculated resins.

Battelle-Northwest's studies were limited to one type of sulfate reducing bacteria for the inoculated resin tests.

Materials and Methods Five representative cask samples (radioactive) and eight representative resins (nonradioactive) were studied.

The representative cask samples were obtained as follows:

t 52 i

Cask A - approximately equal quantities of resin from Core Sample No.1, Sample No.1 Core Sample No. 1, Sample No. 4 Core Sample No. 1, Sample No. 5 Core Sample No. 2, Sample No. 2 Cask B - Representative sample o

Cask C - Representative sample o

Cask D - approximately equal quantities of resin from o

Sample from bottom 6 in, of core.

Representative sample from 8 in, above the bottom of the core to the top.

Cask E - approximately equal quantities of resin from o

Core Sample No. 1, Sample No. 1 Core Sample No. 1, Sample No. 2 Core Sample No. 2, Sample No. 1 Core Sample No. 2, Sample No. 2 Core Sample No. 2, Sample No. 3 Tne eight representative resin samples were obtained from AP&L, ANO site and are designated: A1010, C20-H, RWA-78, Rohm & Haas 200C, ARA-9371, Mixed 150 L/C, Rohm & Haas 900C, and ARC-9358.

The numerically designated resins were resins supplied to Battelle-Northwest by AP&L and those designations correspond to those on the sample contciners as received by Battelle-Northwest.

It is Battelle-Northwest's understanding that these resins are "as supplied" to AP&L by the various manufacturers.

No treatment of the resins was done by Battelle-Northwest.

Brief descriptions of these resins are given in Appendix 0.

Resin samples obtained from Casks A, B, C, D, and E contain resins whose identity is unknown; i.e., the manufacturer and resin-type (anion or cation) is not known.

It was possible to determine approximate volume ratios of gel and macroreticular resins in the cask. Descriptions of the cask resins are given in Appendix A.

53

A 4 gram slurry of each sample or resin was prepared and divided equally into four sterile test tubes.

Reduced Postgate medium either with or without lactate was added to the appropriate tube. Two tubes, one with lactate and one without lactate, were inoculated with a 0.1 mL aliquot of a 48 hour5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> culture of Desulfouibrio desulfuricans. The other two tubes received no organism. Appropriate organism controls, media controls, and H O controls 2

were also prepared. All tubes were incubated in an anaerobic jar at 30*C for seven days. At the end of the initial incubation period, all tubes were observed for growth and gram stains of each broth culture were prepared.

The gram stain provided a method of distinguishing two major subgroups of the bacteria Procayoces.

Incubation was allowed to continue af ter the initial seven days; additional observations for growth were noted and additional gram stains were prepared.

Initial Results The following describe the results of the initial studies described above.

Cask A.

Evidence of sulfate reducing bacteria in the uninoculated samples with or without lactate was observed based on the production of H 3 2

(see Table 5 for the results obtained for all cask samples). There was no apparent difference in growth or H S production between the samples either in 2

the presence or absence of lactate.

This observation indicates that sulfate reducing bacteria were probably present in this cask.

Cask B.

The results were similar to those observed for Cask A with the exception that less growth and H S pr duction were exhibited in the samples 2

without lactate.

Cask C.

There was evidence that other bacteria were present in this cask because of excessive gas production and lack of H S production in the 2

uninoculated samples.

Resin particles were pushed to the top of the culture tubes by the excessive gas production in both inoculated and uninoculated resin samples.

H S production was present only in the inoculated samples.

2 Microscopic examination of the inoculated samples indicated a mixture of bacteria were present.

Gram negative short curved rods and long rods, gram positive rods with spores, and gram positive cocci were observed. These short i

rods were extremely mobile when observed under wet mount preparation.

54

9

'I a

j T ABL E 5.

Growth Characteristics of Radioactive Cask Resins Cask A(*

Cask 8 Cask C Cask D *)

Cask E *I I

Density H. 5 Cas Density H,5 Cas Density. H,5 Gas Density H,S Gas Density H,S Cas -

Lactate Present Inoculated 4+

+

4+

+

4+

+

+

4+

+

4+

+

UninooJlated 4+

+

3+

+

4+

+(c )

4,

,(c) 4+

tr

+

4 I

1 Lactate Absent Inoculated 4+

+

4+

+

4+

tr

+(c )

2+

+

2+

+-

g ik inoculated 4+

+

2+

+

4+

+C 4+

+

2+

tr

+

(a) Pooled samples (See Materials and Methods Section)

(b)

Growth density is a visual measurement of the amount of turbidity and H S Pro &ction on top and throutpout the sample 2

j

( i. e., 4+, 3+, 2+,

1+, t r ).

(c)

Excessive gas proiction (resin particles pushed to the top of the tihes).

i i

t I

4

. ~.

_ -. _ =

i Cask D The results for Cask D were similar to those obtained for Cask C.

Cask E.

The results for Cask E were similar to those obtained for casks C and D.

However, a trace of H S was also present in the uninoculated 2

' samples. Microscopic examination also indicated a variety of morphologically different bacteria. Both sulfate reducing bacteria and other anaerobic bacteria appeared to be present in Cask E.

Nonradioactive Resins. All inoculated samples of the nonradioactive resins had evidence of H S production and bacterial growth with the exception 2

of C20-H and ARC-9358.

The inoculated samples without lactate showed less growth than those samples with lactate.

All uninoculated samples had no evidence of bacterial growth or H 5 2

j production with the exception of the RWA-78 resin.

In RWA-78 samples, a mold-like growth occurred on the surface of the resin in both the inoculated and uninoculated samples containing lactate.

In addition, the uninoculated sample of. RWA-78 showed a trace of H S production indicating some sulfate reduction 2

occurred.

i I

j Discussion of Initial Results The initial results reported above established the following:

1) The sulfate reducing bacteria Dasulfovibrio desalfuricans used to inoculate the various resin samples was shown to grow in reduced Postgate medium containing resins from each of the casks (Casks A, B, C, D, and E).

This organism produced H S in these experiments, both in the 2

presence and absence of lactate in the medium.

Lactate is a suitable carbon source for this organism, and was added for enrichment of the i

sulfate reducing bacteria in certain samples of the total experimental matrix.

However, growth in the samples without lactate indicates a suitable substrate or energy source existed in the cask resins.

i

2) Desulfovibrio desulfuricans was shown to grow in reduced Postgate medium i-containing each of the nonradioactive resins with the exception of C20-H and ARC-9358.

However, samples without lactate seemed to show less bacterial growth than those samples containing lactate.

In addition, l-56 i

the uninoculated sample of RWA-78 showed a trace of H S production 2

indicating some sulfate reduction occurred.

- 3) Resins from Casks A, B, and E when inoculated alone into reduced Postgate medium showed bacterial growth and H S production, possibly 2

indicating the presence of Deautfovibrio desulfuricans or other anaerobic sulfate reducers in the resins. Bacterial growth and H S 2

production occurred with these resins whether lactate was present or absent from the medium, indicating a sufficient energy source for anaerobic bacterial growth was present in these resins without the addition of lactate. A small gram negative curved rod was found to be the predominant organism in gram stains of cultures from resins obtained from Casks A and B.

4)

Resins from Casks C, D, and E indicated a variety of morphologic bacterial types on microscopic examination.

