ML20126C822

From kanterella
Jump to navigation Jump to search
Forwards Reactor Containment Building Integrated Leakage Rate Test for Comanche Peak Steam Electric Station Unit 2 Final Rept, Reflecting Summary of Unit 2 Prestart Test Program ILRT Conducted During Period 920910-15
ML20126C822
Person / Time
Site: Comanche Peak 
Issue date: 12/18/1992
From: William Cahill, John Marshall
TEXAS UTILITIES ELECTRIC CO. (TU ELECTRIC)
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML20126C825 List:
References
TXX-92610, NUDOCS 9212230232
Download: ML20126C822 (1)


Text

_ - _ _ _ _ _ _ _

m Log # TXX-92610 CC File # 10110 L

j 906.2 C

C TUELECTRIC December 18, 1992 William J. CahlH, Jr.

Gran p Vier l'unilent U. S. Nuclear Regulatory Commission Attention:

Document Control Desk Washington, DC 20555

SUBJECT:

COMANCHE PEAK STEAM ELECTRIC STATION (CPSES) - UNIT 2 DOCKET NO. 50-446 TRANSMITTAL OF THE REACTOR CONTAINMENT BUILDING INTEGRATED LEAKAGE RATE TEST REFORT Gentlemen:

The CPSES Unit 2 Prestart Test Program Integrated Leakage Rate Test (ILRT) was conducted during the period September 10-15. 1992.

In accordance with 100FR50, Appendix J, paragraph V.B. enclosed is a summary technical report entitled " Reactor Containment Building Integrated leakage Rate Test" which provides the required information.

Siacerely, William J. Cahill, Jr.

By:

J. S. Marshall Generic Licensing Manager RC/grp Enclosure c-Mr. J L.

.thoan, Region IV Resident inspectors, CPSES (2)

Mr. B. E. Helian, NRR 2300G ppi 'p

2 a2288g gggg d

. oo,, s.,m, umi ma... m.. m>i 5

PDR

__ _