pp atop 3 3N o

UNITED STATES 3

.i NUCLEAR REGULATORY COMMISSION i

WAsHINoTON. D.C 20t46

%...../

I BALTIMORE GAS AND ELECTRIC COMPANY DDf1ET NO. 50-317 CALVERT CLIFFS NUCLEAR POWER PLANT UNIT NO. 1 AMENDMENT'TO FACILITY OPERATING LICENSE Amendment No. -176 License No. DPR-53 1.

The Nuclear Regulatory Commission (the Commission) has found that:

A.

The application for amendment by Baltimore Gas and Electric Company (the licensee) dated September 1, 1992, as supplemented on November 11, 1992, complies with the standards and requirements-of the Atomic Energy Act of 1954, as amended (the Act) and the-Commission's-rules and regulations set forth in 10 CFR Chapter I; B.

The facility will o)erate in conformity with the application, the provisions of tie Act, and the rules and regulations of the Commission; C.

There is reasonable assurance (1) that the activities authorized by this amendment can be-conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Commission's regulations; D.

The-issuance of this amendment will not be inimical to the; common defense and security or to-the health.and safety of the public;J and E.

The issuance of this amendment is in accordance with~10 CFR'Part-51 of the Commission's regulations and all applicable requirements have been satisfied.

i 2.

Accordingly, the license is amended by. changes to the Technical.

Specifications as indicated in the attache:/,t~to this license amendment,.

and paragraph 2.C.(2) of Facility Operating License No. DPR-53_is hereby amended to read as follows:-

9301050343 921211 U

.PDR ADOCK 05000317

~

m, P-PDR~'

m, w

..- m.

. w.~...

. (2) Technical Specifications The Technical Specifications contained in Aapendices A and B, as revised through Amendment No.176, are heresy incorporated in the license.

The licensee shall operate the facility in accordance with the Technical Specifications.

3.

This license amendment is effective as of the date of its issuance and shall be implemented within 30 days.

FOR TllE NUCLEAR REGULATORY COMMISSION f,

y"Y Robert A. Capra. Director Project Directorate 1-1 Division of Resctor Projects - 1/11 Office of Nuclear Reactor Regulation

Attachment:

Changes to the Technical Fbecifications Otto of Issuance: December 22, 1992 4

[pm uo,$*

v

.'*s UNITED STATES n

i NUCLEAR REGULATORY COMMISSION

  • [

f WASWNoToN. O c Ws6 BALTIMORE GAS AND_ELECTRLC COMPANY DOCKET NO. 50-310 CALVERT CLIFFS NUCLEAR POWER PLANT. UNIT _N(L_2 AMENDMENT TO FACILITY OPERATING LICENSE Amendment No. 153 License No. DPR-69 1.

The Nuclear Regulatory Commission (the Commission) has found that:

A.

The application for amendment by Baltimore Gas and Electric Company (the licensee) dated September 1, 1992, as supplemented on November 11, 1992, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act) and the Commission's rules and regulations set forth in 10 CFR Chapter I; B.

The facility will o)erate in conformity with the application, the provisions of tie Act, and the rules and regulations of the Commission; C.

There is reasonable assurance (i) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Commission's regulations; D.

The issuance of this amendment will not be inimical to the common defense and security or to the health and safety of the public; and E.

The issuance of this amendment is in accordance with 10 CFR Part 51 of the Commission's regulations and all applicable requirements have been satisfied.

2.

Accordingly, the license is amended by changes to the Technical Specifications as indicated in the attachment to this license amendment, and paragraph 2.C.2 of facility Operating License No. DPR-69 is hereby amended to read as follows:

l.

. (2) Igchnical Specifications The Technical Specifications contained in Appendices A and B, as revised through Amendment No.153 hereby incorporated in the license.

The licensee shall operate ti..

.llity in accordance with the lechnical Specifications.

3.

This license amendment is effective as of the date of its issuance and shall be implemented within 30 days.