These included gram-negative rods, gram positive rods with or without spores, and gram-positive cocci.

>'}

Additional Results Following the initial studies, additional experiments were conducted to more fully define the potential-for bacterial growth in resins obtained from Casks A. B, C, D, and E.

Preliminary efforts to isolate and identify specific microorganisms from these casks were also conducted.

The results of these additional studies are described below:

1) Resins from Casks A, B, C, D, and E gave no evidence of bacterial growth whenlincubated in sterile distilled water.

})

Resins from Casks A through E in reduced Postgate medium containing no sulfate in the medium supported bacterial growth and H S production when 2

inoculated with Desulfovibrio desulfuricans and incubated anaerobically.

The Postgate medium used in all of the initial tests

- contained sulfate in the medium.

The presence of bacterial growth and H S production in the present tests indicates the added organism can 2

grow in the presence of the resins alone, apparently using the organic 57

residuals and sulfonated groups present in the resins to establish growth.

3) Samples from Casks A, B, and E incubated anaerobically in Postgate medium without sulfate showed H S production (indicating sulfate 2

reduction) af ter 7 days; samples from Casks C and D did not show H 3 2

production under identical conditions.

4) A number of organisms isolated from the various resins in Postgate medium without sulfate were partially identified.

0.1 mL aliquots from each of the resin-medium tubes showing bacterial growth were plated.onto Postgate-sulfate agar and nutrient agar.

These plates were then incubated both aerobically and anaerobically at room temperature.

All resins were found to contain a gram-negative rod which was oxidase positive and is a Pseudomnos species. Although usually found as an aerobe, these organisms can respire anaerobically using nitrate as a final electron acceptor.

A gram positive spore-forming anaerobe, a clostridium species, was isolated from resins obtained from Casks A, C, D, and E.

This organism is capable of producing copious amounts of gas (not H 3)-

2 A medium sized gram-positive rod which did not produce spores and grew both aerobically and anaerobically was isolated from resins obtained from Casks C, D, and E.

Based on microscopic and colonial morphology, this organism appears to be a Corynebacterium species.

Finally, a small vibriod gram-negative rod was isolated from resin obtained from Cask B.

This organism is a strict anaerobe (i.e., Desulfouibrio species) which is fairly fastidious and seemed to be lost easily on transfer.

Discussion of Additional Results A variety of morphological bacterial types were shown to exist in resin samples obtained from Casks A, B, C, D, and E.

Further, both added known sulfate reducing bacteria and the bacterial types existing in the cask resins were shown to be capable of bacterial growth in the absence of both added sulfate and lactate. Certain bacterial types that produced copious amounts of 58

gas (not H S) under anaerobic conditions were shown to be present in all casks 2

except Cask B.

Conclusions l

The purpose of the microorganism studies was to determine if the presence of microorganisms in organic ic.) exchange resins contained in Casks A, B, C, D, and E could be shown. Further, if these microorganisms existed, would they

)

show growth under conditions approximating those expected for the casks and the resin holding tank from which the casks were loaded?

It has been shown unequivocally that a variety of morphological bacterial types existed in the resin samples obtained from Casks A through E.

Bacteria contained in Casks A, B, and E were shown to be capable of growth under anaerobic conditions, apparently utilizing only residual organics and the sulfonate groups of the resin to support growth.

It is significant to note that Casks A, B, and E contained resins which had been in the resin holding tank for the greatest period of time. However, all cask resins were capable of supporting sulfate-reducing bacterial growth as was shown in those samples inoculated with Desulfooibrio desalfuricans. Thus, time is expected to be a significant factor in determining the level of bacterial growth present in any given cask, and may also determine the predominant bacterial species.

It has also been shown unequivocally that most of the new resins supplied to Battelle-Northwest by AP&L are capable of supporting bacterial growth.

The nonradioactive resins (C20-H and ARC-9358) which inhibited growth of the tester organism are similar in their polystyrene matrix and are known for their chemical resistance. This chemical resistance may not allow the organism to attack the resin and therefore inhibits or prevents the reduction of the sulfonate groups. The H+ form of both C20-H and ARC-9358 resins may also contribute to their resistance to microorganism growth.

To our knowledge, the area of microbial growth in organic icn exchange resins has received little previous study. Organic fouling of resins is a well-recognized phenomena that is somewhat related, but the main concern has been the resultant loss in exchange capacity, not the potential for microbial 59

grow th.

Our studies have indicated that microbial growth in ion exchange resins may be an area requiring additional studies, particularly if our hypothesis that the presence of a significant microbial population contributed to the initiation of the exothermic event detected in Cask A is shown to be a plausible hypothesis.

SIMULATED DEWATERING TEST The objective of the simulated dewatering test was to monitor events potentially leading to the exotherm observed in Cask A.

Samples from:

Casks A, B, C, D, and E; Cask E spiked with the microorganism Desulfouibrio desulfuricans; and new ton exchange resins obtained from AP&L (Rohm & Haas 200C, Diamond Shamrock A1010, Mixed 150 L/C, RWA-78, ARC-9358, Diamond Shamrock C20-H, ARA-9371, and Rohm & Haas 900C) were temperature monitored under various air flow rates.

In no case was a significant temperature rise observed.

Experimental parameters for the simulated dewatering tests were selected based on calculations with known AP&L operating conditions and laboratory limi tation s.

AP&L parameters for the resin bed included: 2900 L volume; 2

17,037 cm cross-sectional area, 2.6-6.5 L/sec air flow rate; and 30-40% void volume.

Scaling the airflow rate on a face velocity basis for the laboratory resin bed volume of 300 mL resulted in a value of 650-1625 mL/ min; a value not practical for laboratory operation.

Therefore, the airflow rate was raticed by resin bed volume resulting in a recommended laboratory airflow of 26-65 mL/ min.

Calculations based on assumptions made in the thermodynamic studies predict a temperature rise of 7-23 *C/h, if 100% of the oxygen is used for resin combustion in the 300 mL laboratory resin bed.

Details of these and previously mentioned experimental parameter calculations pertaining to the simulated dewatering test are given in Appendix F.

Simulated Dewatering Test Results A summary of the simulated dewatering test results is provided in Table 6.

Two air flow rates were used in Tests No.1, 2, and 4.

Samples in Test No. 4 were preheated before temperature monitoring began.

60

TABLE 6.

Summary of Simulated Dewatering Tests Test No.

1 2

3 4

Cask E, Cask E IAI Cask A, Cask B, with flicroorganism New lon Exchange A1010, Mixed 150 L/C, Sample (s)

Cask C, Cask D Spike Resins ARC-9358, ARC-9371 Air flow rate 40 80 40 80 35-45 0

40 mL/ min Initial Temp., *C 20 21 22-23 20.5 22-24 58-69 54-62 Temp. range, 20-24 20.5-21.8 20.5-23 20-22.5 20-24 dropping dropping

  • C, over total to 22 to 28-32 run period flaximum time 109 95 122 165 115 79 6

of run, hours l

(a)

New resins are Rohm and Haas 200C, Diamond Shamrock A1010, Mixed 150 L/C, RWA-78, ARC-9358, Diamond Shamrock C-20H, ARA-9371, and Rohm and Haas 900C.

i

Discussion of Simulated Dewatering Test Results The instrumented simulated dewatering tests indicated no significant increase in temperature during the process for either the new or cask resins supplied by AP&L. Minor fluctuations in temperature obtained are within the expected deviations for this type of study.

