ML20126F586
| ML20126F586 | |
| Person / Time | |
|---|---|
| Site: | FitzPatrick |
| Issue date: | 05/29/1985 |
| From: | Vassallo D Office of Nuclear Reactor Regulation |
| To: | Power Authority of the State of New York |
| Shared Package | |
| ML20126F588 | List: |
| References | |
| DPR-59-A-091 NUDOCS 8506170549 | |
| Download: ML20126F586 (4) | |
Text
'd#
%o j
UNITED STATES y
- "h NUCLEAR REGULATORY COMMISSION j
g WASHINGTON, D. C. 20555
, e
+
POWER AUTHORITY OF THE STATE OF NEW YORK DOCKET N0. 50-333 JAMES A. FITZPATRICK NUCLEAR POWER PLANT AMENDMENT TO FACILITY OPERATING LICENSE Amendment No. 91 License No. DPR-59
~1.
The Nuclear Regulatory Comission (the Commission) has found that:
A.
The application for amendment by the Power Authority of the State of New York (the licensee) dated January 30, 1985, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act), and the Commission's rules and regulations set forth in 10 CFR Chapter I; 8.
The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of
~
the Commission; C.
There is reasonable assurance (i) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be
~conducted in compliance with the Comission's regulations; D.
The issuance of this amendment will not be inimical to the common defense and security or to the health and safety of the public; and E.
The issuance of this amendment is in accordance with 10 CFR Part 51 of the Commission's regulations and all applicable requirements have been satisfied.
2.
Accordingly, the license is amended by changes to the Technical Specifications as indicated in the attachment to this license amendment and paragraph 2.C(2) of Facility Operating License N'o.
DPR-59 is hereby amended to read as follows.
I t
8506170549 850529 PDR ADOCK 05000333 P
PDR i
.?.
(2) Technical Specifications The Technical Specifications contained in Appendices A and B, as revised through Amendment No. 91, are hereby incorporated in the license. The licensee shall operate the facility in accordance with the Technical Specifications.
3.
This license amendment is effective as of the date of its issuance.
FOR THE NUCLEAR REGULATORY COMMISSION e
Domenic B. Vassallo, Chief Operatino Reactors Branch #2 Division of Licensing
Attachment:
Changes to the Technical Specifications Date of Issuance: fiay 29,1985 1
8
1 ATTACHMENT TO LICENSE AMENDMENT NO. 91 FACILITY OPERATING LICENSE NO. DPR-59 DOCKET NO. 50-333 Revise the Technical Specifications by removing page 198 and inserting the revised page 198.
w T
e O
l e
l 3
e i
i i
e
,a
,,,.-,-n.-
JAFNPP FAsLE 3.7-1 PROCESS PIPELINE PENErRATING PRIMARf CONTAINMENT (Numbers in parentheses are keyed to numbers on following pages equal codes are listed codes are listed on following pages)
Power Locatton Power Drywell Valve type to Open Ref. to to Close Isolation Closing Normal Remarks and Line teolated Penetration (6)
(5) (6) Group Drywell (5 ) (b) signal Time (7) Status Exceptions Main Steam Line E-74,8,C D AO Globe Air and A
Inside Air and 8,C.D,P,5 Note (1) Open AC, DC spring Main Steam Line 1-74,8,C,0 AO Globe Air and A
Outside Air and 8,C D,P,5 Note (1) Open AC, DC spring Main Steam Line E-S MO Gate AC 4
Inside AC 8,C,D,P,5 15 sec closed Drain Main Steam Line X-S MO Gate DC A
Outside DC S.C D.P,8 15 sea closed Drain From Reactor X-94, S Check A
Outside Process Sev. flow MA Open Feedwater From Reactor X-94, S Check A
Inside Process Rev. flow HA Open reedwater Reactor Water X-41 AO Globe Air and 4
Inside Spring 8,C NA Open Sample AC Reactor Nater K-41 40 Globe Air and A
Outside Spring 8,C NA Open Sample AC Control Rod Hy-1-36 Check A
Inside Process Rev. f low NA) draulic Return I
Control Rod Hy-X-36 Check A
Outside Process Rev. flow NA) Opens on Rod drau11c Return I movement and I closed at all I other times, Note (4)
)
Control Rod X-38
$0 Valves Air and A
Outside Spring Note (4)
NA)
Drive Exhaust AC I
I I
)
Control Rod 1-38 30 valves Atr tnd A
Outside Spring Note (4)
NA)
Drive EEh4Gst AC I
Control Rod X-37 30 Valveq Air and A
cutsido Jering Note ( 4)
NA)
Drive Inlet AC I
l I
Cantrol RoJ E-37 30 Valves Air and A
Guts 1Je Spring Note (4)
NA)
Drtve Inlet AC Amerdnent !b. J8', 91
.l j
198
.