FOR Tile NUCl. EAR REGULATORY COMMISSION N

d' Robert A. Capra, Director Project Directorate 1-1 Division of Reactor Projects - 1/11 Office of Nucicar Reactor Regulation

Attachment:

Changes to the Technical Specifications Date of issuance: December 22, 1992

h ATTACHMENT TO LICENSE AMENDMENTS AMENDMENT NO. 176 FAClllTY OPERATING LICENSE NO. DPR-53 AMENDMENT NO. 153 FACILITY OPERATING LICENSE NO. 0PR-62 DOCKET NOS. 50-317 AND 50-318 l

Revise Appendix A as follows:

i Remove Paaes Insert Paaga 5-5 5-5 f

_. _ _ _ _ _. _ _ _ _. _ _ _ _.m.

5.0 DE51GN FEATURES VOLUME 5.4.2 The total water and steam volume of the Reactor Coolant System is 10,614 1 460 cubic feet at a nominal T.,, of 532'F.

5.5 HETEOR0 LOGICAL TOWER LOCATION 5.5.1 The meteorological tower shall be located as shown on Figure 5.1-1.

-1 5.6 FUEL STORAGE 4

CRITICAllTY - SPENT FUEL 5.6.1 The spent fuel storage racks are designed and shall be maintained with a minimum 10 3/32" x 10 3/32" center-to-center distance between fuel assemblies placed in the storage racks to ensure a k,, of < 0.95 with the.

t storage pool filled with unborated water. The k of < 035 includes the conservative allowances for uncertainties descrili,e,d in~Section 9.7.2-of the FSAR. The maximum fuel enrichment to be stored in the fuel pool will be 4.52 weight percent.

l CRITICALITY - NEW FUEL 5.6.2 The new fuel storage racks are designed and shall-be maintained with a nominal 18 inch center-to-center distance between new-fuel assemblies such that k,, will not exceed 0.95 when fuel having a maximum enrichment of 5.0 weight, percent-U-235 is in place and various densities of unborated-

- water are assumed including aqueous: foam moderation and full flood--

conditions. The k, of < 0.95 includes the conservative allowance for uncertainties desc,r,ibed Tn Section 9.7.2 of the FSAR.

DRAINAGE 5.6.3 The spent fuel storage pool is designed and shall be maintained to prevent inadvertent draining of the pool below elevation 63 feet.

CALVERT CLIFFS - UNIT 1 -

5-5 Amendment No. 176.

c

-,u----.a-,.a._-_,.--,...._-....

,m.__

5.0 DE5!GN FEATURES 5.5 tgTEOR0LOGICALTOWERLOC..10N i

5.5.1 The meteorological tower shall be located as shown on Figure 5.1-1.

l 5.6 FUEL STORAGE CRITICALITY - SPENT FUEL 5.6.1 The spent fuel storage racks are designed and shall be maintained with a minimum 10 3/32' x 10 3/32' center-to center distance between fuel assemblies placed in the storage racks to ensure a k,, of < 0.95 with the storage pool filled with unborated water. The k of<0.95includesthe conservative allowances for uncertainties describ,e,d in Section 9.7.2 of the FSAR. The maximum fuel enrichment to be stored in the fuel pool will be l

4.52 weight percent.

l CRITICALITY - NEW FVEL 5.6.2 The new fuel storage racks are designed and shall be maintained with a nominal 18 inch center-to-center distance between new fuel assemblies such that k,,, will not exceed 0.95 when fuel having a maximum enrichment of 5.0 weight percent U-235 is in place and various densities of unborated water are assumed including aqueous foam moderation and full flood conditions. The k,, of < 0 l

1 uncertainties desc,ribed in.95 includes the conservative allowance for Section 9.7.2 of the FSAR.

DRAINAGE 5.6.3 The spent fuel storage pool is designed and shall be maintained to prevent inadvertent draining of the pool below elevation 63 feet.

CAPACITY 5.6.4 The fuel storage pool is designed and shall'be maintained with a combined storage capacity, for both Units 1 and 2, limited to no more than 1830 fuel assemblies.

5.7 COMPONENT CYCLIC OR TRANSIENT LIMITS 5.7.1 The com)onents identified in Table 5.7-1 are designed and shall be maintained witiin the. cyclic or transient limits of Table 5.7 4 4

4 e

f CALVERT CLIFFS - UNIT 2 5-5 Amendment No. 153

.