Because we believe oxygen (in air) was the required oxidant for the exothermic event noted in Cask A on January 15, 1983, a continuous airflow was maintained during the dewatering tests to maximize the availability of oxygen.

The air flow rates were also increased on most tests after several days at the calculated cask-equivalent airflow rates.

No temperature changes were noted at any of the flow rates used.

In addition, other tests used the actual dewatering cycle of 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> of airflow (pumping) and 16 hours1.851852e-4 days <br />0.00444 hours <br />2.645503e-5 weeks <br />6.088e-6 months <br /> of static conditions (dewatering cycle times should be considered proprietary information); no temperature changes were noted for these tests.

Thus, no significant changes in the temperature of the resin were found using the laboratory conditions specified.

Laboratory-scale dewatering tests suffer from the inevitable scaling factor required to conduct the work.

The laboratory-scale tests utilize a 4

resin volume ~10 less than the volume of the actual cask. Although the laboratory tests were conducted in insulated vessels to try and maintain adiabatic conditions, the actual cask and resin has a much greater potential for retaining any heat generated during dewatering.

The fact that no significant temperature changes were noted during the laboratory-scale tests does not preclude temperature changes occurring in the actual cask under otherwise identical conditions.

The uncertainties associated with any laboratory-scale dewatering tests are largely those of scale, but the effects of the scaling cannot be accurately predicted for these studies.

Battelle-Northwest recommends that fully instrumented dewatering tests be conducted on actual resin disposal casks in accordance with accepted dewatering practices.

The instrumented full-scale dewatering would give an experience base useful in detecting any abnormal behavior such as a significant increase in temperature.

Furthermore, any abnormal behavior is expected to be easily detected without fear of an 62

extremely rapid or "run-away" reaction if air-oxidation was the cause of the exotherm in Cask A.

f I

63

APPENDIX A DESCRIPTION OF CASK RESINS Resin samples from Casks A, B, C, D, and E, located at ANO, were obtained by using a core sampler designed, constructed, and furnished by Battelle-Northwest. Each core sample was divided into the various samples described in the following text. Sample descriptio1s include those recorded during the actual cask sampling. Additional descriptive information was obtained later at Battelle-Northwest.

Visual examination of various cask resin samples were also conducted using optical microscopy.

DESCRIPTION OF CASK CORE SAMPLES Core samples of the resins contained in Casks A, B, C, D, and E, located at ANO, were obtained.

The following text describes these core samples.

Cask A, Core Sample No. 1 Cask A was a 103 cubic foot resin disposal liner.

The cask had been refilled with water on January 15, 1983, af ter the exothermic event had been de tected.

The cask was not sealed but was inside a plastic " greenhouse."

Core Sample No. I was obtained on August 2,1983, at about 1030 hours0.0119 days <br />0.286 hours <br />0.0017 weeks <br />3.91915e-4 months <br />.

Core Sample No. I was obtained by inserting the sampler vertically into the resin bed about ten inches from the exact center of the cask.

Some resistance was experienced in inserting the sampler into the resin bed; this was apparently caused by a crust on the resin bed.

Some resin was lost from the sampler during its withdrawal from the resin bed because the shutter on the sampler was not completely closed.

Later inspection of the resin core and sampler showed that about four inches of resin from the core were lost.

The liquid that initially drained from the sampler upon its withdrawal was black and then turned clear. We believe the initial black appearance was caused by resin escaping from the incompletely closed shutter.

A.1

A faint odor was present when the sampler was withdrawn from Cask A.

The odor could best be described as " sewer-like," " sewer gas," or similar to that of a just-opened septic tank.

It did not have any characteristic amine odor.

The resin in the bottom of the sampler appeared black for about the lower ten inches of the core.

There was a gradation in appearance for about another ten inches, and the remainder appeared to be a brown / black mixture.

The resin core had about a one-eighth inch thick crust at the top of the core.

The following samples were obtained from Cask A, Core Sample No.1.

Sample No. 1.

The bottom six inches of the core. All of the resin had a black appearance.

Sample No. 2.

Representative material from 6 in, above the bottom to e

18 in, above the bottom of the core, Sample No. 3.

A solid " chunk" of resin located seven inches from the o

bottom of the core.

o Sample No. 4.

Representative material from 1 f t. 6 in, above the bottom of the core to the top of the core, 3 f t. 2 in.

Resin " chunks" were found randomly thoughout the entire core sample; each of the above samples contained at least one.

The resin " chunks" are all very dark. The resin beads in the " chunks" appeared to be somewhat smaller and had a glassy-look with a red / black color.

The resin core was 3 f t. 2 in. in depth; the original depth of resin (before sona loss occurred during withdrawal of the sampler from the cask) appeared to have been about 3 ft. 6 in.

Cask A, Core Sample No. 2 Cask A, Core Sample No. 2, was obtained on August 2,1983, at about 1300 hours0.015 days <br />0.361 hours <br />0.00215 weeks <br />4.9465e-4 months <br />. Core Sample No. 2 was an attempt to obtain resin from near the liner wall at the bottom of the cask. The sampler was inserted at an angle with the sampler entering near the center of the cask opening, and the bottom of the sampler ending at the liner wall on the cask bottom.

A.2

Several gas bubbles were observed when the sampler was inserted into the resin. Gas bubbles had also been noted when the sampler was inserted to obtain Core Sample No. 1.

The personnel inserting the sampler indicated it took "an effort" to push the sampler through the surface crust at the top of the resin bed.

There was no apparent resin loss from the sampler when it was withdrawn from the cask.

The resin at the bottom of the core was black in appearance but did not appear to be as dark as that found at the bottom of Core Sample No.1.

The remainder of the resin core appeared to be a brown / black mixture as observed in Core Sample No. 1.

The following samples were obtained from Cask A, Core Sample No. 2.

Sample No. 1.

Material from the lower six inches of the core. One large chunk of resin was included in this sample.

Sample No. 2.

Representative material from 6 in, above the bottom of the core to the top of the core.

o Sample No. 3.

The crust from the top of the core and a chunk of material obtained about 8 in, from the top, o

Sample No. 4.

A thin 3/4 in, thick layer about 8 in. above the bottom of the core.

This material was not stuck together but had a different visual appearance. All lighter color resins in this sample were from the inability to prevent some mixing when taking the sample.

Cask B, Representative Sample Cask B contained resin that had been removed from the resin holding tank immediately af ter Cask A was filled. Cask B had undergone two cycles of dewatering but was backfilled with water after the exothermic event in Cask A was detected. Cask B was not sealed and was inside the " greenhouse" with Cask A.

Algae or similar growth was very apparent in the liquid on the top of the material in Cask B; this is not unusual because of the long time period the cask had been open to the atmosphere.

A.3

A single core sample was obtained from Cask B on August 2,1983, at about 1430 hours0.0166 days <br />0.397 hours <br />0.00236 weeks <br />5.44115e-4 months <br />.

The core was obtained by inserting the sampler vertically into the resin bed near the center of the cask opening.

Some gas bubbles were observed during the sampling, but there was no apparent odor at Cask B.

