. _..

6

+

0 B&W Nuclear Environmental

/-

a McDermott company P.O. Bon 11165 Lynchburg. YA 245061165 l

(804) 522 5414 November 5,1992 M-W

.\\

y;;, no, Copies Tet M e % IIO U.S. Nuclear Regulatory Commi3sion c y(. g m

Region 11 dg yug Attn: J. P. Stohr, Director Division of Radiation Safety and Safeguards 101 Marietta St N.W.

Atlanta, GA 30323 i.

d

Subject:

Reply to a Notice of Violation Gentlemen:

In accordance with 10 CFR 2.201, the Babcock & Wilcox Company, Nuclear Environmental Seivices Lynchburg Technology Center (LTC), is providing the attached reply to the referenced Notice of Violation contained in NRC Inspection Report No. 70-824/92-02, dated May 29,1992 and your follow-up letter of October 22,1992.

{

if you should have any further questions, please feel free to contact me.

Sincerely,

-d i

he C. Boyd, Jr.

Licensing & Compliance Officer i

Attachment l