The very bottom 1 in. of the core contained mostly whitish resin beads which were later identified as a macroreticular resin.

The total depth of the resin core sample was 3 ft. 6 in.

A single sample, representative of the total core was taken. This sample excluded the whitish resin at the very bottom and the very top which obviously contained " pond muck" as a result of the water draining through the core. The resin in the core was " brown;" i.e.,

it didn't look like new resin, but it did not have the mixed brown / black appearance of the core samples from Cask A.

However, there are dark resin beads present in the core from Cask 8 - this may indicate that the dark resin is not necessarily associated with the conditions of the exothermic event that occurred in Cask A.

Cask C, Representative Sample Casks C, 0, and E had approximate internal volumes of 164 cubic feet whereas Casks A and B were smaller, having volumes of approximately 103 cubic feet. Casks C, D, and E also were filled af ter additional spent resin had been added to the resin storage tank.

The approximate total mixture of "old" and " newer" resins in the resin storage tank at the time of loading Casks C, D, and E was ~130 cubic feet of "old" resin and ~270 cubic feet of " newer" resin.

Casks C, 0, and E had been sealed since their filling and were opened just prior to obtaining the core samples.

The distinctive odor associated with Cask A was not apparent in any of these casks.

A single core sample was obtained from Cask C on August 3,1983, at about 0930 hours0.0108 days <br />0.258 hours <br />0.00154 weeks <br />3.53865e-4 months <br />. The core was obtained by inserting the sampler vertically into the resin bed near the center of the cask opening. No difficulties were observed in inserting the sampler.

A.4

Resin was lost from the sampler during the withdrawal because the shutter did not completely close. Later examination indicated that as much as 12 in.

of resin may have been lost.

The length of the core was 3 ft. 6 in., but indications are that the resin bed in the cask was 4 ft. 6 in. deep.

The bottom few inches of the core were somewhat darker in color to the eye, but the core generally contained resin that was "new" in appearance, i.e., yellowish in color, not brown or black. A sir.gle sample was obtained by sampling the entire core to obtain a representative sample. Material at the very top of the core was excluded from the representative sample. Microscopic observation of a sample obtained from the darkar region of the core showed the presence of a very few dark resin beads.

Cask D, Representative Sample A single core sample was obtained from Cask D on August 3,1983, at about 1100 hours0.0127 days <br />0.306 hours <br />0.00182 weeks <br />4.1855e-4 months <br />. The core was obtained by inserting the sampler vertically into the resin bed near the center of the cask opening.

No difficulties were observed in inserting the sampler.

The resin core separated in two places during transport, but no resin was lost nor should the profile have been changed.

The length of the resin core was 4 f t. 4 in.

The resin located in the lower six inches of the core was darker than the remainder of the core.

The personnel doing the sample transfers from the core to the sample bottles stated there were very dark or black resin beads throughout the core.

Microscope samples taken at 2 in. from the bottom of the core indicated the presence of grayish macroreticular resin, brown macroreticular resin, and l

several black beads.

A microscope sample taken at 2 f t. 6 in. above the bottom of the core had clear gel resins, amber gel resins, and black and/or very reddi sh beads.

i l

l l

A.5 l

The following samples were obtained from Cask D.

Sample Cask D1.

Bottom 6 in of core, o

Sample Cask D2.

Representative sample from 8 in above the bottom of o

the core to its top.

Cask E, Core Sample No. 1 Cask E was the last cask loaded during the cleanout of the resin storage tank.

The final cleanout of the resin storage tank required the use of high pressure water streams to remove " caked" resin from the walls, and this material was loaded into Cask E.

Cask E was opened and sampled on August 3,1983, during the af ternoon.

The individual who opened the cask stated there was a " rotten" smell present when the cask lid was first removed.

However, within fif teen minutes no odor was apparent to several people who approached the cask opening.

It was also stated by the individual who opened Casks C, D, and E, that Casks C and D also had the same " rotten" smell when their lids were first removed.

The surface of the liquid in Cask E was completely covered (visual observation through the cask opening) with a layer of oily scum, with some clear oil floating in globules. A sample of the oily material was taken.

The thickness of the scum layer in the cask was measured to be about 3/8 in. - 1/2 in.

Core Sample No. I was obtained by inserting the sampler vertically into the cask near the center of the cask opening.

Bubbles were released during the time period of obtaining the core sample.

The personnel conducting the core sampling stated the rotten smell was present when the sampler was inserted and withdrawn.

However, all personnel stated the " rotten" odor detected in Casks C, D, and E was not that associated with Cask A.

The depth of the resin bed in Cask E was only one foot; the remainder of Cask E contained only water with the oily material at the liquid surface.

A.6

The following samples were obtained from Cask E, Core Sample No.1.

Sample No.1, Resin from the lower 3 in of the core.

o Sample No. 2.

Resin from the upper 6 in. of the core.

Microscopic evaluation of samples taken from the core indicated the lowest 3 in. of the core contained essentially all gel-type resins while the upper portion of the core contained mostly macroreticular resin.

A sample of water was also taken from Cask E.

Cask E, Core Sample No. 2 Core Sample No. 2 was taken to obtain resin from near the liner walls.

The core was obtained by inserting the sampler at an angle from near the center of the cask opening and having the bottom of the sampler at the liner wall on the bottom of the cask.

The core sample was ten inches deep. The lower three inches of the core contained darker resins. Grayish macroreticular resins predominated in the remainder of the core.

The following samples were obtained from Cask E, Core Sample No. 2:

Sample No. 1.

Some sludge and resins taken at the very bottom of the Core.

Sample No. 2.

Red-looking resin beads located at the bottom of the

Core, o

Sample No. 3.

Sampled core from ~3 in, above bottom to top. Mostly macroreticular resins. Sludge from the very top of the resin core was excluded.

MICROSCOPIC EXAl11 NATION OF AP&L CASK RESINS Visual examinations of various core samples obtained from Casks A, B, C, 0, and E were obtained using optical microscopy.

The purpose of these studies j

was to determine the type of resin present (gel or macroreticular) and the j

resin appearance.

The following text identifies the samples examined by I

optical microscopy and describes these observations.

A.7

Cask A, Core No.1, Sample No.1 Examination of this sample in the sample bottle with a bright light indicated that all beads were a bright (glistening) shiny black except for a very small portion (~2%) of macroreticular beads.

Examination of this sample under a microscope indicated that not all the beads were black charred beads.

It appeared that many gel-type beads were present with an oily film on their surface, and that this film contained fine black material (probably char).

It was very difficult to determine how many beads were truly black and how many were only coated. Many (most) of these beads floated on water and appeared hydrophobic.

Three samples of this resin were washed with 3 solvents; CCl, ethanol, 4

and xylene. All of these removed appreciable brown color, xylene the most, a

and CCl the least, and after such treatment, the beads no longer appeared 4

coated.

No H O was added.

Af ter some evaporation Examination Af ter Xylene Wash.

2 of xylene, the beads, although not appearing coated as before, still appeared hydrophobic with most floating and appearing to stick together somewhat.

The sample was then washed twice with acetone and again placed in H 0.

At this 2

point very few beads floated, and the resin was not surface coated.

Less than 10% of the beads were macroreticular.

Various stages of pyrolysis appeared to be present in both the gel-type and macroreticular resin.

These ranged in appearance from what appeared to be carbon beads through strongly colored but clear to only yellow beads. Many fragments were present, including both resin fragments and carbon particles.

Probably much less than 10% of resin was totally carbonized, but many beads were very dark and appeared to have some spots of carbonization on them.

One brown macroreticular bead was present with sufficient breakage to see that its interior was white.

Other brown to tan macroreticular beads were of ten cracked, but the cracks were not sufficiently open to see the interior of the bead.

A.8

r

,-------_-_--,-+,n-,

,,__-_,.,._w

_--,m,,,_,--_.-_

Cask A, Core No. 1, Sample No. 2 This resin appeared to have an oily film and to be somewhat hydrophobic but did not have the mass of fine black material on the bead surfaces. After two acetone washes this oily film appeared to have been removed.

The resin (except for totally blackened beads) appeared to be about 80%

macroreticular. Some of the gel-type resin, and a very few macroreticular beads, appeared to have the grey surface coating described above, but this appeared to be less extensive and not as great on each bead as in the sample immediately below.

There did appear to be a slightly higher proportion of totally opaque (charred) black beads but fewer black fragments. Most of the black beads appeared quite solid although several showed extensive surface cracking in a network very similar to the surface-cracked brown macroreticular beads observed before, and of which there are a few in this sample.

These black beads definitely looked different and were certainly much less cracked, broken, and distorted than the black beads in the lower portion of the core.

A few very grey opaque beads were seen. One grey bead had at least four round spots where it appeared to have touched other beads.

The round spots were white macroreticular resin showing through.

Except for this area, one can see only a slight amount of light resin showing throug5.

Another macroreticular bead had many grey spots that appeared almost as if they were nucleation sites for crystallization of porous metal.

It appeared that a major portion of the truly opaque carbonized beads were produced from macroreticular beads.

One large grey macroreticular bead was broken and was largely of f-white inside but with two or three discrete grey spots inside the bead.

It appeared that this may have been due to the beginning of carbonization.

During solvent cleaning this material did not have any appreciable fine black solids suspended in the organic, unlike the samples in the lower portion of the core. This, again, points to the greater physical stability of the charred beads in this region.

A very small amount of brick-red, porous looking particles were found which were not shaped like resin beads at all.

The sample also contained some broken chips (fines) of both gel-type and macroreticular resin.

A.9

Cask A, Core No. 1, Sample No. 3 This sample consisted of a resin lump which was sufficiently hard that it made a crunching sound when a 1/2 in. piece was cut off with a scoopula.

The lump (1/2 in, piece) was washed with acetone (removing very little color) to rinse " tramp" beads of f the lump.

The small lump was examined and found to be completely pyrolized with sintering.

No unpyrolized beads were observed.

Cask A, Core No. 1, Sample No. 4 Although this sample appeared to have a slight hydrophobic film, it did not appear to have any black particulates on the beads.

H 0 was added, and 2

the resin was easily examined without solvent washing.

The resin suspension was clean with fines being almost entirely broken, uncharred bead fragments.

This resin was also mostly (~75-80%) macroreticular.

It contained somewhat fewer carbonized beads than the zone just below. Otherwise, the sample was similar in that the charred beads appeared to be intact, of ten with

" alligator hide" surface cracking but also often with a shiny surface.

There were some dark brown macroreticular beads, including ones showing lighter spots where they had contacted other beads.

The gel-type beads were not coated with grey material, although there appeared to be some (but less than samples obtained lower in the core) on the carbonized beads.

One macroreticular bead was observed with several (~100) very discrete dark grey spots with sharp boundaries.

The grey was an opaque metallic grey, as also noted in a few beads in Core No.1, Sample No. 2.

Reflection (these may be incipient localized nucleated charring) faces occurred in these dark grey spots but were too small to determine with certainty if they were crystal faces. The charred beads were 10 to 15% of the total.

A.10

Cask A, Core No.1, Resin Above 30 in. Level (only a microscope sample was taken)

This sample was in H O and not solvent washed.

It had a lot of fine 2

cream-colored particles much smaller than the resin beads floating in the water.

It had some resin in clumps with the void spaces completely filled with what appeared to be this same material.

It looked very much like it might be biofouling. This sample looked much like the one just below in quantity and nature of carbonized beads. The gel-type and charred beads had a large amount of greyish surface " crud" on them unlike the sample below.

Cask A, Core No. 2, Sample No. 1 The resin in this sample had an oily film similar to the same region in Core 1.

Acetone was added to the sample but the sample was not washed; the oil film came 'ff.

The sample had many carbon particles and broken carbonized o

beads. The resin was mostly gel-type. Many, but not all of the carbonized beads were coated with tan to brown crud as were many of the noncharred gel-beads. Many carbon shells of beads exist.

The resin in this sample is i

probably 30+~ carbonized.

Cask A, Core No. 2, Sample No. 2 This sample, as obtained in H 0, showed all of the features seen in a 2

composite of all samples of Core 1 above the 8 in. level.

This included about the same percentage of carbonized beads, macroreticular resin, surface crud, possible biofouling, brown macroreticular beads, grey macroreticular beads, etc.

Cask A, Core No. 2, Sample No. 4 l

l This resin was probably about 20% macroreticular.

The resin (gel) varied from black to clear beads with relatively few (10-20%) actual charred beads, i

Most of the near black or deep red beads had blobs and patches of porous grey f

to grey-brown material on the surface.

Not all beads had this (only one or two macroporous beads were found with it). The material appeared somewhat i

[

similar to grey metallic sponge and showed up on some (most), but by no means A.11 I

i

all, of the light colored gel beads.

It was definitely not present to as great an extent in the sample of the bottom six inches of resin, despite beads of varying colors from pale yellow to jet black being present in that solvent washed sample.

Cask E, Core No. 2, Sample No. 3 This sample had some resin clumps with beads or bead fragments cemented together with light crusty material. Some other beads had some surface crusting of light to greyish material. Among the gel-type beads, there were some very deep red beads. All beads, but in particular the macroreticular ones, showed some surface crazing that appeared to be impact related.

This may be related to the high pressure water stream used to remove this resin from the resin storage tank.

Some of the brown surfaced macroreticular beads had been chipped, and these appeared to be whiter inside than on the surface.

In contrast to this sample, the Cask B macroreticular resin (bottom of core) was much shinter on the surface (less surface chipping, etc.) and also appeared to be whiter (less brown beads). Also, in this sample, there did not appear to be any surface deposits or cementing.

In Core 1 of Cask E, the macroreticular resin appeared similar to that in Core 2 of Cask E, but no crusty deposits were observed in the microscope sample.

A.12

f APPENDIX B CNSI SOLIDIFICATION WORKSHEET 1 (PCP SOLIDIFICATION OF PARTICULATE WASTES)

Appendix B contains proprietary information and has been withheld from public disclosure per the provisions of 10 CFR 2.790.

e

APPENDIX C BATTELLE - NORTHWEST LABORATORY PROCEDURES FOR SOLIDIFICATION OF ION EXCHANGE RESINS Appendix C contains proprietary information and has been withheld from public disclosure per the provisions of 10 CFR 2.790.

t D

e

APPENDIX D DESCRIPTION OF NEW ION EXCHANGE RESINS FURNISHED BY ARKANSAS POWER AND LIGHT COMPAt4Y, ARKANSAS NUCLEAR No. ONE lon exchange resins are used for various purposes by Arkansas Power and Light Company at Arkansas Nuclear No. One. Specific resins are selected by AP&L in accordance with their desired use and the normal purchasing practices of AP&L. Samples of new resins were furnished to Battelle-Northwest by AP&L for the purpose of conducting resin solidification tests.

The manufacturers and identification codes are given.

Visual examination of the various core samples obtained from the casks indicated varying amounts of gel and macroreticular resins present in each cask. The functional group, or polymeric unit, of the resins in the casks was not determined. Thus, the casks contain resins known to have been used at ANO, but the manufacturer, identification code, and functional group of the resins in the casks is not known.

Battelle-Northwest's resin solidification studies were conducted, using the Chem-Nuclear Systems, Inc. solidification procedure, to determine if potentially hazardous or unanticipated reactions would occur as a result of solidt fication of the spent resins contained in Casks A, B, C, 0, and E.

Solidification tests of the new resins furnished by AP&L were conducted as a reference to those conducted with cask resins.

Therefore, solidification of cask resins should give results within the range of results obtained for the new resins if no unusual or unexpected reactions occur as a result of solidifying the cask resins.

Brief descriptions of the new resins furnished by AP&L are given in the following text. llore detailed information should be obtained from the manu facturers.

D.1

IRA-200C IRA-200C is the trade name of a strongly acidic cation exchange resin manufactured by Rohm and Haas Company. The polymeric unit is shown below with brief comments also given.

H H I

I

-C-C-C H H-C C-H I

N H-C

,C-H C

isofH*

n The resin is crosslinked with about 20% divinylbenzene, meaning that about every fif th benzene ring is attached to two aliphatic chains.

Because divinylbenzene normally contains up to 50% ethylstyrene, there will also be ethyl groups, not part of the polymer chain, attached to some benzene rings.

This is a macroreticular resin.

IRA-900C IRA-900C is the trade name of a strongly basic anion exchange resin manufactured by Rohm and Haas Company which derives its exchange activity from quaternary ammonium groups.

The polymeric unit is shown below.

H H l

1

-C-C-1 i

  1. s H-C C-H l

H-C C-H 1

H-C-H I

HC-N-CH*

3 3

CH oH-3 D.2

l This resin is also crosslinked with divinylbenzene - see comments given for IRA-200C.

This is a macroreticular resin.

A-101 D Duolite A-101 D is the identification number of a strong-base anion i

exchanger manufactured by Diamond Shamrock Chemical Company. The basic repeating unit is the same as for IRA-900C. The crosslinking is done af ter the polymerization is complete (unlike most other polystyrene resins). We do not know the crosslinking agent, but there are reasons to believe it is not divinylbenzene.

The sample we received from APal is a gel-type resin.

I ARC-9358 ARC-9358 is believed to be Duolite ARC-358, the identification number of a strongly acidic cation exchange resin manufactured by Diamond Shamrock Chemical Company. The basic repeating unit is the same as that for IRA-200C, but with only 8% divinylbenzene crosslinking.

This is a gel-type resin.

C20-H Duolite C20-H is the identification number of a resin manufactured by Diamond Shamrock Company.

It is the same resin as ARC-358 but is a standard i

grade whereas ARC-358 is a high purity grade.

This is a gel-type resin.

l ARA-9371 ARA-9371 is believed to be ARA-371, the identification number of an intermediate strength basic anion exchange resin manufactured by Diamond Shamrock Company. ARA-371 is an epoxy polyamine resin, but we do not know its exact structure. A possible structure based on the condensation of polyethyleneamine and epichlorohydrin is given below.

This is a gel-type resin.

j D.3

H-C-H E

H-C-OH I

H-C-H H H H H H H H H I

l 1

l i

i i

1

+

..C-N-C-C-N-C-C-N-C-C OH -

1 I

I i

i I

l H

H H H H H H H-C-H H-C-H I

H - C - OH H - C - OH I

H-C-H H-C-H RWA-78 We believe the designation RWA-78 may refer to IRN-78, a strongly basic anion exchange resin manufactured by Rohm and Haas Company.

The parent resin of IRN-78 is IRA-400, a polystyrene resin with divinylbenzene crosslinkage that derives its exchange capacity from quaternary ammonium groups.

-IRN-78 is a gel-type resin.

Mixed 150/LC We believe the designation " Mixed 150 L/C" may refer to IRN-150, a designation of a mixture of resins manufactured by Rohm and Haas.

IRN-150 is a mixture of strongly acidic cation exchange resin and strongly basic anion exchange resin blended to have equivalent H+ and 011-capacities.

IRN-150 is a blend of IRN-77 and IRN-78.

IRN-77's parent resin is IR-120, a strongly acidic cation resin based on polystyrene with divinylbenzene crosslinkage.

IRN-78 has already been described.

This is a mixture of gel-type resins.

D.4

APPENDIX E HEAT CAPACITY AND HEATS OF SOLIDIFICATION STUDIES Thermal analysis techniques were utilized to determine the heat capacity of cement-solidified resin samples.

In addition, laboratory-scale solidification tests were conducted in calorimetry cells on both cask and new resin samples. The heat capacity and rate of heat loss from the calorimetry system were also determined.

These results were combined, as shown below, to determine the heats of solidification for the cement-solidified resins.

Heat Capacities of Cement-Solidified Resins The heat cap. city, C, of cement-solidified resin samples was determined p

using a Perkin-Elwer D':C-2 differential scanning calorimeter (DSC). A DSC measures heat ch.Uges in a material or chemical system as a function of temperature; the measurements may be obtained either isothermally or at a constant temperature increase.

The heat capacity, C, is the change in heat content, AH, as a function p

of a change in temperature, AT.

C = AH/AT p

A DSC measures AH/at, where at is the change in time at a constant AT/at.

Therefore, C can be determined using the relationship p

AH/at C

=

p AT/at

  • i The experimentally determined heat capacities for the cement-solidified resin samples and for a sapphire standard are given in Table E-1.

L i

(

l E.1

TABLE E-1.

Heat Capacities of Selected Cement-Solidified Resin C, cal /g/deg o

Sapphire, Sapphire ~, Diamond ShamrockI4) Rohm & Haas,(a)

Temp., K ; ( *C)

Actual Experimental C20-H, Solidified 200C, Solidified 298; (25) 0.185 0.185 0.222 0.312 303; (30) 0.188 0.183 0.244 0.350 313; (40) 0.192 0.191 0.310 0.439 323; (50) 0.197 0.199 0.407 0.567 333; (60) 0.201 0.204 0.544 0.737 (a) Linear regression, C = a + bT where the temperature, T, ranged from 298-333*K for Diamond ShSmgock C20-H and Rohm & Haas 200C gave the following respective results: r, correlation coefficient = 0.967, 0.98; a = -2.487, -3.28; and b = 0.009, 0.012.

The cement-solidifled Diamond Shamrock C20-H sample contained a large relative amount of resin, while the cement-solidified Rohm and Haas 200C sample contained a low relative amount of resin.

These two samples were chosen as " representative" samples of the resin solidification tests.

Agreement between actual and experimental values of the heat capacity of sapphire are quite good. The variation in heat capacity between the two actual cement-solidified resins chosen for analysis was probably caused by differences in water content. A rerun of the cement-solidified Rohm and Haas 200C sample showed a large decrease in heat capacity, especially at 60*C; this decrease is attributable to loss of water during the first DSC test.

The heat capacity values for cement solidified resins were used to determine the heats of solidification as described in the report.

E.2

Measurement of the Heat Capacities and Rate of Heat loss of the Calorimetric Cells Used for Temperature Monitoring of Resin Solidification in Cement The objective of this work was to measure the heat capacity of the large and small dewar calorimetric systems used to measure the temperature rise for tt the cement solidification of Arkansas Power and Light ion exchange resins.

This was accomplished by introducing a measured amount of energy to the system and determining the heat loss. The experimental apparatus, the method used, and the results of these experiments are described.

l To determine the energy lost from the calorimeter, a known amount of electrical energy was converted to heat energy and used to heat up a known quantity of deionized (DI) water. The amount of energy absorbed by the water was calculated using its heat capacity and the temperature increase.

The amount of heat absorbed by the calorimeter was the difference between the heat input and that absorbed by the water. Af ter the temperature of the water was raised 10*C, corresponding to the rise seen in the cement solidification tests, power was shut off and the water temperature allowed to return to ambient.

This allowed calculation of the rate of heat loss. The equations used were:

1) AH

= I Rt input where I is the current in amperes, R is the resistance in ohms, and t is the time in seconds.

The units of this calculation are joules. The units may be converted to calories by dividing by 4.184.

2)

AHHO" p #*

2 Where C is the heat capacity of water (4.2 J/g/K), AT is p

the change in temperature, and m is the mass of the water, i

3) C

= (AH

~ ^N I I6 p

input H0 2

4)

Rate of Heat Loss = (-aHH O) t 2

E.3 i

g 4

_a Figure E-1 is an electrical schematic of the experimental system, and Figure E-2 is a schematic of the calorimetric cell.

The heater was made from nichrome wire and had a resistance (R) of 2.55 a with current flowing.

The

[

I voltage drop across the heater was measured using a digital multimeter j

every 120 sec and monitored by a small laboratory computer.

The temperature y

of the water and of room air was monitored using the lab computer.

The

==

r current used in the AH input calculation was calculated based on the measured voltage drop and electrical resistance, i.e. (I =

).

t h

voltmeter

]

U Amp

}

000101; 3

t b-5 e

L i

i J

E FIGURE E-1.

Electrical Schematic of Technique Used to l

Determine Heat Capacities of Calorimetric Cells K

J It

=

f To Electrical

=

f System

(( j ermocouple Lead f

Th

/

2 Layers of Fiberf ax l

T /

Thermocouple in Thermocouple Well Heater 4

[

i 250 mi Pyrex Beaker Containing 100.0 g Dionized Dewar y

p Water Top Covered with Al Foil and Beaker Wall

/

r Wrapped with 1 Layer Fiberfax c <3334

=

1 E

[

v4

-2 Pieces Fiberf ar

[

[

FIGURE E-2.

Schematic of Calorimetric Cell 5

E.4 E

=

5 e

m

The results of these experiments are presented in Table E-2.

In both cases, 40% of the input energy was lost to the calorimetric cell.

The heat loss and the heat loss rate were both greater for the large dewar, probably because of the increased mass of the system.

TABLE E-2.

Heat Capacities and Heat Loss Rate for Calgrimetric Cells Used in Resin Solidification TestsI Sy stem AHinputa d AHH 0, J aHloss, J C (cell), J/K Heat loss, J/sec g

p Small Dewar(b) 7660 4770 2880 253 0.17 Big Dewar(c) 8820 5310 3510 278 0.25 (a)

Results reported in joules; units may be converted to calories by dividing by 4.184.

(b)

Dewar used for solidification tests with cask resins.

(c) Dewar used for solidification tests with new resins.

Heats of Solidification The heats of solidification for the laboratory-scale resin solidification tests were determined as shown Pelow:

AH (solidification) = AH (system) + C aT p

where AH (system) = Cp (calorimeter cell) AT + AH (lost from system)

C AT = enthalpy change noted from the cement-solidified resin p

sample.

aT

= maximum temperature attained minus initial temperature.

Using Solidification Test #9 (Cask A, Core 1) as an example we have AT

= (24.0*C-21.8*C) = 2.2 deg.

E.5

Cp (calorimeter cell) = 253 J/K = 60.47 cal /K Cp (cement sample) range = 0.222 to 0.312 cal /g/deg Rate of Heat Loss from System = 0.17 J/sec = 146.27 cal /h Time to Reach Maximum Temperature = 30 h Mass of Cement / Resin Sample = 211.9 g This gives a heat of solidification of aH (solidification) = AH (system) + C aT p

=Cp (calorimeter) AT + AH (lost from system)

+Cp (cement) AT AH (solidification) = (60.47 cal /K)(2.2 K)

+ (146.27 cal /h) (30 h)

+ (0.222 cal /g/K) (2.2 K)(211.9 g)

= (133.03 + 4388.10 + 103.49) cal.

= 4624.62 cal, or AH (solidification)/g of cement / resin sample = 21.8 cal /g.

Using the higher heat capacity value of 0.312 cal /g/K for the cement-solidified resin results in a heat of solidification of 22.02 cal /g for Test

  1. 9, Similar values are obtained for the other resin solidification tests.

E.6

APPENDIX F SIMULATED DEWATERING TESTS CASK DEWATERING PARAMETERS AND STANDARDS Tne following information concerning actual resin cask dewatering parameters and standards was provided to Battelle-Northwest by Arkansas Power and Light Company and should be considered proprietary information until permission for further dissemination is given by AP&L. This information provided the basis of t5e simulated dewatering tests performed by Battelle-Northwest.

Cask Dimensions Cask A ~ 103 cubic feet liner External diameter = 60 in.

Height

= 72 in.

Inner diameter a 58 in.

Inner height 2 67 in.

Dewatering Cycle and Cask Disposal Criteria Dewatering Cycle: 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> pumping,16 hours1.851852e-4 days <br />0.00444 hours <br />2.645503e-5 weeks <br />6.088e-6 months <br /> of no pumping.

During dewatering, the pump rate is set when pumping water.

If the pump quits pumping water, it pumps air and the pump rate increases when pumping air.

Normally, the pump is readjusted when it is pumping air to the same pump rate used for pumping water.

However, if no one was present to readjust the pump rate, it could have pumped air at a greater rate than that used for wa ter.

Water Standard for Liner Burial: <2 L of free water at end of an 8-heur pump cycle.

F.1

Pump Parameters Pump Capacity 3 1.5 gallon of water per second.

Average Displacement per Stroke = 0.34 gal. (1.3 L)

Minimum Chem-Nuclear Specifications = Pump rate of 15-20 strokes per minute (minimum).

Pump Rate Set by APSL: 2 strokes per second when pumping water.

Possible pump rate is 3-5 strokes per second (information from Chem-Huclear representative at AN0).

CALCULATIONS / ASSUMPTIONS USED FOR LABORATORY-SCALE SIMULATED DEWATERING TESTS The following gives the complete calculations and assumptions used by Battelle-Northwest to conduct the laboratory-scale simulated dewatering tests.

Air Flow Through Cask Resin Bed Pump rate: Minimum = 2 strokes /sec.

Maximum = 5 strokes /sec.

Air Flow through Resin Bed:

Minimum = (2 strokes /sec)(1.3 L/ stroke) 2.6 L/sec.

=

Maximum = (5 strokes /sec) (1.3 L/ stroke) 6.5 L/sec.

=

Cask and Resin Bed Volume 2

Cask Volume: Volume = nr h

= (n)(29 in)2(67 in) 3

= 176,929 in 1 in3 = (2.54 cm)3 = 16.39 cm3 3

Volume = 2,899,875 cm

= 2,899 L F.2

3 Check: Stated volume a 103 f t 3

3 (103 ft )(12 in/ft)3

= 177,984 in 3

= 2,917,158 cm

= 2,917 L Check is close enough - use volume based on estimated inner dimensions

(~2900 L).

Cross-Sectional Area of Resin Bed:

2 Area = vr

= n(29 in)2 2

= 2,640 in 2

= 17,037 cm Resin Volume

= (Cross-Sectional Area)

(Resin bed depth) 2

= (2,640 in ) (42 in) 3

= 110880 in

= 1817 L Exit Velocity Exit Velocity

= Flow rate / cross-sectional area.

3 2

Minimum = (2,600 cm /sec)/(17,037 cm )

= 0.15 cm/sec.

3 2

Maximum = (6,500 cm /sec)/(17,037 cm )

= 0.38 cm/sec.

A 300 mL volume of resin bed was used in the experimental dewatering tests; the air flow rates needed to duplicate the AP&L dewatering conditions are:

F.3

Minimum Air Flow:

300 mL x

6 3

1.8x10 mL 2.6x10 mL/sec.

2 3

x,(3 x 10 mL)(2.6x10 mL/sec.)

6 1.8x10 mL x = 0.433 mL/sec.

x 26.0 mL/ min.

Maximum Air Flow:

300 mL x

6 3

1.8x10 mL 6.5x10 mL/sec.

2 x,(3 x 10 mL) (6.5 x 10 mL/sec) 6 1.8 x 10 mL x = 1.083 mL/sec.

x = 65.0 mL/ min.

Dewatering Test Air Flow Rates:

For 300 mL resin: Minimum a 26 mL/ min.

Maximum s 65 mL/ min.

Predicted Maximum Temperature Increase for Dewatering Tests The thermodynamic calculations discussed under Phase III used an estimated resin composition in Cask A of ARA-9371, ARC-9358, IRA-200C and IRA-900C, present in equal volumes. The same assumed composition is used in the following calculations.

F.4

Assume 300 mL of resin:

Composition = 38.8 g H 0/100 mL

= 116.4 g H 0/300 mL 2

2 36.6 g Exchanger /100 mL

= 109.8 g Exchanger /300 mL (24.6% void space).

0.3 cal /g/deg.

Assume the heat capacity of the exchanger

=

Airflow through resin bed:

Minimum =

1,560 mL/h.

Maximum =

3,900 mL/h.

20.95% 0 )

Oxygen flow through resin bed (air

=

2 Minimum = 326.8 mL/h.

1.5x10-2 mole 0 /h.

s 2

Maximum = 817.0 mL/h.

-2 3.6x10 mole 0 /h.

=

2 aH for resin (using ethyl benzene as a representative " stand-combustion in") from thermodynamic calculations is:

aH

= -11 M kca Umole 0 to form carbon and water (liq. ).

comb 2

Assuming 100% utilization (reaction) of the oxygen passing through the resin gives heat of combustion rates.

AHcomb (minimum 02flow) = -1.72 kcal/hr.

aHcomb (maximu 0 flow) = -4.12 kcal/hr.

2 Heat Available to Raise Temperature of Resin Bed:

AH

- Heat Loss to Dewar - Heat loss to air being passed through bed.

comb The heat loss to the air being passed through the bed is estimated as follows:

Heat capacity of 02 = 7.017 cal /deg/ mole Heat capacity of N2 = 6.960 cal /deg/ mole.

F.5

If it is assumed all the 02 reacted, only the heat capacity of N2 should be considered (the difference in the heat capacity of 02 and N2 is insignificant for the present purpose even if the assumption is not correct).

Minimum N flow through 300 mL experimental resin bed = 1233 mL/h 2

= 5.5x10-2 mole N /h 2

Maximum N flow through 300 mL experimental resin bed = 3083 mL/h 2

= 1.4x10-1 mole N /h 2

The maximum heat absorbed by the N2 in 300 mL experimental resin bed is:

-3

-2 (6.960x10 kcal/deg/ mole)(5.5x10 mole /h)

Minimum flow

=

-4 3.8x10 kcal/deg/h

=

(6.960x10-3 kcal/deg/ mole)(1.4x10-1 mole /h)

Maximum flow

=

-4 9.7x10 kcal/deg/h

=

exiting the system was Thus, we concluded that the heat loss to the N2 negligible in comparison to the heat of combustion and to the other heat sinks in the system (dewar plus (resin + water)) and could be neglected.

The heat rate loss from the dewars used in the experimental dewatering tests was estimated from the data obtained in Test 4 (see Table 6) in which heated resin was used; the 6 hour6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> time period was used for these calculations.

300 mL resin bed a 226.2 g Initial Temperature = 54' C Final Temperature

= 28'C Heat Loss Rate

= AH/at = Cp AT/at

= (1.5x10-1 kcal/deg)(26 deg)/6 h

-1

= 6.5x10 kcal/h The heat absorbed by the water and exchanger material present in the experimental system (300 mL resin bed) was calculated as shown below:

Heat Absorbed by Water Present in the Resin:

= (116.4 g H 0)(1x10-3 kcal/deg/g H 0) 2 2

1.2x10-1 kcal/deg 3

F.6

Heat Absorbed by Exchanger:

= (109.8 g exchanger)(3x10-4 kcal/deg/g exchanger)

-2 s 3.3x10 kcal/deg Heat Absorbed by 300 mL Resin Bed a 1.5x10~I kcal/deg Therefore, the heat available to raise the temperature of the resin bed is:

aHcomb - Heat Loss Rate of Dewar At the minimum flow rate:

Heat available = -1.72 kcal/h + 0.65 kcal/h

= -1.07 kcal/h At the maximum flow rate:

Heat available = -4.12 kcal/h + 0.65 kcal/h

= -3.47 kcal/h The expected temperature increase in the experimental system (300 mL resin bed), assuming 100% utilization of the oxygen in the air passing through the bed would be:

AT(increase) = (Heat Available)/(Heat Absorbed by Resin Bed)

At the minimum flow rate, AT = (1.07 kcal/h)/(0.15 kcal/deg) a 7 deg/h At the maximum flow rate AT = (3.47 kcal/h)/(0.15 kcal/deg) s 23 deg/h During the early stages of the dewatering process, one would not expect 100% oxygen utilization for oxidation.

In reality, to approach 100% oxygen utilization, the heat loss rate through the system and to the air flowing through the system must be slower than the rate of heat increase caused by the oxidation process.

The experimental dewatering tests and the simulated dewatering test calculations do reemphasize, however, that even if all available oxygen were used, the temperature increase would be relatively slow in a bed of resin undergoing air oxidation at the air flow rates used in cask dewatering.

F.7

.